Honeywell ES800 User Manual

Page 1
Safety of household and similar electrical appliances
Part 2-98: Particular requirements for humidifiers
Report Number. .............................. :
Test Report issued under the responsibility of:
160421073GZU-003
Date of issue ................................... :
Total number of pages ................... :
July 05, 2016; Modification 1: October 12, 2016 116
Applicant’s name ............................ :
Address ........................................... :
Jmatek Limited Suite 808A, Tower A, Manulife Financial Centre, 223-231 Wai Yip
Street, Kwun Tong, Hong Kong.
Test specification:
Standard .......................................... :
IEC 60335-2-98:2002 (Second Edition) + A1:2004 + A2:2008 IEC 60335-1:2010 (Fifth Edition)
Test procedure ............................... :
Non-standard test method ............. :
Test Report Form No. ..................... :
Test Report Form(s) Originator..... :
Master TRF ...................................... :
LVD N/A IEC60335_2_98E VDE Dated 2013-06
Copyright © 2013 Worldwide System for Conformity Testing and Certification of Electrotechnical Equipment and Components (IECEE), Geneva, Switzerland. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the reader's interpretation of the reproduced material due to its placement and context.
If this Test Report Form is used by non-IECEE members, the IECEE/IEC logo and the reference to the CB Scheme procedure shall be removed.
This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in accordance with IECEE 02.
Test item description ..................... :
Trade Mark ...................................... :
Manufacturer ................................... :
Model/Type reference .................... :
Ratings ............................................ :
Humidifier (Evaporative Air Cooler) Honeywell Jmatek Limited ES800, ES071-1AE DC24V, 36W, 1,5A, Class III
Note: this appliance can be powered by adapter mode with rating: Input: AC 100-240V, 50/60Hz, 1,5A or 1,0A, Output: 24V, 1,5A, Class II.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 2
Page 3
Page 3 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
List of Attachments (including a total number of pages in each attachment): N/A N/A
Summary of testing:
The products tested comply with the standards of EN 60335-1:2012+A11:2014 EN 60335-2-98:2003+A1:2005+A2:2008 EN 60335-2-80:2003+A1:2004+A2:2009 EN 62233:2008
Tests performed (name of test and test clause): Original:
Testing location:
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Full tests were conducted on model ES071-1AE. Tests of clause 10, 11, 13, 15, 20, 29, 30 and
construction check were conducted on ES800.
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Modification 1:
After reviewed, no test was needed to be conducted on the appliance.
Summary of compliance with National Differences List of countries addressed: EUROPEAN GROUP DIFFERENCES
The product fulfils the requirements of EN 60335-1:2012+A11:2014; EN 60335-2-
98:2003+A1:2005+A2:2008; EN 60335-2-80:2003+A1:2004+A2:2009; EN 62233:2008.
Copy of marking plate: The artwork below may be only a draft. The use of certification marks on a product must be
authorized by the respective NCBs that own these marks.
Remark: the label of model ES071-1AE is the same as above except the model name. Note1: When placing these electrical equipments on the market, the importer and manufacturer will
indicate on the electrical equipments his name, registered trade name or registered trade mark and the postal address at which he can be contacted.
Note2: When placing these electric equipement on the market, Type, batch, or series number that allows their identifications will be marked.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 4
Page 4 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Test item particulars .................................................. :
Classification of installation and use ...................... :
Supply Connection..................................................... :
...................................................................................... :
Possible test case verdicts:
- test case does not apply to the test object ............ :
- test object does meet the requirement .................. :
- test object does not meet the requirement ............ :
Testing .......................................................................... :
Date of receipt of test item ......................................... :
Date (s) of performance of tests ................................ :
Portable appliance, Class III Safety extra low voltage
N/A P (Pass) F (Fail)
September 29, 2016 September 29, 2016 – October 12, 2016
General remarks:
The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(See Enclosure #)" refers to additional information appended to the report. "(See appended table)" refers to a table appended to the report.
Throughout this report a comma / point is used as the decimal separator.
When determining the test result, measurement uncertainty has been considered. This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between
Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program.
The test report only allows to be revised only within the report defined retention period unless standard or regulation was withdrawn or invalid.
Manufacturer’s Declaration per sub-clause 4.2.5 of IECEE 02:
The application for obtaining a CB Test Certificate includes more than one factory location and a declaration from the Manufacturer stating that the
Yes Not applicable
sample(s) submitted for evaluation is (are) representative of the products from each factory has
been provided ................................................................ :
When differences exist; they shall be identified in the General product information section.
Name and address of factory (ies) ........................... :
Foshan Shunde Toppin Electrical Technology Co., Ltd No.7 Chaogui Road Hi-Tech Area,Ronggui, Shunde
District, Foshan City, Guangdong, China
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 5
Page 5 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
General product information: Original:
The appliances are evaporative air cooler intended for household indoor use. The appliances are supplied by a safety extra-low voltage. The two models have the same electric component, such as DC fan motor, water pump, sync. Motor and etc.
Modification 1:
This test report replaces the original test report 160421073GZU-003, dated on July 05, 2016. It is issued because of adding supplementary information in this report:
1. Add “Note: this appliance can be powered by adapter mode with rating: Input: AC 100-240V,
50/60Hz, 1,5A, Output: 24V, 1,5A or 1,0A, Class II.” in Ratings on page 1.
