Honeywell HUL430 Instruction Manual

Air Purier
Heater
Fan
Humidier
Visible Cool Mist
• With ultrasonic humidification, a nebulizer vibrates at ultrasonic frequency, breaking water droplets into fine mist
• Be careful not to over-humidify: Exceeding a 60% humidity level can cause condensation around unit, on walls and on surfaces; if this occurs, open a door and turn the humidifier off or to a lower setting
Instruction Manual
DESIGNER SERIES COOL MIST HUMIDIFIER
HUL430 series
Humidity Level
• The ideal indoor humidity level is 4060%
• Use a Honeywell humidity monitor (HHM10 or H10C) to check your indoor
humidity level (not included)
For questions and information about this humidifier
Visit www.HoneywellPluggedIn.com or Call 800-477-0457
2 3
1. The humidifier should ALWAYS be placed
on a firm, flat, waterproof surface at least four feet (1.2m) away from bedside, 12 inches (30cm) from the wall and out of reach of children and pets. Be sure the humidifier is in a stable position and the power cord is away from heated surfaces and out of the way to prevent the humidifier from being overturned.
2. The humidifier should not be left unattended,
especially in a closed room since air could become saturated and leave condensation on walls and furniture. If room becomes saturated, open the door and turn the humidifier off or down.
3. Before using the humidifier, extend the
cord and inspect for any signs of damage. DO NOT use the unit if the cord has been damaged. DO NOT operate with power cord coiled or with twist tie in place.
4. The humidifier has a polarized plug (one
blade is wider than the other) as a safety feature. This plug will fit into a polarized outlet only one way. If the plug does not fit fully into the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. DO NOT attempt to defeat this safety feature.
5. CAUTION: To avoid fire or electric shock
hazard, plug the humidifier directly into a 120V AC electrical outlet. To avoid risk of fire, electric shock, or personal injury, DO NOT use an extension cord or power strip.
6. The humidifier should ALWAYS be
unplugged and emptied when not in operation or while being cleaned. Shut off and unplug humidifier before moving. DO NOT move or tilt humidifier while it is in operation. Plug and unplug unit with dry hands. NEVER pull by cord.
7. DO NOT operate the humidifier without
water. Turn off and unplug unit when tank is empty and the reset light is on.
8. Humidifier requires regular cleaning.
Refer to and follow cleaning instructions.
9. DO NOT operate outdoors; this humidifier is
intended for indoor residential use only.
10. DO NOT cover or insert objects into any
openings on the unit.
11. DO NOT block intake or output vents.
12. DO NOT attempt to repair or adjust any
electrical or mechanical functions on this humidifier. Doing so will void your warranty.
13. DO NOT place in direct sunlight, high
temperature areas or near computers or sensitive electronic equipment.
14. DO NOT touch the nebulizer while the unit
is plugged in, as burns could result.
15. DO NOT add any medications, inhalants,
scented products or essential oils into the Base, Water Reservoir or Water Tank
16. For Residential Use Only.
SAVE THESE INSTRUCTIONS.
IMPORTANT
SAFETY INSTRUCTIONS
READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS HUMIDIFIER
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following:
2
12
1
13
14
16
15
17
3
4
5
7
6
8
1. Tank Handle
2. Mist Outlet
3. Water Tank
4. Housing
5. Water Window
6. Mist Level Indicators
7. Refill Light
8. Mist Control Wheel
9. Tank Light Button
10. Essential Oil Pad
11. Essential Oil Tray
12. Tank Cap
13. Gasket
14. Float
15. Reservoir
16. Nebulizer
17. Tank Light
COMPONENTS
GETTING TO KNOW YOUR COOL MIST HUMIDIFIER
How it Works
Water is released from the Water Tank into the Reservoir. A Nebulizer vibrates at ultrasonic frequency, breaking the water into a fine mist. The mist is quietly propelled by a fan up a vertical Mist Chamber to the Mist Outlet where the cool, visible mist enters the room. This humidifier will shut off when the water level is low or when the tank is removed from the base.
9
10
11
4 5
1
1
2 3
$
1
2
3 4
NOTE: Position humidifier to direct mist output away from walls, furniture and bedding.
1. Power On: With the Mist Control Wheel in the OFF position, plug the filled humidifier into a polarized 120V outlet.
CAUTION: To avoid electric shock, DO NOT plug humidifier into an outlet with wet hands.
2. Slide the Control Wheel up or down to reach desired humidity level. More lights mean more mist output. To turn off humidifier, turn Control Wheel down until it clicks and all lights turn off.
