Lire ces consignes avant l’utilisation de l’appareil et les conserver
ES
Aire Acondicionado Portátil
Manual del Propietario
Lea y guarde estas instrucciones antes de usar la unidad
Model / Modèle / Modelo:
HF08CESWK / HF08CESVWK
HF10CESWK / HF10CESVWK
Customer Support:
Assistance Au Client:
Servicio de atencion a clientes:
Web: www.jmatek.com
USA: 1-800-474-2147 | usinfo@jmatek.com
CANADA^: 1-888-209-0999 | canadainfo@jmatek.com
^ Canada Customer Support service available for models sold in Canada only.
^ Le Service Client Canadien est disponible uniquement pour les modèles vendus sur le territoire Canadien.
^ Servicio de Atención A Clientes en Canadá disponible solo para modelos vendidos en Canadá.
SMART PORTABLE AIR CONDITIONER WITH WIFI CONNECTIVITY & VOICE CONTROL
For Models: HF08CESVWK / HF10CESVWK Smart Portable Air Conditioner with WiFi
Connectivity
The Smart Portable Air Conditioner has added features to allow you to operate the Air
Conditioner remotely using a smart device, and to use voice commands through an
Amazon Echo device, to control the unit.
Set up the Honeywell Air Comfort App on your smart phone or tablet to connect the
Honeywell Smart Portable Air Conditioner for WiFi and Voice control (only available for
Smart Portable Air Conditioner models).
1. Download the Honeywell Air Comfort App User Manual from the below link:
2. Download the Honeywell Air Comfort App on your smart phone or tablet.
iOS 9.0 or later
SEARCH “HONEYWELL AIR COMFORT”
Android 4.3 or later
IMPORTANT: A 2.4 GHz Wi-Fi network is required for proper connection and operation
between the Portable Air Conditioner and the App.
NOTE: The Smart Portable Air Conditioner does not have to be connected to the
Honeywell Air Comfort App to function. You can still operate manually using the
unit’s control panel.
EN
SAFETY
READ AND SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS. READ CAREFULLY AND
KEEP FOR FUTURE REFERENCE. IN CASE THERE IS ANY
INCONSISTENCY OR CONFLICT BETWEEN THE ENGLISH
VERSION AND ANY OTHER LANGUAGE VERSION OF THE
CONTENT OF THIS MATERIAL, THE ENGLISH VERSION
SHALL PREVAIL.
WARNING:
•
DO NOT operate the unit with a damaged plug or loose wall
outlet. If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
DO NOT cover the air intake and exhaust when in use.
•
DO NOT place objects on or sit on the unit.
•
Always turn off and unplug the unit when cleaning or
servicing.
•
DO NOT use the appliance if it is damaged.
•
If service is needed contact an authorized service agent.
•
Unplug the unit when stored or not in use.
•
DO NOT pull or carry the appliance by the power cord.
•
DO NOT pinch the power cord in the door and DO NOT pull
it along edges or sharp corners.
•
DO NOT run the power cord under carpeting and rugs.
•
Use caution to prevent tripping on cord.
•
DO NOT use the device in the following cases:
- Near a fire source
- In areas where gasoline, paint or other flammable
goods are stored
- In an area where the water can be projected
•
DO NOT touch the plug or the device with wet hands.
•
Basic safety precautions should always be followed when
using electrical appliances.
EN
SAFETY (CONTINUED)
This appliance has been manufactured for use in domestic
•
environments and should not be used for other purposes.
Only use the installation kit provided to install this unit.
•
DO NOT attempt to extend the hose or install this unit
using other methods other than that shown in this
manual. Improper installation will void any existing
warranties.
DO NOT use an extension cord with this unit.
•
This appliance can be used by children aged from 8 years
•
and above, and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Never insert your fingers or rods into the air outlet. Take
•
special care to warn children of these dangers.
The manufacturer is not liable for injury caused to
•
persons or property damage due to non-compliance
with maintenance instructions and improper use of the
appliance.
The appliance shall be installed in accordance with national
•
wiring regulations.
The appliance is not to be used by persons (including
•
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction.
Children should be supervised to ensure that they do not
•
play with the appliance.
EN
THANK YOU
Congratulations on your purchase of this Honeywell Portable Air Conditioner.
