The exclamation point within an equilateral triangle is intended to alert the user to the
presence of important operating and maintenance(servicing) instru ctions in the literature
accompanying the appliance.
-1-
CAUTION:
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
TO REDUCE THE RISK OF ELECTRIC
SHOCK, DO NOT REMOVE COVER
(OR BACK). NO USER SERVICEABLE
PARTS INSIDE.
PREFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
Indicate a potentially hazardous situation which if not avoided,
may result in minor or moderate injury. It may also be used to
alert against unsafe practices.
Warning:
This equipment generates and uses radio frequency energy
and if not installed and used properly, I.e., in strict accordance
with the instruction manual, may cause harmful interference
to radio communications. It has been tested and found to comply
with the limits for a Class A computing device pursuant to Subpart
J of Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference when operated in a commercial
environment.
Warning:
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
-2 -
CAUTION FOR SAFE OPERATION
1. Water and Moisture
To prevent fire or shock hazard, do not expose this camera
to rain or moisture.
2. Servicing
Do not attempt to disassemble or repair by yourself.
You may be exposed to dangerous voltage or other hazards.
Note that all servicing is qualified service personnel.
Modifications not approved by manufacturer could
void the user's authority to operate the equipment.
3. Power Sources
To prevent electric shocks and risk of hazards, do NOT use
more than the specified power source.
4. Environment
Do not install too warm or too cold place. Recommended
operation temperature is between -5℃ and 60℃
5. Sunlight
Do not point the camera at the sun. CCD can be damaged.
6. Heavy Shock and Vibration
Do not drop the camera or subject it to heavy shock of
vibration.
7. Install on an Unstable Place
Do not place or install this camera on an unstable place,
stand, tripod, bracket or table. That may cause serious injury
to people or damage to appliance.
8. When operation is incorrect or a ma lfunctio n is obs erved
While operating, if any abnormal condition (strange sound,
smell or smoke) or a malfunction (no pictures, etc.) is
observed, stop using the camera immediately, turn the
power off, then contact your supplier.
9. Cleaning
Turn the power off and wipe off the dirt with a dry soft
cloth. If it is extremely dirty, use furniture cleaner to wipe it
off. To clean the lens, use a blower or lens cleaning
tissue. (available from any camera dealer)
10. Do not shoot any source of bright light.
If the objects contain very bright areas, bright vertical or
horizontal lines may appear on the screen. This is called
"smear" , a Phenomenon which often occurs with solid
- state pickups, and is not a malfunction.
11. Damage Requiring service
Unplug the camera from the power source and refer
servicing to qualified service personnel under the following
condition:
a. If the power-supply cord or plug is damaged.
b. If the camera has been exposed to rain or water.
c. If liquid has been spilled, or objects have fallen into the camera.
d. If the camera does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operating instructions as an improper adjustment of other controls
may result in damage and will often require extensive work by a
qualified technician to restore the camera to its normal operation.
e. If the camera has been dropped or the cabinet has been damaged.
f . If the camera exhibits a distinct change in performance.
Warranty is not covered in case of natural disaster or wrong
Installation.
-3 -
CONTENTS
1. Features
2. Names & Functions
3. Installation
4. Remote Control Connections
5. On Screen Display
6. Specifications
7. Dimensions
Thank you for using this OSD Color Camera with Day and Night, WDR. To
get the best efficiency, read carefully all instructions in this manual before
use, and keep this manual for reference. If you have any problems with
this camera, contact your supplier to service.
-----------------------5
-----------------------6
-----------------------8
----------------------- 10
----------------------- 11
----------------------- 19
----------------------- 20
-4 -
1. Features
Honeywell’s HCC-745NTW/PTW Series is a high sensitivity CCD color camera with high
sensitivity function
of Day & Night function and field integration technique.
-. Sync. Control : AUTO, Internal, L/L (V.PH control)
-. Shutter Speed Control : 8 steps including Flickerless
-. Max AGC Control : OFF ~ 38dB
-5 -
2. Names & Functions
C/CS Mount Adaptor
• C-Mount lens : Turn Counterclockwise
• CS-Mount lens : Turn Clockwise
LENS CONNECTOR
Connect Auto Iris Lens
plug
-6 -
Set Screw
Loosen Locking Ring to adjust mounting
ring
(UP) BUTTON
(-) BUTTON
MENU BUTTON
(DOWN) BUTTON
POWER INPUT
TERMINAL
(+) BUTTON
VIDEO OUTPUT
This is the output terminal
for composite video signal
POWER ON LAMP
In power ON state,
this LED is ON .