2. Add below information in table 24.1:
Note: this appliance can be powered by the following adapter mode Adapter Foshan city
Dizhi power supply Co., Ltd.
DSS36­2401500-H
Input: AC 100­240V; 50/60Hz; 1,5A; Output:
IEC/EN 61558­2-16
TUV Rheinland S 50316491
24V; 1,5A; Class II
Alternative Dongguan yuan
shuai electronic Co., Ltd
YeS36W­2400150V
Input :100­240V~; 50/60H z; 1,0A Max; Output : 24V; 1,5A; Class II
Alternative Various Various Input: AC 100-
240V; 50/60Hz; 1,5A; Output: 24V; 1,5A; Class II
IEC/EN 61558­2-16
IEC/EN 61558­2-16
Intertek 16HKS0430-01
S & other EU certification marks
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 6
Page 6 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
5 GENERAL CONDITIONS FOR THE TESTS ---­ Tests performed according to clause 5, e.g. nature
P
of supply, sequence of testing, etc.
5.6 Humidistats are short-circuited or rendered
N/A
inoperative (IEC 60335-2-98)
6 CLASSIFICATION ----
6.1 Protection against electric shock:
Class III P
Class 0, 0I, I, II, III ....................................... ......... :
6.2 Protection against harmful ingress of water IPX0 N/A
7 MARKING AND INSTRUCTIONS ----
7.1 Rated voltage or voltage range (V) ....................... : DC24V P
Symbol for nature of supply, or ............................. :
P
Rated frequency (Hz) ............................................ : N/A
Rated power input (W), or ..................................... : 36 P
Electrode-type appliances marked with rated power
N/A
input (IEC 60335-2-98)
Rated current (A) ................................................. : 1,5 P
Manufacturer's or responsible vendor's name,
Honeywell P
trademark or identification mark ........................... :
Model or type reference ........................................ : See marking plates P
Symbol IEC 60417-5172, for class II appliances N/A
IP number, other than IPX0 .................................. : IPX0 N/A
Symbol IEC 60417-5180, for class III appliances,
P
unless the appliance is operated by batteries only N/A Symbol IEC 60417-5036, for the enclosure of
N/A electrically-operated water valves in external hose-sets for connection of an appliance to the water mains, if the working voltage exceeds extra-low voltage
Appliances manually filled have level mark or other
N/A means to indicate when they filled to their rated capacity, unless they cannot be filled beyond this capacity. Indication visible when appliance being filled. (IEC 60335-2-98)
If temperature of water vapour exceeds 60 °C,
N/A appliance marked with symbol IEC 60417-5597 (2002-10) or (IEC 60335-2-98/A2)
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 7
Page 7 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
with substance of the following:
N/A CAUTION: Hot water vapour (IEC 60335-2-98/A2)
7.2 Warning for stationary appliances for multiple
N/A supply
Warning placed in vicinity of terminal cover N/A
7.3 Range of rated values marked with the lower and
N/A upper limits separated by a hyphen
Different rated values marked with the values
N/A separated by an oblique stroke
7.4 Appliances adjustable for different rated voltages,
N/A the voltage setting is clearly discernible
Requirement met if frequent changes are not
N/A required and the rated voltage to which the appliance is to be adjusted is determined from a wiring diagram
7.5 Appliances with more than one rated voltage or one
N/A or more rated voltage ranges, marked with rated input or rated current for each rated voltage or range, unless
the power input is related to the arithmetic mean
N/A value of the rated voltage range
Relation between marking for upper and lower limits
N/A of rated power input or rated current and voltage is clear
7.6 Correct symbols used P Symbol for nature of supply placed next to rated
N/A voltage
Symbol for class II appliances placed unlikely to be
N/A confused with other marking
Units of physical quantities and their symbols
P according to international standardized system
7.7 Connection diagram fixed to appliances to be
N/A connected to more than two supply conductors and appliances for multiple supply, unless
correct mode of connection is obvious N/A
7.8 Except for type Z attachment, terminals for connection to the supply mains indicated
----
as follows:
- marking of terminals exclusively for the neutral
N/A conductor (letter N)
- marking of protective earthing terminals (symbol
N/A IEC 60417-5019)
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 8
Page 8 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- marking not placed on removable parts N/A
7.9 Marking or placing of switches which may cause a
P hazard
7.10 Indications of switches on stationary appliances and controls on all appliances by use of figures, letters
By symbols and other visual means
P
or other visual means............................................ :
This applies also to switches which are part of a
P
control
If figures are used, the off position indicated by the
N/A
figure 0
The figure 0 indicates only OFF position, unless no
N/A
confusion with the OFF position
7.11 Indication for direction of adjustment of controls P
7.12 Instructions for safe use provided P
Details concerning precautions during user
P
maintenance
The instructions state that: ----
- the appliance is not to be used by persons
P (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction
- children being supervised not to play with the
P appliance
For a part of class III construction supplied from a
N/A detachable power supply unit, the instructions state that the appliance is only to be used with the unit provided
Instructions for class III appliances state that it must
P only be supplied at SELV, unless
it is a battery-operated appliance, the battery being
N/A charged outside the appliance
Instructions include details regarding filling, cleaning
P and descaling (IEC 60335-2-98)
The instructions shall state the substance of the following: (IEC 60335-2-98) ----
- care should be taken when using the appliance due
N/A
to the emission of hot water vapour; (IEC 60335-2-98)
- unplug the appliance during filling and cleaning.