Regarding the information pertaining to the installation, handling, servicing, cleaning and disposal
of the appliance, please refer to the below paragraph of the manual.
USER TIPS
Portable Air Conditioners are ideal for spot cooling. The compressor, condenser and evaporator
are housed in a compact unit. The air is dehumidified and cooled while a flexible hose sends heat
outside. The Portable Air Conditioner includes a window venting kit.
No permanent installation is needed. The unit is easy to move from room to room and offers a truly
flexible air conditioning solution.
Auto Evaporation System - The unit automatically evaporates the condensate through the hose.
There is no need to empty the drainage tank except in humid conditions. Read and follow the
instructions carefully.
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air
conditioner or dehumidifier. If the product is being used with the fan function only, an open window
could improve air circulation.
Cooling and Dehumidifying
Operation
Important:
Before installing the unit, place it UPRIGHT for 1 hour before use to allow the refrigerant to stabilize.
Air outlet automatically opens when the unit is turned on, and automatically closes when the unit is
turned off. Manually adjust the air vent located at the top of the unit to adjust the direction of air flow.
Follow installation instructions to set up the unit.
•
Plug the unit into a properly grounded circuit. DO NOT plug into an extension cord.
•
EN
1
Fan Operation
PARTS DESCRIPTION
1
2
3
6
5
7
°F
°C
15
4
14
1) Control Panel9)Upper Rubber Drain Plug
2) Air Outlet10) Lower Dust Filter
3) Handle11) Drain Tube
(Dehumidifying Mode)
(For Continuous Drain)
8
9
10
11
12
13
4) Casters12) Drain Plug Cap
5) Remote Control13) Lower Rubber Drain Plug
6) Hose Connector14) Drain Pan
7) Cord Winder15) Power Supply Cord
8) Upper Dust Filter
EN
(Air Conditioning Mode)
2
INSTALLATION
It is important that the installation instructions below are followed for successful installation of this
Portable Air Conditioner. Please call Customer Support if you have any difficulties or queries
regarding these installation procedures.
3. Hose Connector(1 Piece)7. Foam Seal (adhesive) (2 Pieces)
4. Drain Pan(1 Piece)8. Foam Seal (non-adhesive) (1 Piece)
Installation Steps:
Window bracket panel adapter, hose and hose connector are pre-assembled inside the package.1.
245
x1x1x1
7
x1
x2x1
x1x2
8
2. Adjust the window bracket as per width or height of your window and insert the plastic pin to
fix at the desired position. There is a hole where the hose will be inserted later. Make sure this
hole is not blocked.
Plastic Pin
Hole for Window Bracket
26.6", 36.2" to 52"
(67.5 cm, 92 cm to 132 cm)
Panel Adapter and Hose
3EN
INSTALLATION (CONTINUED)
Note: After setting the window bracket to the size of your window, please remove it from the window
and follow the instructions below.
3. Connect the hose to the rear exhaust outlet on the back of the unit. Slide-in the hose connector
then rotate clockwise until it is locked in place.
Hose:
Dia. 5.9" (15 cm)
Length: 10.6" to 59" (27 cm to 150 cm)
4. Connect the window bracket to the window bracket panel adapter. Ensure that all connections are
tight and installed properly.
Cut the Foam Seal (adhesive) to the proper length and attach them to the window sash
5.
and frame.
Horizontal Sliding WindowVertical Sliding Window
4EN
INSTALLATION (CONTINUED)
6. Connect the window bracket to the window.
Horizontal Sliding Window
Vertical Sliding Window
7. Cut the Foam Seal (non-adhesive) to the window length. Stuff the Foam Seal (non-adhesive)
between the inner window sash and the outer window glass to prevent air and insects from
getting into room.
Horizontal Sliding Window
Window
Sash
Foam Seal
(non-adhesive)
Foam Seal
(adhesive)
Window
Sash
Foam Seal
(non-adhesive)
Vertical Sliding Window
Foam Seal
(adhesive)
8. The Portable Air Conditioner is now ready to use.
5EN
INSTALLATION (CONTINUED)
IMPORTANT:
Do not replace or lengthen the hose as this could cause the unit to malfunction.