CAMERA CONTROL CONNECTOR
( Refer to 4. Camera Control Methods )
Lens Type Select S witch
DC Lens : with no iris amp.
VSD Lens : with iris amp.
-7 -
3. Installation
3.1 The packing box should include, in addition to this User Guide:
-. One HCC-745NTW or HCC-745PTW camera
-. One 6-pin connection cable ( G-113510-200 )
-. One Auto Iris lens plug
3.2 Mounting a Lens
3.2.1 C/CS Mount Lens
① Remove the protective cap in front of the camera.
② Adjust the mount ring whether it is for C or CS.
③ Loosen Se t Screw.
④ Turn the mount ring counterclockwise in case of C-Mount Lens.
Turn the mount ring clockwise in case of CS-Mount Lens
3.2.2 Auto Iris Lens
① Remove the cover of the auto iris lens plug and connect with the lens cable.
② Connect the auto iris lens plug to the 4-pin lens terminal on the side of
the camera.
③ Set the EE MODE to ALC MODE on the OSD menu ( see 5.6 AE MODE)
-. Auto iris lens with no amplifier : Set the DC LENS on the OSD menu
-. Auto iris lens with amplifier : Set the VS D LENS on OSD menu
☞ Adjust by using “LENS ADJ.” on OSD menu to avoid hunting.
VSD LENS PIN CONFIGURATION
3
1
1. POWER(12V) 2. NO CONNECTION
3. VIDEO SIGNAL 4. GND
4
2
Set the select switch to VSD
③
①
④②
-8 -
DC IRIS LENS PIN CONFIGURATION
3
1
1. CONTROL-2. CONTROL+
3. DRIVE+ 4. DRIVE-
4
2
Set the select switch to DC
③
①
④②
④ Set the switch on the rear of the camera to DC or VSD.
☞ Use the connection recommended by the manufacturer.
(E4-191, Chuo Musen, Japan) For best practices, read the lens manual
carefully. You may need to set the flange back focus.
3.3 Flange back focus adjustment
3.3.1 Fixed Lens
a. Loosen the setscrew and set the lens focus ring to infinity ( ∞ ).
b. Turn the back focus adjustment ring until you see a clear image (the distance
from the camera to the object is more than 23m).
c. Tighten the setscrew.
3.3.2 Zoom lens
a. Loosen the setscrew and set the lens to the maximum telephoto position.
b. Turn the back focus adjustment ring to adjust the focus.
c. Auto iris lens: Aim the camera at a comparatively dark object or reduce
the ambient light so that the iris is fully open.
d. Set the lens to its maximum wide angle position, then set the focus.
e. Repeat step b, c and d until the difference between the focusing positions
is as small as possible.
f. Tighten the setscrew when the best focusing point is found.
3.4 Connection of POWER supply
☞ Check the power source from the external power supply before power on.
☞ Power source capacity :
AC 24V, more than 500mA (Recommended Honeywell HAC-2450)
DC 12V, more than 500mA (Recommended Honeywell HDC-1260R)
-9 -
4. Remote Control Connections
4.1 RS-232C connection ( HCC-745NTW/PTW )
Connect to Serial PORT
RS232C
Serial Cable
( 9 Pin D-Sub )
2
RD
3
TD
5
SG
4
Connect internally
6
for communication
7
8
4.2 RS-485 connection ( HCC-745NTW/PTW- VR )
6P Cable
RD ( TxD )
2
TD ( RxD )
3
4
GND
Serial Cable
6P Cable
1. Red : Not Use
2. Blue : RD(TxD)
3. Yellow : TD(RxD)
4. Black : GND
5. Red : Not Use
6. Black : Not Use
Connect to Serial PORT
RS485
RS485 Converter
TRx+
TRx-
Serial Cable
6P Cable
TRx +
3
2
TRx-
RS485 Converter
6P Cable
1. Red : Not Use
2. Blue : TRx-
3. Yellow : TRx+
4. Black : Not Use
5. Red : Not Use
6. Black : Not Use
-10 -
DESCRIPTIONOSD FormatFUNCTION
5. On Screen Display
②, ③②, ③
④⑥
⑤
①
<Fig5-1. OSD Information Display>
5.1 Understanding the On-Screen Display
a. Press MENU briefly to confirm the current operation setup.