3. Humidity Level: When a comfortable humidity level is reached, turn Control Wheel to a lower setting. A comfortable humidity level is between 4060%. Consider using a humidity monitor to display current room humidity and temperature.
CONDENSATION: If you notice condensation on the walls, windows or around the humidifier, the humidity level is too high. Turn off humidifier until humidity level drops.
4. Tank Light: Press the Tank Light button to control the light in the Water Tank. There are three settings: Bright, Dim, or Off.
Using The Essential Oil Tray
This humidifier features an Essential Oil Tray that can be used with your favorite essential oil for added enjoyment. This not a diffuser - the oil does not come in contact with water and is passively evaporated into the air. Essential oil is sold separately.
1. Slide the tray open.
2. Add a few drops of essential oil to the Pad.
WARNING: DO NOT pour any liquids into the Mist Outlet. DO NOT ADD LIQUID INHALANTS, ESSENTIAL OILS OR ANY ADDITIVES TO THE WATER TANK. DOING SO CAN HAVE ADVERSE EFFECTS ON THE HUMIDIFIER AND VOID THE WARRANTY.
3. To clean the Essential Oil Tray, gently wipe residue from the Tray.
Daily Maintenance
For best results, use fresh clean water every day.
4
USING YOUR HUMIDIFIER
1
2 3
SETTING UP YOUR HUMIDIFIER
Unpack the Humidifier
Keep this instruction manual for reference
Remove packaging materials.
1. Remove twist tie and extend power cord. Place on a firm, level, water resistant surface a minimum of 12” (30cm) from any walls.
Hard Water and White Dust
High mineral content in your water, also known as hard water, may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. This mineral residue is commonly referred to as white dust. The higher the mineral content (hardness) of your water, the greater the potential that an ultrasonic humidifier may produce white dust.
White dust is not a result of a defect or flaw in the humidifier. It is a result of the amount of minerals suspended in the water you are using.
FILLING / REFILLING
NOTE: Tank should be carried using two hands; one hand on the Tank Handle and the other supporting the bottom of the Tank.
Kaz USA, Inc. will not accept responsibility for property damage caused by water spillage.
This humidifier holds 1.25 gallons (4.5 liters) of water (tank and reservoir combined).
Filling
1. Remove Water Tank and turn upside down. Remove Tank Cap by turning counter clockwise (left). Fill Tank with cool water. DO NOT fill with warm or hot water.
2. Replace Tank Cap by turning clockwise (to right) to screw back in place. DO NOT over-tighten.
3. Place Tank in humidifier Housing. Water will drain from the Tank into the Reservoir when the Plunger is engaged.
4. When the Tank is empty, the humidifier will shut off and the refill light will turn on. Refill the tank following the instructions above.
6 7
CLEANING YOUR HUMIDIFIER (continued)
Disinfecting
Before starting the disinfecting process, follow Steps 12 in Before Cleaning section.
NOTE: Bleach may stain clothes. It is recommended to wear rubber gloves during this process to protect your hands.
1. Add 1 teaspoon of bleach to 1 gallon (3.8L) of water and add to Water Tank.
2. Replace Tank Cap and swish bleach solution in Tank to coat the inside of the Water Tank.
3. Place Tank in Housing, allowing solution to drain into the Water Reservoir. Soak for 20 minutes
4. Remove Water Tank and empty solution into sink.
5. Pour solution from the Reservoir into the sink. Be sure to pour out of the back of the unit to avoid leaking into control panel. Rinse Tank and Reservoir area with clean water until the smell of bleach is gone.
CAUTION: Do not submerge Housing in water. Doing so will damage the humidifier and void the warranty.
End of Season Cleaning and Storage
Follow the cleaning instructions when the humidifier will not be used for at least one week, or at the end of the season.
At the end of the season, remove any accessories and discard. Allow the humidifier and all components to dry completely before storing.
DO NOT store humidifier with water inside the Reservoir or Water Tank. Pack unit safely and store in cool, dry location.
CLEANING YOUR HUMIDIFIER
To keep your humidifier running efficiently, clean it regularly. Weekly cleaning is recommended. All maintenance should be done in the kitchen or bathroom on a water-resistant surface near a faucet.
To properly clean your humidifier, we recommend the separate processes of Scale Removal and Disinfecting.
These two processes must be performed separately.
Before Cleaning
1. Turn off and unplug humidifier. Never clean the humidifier when it is running.
2. Remove Water Tank and empty completely. Remove any accessories from the water tank.
Scale Removal
Follow steps 12 in Before Cleaning section, then follow the additional steps below.