P
(IEC 60335-2-98)
The instructions for electrode-type appliances shall include the substance of the
----
following (IEC 60335-2-98):
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 9
Page 9 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- the composition and quantity of solution to be used
N/A
and advice not to use an excessive amount of salt; (IEC 60335-2-98)
- the appliance is not to be operated from a d.c.
N/A
supply. (IEC 60335-2-98)
If symbol IEC 60417-5597 (2002-10) used, meaning
N/A explained (IEC 60335-2-98/A2)
7.12.1 Sufficient details for installation supplied P For an appliance intended to be permanently
N/A connected to the water mains and not connected by a hose-set, this is stated
The installation instructions for appliances intended
N/A to be connected to the water mains shall state the maximum permissible water pressure in pascals. (IEC 60335-2-98)
7.12.2 Stationary appliances not fitted with means for
N/A disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules
7.12.3 Insulation of the fixed wiring in contact with parts
N/A exceeding 50 K during clause 11; instructions state that the fixed wiring must be protected
7.12.4 Instructions for built-in appliances: ----
- dimensions of space N/A
- dimensions and position of supporting and fixing N/A
- minimum distances between parts and
N/A surrounding structure
- minimum dimensions of ventilating openings and
N/A arrangement
- connection to supply mains and interconnection of
N/A separate components
- allow disconnection of the appliance after
N/A installation, by accessible plug or a switch in the fixed wiring, unless
a switch complying with 24.3 N/A
7.12.5 Replacement cord instructions, type X attachment
N/A with a specially prepared cord
Replacement cord instructions, type Y attachment N/A Replacement cord instructions, type Z attachment N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 10
Page 10 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
7.12.6 Caution in the instructions for appliances
N/A incorporating a non-self-resetting thermal cut-out that is reset by disconnection of the supply mains, if this cut-out is required to comply with the standard
7.12.7 Instructions for fixed appliances stating how the
N/A appliance is to be fixed
7.12.8 Instructions for appliances connected to the water mains: ----
- max. inlet water pressure (Pa) ............................ : N/A
- min. inlet water pressure, if necessary (Pa) ........ : N/A
Instructions concerning new and old hose-sets for
N/A appliances connected to the water mains by detachable hose-sets
7.13 Instructions and other texts in an official language English P
7.14 Marking clearly legible and durable, rubbing test as
P specified
7.15 Markings on a main part P Marking clearly discernible from the outside, if
P necessary after removal of a cover
For portable appliances, cover can be removed or
P opened without a tool
For stationary appliances, name, trademark or
N/A identification mark and model or type reference visible after installation
For fixed appliances, name, trademark or
N/A identification mark and model or type reference visible after installation according to the instructions
Indications for switches and controls placed on or
P near the components. Marking not on parts which can be positioned or repositioned in such a way that the marking is misleading
Symbol IEC 60417-5597 (2002-10) or
N/A (IEC 60335-2-98/A2)
marking relating to hot water vapour near vapour
N/A outlet (IEC 60335-2-98/A2)
7.16 Marking of a possible replaceable thermal link or
N/A fuse link clearly visible with regard to replacing the link
8 PROTECTION AGAINST ACCESS TO LIVE PARTS ----
8.1 Adequate protection against accidental contact with
Supplied at SELV P live parts
8.1.1 Requirement applies for all positions, detachable
N/A parts removed
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 11
Page 11 of 116 Report No.: 160421073GZU-003
61032, with a force not exceeding 1
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Lamps behind a detachable cover not removed, if
N/A conditions met
Insertion or removal of lamps, protection against
N/A contact with live parts of the lamp cap
Use of test probe B of IEC 61032, with a force not
N/A exceeding 1 N: no contact with live parts
Use of test probe B of IEC 61032 through openings,
N/A with a force of 20 N: no contact with live parts
8.1.2 Use of test probe 13 of IEC 61032, with a force not
N/A exceeding 1 N, through openings in class 0 appliances and class II appliances/constructions: no contact with live parts
Test probe 13 also applied through openings in
N/A earthed metal enclosures having a non-conductive coating: no contact with live parts
8.1.3 For appliances other than class II, use of test
N/A probe 41 of IEC N: no contact with live parts of visible glowing heating elements
8.1.4 Accessible part not considered live if: ----
- safety extra-low a.c. voltage: peak value not
N/A exceeding 42,4 V
- safety extra-low d.c. voltage: not exceeding 42,4 V Supplied at SELV: 24VDC P
- or separated from live parts by protective
N/A impedance
If protective impedance: d.c. current not exceeding
N/A 2 mA, and
a.c. peak value not exceeding 0,7 mA N/A
- for peak values over 42,4 V up to and including
N/A 450 V, capacitance not exceeding 0,1 µF
- for peak values over 450 V up to and including
N/A 15 kV, discharge not exceeding 45 µC
- for peak values over 15kV, the energy in the
N/A discharge not exceeding 350 mJ
8.1.5 Live parts protected at least by basic insulation before installation or assembly: ----
- built-in appliances N/A
- fixed appliances N/A
- appliances delivered in separate units N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 12
Page 12 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
8.2 Class II appliances and constructions constructed
N/A so that there is adequate protection against accidental contact with basic insulation and metal parts separated from live parts by basic insulation only
Only possible to touch parts separated from live
N/A parts by double or reinforced insulation
9 STARTING OF MOTOR-OPERATED APPLIANCES ---­ Requirements and tests are specified in part 2
N/A when necessary
10 POWER INPUT AND CURRENT
10.1 Power input at normal operating temperature, rated
(see appended table) P voltage and normal operation not deviating from rated power input by more than shown in table 1 . :
For electrode-type appliances, negative deviation not