20" (50 cm)
MIN 31 cm
MAX. 12" (31 cm)
MAX. 43" (110 cm)
Not RecommendedRecommended
WARNING: Any warranties included with this product will be voided if an extra extension hose is
added to the originally provided installation kit or if the installation is performed differently than the
manufacturer's instructions, without proper consultation. Please contact Customer Support for help
with installation procedures if needed.
The supplied hose has a diameter of 5.9" (15 cm) and can be extended from
•
10.6" to 59" (27 cm to 150 cm).
Do not bend (to the extent shown below) the hose. A bent hose will block exhaust air
•
and cause the unit to malfunction or shut-off.
Make sure the back of the unit is at least 20" (50 cm) away from the wall. Do not place the unit in
•
front of curtains or drapes as this could obstruct the airflow.
EN
6
USE AND OPERATION
CONTROL PANEL
(7)(8)(9#)(5)
1) Indicator Lights5) Timer / Temperature Set Controls
2) Power Control6) Mode Control
3) Filter Reset7) Timer Control
4) Fan Speed Control8) Sleep Control
9^) Wi-Fi Connectivity and Voice Activated Control
^THIS IS ONLY FOR MODEL HF08CESVWK / HF10CESVWK
WITH WIFI SMART FEATURES
(1)
(6)(4)(3)(2)
NOTE: For detailed instructions to set up your Portable Air Conditioner
for connected operation from your smart phone or tablet, separate user
manual can be downloaded at:
The Power Control turns the unit on and off. The air vent will automatically open when the unit is
turned ON and automatically close when unit is turned OFF.
FILTER RESET
When the operation has reached 250 hours, the Filter Reset light will illuminate.
Switch the Portable Air Conditioner OFF and carefully remove filters from the unit and clean. Replace
filters and press the Filter Reset button, the Filter Reset light will turn off and the operation time will
be cleared.
EN
7
USE AND OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
FAN SPEED CONTROL
4 settings: High, Medium, Low and Auto.
Note: Auto fan speed can be selected in cooling mode only.
TEMPERATURE CONTROL
The default display is setting temperature.
•
In cooling mode, when or button is pressed, the set temperature is displayed and may be
•
adjusted.
Note: By pressing both or buttons at the same time, the display will toggle between Celsius
(°C) and Fahrenheit (°F).
MODE CONTROL
Settings: Air Conditioning, Dehumidifying, Fan, Auto.
The corresponding indicator light will illuminate to indicate the current mode setting.
Air Conditioning Mode (COOL)
•
Adjust fan speed and air temperature to suit your desired comfort level.
Temperature setting range is 16°C - 32°C (60°F - 90°F).
Ambient temperature range is 16°C - 35°C (60°F - 95°F).
Dehumidifying Mode (DRY)
•
Fan speed is preset to Low.
Note: If the unit will be used mainly as a dehumidifier, do not connect the hose. Continuous
drainage is then necessary (refer to Continuous Draining for Dehumidifier Mode).
IMPORTANT: The Dehumidifier mode is used to support moisture reduction but should not
be expected to dehumidify to the same degree as a standard dehumidifier-only appliance. The
built-in dehumidifier automatically adjusts dehumidification based on ambient room temperatures.
It is not possible to adjust to a desired humidity percentage. The front display only shows the
current and desired temperatures. It does not show humidity levels.
Fan Mode
•
For air circulation without air conditioner cooling.
Note: Auto fan speed cannot be selected in fan mode.
Auto Mode
•
Press the or button to select the temperature you want.
In this mode, the unit will automatically select cooling or fan only depends on the set temperature
and the room temperature. The Portable Air Conditioner will control room temperature
automatically around the set temperature.
Note: Fan speed can't be adjusted in auto mode.
EN
8
USE AND OPERATION (CONTINUED)
FUNCTION BUTTONS (CONTINUED)
TIMER CONTROL
The Timer is adjustable between 1 - 24 hours.
AUTO TURN OFF:
While unit is running, press the Timer button and the display will flash. While the display is
flashing, press the or button to select the number of hours you want the unit to turn OFF
automatically.
AUTO TURN ON:
When unit is in a standby mode (plugged in with power light will on for seconds when plugged then
turn off), press the Timer button and the display will flash. While the display is flashing,
press the or button to select the number of hours until you want the unit to turn ON
automatically.