The information (see Fig 5-1) will disappear after five seconds
if there is no button action.
b. When it zoom in or out pressing UP or DOWN key,
whole OSD Information will appear and then disappear.
Press (+) , (-) button, only upper part of OSD Information
( for displaying camera mode ) will appear and then disappear.
(It is for checking current whole camera mode and zoom position )
c. Even though the OSD message disappears the Camera ID
or Title will continue to display. If you do not wish to display the ID,
you can change the display position. (see 5.11)
Options are: Bottom Right, Top Left, Top Right, Non display.
* If you do not need to display the Operating OSD (for example,
for an external text overlay board), it can be set to OFF at all times
through a remote control using RS232C or RS485 connection.
②, ③
①
DISPLAY
②
③
④
⑤
WB MODE
⑥
-11 -
Zoom TELEDx2.5 >>TELEZOOM
Zoom WIDEDx1.0 << WIDE
ID : 0None displayCAMERA ID
ID : 1 ~ 255ID : 002
See 5.11 ■■…■■TITLE
Back Light OFFNon displayBack Light
Back Light ONBL
Speed
1/10000
1/20000
NTSC:1/60, PAL :1/501/60 (1/50)Shutter
NTSC:1/120, PAL:1/100FL
1/2501/250
1/5001/500
1/10001/1000
1/20001/2000
1/40001/4000
1/10000
1/20000
1/500001/50000
Auto Trace White BalanceATW
One Push modeAWC
Indoor Preset (3200°K)IN
Fluorescent (4200°K)FRS
User modeUSR
Outdoor preset (5400°K)OUT
Manual modeMWB
<Table5-1. Operating OSD description>
<< SETUP MENU >>
GENERAL SETTING
AE MODE
WB MODE
NIGHTSHOT MODE
BLC/WDR MODE
PZM SETTING
CAMERA ID SETTING
SPECIAL FUNCTION
FACTORY DEFAULT
EXIT MENU
① SYNC. LEVEL
② BURST LEVEL
③ SYNC. MODE
④ V. PHASE
0
98
L/L
000
RETURN
5.2 Display SETUPMENU
a. Press and hold the MENU (center) button for 2 seconds to display the Setup
menu.
b. Press the UP or DOWN buttons to select a menu item.
5.3 Move from SETUPMENU to submenu
a. Press the MENU button to enter the selected submenu.
b. Press the + or – buttons to increase/decrease the value of the selected item.
5.4 Saving your Settings
When you are satisfied with your settings:
a. Press MENU for two seconds. The submenu is replaced by one of two messages:
① “QUIT?” : displays when you have not changed any settings.
Selecting QUIT exits OSD menu without saving any changed values.
② “SAVE?” : displays when values have been changed.
Selecting SAVE exits OSD menu and saves your changes.
b. Press + or – to select SAVE or QUIT and press MENU to exit OSD. Press UP or
DOWN buttons to cancel the SAVE/QUIT and return to the OSD.
5.5 General Setting
① SYNC. Level
: Adjust the proper SYNC. Level from 0~15.
SYNC. LEVEL0 → 1 → … → 15
② BURST Level
: Adjust the proper BURST Level from 0~255.
BURST LEVEL0 → 1 → … → 255
③ SYNC. Mode
: To synchronize the vertical interval sync pulse of your camera with other
equipment to reduce the effect of picture roll on the monitor.
SYNC. MODEAUTO → INTERNAL → L/L
④ Vertical Phase
: Adjust the proper phase in L/L.
V. PHASE 0 → 1 → … → 524
Notice
☞
L/L mode is not available in DC 12V power.
<Fig5-3. General Setting >
-12 -
<< AE MODE >>
① MODE
② CONTROL
③ MAN. SHUTTER
④ MAN. AGC
⑤ LENS ADJ.
⑥ BRIGHTNESS
⑦ MAX GAIN
⑧ MAX FIELDS
ELC
AUTO
1/60
OFF
Done
60
34dB
510FLDS
RETURN
<Fig5-5. Setting Camera Linghting>
5.6 AE mode
① MODE
: ELC – for a manual (fixed) lens.
ALC – for an automatic iris lens.
