Honeywell OELD Data sheet

Gas Detection
OELD
Bluetooth-enabled local display for Searchline Excel and Searchpoint Optima Plus
OELD SPECIFICATION
MATERIAL
WEIGHT
DIMENSIONS
CABLE ENTRIES
TERMINATION
STORAGE TEMPERATURE
OPERATIONAL TEMPERATURE
HUMIDITY
DISPLAY
CONFIGURABLE DISPLAYED INFORMATION
Marine-grade aluminium alloy or 316 stainless steel with 5-coat painted finish
159 x 197 x 114 mm (6 ¼ x 7 ¾ x 4 ½ inch)
5 x M25 (ATEX/IECEx version) or 5 x ¾” NPT (cULus version). One reserved for sensor connection. 3 blanking plugs supplied for unused entries.
2 x pluggable rising-clamp type for connection to gas detector and field wiring. Accepts cable sizes of 0.5 to 2.5mm
40 to +65 °C (40 to 149 °F)
40 to +65 °C (40 to 149 °F) 60 to +65 °C (76 to 149 °F) (CU TREX version only)
0 to 99% RH (non-condensing)
LCD module showing digital readout of sensor output, bar chart representation, units of measurement, status icons for alarm, maintenance and active Bluetooth connection.
Displayed information fully user-configurable using the OELD mobile app. Units of measurement selectable from:
%LEL, %VOL, ppm, kppm, mg/m
2
, 12 to 28 AWG
3
, g/m3 (point detectors)
LEL.m, ppm.m (open path detectors)
mA, A, dB, DBA (other)
Gas name (up to 4 alpha-numeric characters) Measurement range
VISUAL INDICATION
POWER SUPPLY
INTERFACES
COMPATIBLE GAS DETECTORS
ENVIRONMENTAL PROTECTION
CORE APPROVALS
Green/yellow/red/blue multi-colour backlit display for indication of detector and OELD status. Green (normal) indication can be disabled via app.
18 to 32 Vdc (24 Vdc nominal), <2 W
Bluetooth® (BLE) non-intrusive connection to suitable mobile device running the OELD mobile app. Range up to 10 m (30 feet) (mobile device dependant) Internal RS485 connection to Searchpoint Optima Plus or Searchline Excel via SHC1 through the SHC Protection Device
Searchpoint Optima Plus. Searchine Excel, Searchline Excel CrossDuct, generic 4 to 20 mA devices
IP66 / Type 4X (in accordance with NEMA 250)
EN 50270: 2015 (EMC) IEC/EN/UL/CSA 61010 (Electrical Safety)
1.7"
6.0"
124.2mm
14.4mm
196.9mm
4.5"
2.1"
15.9mm
158.8mm
44.9mm
44.9mm
80.7mm
24.0mm
31.8mm
5.6"
152.4mm
7.8"
0.6"
42.4mm
133.8mm
52.2mm
0.6"
6.1"
1.8"
1.8"
3.2"
0.9"
1.2"
OELD Specifications
OELD SPECIFICATION
ATEX/IECEx DEMKO 16 ATEX 1693X IECEx [UL 16.0066X]
II 2 GD Ex db IIC T6 Ex tb IIIC T85 °C Tamb 40 to +65 °C EN 60079291 Approved Accessory
cULus
SAFETY APPROVALS
MARITIME APPROVALS*
OTHER APPROVALS
Class I, Div 1, A, B, C & D Class II, Div 1 F & G, Class III, Div 1 Tamb 55 to +65 °C Temp Code T6 Class I, Zone 1, AEx d IIC T6 Class I, Zone 21, AEx tb IIIC T6 ISA 60079291
CU TREx (Russian Customs Union), Tamb 60 to +65 °C* CCCF* Inmetro* NEPSI+* PESO+*
Type approved to DNV, BV+, Lloyds+, ABS, EN 60945 (EMC) IEC 60092504
Bluetooth Certified, Radio Equipment Directive (RED), FCC+, country-specific wireless approvals
BLUETOOTH COMMUNICATION SECURITY
*CONTACT HONEYWELL FOR AVAILABILITY +FLAMEPROOF VERSIONS ONLY
Certificate-based mutual authentication. Encryption to AES128
OELD Dimensions
For more information
www.honeywellanalytics.com www.raesystems.com
Europe, Middle East, Africa
Life Safety Distribution GmbH Tel: 00800 333 222 44 (Freephone number) Tel: +41 44 943 4380 (Alternative number) Middle East Tel: +971 4 450 5800 (Fixed Gas Detection) Middle East Tel: +971 4 450 5852 (Portable Gas Detection)
Americas
Honeywell Analytics Distribution Inc. Tel: +1 847 955 8200 Toll free: +1 800 538 0363
RAE Systems by Honeywell Phone: 408.952.8200 Toll Free: 1.888.723.4800
Asia Pacific
Honeywell Analytics Asia Pacific Tel: +82 (0) 2 6909 0300 India Tel: +91 124 4752700 China Tel: +86 10 5885 87883000 analytics.ap@honeywell.com
Technical Services
EMEA: HAexpert@honeywell.com US: ha.us.service@honeywell.com AP: ha.ap.service@honeywell.com
www.honeywell.com
OELD_DS01176_V1_1216_LTR_EN © 2016 Honeywell International Inc.