Maintenance from the palm of your hand
Bluetooth-enabled local display for Searchpoint
Optima Plus and Searchline Excel
Now you can reduce
time and cost by
managing maintenance
from your smartphone
The Optima Excel Local Display (OELD) is a smart junction
box for the Searchpoint Optima Plus and Searchline Excel
infrared detectors for flammable hydrocarbons. The OELD
includes an LCD screen for gas information, a “traffic light”
indicator for at-a-glance detector status, and Bluetooth®
connectivity for simplified, non-intrusive maintenance.
Simply pair the OELD with our intrinsically safe, ruggedized
smartphone; then use the OELD smartphone app to interact
with the gas detector from up to 10 meters (30 feet) away. For
maximum flexibility, the gas detector can be mounted either
directly or remotely to OELD to suit any situation.
— with at-a-glance
assurance of your
gas safety.
Simplified maintenance with familiar smartphone technology
When you pair a smartphone with OELD, you can perform
many tasks for your Searchpoint Optima Plus and Searchline
Excel detectors wirelessly and from a convenient position.
Use the OELD mobile app to specify the target gas, configure
alarm set points, perform one-man calibrations, access event
logs, perform diagnostics, check detector status and more
— with no need to go back and forth to the control room, or
open the enclosure on your gas detector. That means no
hot-work headaches like obtaining permits, declassifying the
area or adding more manpower.
For detectors in hard-to-reach locations such as a duct, you
can position the corresponding OELD remotely in an
easy-to-access location and use the OELD smartphone app
to interact with the detector wirelessly.
At-a-glance visibility
OELD has bright indicator lights visible from a distance,
where green indicates normal operation, yellow indicates
a fault or maintenance and red indicates an alarm. The
LCD screen clearly displays real-time readings on detector
status, including the gas being monitored, the local gas
concentration and units of measurement — so you have easy
access to status information.
Gas detection that fits the way you work
The OELD smartphone app delivers the familiar user
experience you expect — combined with gas detection
technology designed to keep you safe while making your job
easier. It simplifies detector maintenance and is a
cost-effective way to get even more value from your
Searchpoint Optima Plus or Searchline Excel gas detectors.
2

EASE OF MAINTENANCE
• Simplified maintenance with familiar
smartphone technology
• Non-intrusive interaction to reduce time
and safety risk
• Easy access to hard-to-reach detectors
• Know before you go:
pre-empt maintenance issues
OELD SPECIFICATION
MATERIAL
WEIGHT
DIMENSIONS
CABLE ENTRIES
TERMINATION
STORAGE
TEMPERATURE
OPERATIONAL
TEMPERATURE
HUMIDITY
DISPLAY
CONFIGURABLE
DISPLAYED
INFORMATION
VISUAL INDICATION
POWER SUPPLY
INTERFACES
ENVIRONMENTAL
PROTECTION
Marine-grade aluminium alloy or 316 stainless steel with
5-coat painted finish
Aluminium version 2.3 kg (5 lb), stainless steel version 5.0 kg
(11 lb)
159 x 197 x 114 mm (6 ¼ x 7 ¾ x 4 ½ inch)
5 x M25 (ATEX/IECEx version) or 5 x ¾” NPT (cULus version).
One reserved for sensor connection.
3 blanking plugs supplied for unused entries.
2 x pluggable rising-clamp type for connection to gas detector
and field wiring.
Accepts cable sizes of 0.5 to 2.5mm2, 12 to 28 AWG
40 to +65 °C (40 to 149 °F)
40 to +65 °C (40 to 149 °F)
60 to +65 °C (76 to 149 °F) (CU TREX version only)
0 to 99% RH (non-condensing)
LCD module showing digital readout of sensor output, bar chart
representation, units of measurement, status icons for alarm,
maintenance and active Bluetooth connection.
Displayed information fully user-configurable using the OELD
mobile app.
Units of measurement (select from %LEL, mg/m3, g/m3, %Vol,
ppm, mA, A, kppm, LEL.m, dB, dBA, ppm.m)
Gas name (up to 4 alpha-numeric characters)
Measurement range
Green/yellow/red/blue multi-colour backlight to display for
indication of detector and OELD status.
Green (normal) indication can be disabled via app.