MODEELC → ALC
② CONTROL
CONTROLAUTO
♦ ELC MODE
-. AUTO : Iris operates elctronic exposure automatically.
-. MANUAL : Adjust the iris by changing the high shutter speed
♦ ALC MODE
-. VSD LENS : Select for video-type lens
-. DC LENS : Select for direct drive-type lens.
③ MANUAL SHUTTER
: Adjust brightness with high shutter speed.
This field is not adjustable when the camera is set to ELC MODE, Auto.
MAN. SHUTTER 1/60 → 1/100 → . . → 1/50000
④ MANUAL AGC
: Adjust AGC gain at ELC MODE, Manual.
MAN. AGC OFF → 10dB → . . . → 34dB
Notice
☞
Accoring to mode, some menu will skip, not to adjust.
or AGC manually.
⑤ LENS ADJUSTMENT
: Adjust level for DC / VSD lens. While it is adjusting, it displays “Adj-ing”,
after it is completed, it displays “Done”.
LENS ADJ. Adj-ing → Done
Notice
☞
For the better adjustment, set LEVEL on VSD lens to middle value.
⑥ BRIGHTNESS
: Adjust level of Auto Iris. The smaller brightness value is, the darker it is,
because iris is closed more. On the contrary the bigger brightness value
is, the brighter it is, because iris is opened more.
BRIGHTNESS 0 ~ 99
⑦ MAX AGC
: Adjust maximum value of AGC gain.
MAX GAIN OFF → 8dB → . . . . → 38dB
⑧ MAX FIELDS
: Compensate for low illumination. Adjust the maximum integration
fields to get a brighter dynamic image. The scene will be slower
than when set to OFF. The larger this field, the greater the noise
of the image. For more dynamic range, adjust the MAX FIELD and
1. MANUAL : Press + or – button to adjust RED GAIN, BLUE
GAIN automatically to fit Black Body.
2. PUSH : Press + or – button to start the AWC operation.
LoCK : Release the key to fit the present shooting scene’s
white balance
③ RED GAIN (USER mode)
RED GAIN 0 → 1 → …. → 254 → 255
④ BLUE GAIN (USER mode)
BLUE GAIN 0 → 1 → …. → 254 → 255
-14 -
<< NIGHTSHOT MODE >>
① MODE
② DETECT TIME
③ D→N LEVEL
④ N→D LEVEL
⑤ NIGHT COLOR
AUTO
3sec.
3
7
B/W
RETURN
<Fig5-7. NIGHTSHOT Control>
5.8 NIGHTSHOT MODE
① MODE
: The Nightshot menu allows you to set how the camera reacts to
changes in low light illumination and to set when the camera switches
between Night and Day modes.
AUTO – The camera removes or inserts IR cut filter by auto detecting
luminance.
ON – IR cut filter is removed (Night mode)
OFF – IR cut filter is inserted (Day mode)
MODE OFF → AUTO → ON → ….
② DETECT TIME
: Sets the time – 1 to 10 seconds – before the camera switches to Day
or Night mode after detecting a low light condition.
DETECT TIME 1 sec. → 2 sec. → …. → 10 sec.
③ DAY to NIGHT threshold
: Determines the low light detection level – 1 to 10 – when the camera
switchs to Night mode. The lower the value, the darker the lighting
conditions befroe the camera switches.
D→N LEVEL 1 → 2 → 3 → …. → 15
④ NIGHT to DAY threshold
: Determines the low light detection level – 1 to 10 – when the camera
switches to Day mode. The higher the value, the brighter the lighting
conditions before the camera switches.
N→D LEVEL 15 → 9 → 8 → …. → 1
Notice
☞
MODE must be set to AUTO. D->N LEVEL must be set at least 2 less than
the N->D LEVEL setting.
⑤ NIGHT COLOR
☞
5.9 BLC/WDR MODE
① MODE
: Prevents the object in the center of the image from darkening
(silhouette effect) when there is excessive light from behind.
MODEOFF → BLC → WDR → ….
WDR [Wide Dynamic Range] is one of Backlight Compensation,
you can watch not only the object in the center but also the objects
around clearly.
② LEVEL
: Adjust the proper level for WDR.
LEVEL 0 → 1 → 2 → …. → 15
Notice
☞
If you set WDR ON, you will not be able to digital zoom in or out.
-15 -
: Set the color mode as B/W (monochrome) or COLOR in Night mode.
