The RF6GB is a wireless glassbreak detector intended for use with Honeywell controls that support SiX™
To remove the mounting bracket:
Series devices.
The RF6GB can be mounted
on the wall or on the ceiling.
• within 7.6 m (25 feet) of the
protected glass;
• within clear view of the
protected glass;
• at least 2 m (6.5 feet) from the
floor;
• at least 1 m (3.3 feet) from
forced air ducts;
• at least 1 m (3.3 feet) from
sirens or bells greater than 5
cm (2 inches) in diameter.
• between the protected glass
and any heavy window
coverings.
• when heavy window coverings
are present, the detector can
be mounted on the window
frame.
• Avoid mounting the detector
on the same wall as the
protected glass, on freestanding posts or pillars, or in
rooms with noisy equipment
(air compressors, bells, power
tools, etc.), if this equipment is
operated when the detector is
armed.
• UL requirements: TBD
Turn the top of the detector 15 degrees
counter-clockwise and separate the
mounting bracket.
: Before mounting the RF6GB
permanently, conduct Go/No Go tests (see
control’s instructions) to verify adequate
signal strength and adjust the device location
and orientation as necessary.
• The RF6GB can be mounted on the wall
or on the ceiling.
• The rear tamper plate MUST be mounted
to a stud, solid wood, or with a robust
wall anchor.

Enroll
This device can be enrolled and
programmed either before or after
installation.
1. Set the Lyric Smart Controller in
Programming Mode.
2. Remove the battery tab to activate the
device and begin the enrollment
process.
3. The RF6GB Green LED flashes during
enrollment (about 8 seconds*)
: Depending on the signal strength
between the device and the control, the
enrollment period may take longer than 8
seconds.
• The device sends its unique MAC ID
address (Serial Number) and Services
information to the control.
• The control registers the device and
displays the transmitter data on
screen.
4. Enrollment is confirmed When the
RF6GB Green LED is ON for 3 seconds
[and the control beeps TBD].
5. If the sensor is not successfully enrolled
during the enrollment period, the LED
turns off and the device powers down.
Activate the tamper, power down and
up again, or use the FG701 Glassbreak
Simulator to restart the enrollment
process.
: Once enrolled in a system, the detector cannot be used with
another control panel until it is removed from the current control
panel. See the Control’s instructions for details on removing
devices.
Consult the Control’s instructions for
programming the device in the system.
Fault device features to “Learn” device
“Services” in the control:
- Tamper switch
- Selectable Sensitivity Settings
- Temperature sensing
Temperature sensing range is 0 – 50°C /
32 – 122°F and is always enabled. Program the
system to use the temperature information at
the panel.
High 4.6-7.6m / 15-25 ft.
Medium 3-4.6m / 10-15 ft.
Low 1.5-3m / 5-10 ft.
Lowest 0-1.5m / 0-5 ft.
The RF6GB detector is Factory set at HIGH
sensitivity. Change the sensitivity setting at
the Control Panel.