18 to 32 Vdc (24 Vdc nominal), <2 W
Bluetooth® (BLE) non-intrusive connection to suitable mobile
device running the OELD mobile app.
Range up to 10 m (30 feet) (mobile device dependant)
Internal RS485 connection to Searchpoint Optima Plus or
Searchline Excel via SHC1 through the SHC Protection Device
IP66 / Type 4X
LOCAL VISIBILITY OF SAFETY ISSUES
• Bright “traffic light” indicator for safety
awareness
• Easier to locate a unit in fault/warning
• Real-time gas readings
OELD SPECIFICATION
SAFETY APPROVALS
MARITIME
APPROVALS*
OTHER APPROVALS
BLUETOOTH
COMMUNICATION
SECURITY
*CONTACT HONEYWELL FOR AVAILABILITY +FLAMEPROOF VERSIONS ONLY
FEATURES
• Robust Aluminium or Stainless steel housing
• Worldwide approvals for hazardous areas
including ATEX, IECEx, cULus
• Green/yellow/red/blue multi-colour
backlight to show status
• Bluetooth® (BLE) range up to 10 m (30 feet)
• Ingress protection IP66 / Type 4X
• Assessed to have no effect on functional
safety of connected gas sensor
• Backward compatible with all versions of
Searchpoint Optima Plus and Searchline
Excel
• Secure access to OELD units can be easily
managed by a primary user via the OELD app
ATEX/IECEx
DEMKO 16 ATEX 1693X
IECEx [UL 16.0066X]
II 2 GD
Ex db IIC T6
Ex tb IIIC T85 °C
Tamb 40 to +65 °C
EN 60079291 Approved Accessory
cULus
Class I, Div 1, A, B, C & D
Class II, Div 1 F & G, Class III, Div 1
Tamb 55 to +65 °C
Temp Code T6
Class I, Zone 1, AEx d IIC T6
Class I, Zone 21, AEx tb IIIC T6
ISA 60079291
CU TREx (Russian Customs Union), Tamb 60 to +65 °C*
CCCF*
Inmetro*
NEPSI+*
PESO+*
Type approved to DNV, BV+, Lloyds+, ABS
EN 60945 (EMC)
IEC 60092504
Bluetooth Certified, Radio Equipment Directive (RED), FCC+,
country-specific wireless approvals
Certificate-based mutual authentication.
Encryption to AES128
CORE APPROVALS
EN 50270: 2015 (EMC)
IEC/EN/UL/CSA 61010 (Electrical Safety)
3

Honeywell Gas Detection
Honeywell is able to provide gas detection solutions to meet the requirements of all applications and industries.
Contact us in the following ways:
Find out more:
www.honeywellanalytics.com
www.raesystems.com
Europe, Middle East, Africa
Life Safety Distribution GmbH
Javastrasse 2
8604 Hegnau
Switzerland
Tel: +41 (0)44 943 4300
Fax: +41 (0)44 943 4398
gasdetection@honeywell.com
Customer Service:
Tel: 00800 333 222 44
(Freephone number)
Tel: +41 44 943 4380
(Alternative number)
Fax: 00800 333 222 55
Middle East Tel: +971 4 450
5800 (Fixed Gas Detection)
Middle East Tel: +971 4 450
5852 (Portable Gas Detection)
www.honeywell.com
Americas
Honeywell Analytics Distribution Inc.
405 Barclay Blvd.
Lincolnshire, IL 60069
USA
Tel: +1 847 955 8200
Toll free: +1 800 538 0363
Fax: +1 847 955 8210
detectgas@honeywell.com
RAE Systems by Honeywell
Phone: 408.952.8200
Toll Free: 1.888.723.4800
Fax: 408.952.8480
Asia Pacific
Honeywell Industrial Safety
7F SangAm IT Tower,
434, Worldcupbuk-ro, Mapo-gu,
Seoul 03922,
Korea
Tel: +82 (0) 2 6909 0300
Fax: +82 (0) 2 2025 0328
India Tel: +91 124 4752700
China Tel: +86 10 5885 8788 3000
analytics.ap@honeywell.com
Technical Services:
EMEA: HAexpert@honey well.com
US: ha.us.service@honeywell.com
AP: ha.ap.service@honeywell.com
OELD_DS01175_01_1016_AMER_EN
Copyright © 2016 Honeywell International Inc.
All rights reserved.