NIGHT COLOR B/W → COLOR → ….
Notice
MODE must be set to AUTO or ON.
<< BLC/WDR MODE >>
① MODE
② LEVEL
WDR
8
RETURN
<Fig5-8. BLC/WDR MODE >
<< PRIVACY ZONE >>
① ZONE NUM.
② CONTROL
③ H START
④ H END
⑤ V START
⑥ V END
⑦ PZM MASKING
ZONE 1
ON
200
300
50
100
BLACK
RETURN
PRESS MENU TO MOVE
<Fig5-10. Privacy Zone Masking>
5.10 PRIVACY ZONE
① ZONE
:PZM(Privacy Zone Mask) is to hide the unwanted view to protect
privacy invasion. It works with Zoom/PAN/TILT operation. Select PZM
zone upto 8 zones.
ZONE NUM. ZONE 1 → ZONE 1 → …. → ZONE 8
② CONTROL
: Set ON/OFF for each PZM Zone.
CONTROL OFF → ON → ….
Press and hold the MENU (cernter) button for 2 seconds to display
PZM move menu. Move PZM to appropriate position by using
UP/DOWN/-/+ button. Press and hold the MENU button for 2 seconds
again to return previous menu.
③ Horizontal Start position
H START 200
④ Horizontal End position
H END 300
⑤ Vertical Start position
V START 50
⑥ Vertical End position
V END 100
⑦ MASKING COLOR
: Choose the color to mask the PZM zone. 10 color (Black,Gray,
ⓑ UVWXYZabcdefghijklmn
ⓒ opqrstuvwxyz12345678
ⓓ 9!?#$%&<>*,.:;/+-=~■
④ TITLE : HONEYWELL
RETURN
<Fig 5-11. CAMERA ID SET >
5.11 Camera ID SET
① ID SET
: Camera ID is indicating number assigned each Camera in case of
controlling many Cameras. It is from 0 to 255. But in case of 0, that is
not
displayed on screen. It is always displayed even though whole Operating
OSD is disappeared on the screen. But it is possible to make non display
and to choose display position (BOTTOM RIGHT, TOP RIGHT, TOP
LEFT) by RS-232C communication.
CAMERA ID 0 ~ 255
caution
☞
1. In case of Camera ID FIX model, it cannot be selected..
2. ID is not changed by MENU control through communication.
② DISPLAY MODE
: Choose which is to display Camera ID or Title.
DISPLAY CAM ID → TITLE → ….
③ DISPLAY POSITION
: Choose where is to display Camera ID or Title on Right Bottom, Left Top,
Right Top or not to display.
POSITION R.BOT → L.TOP → R.TOP → NONE
④ Title
: It is the name of Camera. It enters 10 characters including blank..
TITLE: ■■■■■■■■■■
▣ How to Enter the Title ▣
Let’s enter the Title as “R1” , example
-. Select the position of title character by using (+) or (-) key.
The chosen position is blinking.
TITLE: □ ■■■■■■■■■
ⓑ~ ⓕ
F
W
m
ⓑ~ ⓕ
F
W
m
by using UP,DOWN,
by using UP,DOWN,
-. Select the character “R” among
(+),(-) key. The chosen character “R” is blinking.
7
8
9
A
E
B
C
D
N
P
Q
R
V
S
T
U
e
f
g
h
-. Press MENU key, the character “R” is entered in the Title.
TITLE: R ■■■■■■■■■
-. Select the next position of title character by using (+) or (-) key.
The chosen position is blinking.
TITLE: R □ ■■■■■■■■
-. Select the character “7” among
(+),(-) key. The chosen character “7” is blinking.
7
8
9
A
N
P
Q
R
e
f
g
h
-. Press MENU key, the character “7” is entered in the Title.
TITLE: R7 ■■■■■■■■
l
i
j
k
E
B
C
D
V
S
T
U
l
i
j
k
-17 -
<< SPECIAL FUNCTION >>
① MIRROR
② SHARPNESS
③ NEGATIVE
④ FREEZE
⑤ BAUDRATE
⑥ PROTOCOL
⑦ F.OSD DISP
OFF
10
OFF
OFF
9600bps
DEFAULT
ALL
RETURN
<Fig5-12. SPECIAL FUNCTION >
5.12 SPECIAL FUNCTION
① Mirror Mode
: Mode ON is Mirror Mode, OFF is genera l scr een state.
