Honeywell T8131A, T8132C, T8131C, T8131B, T8132B, T8132A User Manual
T8131A,B,C; T8132A,B,C
Programmable Thermostats
The T8131 and T8132 Thermostats provide
energy savings for single-stage heating and cooling applications while providing reliable, precise
temperature control.
T8131C
T8132C
T8131/T8132 Models
■ HEAT-OFF-COOL system switch.
■ AUTO-ON fan switch.
■ Separate programs for weekdays and weekends
5 day/2 day.
■ Digital LCD display.
■ Easy to program and install.
■ Precise temperature control.
■ Four daily energy saving programs.
■ Available in taupe and Premier White
■ Compatible with most 24 Vac standing pilot, gas
electronic ignition, oil or central electric systems.
™
.
T8131 Models Only
■ Powered directly from 24 Vac system transformer.
■ Green light emitting diode (LED) lights when prop-
T8131A,B,C; T8132A,B,C
SPECIFICATIONS • ORDERING INFORMATION
Specifications
IMPORTANT: The specifications given in this publica-
tion do not include normal manufacturing tolerances; therefore, an individual unit may not exactly
match the listed specifications. Also, this product is
tested and calibrated under closely controlled conditions, and some minor differences in performance
can be expected if those conditions are changed.
MODELS:
T8131A/T8132A Programmable Thermostats: Provide
eight program keys; with keyboard door.
Fig. 1—Dimensions in in. [mm] of T8131 and T8132 models.
7
6 [175]
8
T8131B/T8132B Programmable Thermostats: Provide
eight program keys; without keyboard door.
T8131C/T8132C Programmable Thermostats: Deluxe
models, provide twelve program keys including usage key; with keyboard door.
ELECTRICAL RATING: T8131: 24 Vac.
T8132: Battery operated (2 AA alkaline batteries).
SYSTEM AND FAN RATINGS:
1.2A run; 7.5A inrush.
Total cooling and fan load not to exceed 1.2A.
DIMENSIONS: See Fig. 1.
3
[19]
4
1
1
4
[32]
4
[102]
1 [25]
M9349
MOUNTING MEANS: Position mounting plate directly
on wall using two mounting screws and wall anchors
provided (See Fig. 2).
LIGHT EMITTING DIODE (LED): One LED on T8131
models only; lights to indicate proper operation when
both sides of the 24 Vac system transformer are prop-
erly connected. See Fig. 2 for position of LED.
OPERATING AMBIENT TEMPERATURE RANGE:
40° F to 110° F [4° C to 43° C].
SHIPPING TEMPERATURE RANGE: -20° F to 120° F
[-29° C to -49° C].
OPERATING RELATIVE HUMIDITY: 5 percent RH to
90 percent RH; noncondensing.
TIME INDICATION: 12 hour with AM, PM indication.
SET POINT RANGE: 45° F to 88° F [7° C to 31° C].
Ordering Information
When purchasing replacement and modernization products form your TRADELINE® wholesaler or your distributor, refer to the
TRADELINE Catalog or price sheets for complete ordering information, or specify—
1. Order Number.
2. Accessories, if desired.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of phone directory).
2. Home and Building Control Customer Satisfaction
Honeywell Inc., 1985 Douglas Drive North
Minneapolis, Minnesota 554212-4386 (612) 951-1000.
In Canada—Honeywell Controls Limited/Honeywell Limitée, 740 Ellesmere Road, Scarborough, Ontario M1P 2V9 . International
Sales and Service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan,
Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0148—12
CYCLES PER HOUR ADJUSTMENT:
Heating: Field adjustable to 3, 6, or 9 cph ±10 percent.
Cooling: Factory-set at 3 cph ±10 percent (not field
adjustable).
CALIBRATION: Thermostat and thermometer self-cali-
brating to ±1.25° F.
FINISH: All models available in taupe and Premier White™.
ACCESSORIES:
205013 Isolation Relay kit.
205014 Transformer Plug-in Kit.
205015 International Organization for Standardization
Relay and Transformer.
WHEN INSTALLING THIS PRODUCT…
1. Read these instructions carefully. Failure to follow
instructions can damage product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on the
product and the compatibility chart below to make sure the
product is suitable for your application.