N/A limited (IEC 60335-2-98/A1)
Test carried out at upper and lower limits of the
N/A ranges for appliances with one or more rated voltage ranges, unless
the rated power input is related to the arithmetic
N/A mean value
10.2 Current at normal operating temperature, rated
(see appended table) P voltage and normal operation not deviating from
rated current by more than shown in table 2 ......... :
Test carried out at upper and lower limits of the
N/A ranges for appliances with one or more rated voltage ranges, unless
the rated current is related to the arithmetic mean
N/A value of the range
11 HEATING ----
11.1 No excessive temperatures in normal use P
11.2 The appliance is held, placed or fixed in position as
P
described .............................................................. :
11.3 Temperature rises, other than of windings,
P determined by thermocouples
Temperature rises of windings determined by
N/A resistance method, unless
the windings are non-uniform or it is difficult to
N/A make the necessary connections
11.4 Electrode-type appliances are supplied at 1,06 times
N/A rated voltage (IEC 60335-2-98)
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 13
Page 13 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
If temperature rise limits exceeded in appliances
N/A incorporating motors, transformers or electronic circuits, and the power input is lower than rated power input, test repeated with appliance supplied at 1,06 times rated voltage (IEC 60335-2-98)
11.5 Motor-operated appliances operated under normal
24VDC x 1,06=25,44V P operation at most unfavourable voltage between
0,94 and 1,06 times rated voltage (V) ................... :
11.6 Combined appliances are operated as heating
N/A appliances (IEC 60335-2-98)
11.7 Appliances are operated until steady conditions are
P established (IEC 60335-2-98)
11.8 Temperature rises monitored continuously and not
(see appended table) P
exceeding the values in table 3 ............................ :
The temperature rise limits of motors, transformers
N/A and components of electronic circuits, including parts directly influenced by them, exceeded when appliance operated at 1,15 times rated power input (IEC 60335-2-98)
If the temperature rise of a motor winding exceeds
N/A the value of table 3, or
if there is doubt with regard to classification of
N/A insulation,
tests of annex C are carried out N/A Sealing compound does not flow out P Protective devices do not operate, except P components in protective electronic circuits tested
N/A for the number of cycles specified in 24.1.4
13 LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING
----
TEMPERATURE
13.1 Leakage current not excessive and electric strength
N/A adequate
Electrode-type appliances supplied at 1,06 times
N/A rated voltage (IEC 60335-2-98)
Motor-operated appliances and combined
N/A appliances supplied at 1,06 times the rated voltage
(V) ......................................................................... :
Protective impedance and radio interference filters
N/A disconnected before carrying out the tests
13.2 For class 0, class II and class III appliances,
Class III appliance N/A leakage current measured by means of the circuit described in figure 4 of IEC 60990
For other appliances, a low impedance ammeter
N/A may be used
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 14
Page 14 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Leakage current measurements ........................... : (see appended table) N/A
Electrode-type appliances, leakage current measured
N/A between metallic mesh placed in water vapour, 10 mm from outlet, and accessible metal parts including metal foil (IEC 60335-2-98/A1)
Leakage current not exceed 0,25 mA
N/A (IEC 60335-2-98/A1)
13.3 The appliance is disconnected from the supply N/A
Electric strength tests according to table 4 ........... : (see appended table) N/A
No breakdown during the tests N/A 14 TRANSIENT OVERVOLTAGES ---­ Appliances withstand the transient over-voltages to
N/A which they may be subjected
Clearances having a value less than specified in
(see appended table) N/A table 16 subjected to an impulse voltage test, the
test voltage specified in table 6 ............................. :
No flashover during the test, unless N/A of functional insulation if the appliance complies
N/A with clause 19 with the clearance short-circuited
15 MOISTURE RESISTANCE ----
15.1 Enclosure provides the degree of moisture
N/A protection according to classification of the appliance
Compliance checked as specified in 15.1.1, taking
N/A into account 15.1.2, followed by the electric strength test of 16.3
No trace of water on insulation which can result in a
N/A reduction of clearances or creepage distances below values specified in clause 29
15.1.1 Appliances, other than IPX0, subjected to tests as
N/A
specified in IEC 60529 .......................................... :
Water valves containing live parts in external hoses
N/A for connection of an appliance to the water mains tested as specified for IPX7 appliances
15.1.2 Hand-held appliance turned continuously through
N/A the most unfavourable positions during the test
Built-in appliances installed according to the
N/A instructions
Appliances placed or used on the floor or table
N/A placed on a horizontal unperforated support
Appliances normally fixed to a wall and appliances
N/A with pins for insertion into socket-outlets are mounted on a wooden board
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 15
Page 15 of 116 Report No.: 160421073GZU-003
from the vertical for a period
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
For IPX3 appliances, the base of wall mounted
N/A appliances is placed at the same level as the pivot axis of the oscillating tube
For IPX4 appliances, the horizontal centre line of
the appliance is aligned with the pivot axis of the oscillating tube, and
for appliances normally used on the floor or table,
the movement is limited to two times 90° for a period of 5 min, the support being placed at the level of the pivot axis of the oscillating tube
Wall-mounted appliances, take into account the
distance to the floor stated in the instructions
Appliances normally fixed to a ceiling are mounted
underneath a horizontal unperforated support, the pivot axis of the oscillating tube located at the level of the underside of the support, and
for IPX4 appliances, the movement of the tube is