SLEEP MODE
When the Sleep Mode is activated in Air Conditioning mode, the set temperature will increase by 1°C
or 1°F after the first hour of cooling and will increase a further 1°C or 1°F after the second hour of
cooling. The unit will maintain this temperature for 5 hours. The set temperature will then reduce by
1°C or 1°F on the seventh hour and reduce a further 1°C or 1°F on the tenth hour. Sleep mode will
then deactivate automatically.
Note: The Sleep Mode can be deactivated during cooling mode by pressing any button at any time.
WATER FULL ALARM
Condensation may accumulate in the unit.
If the internal tank is full, error code "P1" will be displayed and an alarm will beep for 3 seconds.
The unit will not operate until the water has been drained from the lower drain plug (refer to Water
Condensation Drainage).
After switching the Portable Air Conditioner off, the compressor will not start immediately. You
must wait about 4 minutes before it switches back on again.
WI-FI MODE^
When the Smart Portable Air Conditioner is connected to the wifi function, the indicator light
will be illuminated.
^THIS IS ONLY FOR MODEL HF08CESVWK / HF10CESVWK WITH WI-FI SMART FEATURES
EN
9
USE AND OPERATION (CONTINUED)
REMOTE CONTROL
All key functions can be accessed from the remote control.
Power Control
ON / OFF
Temperature Control
When the or
the set temperature is displayed
and may be adjusted
key is pressed,
°F
°C
Timer Control
•
In running mode: Auto switch off
In stand-by mode: Auto switch on
Press or
setting for 1 hour intervals.
•
Timer setting is available from 1 - 24
hours by pressing the key or
•
When timer is set, press the or key
to set will cancel the timer setting.
button to adjust the time
.
Press button to change the
operation mode in the order of:
Air Conditioning
Mode Control
Auto
Dehumidifying
Fan
Sleep Control
ON / OFF
Fan Speed Control
• HIGH • MID • LOW • AUTO
Swing Control
Press button to enable air outlet
louver swinging up and down. Press
button again to disable the swing
function. Swing can only be set from
the remote control.
Note:
Battery Installation: Remove the cover on the back of the remote control and insert two AAA
•
batteries with + and - pointing in the proper direction according to the polarity markings.
Caution:
Use only two AAA or IEC R03 1.5V batteries.
•
Remove the batteries if the remote control is not in use for a month or longer.
•
All batteries should be replaced at the same time, do not mix with old batteries.
•
Do not mix alkaline, standard (carbon-zinc) or rechargeable (nickel-cadmium) batteries.
•
Properly dispose of used batteries.
•
This device complies with part 15 of the FCC Rules. Operation is subject to following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment dose cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment info an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/ TV technician for help.
Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
10EN
CLEANING AND MAINTENANCE
Appliance Maintenance:
Turn off the appliance before disconnecting the power supply.
1.
Only clean the appliance with a soft dry cloth.
2.
Dust Filter Maintenance:
The dust filter is to be cleaned every two weeks to maintain air cooling efficiency. Please follow the
below instructions for cleaning the dust filters:
Switch off and unplug the Portable Air Conditioner from the
1.
electrical outlet.
Remove the Upper Filter/ Grill, unscrew the Lower Filter/ Grill
2.
and carefully remove.
Gently wash using water and/ or diluted liquid dishwashing
3.
detergent. Rinse thoroughly and gently shake excess water
from the filters. Make sure the filters are dry before reinstalling.
Note: You may use a vacuum cleaner to remove dust.
Replace the Upper Grill onto the unit, and reinstall the Lower
4.
Rear
Grill
Grill with the screw.
WARNING: DO NOT power or operate the Portable Air Conditioner when cleaning or when the Dust
Filter is removed from the unit, or if there is a loose-fitting Dust Filter. DO NOT attempt to handle or
touch any of the parts or wiring inside the Rear Grill after the Dust Filter has been removed from the
unit. Doing so can cause serious injury or electrical shock.
Upper
Dust Filter
Lower
Dust Filter
EN
11
CLEANING AND MAINTENANCE (CONTINUED)
End of Season Storage and Maintenance:
If the appliance will not be used for a long time, follow these steps:
Be sure to drain the left-over water condensation. Remove the lower drain plug and use a drain
1.
pan to collect the water (make sure to replace the deain plug cap when finished).