3. Make sure installer is a trained, experienced service
technician.
4. After completing installation, use these instructions
to check out product operation.
COMPATIBILITY
Check Table 1 to make sure the thermostat is compatible
Oil-Fired FurnaceYes
Electric FurnaceYes
Electric Air ConditioningYes
Baseboard Electric
No
(120/240 Line Volt)
Heat pumps/Multistage EquipmentNo
T8131A,B,C; T8132A,B,C
SPECIFICATIONS • INSTALLATION
Fig. 2—T8131 LED.
LED LIGHTS WHEN
PROPERLY CONNECTED
POWER
M9365
Installation
WARNING
ELECTROCUTION HAZARD CAN
CAUSE PROPERTY DAMAGE, SEVERE
INJURY, OR DEATH.
Disconnect power supply before wiring to prevent electrical shock or equipment damage.
LOCATION
Locate the thermostat about 5 ft [1.5m] above the floor
in an area with good air circulation at average temperature.
Do not mount the thermostat where it may be affected by:
—drafts or dead spots behind doors and in corners.
—hot or cold air ducts.
—concealed pipes and chimneys.
— unheated (uncooled) areas such as an outside wall
behind the thermostat.
MOUNT THERMOSTAT MOUNTING PLATE
(FIG. 2)
Position mounting plate on wall. Use spirit level to make
sure mounting plate is level. Use a pencil to mark the two
mounting holes.
Level for appearance only; thermostat will function
properly even when not level. Tighten mounting screws.
Remove mounting plate from wall, and drill 3/16 inch
holes in wall (if drywall) as marked. For firmer material
such as plaster or wood, drill 7/32 inch holes. Gently tap
anchors (provided) into drilled holes until flush with the
wall.
Reposition mounting plate over holes, pulling wires
through wiring opening. Loosely insert two mounting
screws into holes.
Not compatible with any 120/240 volt circuit.
Not designed for steam or gravity systems.
a
Compatible with 2-wire Honeywell zone valves. Isolating
relay required for 3-wire thermostats for zone valves. Not
compatible with 2-wire White Rodgers no. 1361 Valves.
368-0148—1
T8131A,B,C; T8132A,B,C
INSTALLATION
Fig. 3—Mounting thermostat mounting plate.
WALL
ANCHORS (2)
WIRES THROUGH
WALL OPENING
WALL
MOUNTING
PLATE
MOUNTING
SCREWS (2)
M1718
WIRING
All wiring must comply with all applicable electrical
codes, ordinances, and regulations. Follow instructions
provided with the controlled equipment.
Loosen the terminal screws and slip each wire beneath
its matching terminal. See Fig. 4 for wiring insertion techniques. Tighten terminals securely.
Plug the hole in the wall with insulation to help prevent
drafts from adversely affecting thermostat operation.
T8131 Models
Run the required number of wires to the thermostat
location (check the appropriate wiring diagram). Refer to
Figs. 5 through 7 for typical wiring diagrams.
T8132 Models
Run the required number of wires to the thermostat
location (check the appropriate wiring diagram). Refer to
Figs. 8 through 11 for typical wiring diagrams.
In 5-wire installations only, be sure to remove the factory-installed jumper connecting terminals R and Rc.
Fig. 4—Proper wiring technique.
PROPER WIRING TECHNIQUE
INSERT
5/16 in.
[8 mm]
STRIP
STRAIGHT
UNDER
SCREW HEAD
Fig. 5—3-wire heat-only application.
3-WIRE HEAT-ONLY
A
B
W Y G
C
HEATING
RELAY OR
VALVE COIL
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
Fig. 6—4-wire cool-only application.
4-WIRE COOL-ONLY
A
B
W Y G
C
COOLING
CONTACTOR
COIL
FAN
RELAY
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
R
Fig. 7—5-wire heat/cool application.
5-WIRE HEAT/COOL
A
B
W Y G
C
R
1
L1
(HOT)
L2
M9213
1
L1
(HOT)
L2
M9212
R
END OF WIRE
VISIBLE HERE
M3825
68-0148—14
HEATING
RELAY OR
VALVE COIL
COOLING
CONTACTOR
COIL
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
FAN
RELAY
1
L1
(HOT)
L2
M9214
Loading...
+ 8 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.