1. Pour 2 cups (.5 liters) of undiluted distilled white vinegar into the Water Tank
2. Replace Tank Cap and swish vinegar in Tank to coat the inside of the Water Tank..
3. Place Tank in Housing, allowing vinegar to drain into the Water Reservoir. The vinegar will loosen mineral buildup on the Nebulizer and Float, and in the bottom of the Tank. Soak for 20 minutes.
4. Remove Water Tank and empty vinegar into sink.
5. Gently wipe Nebulizer and Reservoir area with a soft cloth to remove loosened minerals. NOTE: Nebulizer is fragile. Do not apply extreme pressure.
6. Pour vinegar from the Reservoir into the sink. Be sure to pour out of the back of the unit to avoid leaking into the control panel. Rinse Tank and Reservoir area with clean water until the smell of vinegar is gone.
CAUTION: Do not submerge Housing in water. Doing so will damage the humidifier and void the warranty.
$
2
1
6
2
5
1
4
V
2C
4
5
2
(3,8 l)
B
1 tsp
W
1 Gal.
1
3
3
8 9
PROBLEM POSSIBLE CAUSE SOLUTION
No lights • Unit not plugged in
• Unit is not turned on
• Plug unit in
• Turn unit on
Power is on and little or no mist is produced
• No water in Tank
• Mineral deposits on Nebulizer
• Power setting may be too low
• Fill Water Tank
• Clean Nebulizer (Refer to Cleaning Your Humidifier section)
• Turn Control Wheel to higher setting
Water leaks from Base • Tank may be damaged
• Tank Cap is not tight
• Tank Cap Gasket may be missing
• Check for cracks on tank and contact Consumer Relations to replace, if necessary.
• Tighten Tank Cap
• Check to see if Gasket is attached to inside of Cap; contact Consumer Relations for replacement
Condensation on windows and walls,or area around humidifier is damp
• Mist intensity is set too high for room size or current humidity level
• Humidifier may be too close to wall or window
• Decrease mist output to low setting or open door to the room
• Move humidifier away from wall or direct mist output away from wall or window
CONSUMER RELATIONS
For questions, technical support or to order replacement parts, contact Consumer Relations. We are here to help. Call us toll-free at: 18004770457
E-mail: consumerrelations@kaz.com Or visit our website at: www.HoneywellPluggedIn.com
Please be sure to specify Model number HUL430. NOTE: IF YOU EXPERIENCE A PROBLEM, PLEASE CONTACT CONSUMER RELATIONS FIRST OR SEE YOUR
WARRANTY. DO NOT RETURN TO THE ORIGINAL PLACE OF PURCHASE. DO NOT ATTEMPT TO OPEN THE MOTOR HOUSING YOURSELF, DOING SO MAY VOID YOUR WARRANTY AND CAUSE DAMAGE TO THE HUMIDIFIER OR PERSONAL INJURY.
If your Humidifier is not working properly, refer to the following:
TROUBLESHOOTING SPECIFICATIONS
Electrical rating: 120V, 60 Hz. 0.4A Capacity: 1.25 gallons (4.7 L)
If you experience a problem, please contact Consumer Relations. Do not return this humidifier to the original place of purchase.
This device complies with Part 18 of the FCC rules.
Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment. This equipment has been tested and found to comply within the limits for Consumer ISM equipment, pursuant to Part 18 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference with radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio TV technician for help.
2 YEAR LIMITED WARRANTY
You should first read all instructions before attempting to use this product.
A. This 2 year limited warranty applies to repair or replacement of product found to be defective in material or
workmanship. This warranty does not apply to damage resulting from commercial, abusive, unreasonable use or supplemental damage. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty. KAZ IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL
DAMAGES OF ANY NATURE, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential
damages or limitations on how long an implied warranty lasts, so the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you also may have other rights which vary from jurisdiction to jurisdiction. This warranty applies only to the original purchaser of this product from the original date of purchase.
B. At its option, Kaz will repair or replace this product if it is found to be defective in material or workmanship. C. This warranty does not cover damage resulting from any unauthorized attempts to repair or from any use
not in accordance with the instruction manual.
D. This warranty does not cover the filters, pre-filters, UV bulbs or other accessories (if included) except for
material or workmanship defects. Call us toll-free at 18004770457 or e-mail: consumerrelations@kaz.com Please be sure to specify a model number located on the box and the back and bottom of your unit.
Loading...