limited to two times 90° of 5 min
Appliances with type X attachment fitted with a
flexible cord as described
Detachable parts subjected to the relevant
treatment with the main part
However, if a part has to be removed for user
maintenance and a tool is needed, this part is not removed
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
15.2 Spillage of liquid does not affect the electrical
N/A insulation
Appliances with type X attachment fitted with a
N/A flexible cord as described
Appliances incorporating an appliance inlet tested
N/A with or without an connector, whichever is most unfavourable
Detachable parts are removed N/A Overfilling test with additional amount of
N/A
water, over a period of 1 min (l) ............................ :
In case of doubt, the spillage test is carried out with
N/A the appliance deviating from the normal position of use by an angle not exceeding 5 ° (IEC 60335-2-98)
Appliances intended to be connected to water mains
N/A operated until maximum water level reached. Inlet valve held open and filling continued for 15 min after first evidence of overflow or (IEC 60335-2-98)
until inflow stops automatically (IEC 60335-2-98) N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 16
Page 16 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
The appliance withstands the electric strength test
N/A of 16.3
No trace of water on insulation that can result in a
N/A reduction of clearances or creepage distances below values specified in clause 29
15.3 Appliances proof against humid conditions N/A Checked by test Cab: Damp heat steady state in
N/A IEC 60068-2-78
Detachable parts removed and subjected, if
N/A necessary, to the humidity test with the main part
Humidity test for 48 h in a humidity cabinet N/A Reassembly of those parts that may have been
N/A removed
The appliance withstands the tests of clause 16 N/A 16 LEAKAGE CURRENT AND ELECTRIC STRENGTH ----
16.1 Leakage current not excessive and electric strength
N/A adequate
Protective impedance disconnected from live parts
N/A before carrying out the tests
Tests carried out at room temperature and not
N/A connected to the supply
16.2 Single-phase appliances: test voltage 1,06 times
N/A
rated voltage (V) ................................................... :
Three-phase appliances: test voltage 1,06 times
N/A
rated voltage divided by 3 (V) ............................. :
Leakage current measurements ........................... : (see appended table) N/A
Limit values doubled if: ----
- all controls have an off position in all poles, or N/A
- the appliance has no control other than a thermal
N/A cut-out, or
- all thermostats, temperature limiters and energy
N/A regulators do not have an off position, or
- the appliance has radio interference filters N/A With the radio interference filters disconnected, the
(see appended table) N/A
leakage current do not exceed limits specified ..... :
16.3 Electric strength tests according to table 7 ........... : (see appended table) N/A
Test voltage applied between the supply cord and
(see appended table) N/A inlet bushing and cord guard and cord anchorage
as specified ........................................................... :
No breakdown during the tests N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 17
Page 17 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
17 OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS
----
No excessive temperatures in transformer or
(see appended table) N/A associated circuits in event of short-circuits likely to
occur in normal use .............................................. :
Appliance supplied with 1,06 or 0,94 times rated
N/A voltage under the most unfavourable short-circuit or
overload likely to occur in normal use (V) ............. :
Basic insulation is not short-circuited N/A Temperature rise of insulation of the conductors of
N/A safety extra-low voltage circuits not exceeding the relevant value specified in table 3 by more than 15 K
Temperature of the winding not exceeding the value
N/A specified in table 8
However, limits do not apply to fail-safe
N/A transformers complying with sub-clause 15.5 of IEC 61558-1
18 ENDURANCE ---­ Requirements and tests are specified in part 2
N/A when necessary
19 ABNORMAL OPERATION ----
19.1 The risk of fire, mechanical damage or electric
P shock under abnormal or careless operation obviated
Electronic circuits so designed and applied that a
(see appended table) N/A
fault will not render the appliance unsafe ............. :
Appliances incorporating heating elements
N/A subjected to the tests of 19.2 and 19.3, and
if the appliance also has a control that limit the
N/A temperature during clause 11 it is subjected to the test of 19.4, and
if applicable, to the test of 19.5 N/A Appliances incorporating PTC heating elements are
N/A also subjected to the test of 19.6
Appliances incorporating motors subjected to the
P tests of 19.7 to 19.10, as applicable
Appliances incorporating electronic circuits
N/A subjected to the tests of 19.11 and 19.12, as applicable
Appliances incorporating contactors or relays
N/A subjected to the test of 19.14, being carried out before the tests of 19.11
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 18
Page 18 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Appliances incorporating voltage selector switches
N/A subjected to the test of 19.15
Unless otherwise specified, the tests are continued
N/A until a non-self-resetting thermal cut-out operates, or
until steady conditions are established P If a heating element or intentionally weak part
N/A becomes open-circuited, the relevant test is repeated on a second sample
19.2 Test of appliances with heating elements with
N/A restricted heat dissipation; test voltage (V), power
input of 0,85 times rated power input (W) ............. :
Container of electrode-type appliances filled with
N/A saturated solution of NaCl at 20 °C ± 5 °C, appliance being supplied at rated voltage (IEC60335-2-98)
19.3 Test of 19.2 repeated; test voltage (V), power input
N/A
of 1,24 times rated power input (W) ..................... :
Test not applicable to electrode-type appliances
N/A (IEC60335-2-98)
19.4 Appliances only filled with sufficient water to cover
N/A heating elements (IEC60335-2-98)
Fans switched off (IEC60335-2-98) N/A
19.5 Test of 19.4 repeated on class 0I and I appliances
N/A with tubular sheathed or embedded heating elements. No short-circuiting, but one end of the element connected to the sheath
