PRODUCT DATA
GENERAL
These variable frequency drives provide step-less speed control for all open-loop (no speed feedback from motor) applications in HVAC and industrial environments:
Pumps
Fans
Compressors
Conveyors
Lifts
Escalators
Mixers
FEATURES
Most compact size in the market (especially IP54)
Integrated RFI-filters and AC-chokes
Application adapting Start Up Wizard
Application adapting Quick menu
Flexible “ALL-IN-ONE” multipurpose software with
predefined applications
Alphanumeric keypad with memory and backup
functions
Easy “keypad – remote” change with 1 button
Trip free operation with safety switch
Silent motor operation with 10 kHz switching
frequency
Overtemperature ride-through
Power ride-through
Integrated PID controller
Built-in PLC
Integrated PFC (Pump & Fan Cascade) Controller
The best available fully controlled pump cascade
system with special software - Multimaster PFC
SPECIFICATIONS
Mains Connection
Input voltage U
in
380…500 Vac (-15 …+10%) 3~
208…240 Vac (-15 …+10%) 3~ 525…690 Vac (-15 …+10%) 3~
Input Frequency 45...66 Hz Connection to mains Once per minute or less
Motor Connection
Output voltage 0…U
in
Continuous output current:
Low overload
I
L
: +40°C, overload 1.1 x IL
(for fan/pump)
(1 min / 10 min)
High overload
I
H
: +50°C, overload 1.5 x IH
(for machines)
(1 min / 10 min)
Starting Torque:
Low overload
150%
(for fan/pump)
High overload
200%
(for machines)
Starting Current 2xI
H
for 2s/20s
Output Frequency 0…320 Hz; up to 7200 Hz with
special software
Frequency resolution 0.01 Hz
NXS VARIABLE FREQUENCY DRIVES
EN0B-0620GE51 R1107 2
Control Characteristics
Control Method Frequency Control U/f, Open-
Loop Sensorless Vector Control
Switching Frequency:
FR4 – FR6 (1.1-30kW)
1...16 kHz;
NXS0003…- NXS0061… Default: 10 kHz (no derating)
FR7 – FR9 (37-160 kW)
1…10 kHz
NXS0072…- NXS0310… Default: 3.6 kHz
Frequency reference:
Analogue input Resolution 0.1% (10 bit),
accuracy ±1%
Keypad reference Resolution 0.01 Hz
Field Weakening point 8…320 Hz Acceleration time 0…3000 sec Deceleration time 0…3000 sec Braking torque DC-brake: 30%*TN (without
brake option)
Ambient Conditions
Ambient operating Temperature:
Low overload
-10°C (no frost)…+45°C
(for Fan/Pump)
(with 24 h average +40°C)
Storage temperature -40…+70°C Relative humidity 0…95% RH, non-condensing,
non-corrosive, no dripping
water Air quality: Chemical vapors IEC 721-3-3, unit in operation,
class 3C2 Mechanical particles IEC 721-3-3, unit in operation,
class 3S2
Altitude 100% load capacity (no
derating) up to 1000 m
-1% derating for each 100 m
above 1000 m; max. 3000 m
Relative humidity 0…95% RH, non-condensing,
non-corrosive, no dripping
water
Vibration: 5...150 Hz EN50178/EN60068-2-6 Displacement amplitude 1 mm
(peak) at 5...15.8 Hz Max acceleration amplitude
1 G at 15.8...150 Hz
Shock: UPS Drop Test (for applicable EN50178, IEC 68-2-27 UPS weights) Storage and shipping: max
15 G, 11 ms (in package)
Enclosure class IP21 : NXS___ V35A2 IP54 : NXS___ V35A5
Electro Magnetic Compatibility (EMC)
Immunity Complies with EN50082-1, -2,
EN61800-3
Emissions:
Standard in all EMC-level H: EN 61800-3
(2004) Cat C2, EN 55011 Class A
Integrated option in: EMC level C: EN 61800-3 FR4 – FR6 (1.1-30kW) (2004) Cat C1, EN 55011 NXS0003…- NXS0061… Class B
Safety
