Honeywell HU-30 Installation/operation Instruction Manual

Installation & Operation Instruction Manual
HU-30 Desktop Water Purifier
Honeywell Environmental & Combustion Controls (Tianjin) Co., Ltd.
Content
Important Notes for Users ------------------------------------------ 1
Safety Notices --------------------------------------------------------- 1
Technical Parameter------------------------------------------------- 2
Parts --------------------------------------------------------------------- 3
Usage Method --------------------------------------------------------- 4
Electronic device and application--------------------------------- 4
Important Notes for Users
Safety Notices
1
The user should engage professional installation staff and use the water purifier in strict conformity with the installation and usage instructions as described in this “Installation & Operation Instruction Manual” (hereinafter called “Instruction Manual”), otherwise our company would not be liable for any financial or legal responsibilities in relation to damage or leakage of the water purifier as a result of failure to install or use it in accordance with the Instruction Manual.
• Regularly inspect the water purifier and water pipe parts to ensure that there are no water leakage;
• The water purifier is designed for home use only; it may not be suitable for use in other premises;
• Repair and maintenance of the water purifier and replacement cartridge or parts should be carried out using replacement parts approved by Honeywell Environmental and Automated Control Products (Tianjin) Co., Ltd. Quality issues, reduced perfor­mance or loss or damage to property arising from the use of unauthorized parts or accessories would not be covered by warranty.
• Repair, maintenance and replacement of cartridge for the water purifier are charge­able services.
• Municipal tap water which is compliant with GB5749 should be used for the water purifier;
• Do not under any circumstances install the water purifier on water-supply pipelines with a water pressure in excess of 0.6MPa. If the water pressure for inlet water exceeds 0.6 Mpa, pressure-reduction valve (to be separately purchased) must be installed;
• Temperature of inlet water should be 5~38°C. Inlet water temperature exceeding 38°C may damage the sealing parts and cause leakage. Inlet water temperature below 5°C may cause frosting and result in cracks in the water pipe or cartridge, which in turn leads to water leakage;
• Do not use decontaminating agent, detergent, diluting agent, benzene, alcohol and kerosene, etc. They will cause cracks to form as well as de-coloration;
• Do not install the water purifier in places under direct sunlight or which are exposed to hazardous chemicals, or in any place that may make it susceptible to fall or impact, thus causing damage to it;
• The water purifier should be placed far away from any heat sources, especially gas stoves (the latter will cause it to undergo heat-deformation or experience breakdown);
• Do not place the water purifier upside-down during installation or change of cartridge in order to prevent water from flowing onto the circuit board and damaging the electronic components;
• It is essential to screw the upper cover tightly and ensure that there are no gaps in order to prevent leakage or breakdown of the water purifier;
• Do not use the water purifier after removing the outlet water pipe; otherwise it may experience leakage or breakdown.
Operation Instruction
Technical Parameter
Flow rate
1.5 L/min
Filtration composition of cartridge
Granular active carbon, ultrafiltration membrane
Applicable inlet water pressure
0.07 MPa ---0.6 MPa
Rated total purified water
1500 L
Product gross weight
Dimension
Height 275 mm x Diameter 136.6 mm
Inlet water requirements
Municipal tap water, GB5749-2006 compliant
2
• Regularly check the water purifier and water pipe parts to ensure that there is no water leakage;
• Drain water for 5-10 seconds if the water purifier has not been in use for 24 hours. If it has not been used for more than 5 days (3 days in the case of summer), drain water for 2 to 3 minutes before resuming usage. Once the cartridge is in use it cannot be left idle for prolonged period of time, especially during summer. Generally the idling period should not exceed 14 days. If so, change of cartridge is recommended;
• If filtered water is to be obtained and stored, pour it into a clean vessel and cover the vessel tightly. Place the vessel in the refrigerator. Water stored in this manner may be preserved for only two days.
• Immediately cut off the water inlet for the water purifier (by turning the water segregator to “TAP” position) and promptly contact the service provider in any of the following circumstances:
If there is water leakage for the water purifier’s pipe or relevant parts; If there are other abnormal phenomena or breakdowns
1.54 Kg
* The rated total purified water volume is effective treatment volume spiked at full
process in accordance with of the Ministry of Health’s inspection provisions. The actual treatment volume may vary according to the local water quality and usage environment.
* Flow rate: The actual situation may vary according to the usage environment, water
pressure and water quality.