The test repeated with reversed polarity and the
N/A other end of the heating element connected to the sheath
The test is not carried out on appliances intended to
N/A be permanently connected to fixed wiring and on appliances where an all-pole disconnection occurs during the test of 19.4
19.6 Appliances with PTC heating elements tested at
N/A rated voltage, establishing steady conditions
The working voltage of the PTC heating element is
N/A increased by 5 % and the appliance is operated until steady conditions are re-established. The voltage is then increased in similar steps until 1,5 times working voltage or until the PTC heating
element ruptures (V) ............................................. :
19.7 Stalling test by locking the rotor if the locked rotor
P torque is smaller than the full load torque, or
locking moving parts of other appliances N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 19
Page 19 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Locked rotor, capacitors open-circuited one at a
N/A time
Test repeated with capacitors short-circuited one at
N/A a time, unless
capacitor is of class P2 of IEC 60252-1 N/A Appliances with timer or programmer supplied with
N/A rated voltage for each of the tests, for a period
equal to the maximum period allowed .................. :
Other appliances supplied with rated voltage for a
N/A
period as specified ................................................ :
Winding temperatures not exceeding values
(see appended table) P
specified in table 8 ................................................ :
19.8 Multi-phase motors operated at rated voltage with
N/A one phase disconnected
19.9 Running overload test on appliances incorporating
N/A motors intended to be remotely or automatically controlled or liable to be operated continuously
Motor-operated and combined appliances for which
N/A
30.2.3 is applicable and that use overload protective devices relying on electronic circuits to protect the motor windings, are also subjected to the test
Winding temperatures not exceeding values as
(see appended table) N/A
specified ................................................................ :
19.10 Series motor operated at 1,3 times rated voltage for
N/A
1 min (V) ............................................................... :
During the test, parts not being ejected from the
N/A appliance
19.11 Electronic circuits, compliance checked by
N/A evaluation of the fault conditions specified in
19.11.2 for all circuits or parts of circuits, unless
they comply with the conditions specified in 19.11.1 P Appliances incorporating an electronic circuit that
N/A relies upon a programmable component to function correctly, subjected to the test of 19.11.4.8, unless
restarting does not result in a hazard N/A Appliances having a device with an off position
N/A obtained by electronic disconnection, or a device placing the appliance in a stand-by mode, subjected to the tests of 19.11.4
If the safety of the appliance under any of the fault
N/A conditions depends on the operation of a miniature fuse-link complying with IEC 60127, the test of
19.12 is carried out
During and after each test the following is checked: ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 20
Page 20 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- the temperature of the windings do not exceed the
N/A
values specified in table 8
- the appliance complies with the conditions
N/A specified in 19.13
- any current flowing through protective impedance
N/A not exceeding the limits specified in 8.1.4
If a conductor of a printed board becomes open-circuited, the appliance is
considered to have withstood the particular test, provided both of the following conditions are met:
- the base material of the printed circuit board
N/A withstands the test of annex E
- any loosened conductor does not reduce
N/A clearance or creepage distances between live parts and accessible metal parts below the values specified in clause 29
19.11.1 Fault conditions a) to g) in 19.11.2 are not applied to circuits or parts of circuits meeting both of the following conditions:
- the electronic circuit is a low-power circuit, that is,
N/A the maximum power at low-power points does not exceed 15 W according to the tests specified
- the protection against electric shock, fire hazard,
N/A mechanical hazard or dangerous malfunction of other parts of the appliance does not rely on the correct functioning of the electronic circuit
----
----
19.11.2 Fault conditions applied one at a time, the appliance operating under conditions
---­specified in clause 11, but supplied at rated voltage, duration of the tests as specified:
a) short circuit of functional insulation if clearances
N/A or creepage distances are less than the values specified in clause 29
b) open circuit at the terminals of any component N/A c) short circuit of capacitors, unless N/A they comply with IEC 60384-14 N/A d) short circuit of any two terminals of an electronic
N/A component, other than integrated circuits
This fault condition is not applied between the two
N/A circuits of an optocoupler
e) failure of triacs in the diode mode N/A f) failure of microprocessors and integrated circuits N/A g) failure of an electronic power switching device N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 21
Page 21 of 116 Report No.: 160421073GZU-003
n
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Each low power circuit is short-circuited by
N/A connecting the low-power point to the pole of the supply source from which the measurements were made
19.11.3 If the appliance incorporates a protective electronic
N/A circuit which operates to ensure compliance with clause 19, the relevant test is repeated with a single fault simulated, as indicated in a) to g) of 19.11.2
19.11.4 Appliances having a device with an off position
N/A obtained by electronic disconnection, or
a device that can be placed in the stand-by mode, N/A subjected to the tests of 19.11.4.1 to 19.11.4.7, the
N/A device being set in the off position or in the stand-by mode
Appliances incorporating a protective electronic
N/A circuit subjected to the tests of 19.11.4.1 to
19.11.4.7, the tests being carried out after the protective electronic circuit has operated, except that
appliances operated for 30 s or 5 min during the
N/A test of 19.7 are not subjected to the tests for electromagnetic phenomena.