EN50178, EN60204-1, CE, GOST R, IEC 61800-5 (see unit nameplate for more detailed approvals)
Control Connections
Analogue input voltage 0...+10 V, Ri = 200 kΩ,
resolution 10 bit, accuracy ±1%
Analogue input current 0(4)…20 mA, Ri = 250
differential resolution 0.1%, accuracy ±1%
Digital inputs 6 positive logic; 18…24 Vdc
Auxiliary voltage +24 V, ±15%, max. 100 mA
Output reference voltage +10 V, +3%, max. load 10 mA
Analogue output 0(4)…20 mA; RL max. 500Ω;
resolution 16 bit; accuracy ±1%
Relay outputs 2 programmable change-over
relay output (1 NO/NC and 1 NO). Switching capacity: 24 Vdc / 8 A, 250 Vac / 8 A, 125 Vdc / 0.4 A. Min. switching load: 5 V / 10 mA
Digital output Open collector output, 50 mA /
48 V
Motor thermistor Input R
TRIP
= 4.7 k (PTC),
electrically isolated
NXS VARIABLE FREQUENCY DRIVES
3 EN0B-0620GE51 R1107
Protection
Overvoltage protection 911 Vdc Undervoltage protection 333 Vdc Earth-fault protection In case of earth fault in motor
or motor cable, only the frequency converter is protected
Input phase supervision YES Motor phase supervision YES Overcurrent protection Trip limit 4.0*I
H
instantaneously
Unit overtemp. protection YES Motor overload protection YES
Motor stall protection
YES
(fan/pump blocked)
Motor underload prot. YES (pump dry / belt broken
detection)
Short-circuit protection of +24 V and +10 V YES
reference voltages
PRODUCT IDENTIFICATION CODE
NXS 0003 V3 5 A 2 H 1
Brake chopper
0 = No brake chopper
1 = Internal brake chopper
EMC emission level
H = Fulfils standard EN61800-3 [2004] Cat C2
T = Fulfils standard EN61800-3 for IT Networks
C = Fulfils standard EN61800-3 [2004] Cat C1
(exception : Radiated emissions of the IP21 units
meet only the requirements of C2)
Enclosure class
2 = IP21
5 = IP54
Control keypad
A = Standard (alpha-numeri c)
G = Graphic display (for Chinese and Cyrillic letters)
Nominal mains voltage
2 = 230 (208-240) Vac
5 = 400 (380-500) Vac
6 = 690 (525-690) Vac
Input Phases
V3 = 3 Phase
Nominal current (low overload)
0003 = 3A etc.
Product range: NXS
Fig. 1. Product Identification Code
NXS VARIABLE FREQUENCY DRIVES
EN0B-0620GE51 R1107 4
MODELS IN STANDARD SELECTION
Mains voltage 3~ 380-500 V, 50/60 Hz, EMC class H, Series NXS
Motor shaft power Loadability
400 V supply
Low High
Frequency converter type
Low
overload
(for pump /
fan) 40°C P
[kW]
High
overload (for
machines)
50°C P [kW]
Rated
con­tinuous current
I
L
[A]
10%
over-
load
current
[A]
Rated
con­tinuous current
I
H
[A]
50%
over-
load
current
[A]
Mechanical
size
enclosure /
protection class
Dimensions
WxHxD
[mm]
Weight
[kg]
NXS0003V35A2H1
1.1
0.75
3.3
3.6 2.2 3.3 FR4/IP21 128x292x190 5
NXS0004V35A2H1
1.5
1.1
4.3
4.7 3.3 5.0 FR4/IP21 128x292x190 5
NXS0005V35A2H1
2.2
1.5
5.6
6.2 4.3 6.5 FR4/IP21 128x292x190 5
NXS0007V35A2H1
3
2.2
7.6
8.4 5.6 8.4 FR4/IP21 128x292x190 5
NXS0009V35A2H1
4
3
9
9.9 7.6 11.4 FR4/IP21 128x292x190 5
NXS0012V35A2H1
5.5
4
12
13.2 9 13.5 FR4/IP21 128x292x190 5
NXS0016V35A2H1
7.5
5.5
16
17.6 12 18 FR5/IP21 144x391x214 8.1
NXS0022V35A2H1
11
7.5
23
25.3 16 24 FR5/IP21 144x391x214 8.1
NXS0031V35A2H1
15
11
31
34 23 35 FR5/IP21 144x391x214 8.1
NXS0038V35A2H1
18.5
15
38
42 31 47 FR6/IP21 195x519x237 18.5
NXS0045V35A2H1
22
18.5
46
51 38 57 FR6/IP21 195x519x237 18.5
NXS0061V35A2H1
30
22
61
