Honeywell TB7600 Series Specifications

63-2706-04
TB7600 Series Communicating
TB7600 Series
Thermostat
TB7600 Series
Thermostat with
Occupancy Sensor
RTU/Heat Pump Thermostats
FOR COMMERCIAL HVAC APPLICATIONS
SPECIFICATION DATA
advantageous energy savings during occupied hours without sacrificing occupant comfort. All thermostats are PIR ready and can be ordered with or without Honeywell occupancy sensor. The occupancy sensor cover is available to order separately if a PIR is needed at a later time.

FEATURES

• Available in BACnet MS/TP and ZigBee wireless protocols
• Backlit LCD display with dedicated function menu keys for simple operation
• Built in default profile set-up for easier start up and commissioning
• Fully integrated advanced occupancy functionality with a PIR accessory cover on some models
• Non-volatile EEPROM memory prevents loss of parameters during power outage

APPLICATION

The TB7600 Series PI thermostat family is specifically designed for single stage and multi-stage control of heating/ cooling equipment such as rooftop and self-contained units. The TB7600 Series are communicating thermostats with models available in BACnet® MS/TP and ZigBee® wireless mesh protocols and can be easily integrated into a WEBs-AX building automation system based on the NiagaraAX® platform. The product features an intuitive, menu-driven, back­lit LCD display, which walks users through the programming steps, making the process extremely simple. Accurate temperature control is achieved due to the product’s PI time proportional control algorithm, which virtually eliminates temperature offset associated with traditional, differential­based thermostats.
Depending on the model, up to three remote sensor inputs are available. All models contain a SPST auxiliary switch, which can be used to control lighting or disable the economizer function and a discharge air sensor input. For more advanced applications, economizer control logic has been integrated into the thermostat for use with proportional damper economizer actuators.
Thermostats equipped with an occupancy sensor cover provide advanced active occupancy logic, which will automatically switch occupancy levels from Occupied to Unoccupied as required by local activity being present or not. This advanced occupancy functionality provides
• Programmable smart fan operation can provide energy savings during night mode
• Password protection to minimize parameter tampering
• Three levels of keypad lockout to limit access to change user parameters such as setpoints, system mode, etc.
• Gas/oil or electric system compatibility for all type of applications
• SPST auxiliary output can be used for lighting and/or economizer override
• 0 to 10 Vdc economizer output for more retrofit opportunities
— Built in dry bulb economizer logic using outdoor tem-
perature sensor
— Input for supply/mixed air temperature sensor
• Support single and two stages heat pump with one auxiliary heat stage
• Remote indoor averaging sensing with 2, 3, 4, 9 or 16 sensors
• Remote discharge air sensor input
• Automatic frost protection to prevents costly freeze damage
• Anti short cycle and minimum on/off run time protection to reduce wear and maximizes life span of mechanical equipment
TB7600 SERIES COMMUNICATING RTU/HEAT PUMP THERMOSTATS
• Two programmable digital inputs for added flexibility can be use to monitor filter status, activate a remote temporary occupancy switch, and/or used as a general purpose service indicator
• 7 day programmable models, 2 or 4 events for use in non-networked applications*
• Six hour reserve prevents the need to reprogram day/ time on programmable models after a power outage on programmable models
Heat Pump Model Specific Features
• Selectable single or dual stage compressor stages
• High balance point locks out auxiliary heating when outside air temperature is above set value, low balance point locks out heat pump compressor operation when outside air temperature is below the set value
• Comfort/economy mode maximizes heat pump use before turning on auxiliary heating
• Compressor/auxiliary interlock adds flexibility by locking out heat pump operation during auxiliary heating to prevent high pressure trip when the coil is downstream of the auxiliary heat source
* Use programmable models only when installing as stand-
alone thermostats that may eventually be added to a WEBs-AX network. When a programmable thermostat is added to a network, schedules should be applied through the WEBStation-AX.
More Information
To learn about additional products in this family visit http://customer.honeywell.com.
• TB7300 Series Communicating Fan Coil Unit Thermostats Specification Data (Form No. 63-2709).
• TB7200 Communicating Zoning Thermostats Specification Data (Form No. 63-2708).
• Sensors Product Overview Brochure (Form No. 63-9285) for a complete listing of compatible sensors.

TB7600 Series Model Selection

Product Number Description Outputs Scheduling
BACnet Models
TB7600A5014B Single Stage RTU 1H/1C No
TB7600A5514B Single Stage RTU 1H/1C No X
TB7600B5014B Multi-stage RTU 2H/2C No
TB7600B5514B Multi-stage RTU 2H/2C No X
TB7600H5014B Heat Pump 3H/2C No
TB7600H5514B Heat Pump 3H/2C No X
TB7605B5014B Economizer RTU 2H/2C No
TB7605B5514B Economizer RTU 2H/2C No X
TB7652A5014B Single Stage RTU 1H/1C Yes
TB7652A5514B Single Stage RTU 1H/1C Yes X
TB7652B5014B Multi-stage RTU 2H/2C Yes
TB7652B5514B Multi-stage RTU 2H/2C Yes X
TB7652H5014B Heat Pump 3H/2C Yes
TB7652H5514B Heat Pump 3H/2C Yes X
TB7656B5014B Economizer RTU 2H/2C Yes
TB7656B5514B Economizer RTU 2H/2C Yes X
Wireless Models
TB7600A5014W Single Stage RTU 1H/1C No
TB7600A5514W Single Stage RTU 1H/1C No X
TB7600B5014W Multi-stage RTU 2H/2C No
TB7600B5514W Multi-stage RTU 2H/2C No X
TB7600H5014W Heat Pump 3H/2C No
TB7600H5514W Heat Pump 3H/2C No X
TB7605B5014W Economizer RTU 2H/2C No
TB7605B5514W Economizer RTU 2H/2C No X
TB7652A5014W Single Stage RTU 1H/1C Yes
TB7652A5514W Single Stage RTU 1H/1C Yes X
TB7652B5014W Multi-stage RTU 2H/2C Yes
1
Occupancy
Sensor
2
63-2706—04 2
Loading...
+ 2 hidden pages