Surge protective devices disconnected, unless N/A They incorporate spark gaps N/A
19.11.4.1 The appliance is subjected to electrostatic
N/A discharges in accordance with IEC 61000-4-2, test level 4
19.11.4.2 The appliance is subjected to radiated fields in
N/A accordance with IEC 61000-4-3, test level 3
19.11.4.3 The appliance is subjected to fast transient bursts i
N/A accordance with IEC 61000-4-4, test level 3 or 4 as specified
19.11.4.4 The power supply terminals of the appliance
N/A subjected to voltage surges in accordance with IEC 61000-4-5, test level 3 or 4 as specified
Earthed heating elements in class I appliances
N/A disconnected
19.11.4.5 The appliance is subjected to injected currents in
N/A accordance with IEC 61000-4-6, test level 3
19.11.4.6 Appliances having a rated current not exceeding
N/A 16 A are subjected to the class 3 voltage dips and interruptions in accordance with IEC 61000-4-11
Appliances having a rated current exceeding 16 A
N/A are subjected to the class 3 voltage dips and interruptions in accordance with IEC 61000-4-34
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 22
Page 22 of 116 Report No.: 160421073GZU-003
ot emit flames,
complies with
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
19.11.4.7 The appliance is subjected to mains signals in
N/A accordance with IEC 61000-4-13, test level class 2
19.11.4.8 The appliance is supplied at rated voltage and
N/A operated under normal operation. After 60 s the power supply is reduced to a level such that the appliance ceases to respond or parts controlled by the programmable component cease to operate
The appliance continues to operate normally, or N/A requires a manual operation to restart N/A
19.12 If the safety of the appliance for any of the fault
N/A conditions specified in 19.11.2 depends on the operation of a miniature fuse-link complying with IEC 60127, the test is repeated, measuring the current flowing through the fuse-link; measured
current (A); rated current of the fuse-link (A) ........ :
19.13 During the tests the appliance does n
P molten metal, poisonous or ignitable gas in hazardous amounts
Temperature rises not exceeding the values shown
(see appended table) P
in table 9 ............................................................... :
Compliance with clause 8 not impaired P If the appliance can still be operated it
N/A
20.2
Insulation, other than of class III appliances or class III constructions that do not
---­contain live parts, withstands the electric strength test of 16.3, the test voltage as specified in table 4:
- basic insulation (V) .............................................. : 1000V N/A
- supplementary insulation (V) .............................. : 1750V N/A
- reinforced insulation (V) ...................................... : 3000V N/A
After operation or interruption of a control,
N/A clearances and creepage distances across the functional insulation withstand the electric strength test of 16.3, the test voltage being twice the working voltage
The appliance does not undergo a dangerous
P malfunction, and
no failure of protective electronic circuits, if the
N/A appliance is still operable
Appliances tested with an electronic switch in the off position, or in the stand-by
----
mode:
- do not become operational, or P
- if they become operational, do not result in a
N/A dangerous malfunction during or after the tests of
19.11.4
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 23
Page 23 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
If the appliance contains lids or doors that are controlled by one or more interlocks,
----
one of the interlocks may be released provided that:
- the lid or door does not move automatically to an
N/A open position when the interlock is released, and
- the appliance does not start after the cycle in
N/A which the interlock was released
19.14 Appliances operated under the conditions of
N/A clause 11, any contactor or relay contact operating under the conditions of clause 11 being short-circuited
For a relay or contactor with more than one contact,
N/A all contacts are short-circuited at the same time
A relay or contactor operating only to ensure the
N/A appliance is energized for normal use is not short-circuited
If more than one relay or contactor operates in
N/A clause 11, they are short-circuited in turn
19.15 For appliances with a mains voltage selector switch,
N/A the switch is set to the lowest rated voltage position and the highest value of rated voltage is applied
20 STABILITY AND MECHANICAL HAZARDS ----
20.1 Appliances having adequate stability P Tilting test through an angle of 10°, appliance
P placed on an inclined plane/horizontal support, not connected to the supply mains; appliance does not overturn
Tilting test repeated on appliances with heating
N/A elements, angle of inclination increased to 15°
Possible heating test in overturned position;
N/A temperature rise does not exceed values shown in table 9
20.2 Moving parts adequately arranged or enclosed as to
N/A provide protection against personal injury
Protective enclosures, guards and similar parts are
N/A non-detachable, and
have adequate mechanical strength N/A Enclosures that can be opened by overriding an
N/A interlock are considered to be detachable parts
Self-resetting thermal cut-outs and overcurrent
N/A protective devices not causing a hazard by unexpected closure
Not possible to touch dangerous moving parts with
N/A the test probe described
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 24
Page 24 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
21 MECHANICAL STRENGTH ----
21.1 Appliance has adequate mechanical strength and is constructed as to withstand rough handling
Checked by applying 3 blows to every point of the
enclosure like to be weak, in accordance with test Ehb of IEC 60068-2-75, spring hammer test, with an impact energy of 0,5 J
The appliance shows no damage impairing
compliance with this standard, and
compliance with 8.1, 15.1 and clause 29 not
impaired
If doubt, supplementary or reinforced insulation
subjected to the electric strength test of 16.3
If necessary, repetition of groups of three blows on
a new sample