MIRROR OFF → H MIRROR → V MIRROR → FLIP . . . .
② Sharpness
: Use to change the contour of Scene.
SHARPNESS 0 ~ 15
③ Negative Mode
: Use for Positive and Negative mode. ON is Negative mode,
OFF is Positive mode namely general screen state.
NEGATIVE OFF → ON → ….
④ Freeze Mode
: It pause current image. ON is to stop, OFF is to return
to normal state.
FREEZE ON → OFF → ….
☞ caution
1. Freeze image is not saved after Power OFF / ON .
That’s why it doesn’t have memory for saving.
⑤ BAUD RATE
: Use to communicate through RS232C, RS485, RS232TTL .
BAUDRATE 4800bps → 9600bps → …. → 312kbps
☞ caution
1. When Baud Rate of Camera and external system is not
same, it happens Communication fail.
⑥ PROTOCOL
: Use to communicate through RS232C, RS485.
PROTOCOL DEFAULT → VCL → KD6 → P/D → ....
⑦ Function OSD Display
OSD DISP ALL → NONE → TOP → BOTTOM → ....
ALL : Whole Function OSD display
( Focus Mode, Key state, Zoom Ratio, ID )
TOP : Only Upper OSD display ( Focus Mode, key state )
BOTTOM : Only Lower OSD display ( Zoom Ratio, ID )
NONE : Whoe Function OSD display not.
5.13 FACTORY DEFAULT
: All changed data are returned to shipping condition.
For Initialization, select “RESTORE FACTORY SETTING” and
push MENU key.
☞ caution
1. Keep in mind that this mode return all changed data to
shipping condition.
2. Some menu as ID,TITLE, etc are not initialized.
<< RESTORE DEFAULT >>
① RESTORE FACTORY SETTING
RETURN
<Fig5-13. RESTORE DEFAULT>
5.14 EXIT MENU
① SAVE AND EXIT
: Exit OSD MENU with saving all changed data.
② EXIT
: Exit OSD MENU withoout saving all changed data.
<< EXIT MENU >>
① SAVE AND EXIT
② EXIT
RETURN
<Fig5-14. EXIT MENU>
-18 -
6. Specifications
Model NameHCC-745NTWHCC-745PTW
Pick-up Device1/3” Sony Double Scan Color CCD
Total/Effective Pixels410,000 / 380,000470,000/440,000
Scanning System525 lines, 2:1 Interlace
Digital Zoom RatioX1.0 ~ x2.5 can be adjustable
Sync SystemInternal / External (L/L ), Auto detecting selectable
H.Resolution480 TV lines470 TV lines
S/N Ratiomore than 50 dB ( AGC OFF )
Min. illuminance0.2lx @50IRE, AGC 38dB, Night OFF;
0.01lx @50IRE, AGC 38dB, Night OFF, DSS 510fields;
0.01lx @50IRE, AGC 38dB, Night ON;
0.001lx @50IRE, AGC 38dB, Night ON, DSS 510fields;
Brightness0 ~ 99 adjustable
Shutter Speed1/60 ~ 1/10,0001/50 ~ 1/10,000
Field Integrationx2 ~ x510 adjustable
MirrorHorizontal / Vertical / Filp (Horizontal + Vertical)
Day & Night ModeON / OFF / AUTO
Privacy ZoneON ( up to 8 Zones ) / OFF
AGCON ( 8 ~ 38dB ) / OFF
White BalanceATW / AWC / OnePush / Indoor / Outdoor / MWB / User / Fluorescent
BLC / WDRBLC : ON / OFF, WDR : ON / OFF
Remote ControlRS-232C (basic) / RS-485 (option)
Power Supply/Consump.DC12V ± 2V,AC24V ±10% (5.0 W)
Operation/Storage Temp.-10 ~ 60 ℃( Recommended -5 ~ 50 ℃) / -20 ~ 60 ℃
Dimension / Weight68 x 56 x 120 (mm) / less than 410g
-19 -
7. Dimension
-20 -
MEMO
Honeywell Co., Ltd.
Address : 17F, Kukje Center Building 191,
Hankangro -2ga, Yongsan-gu,
Seoul 140-702, Korea
Phone : 82-2-799-6109, 6108, 6107, 6292
Fax : 82-2-749-6119