To dry excess moisture, run the unit in Fan only mode for 30 minutes before storing.
2.
Turn off and unplug the Portable Air Conditioner from the power supply.
3.
Remove the dust filter and clean with water. Dry the dust filter and then reinstall.
4.
Disconnecting the Window Installation Kit:
5.
Remove the Hose from the unit by rotating anti-clockwise then pulling away.
•
Remove the Foam Seal, Window Bracket, Window Bracket Panel Adapter and Hose Connector.
•
It is recommended to store the Window Kit parts in a bag together with the Remote Control,
•
Drain Tube and placing them together with the Portable Air Conditioner unit.
If needed, you can clean the Window Kit with a damp cloth and water before storing.
•
Make sure all parts of the Window Kit are dry before storage.
Cover the Portable Air Conditioner with a cloth/ plastic bag before storage, to protect from dust
6.
and scratches collecting on the surface of the unit.
It is recommended to coil the power cord before storing to ensure the cord is protected from
7.
bents and creases.
Store the Portable Air Conditioner in a cool, dry place, away from direct sunlight.
8.
EN
12
WATER CONDENSATION DRAINAGE
When there is excess water condensation inside the unit, the Portable Air Conditioner stops running
and shows an error code "P1" with an alarm. This indicates that the water condensation needs to be
drained using the following procedures:
Manual Draining in Cooling, Dehumidifying and Auto Modes
Water may need to be drained in high humidity areas.
Unplug the unit from power source.
1.
Place a drain pan under the lower rubber drain plug.
2.
See diagram.
Remove the drain plug cap.
3.
Water will drain out and collect in the drain pan.
4.
After the water is drained, replace the drain plug cap.
5.
You can now turn on the unit.
6.
Continuous Draining in Dehumidifier Mode
While using the unit in dehumidifier mode, continuous drainage is recommended.
Unplug the unit from power source.
1.
Remove the upper drain plug cap.
2.
Some residual water may spill so please have a pan to
collect the water.
Connect the drain tube (included) to the upper drain
3.
plug. See diagram.
The water can be continuously drained through the
4.
drain tube into a floor drain or bucket.
Replace the drain plug cap.
IMPORTANT: It is NOT recommended to connect the drain hose for continuous drainage while the
unit is switched ON in air conditioning cooling mode. Doing so can reduce the cooling efficiency
of the Portable Air Conditioner. Only drain the water condensation when the unit is switched off.
Continuous drainage is only suitable when the unit is set up in Dehumidifier mode.
13EN
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems persist, call
customer support. Unplug and disconnect the appliance from the power source before attempting
to troubleshoot.
PROBLEMPOSSIBLE CAUSESOLUTION
No electricity.Check for power.
Batteries in the remote
The air
conditioning
unit does not
start
control need to be
replaced.
The power cord is not
properly plugged in.
Change remote control batteries.
Remove and reconnect the power cord.
Runs a short
while only
The safety LCDI plug has
tripped (USA / Canada /
Mexico only).
The thermostat
temperature setting
is too close to room
temperature.
Air outlet is blocked.Make sure the hose is properly connected.
There are tight bends in
the air hose.
Reset the safety LCDI plug, if problem
persists contact our customer support
(USA / Canada / Mexico only).
Lower the set temperature.
Connect hose as per instructions on page 3.
EN
14
TROUBLESHOOTING GUIDE (CONTINUED)
PROBLEMPOSSIBLE CAUSESOLUTION
A door or window is open. Make sure the window or door is closed.
The dust filter is dirty.Clean the dust filter.
Runs but not
cooling
The hose is detached.
Temperature setting is
too high.
Air outlet or intake is
blocked.
Room exceeds
recommended size.
Large size or number of
windows are decreasing
cooling effectiveness.
Reinstall hose properly
(refer to Installation section).
Reduce temperature setting.
Remove blockage.
Move unit to smaller room.
Cover windows with curtains or blinds.
Will not run and
error code "P1"
is displayed
Excess water
condensation inside
the tank.
Drain the water (refer to Water Condensation
Drainage).
15
EN
Loading...
+ 43 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.