67 46 69 FR6/IP21 195x519x237 18.5
NXS0072V35A2H0
37
30
72
79 61 92 FR7/IP21 237x591x257 35
NXS0087V35A2H0
45
37
87
96 72 108 FR7/IP21 237x591x257 35
NXS0105V35A2H0
55
45
105
116 87 131 FR7/IP21 237x591x257 35
NXS0140V35A2H0
75
55
140
154 105 158 FR8/IP21 291x758x344 58
NXS0168V35A2H0
90
75
170
187 140 210 FR8/IP21 291x758x344 58
NXS0205V35A2H0
110
90
205
226 170 255 FR8/IP21 291x758x344 58
NXS0260V35A2H0
132
110
261
287 205 308 FR9/IP21 480x1150x362 146
NXS0310V35A2H0
160
132
300
330 245 368 FR9/IP21 480x1150x362 146
NXS0003V35A5H1
1.1
0.75
3.3
3.6 2.2 3.3 FR4/IP54 128x292x190 5
NXS0004V35A5H1
1.5
1.1
4.3
4.7 3.3 5.0 FR4/IP54 128x292x190 5
NXS0005V35A5H1
2.2
1.5
5.6
6.2 4.3 6.5 FR4/IP54 128x292x190 5
NXS0007V35A5H1
3
2.2
7.6
8.4 5.6 8.4 FR4/IP54 128x292x190 5
NXS0009V35A5H1
4
3
9
9.9 7.6 11.4 FR4/IP54 128x292x190 5
NXS0012V35A5H1
5.5
4
12
13.2 9 13.5 FR4/IP54 128x292x190 5
NXS0016V35A5H1
7.5
5.5
16
17.6 12 18 FR5/IP54 144x391x214 8.1
NXS0022V35A5H1
11
7.5
23
25.3 16 24 FR5/IP54 144x391x214 8.1
NXS0031V35A5H1
15
11
31
34 23 35 FR5/IP54 144x391x214 8.1
NXS0038V35A5H1
18.5
15
38
42 31 47 FR6/IP54 195x519x237 18.5
NXS0045V35A5H1
22
18.5
46
51 38 57 FR6/IP54 195x519x237 18.5
NXS0061V35A5H1
30
22
61
67 46 69 FR6/IP54 195x519x237 18.5
NXS0072V35A5H0
37
30
72
79 61 92 FR7/IP54 237x591x257 35
NXS0087V35A5H0
45
37
87
96 72 108 FR7/IP54 237x591x257 35
NXS0105V35A5H0
55
45
105
116 87 131 FR7/IP54 237x591x257 35
NXS0140V35A5H0
75
55
140
154 105 158 FR8/IP54 291x758x344 58
NXS0168V35A5H0
90
75
170
187 140 210 FR8/IP54 291x758x344 58
NXS0205V35A5H0
110
90
205
226 170 255 FR8/IP54 291x758x344 58
NXS0260V35A5H0
132
110
261
287 205 308 FR9/IP54 480x1150x362 146
NXS0310V35A5H0
160
132
300
330 245 368 FR9/IP54 480x1150x362 146
NXS VARIABLE FREQUENCY DRIVES
5 EN0B-0620GE51 R1107
HONEYWELL EMC CLASSES AND MARKET REQUIREMENTS
Fig. 2. EMC classes in practice
EMC levels
Hospital Airport Residential Area Commercial Light Industry Area Heavy Industry
C O O
H R R R R O O
L R R
T R (IT Network)
O = optional, R = required
C = EN61800-3 [2004] Category C1 (integrated option up to 30 kW)
H = EN61800-3 [2004] Category C2 (standard in NXS)
L = EN61800-3 [2004] industrial requirements fulfilled (NXS units in 200 - 400 kW)
T = EN61800-3 [2004] IT network (e.g. ships) requirements fulfilled, size FR4-FR8 inverters
(NXS0003-NXS0205) can be easily converted to T-class from standard EMC class. Instructions for
this can be found from NX Series User’s Manual included in all NXS deliveries.
1 2 3 4 5 6
NXS VARIABLE FREQUENCY DRIVES
EN0B-0620GE51 R1107 6
MECHANICAL DIMENSIONS AND MOUNTING
The frequency converter can be mounted in either vertical or horizontal position on the wall or on the back plane of a cubicle. It shall be fixed with four screws (or bolts, depending on the unit size). Lift units bigger than FR7 out of the package using a jib crane.
Fig. 3. NXS FR4 – FR8 (NXS0003… - NXS0205...) dimensions
Dimensions [mm]
Type
W1 W2 H1 H2 H3 D1
E1 E2*
NXS0003—NXS0012 128 100 327 313 292 190 7 3 x 28.3 NXS0016—NXS0031 144 100 419 406 391 214 7 2 x 37 1 x 28.3 NXS0038—NXS0061 195 148 558 541 519 237 9 3 x 37 NXS0072—NXS0105 237 190 630 614 591 257 9 3 x 47 NXS0140—NXS0205 285 255 755 732 721 312 9 3 x 59
W1
W2
H1 H2
Ø
D1
H3
fr5ip21.fh8
Ø
Loading...
+ 12 hidden pages