21.2 Accessible parts of solid insulation having strength to prevent penetration by sharp implements
Test not applicable if the thickness of
supplementary insulation is at least 1 mm and reinforced insulation at least 2 mm
The insulation is tested as specified, and does
withstand the electric strength test of 16.3
P
(see appended table) P
P
P
N/A
N/A
N/A
N/A
N/A
22 CONSTRUCTION ----
22.1 Appliance marked with the first numeral of the IP
IPX0 N/A system, relevant requirements of IEC 60529 are fulfilled
22.2 Stationary appliance: means to ensure all-pole disconnection from the supply being
----
provided:
- a supply cord fitted with a plug, or N/A
- a switch complying with 24.3, or N/A
- a statement in the instruction sheet that a
N/A disconnection incorporated in the fixed wiring is to be provided, or
- an appliance inlet N/A Singe-pole switches and single-pole protective
N/A devices for the disconnection of heating elements in single-phase, permanently connected class 01 and class I appliances, connected to the phase conductor
22.3 Appliance provided with pins: no undue strain on
N/A socket-outlets
Applied torque not exceeding 0,25 Nm N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 25
Page 25 of 116 Report No.: 160421073GZU-003
of an automatic switching device incorporated within
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Pull force of 50 N to each pin after the appliance
N/A has being placed in the heating cabinet; when cooled to room temperature the pins are not displaced by more than 1 mm
Each pin subjected to a torque of 0,4 Nm; the pins
N/A
are not rotating, unless
rotating does not impair compliance with this
N/A
standard
22.4 Appliance for heating liquids and appliance causing
N/A undue vibration not provided with pins for insertion into socket-outlets
22.5 No risk of electric shock when touching the pins of
N/A the plug, for appliances having a capacitor with rated capacitance exceeding 0,1 µF, the appliance being disconnected from the supply at the instant of voltage peak
Voltage not exceeding 34 V (V) ............................ : N/A
22.6 Electrical insulation not affected by condensing
N/A water or leaking liquid
Electrical insulation of class II appliances not
N/A affected if a hose ruptures or seal leaks
In case of doubt, test as described N/A Drain holes be at least 5 mm in diameter or 20 mm²
N/A in area with minimum dimension of at least 3 mm (IEC60335-2-98)
22.7 Adequate safeguards against the risk of excessive
P pressure in appliances containing liquid or gases or having steam-producing devices
22.8 Electrical connections not subject to pulling during
P cleaning of compartments to which access can be gained without the aid of a tool, and that are likely to be cleaned in normal use
22.9 Insulation, internal wiring, windings, commutators
P and slip rings not exposed to oil, grease or similar substances, unless
the substance has adequate insulating properties P
22.10 Not possible to reset voltage-maintained
N/A non-self-resetting thermal cut-outs by the operation
the appliance, if:
- a non-self-resetting thermal cut-out is required by
N/A the standard, and
- a voltage maintained non-self-resetting thermal
N/A cut-out is used to meet it
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 26
Page 26 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Non-self-resetting thermal motor protectors have a
N/A
trip-free action, unless
they are voltage maintained N/A Reset buttons of non-self-resetting controls so
N/A located or protected that accidental resetting is unlikely
22.11 Reliable fixing of non-detachable parts that provide
P the necessary degree of protection against electric shock, moisture or contact with moving parts
Obvious locked position of snap-in devices used for
N/A fixing such parts
No deterioration of the fixing properties of snap-in
N/A devices used in parts that are likely to be removed during installation or servicing
Tests as described P
22.12 Handles, knobs etc. fixed in a reliable manner P Fixing in wrong position of handles, knobs etc.
P indicating position of switches or similar components not possible
Axial force 15 N applied to parts, the shape being
P so that an axial pull is unlikely to be applied
Axial force 30 N applied to parts, the shape being
P so that an axial pull is likely to be applied
22.13 Unlikely that handles, when gripped as in normal
N/A use, make the operator’s hand touch parts having a temperature rise exceeding the value specified for handles which are held for short periods only
22.14 No ragged or sharp edges creating a hazard for the
P user in normal use, or during user maintenance
No exposed pointed ends of self-tapping screws or
P other fasteners, likely to be touched by the user in normal use or during user maintenance
22.15 Storage hooks and the like for flexible cords smooth
N/A and well rounded
22.16 Automatic cord reels cause no undue abrasion or
N/A damage to the sheath of the flexible cord, no breakage of conductors strands and no undue wear of contacts
Cord reel tested with 6000 operations, as specified N/A Electric strength test of 16.3, voltage of 1000 V
N/A applied
22.17 Spacers not removable from the outside by hand or
N/A by means of a screwdriver or a spanner
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 27
Page 27 of 116 Report No.: 160421073GZU-003
Parts connected by protective impedance separated
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
22.18 Current-carrying parts and other metal parts
P
resistant to corrosion
22.19 Driving belts not relied upon to provide the required
N/A level of insulation, unless
constructed to prevent inappropriate replacement N/A
22.20 Direct contact between live parts and thermal
N/A insulation effectively prevented, unless
material used is non-corrosive, non-hygroscopic
N/A and non-combustible
22.21 Wood, cotton, silk, ordinary paper and fibrous or
P hygroscopic material not used as insulation, unless
impregnated N/A This requirement does not apply to magnesium
N/A oxide and mineral ceramic fibres used for the electrical insulation of heating elements
22.22 Appliances not containing asbestos P
22.23 Oils containing polychlorinated biphenyl (PCB) not
P used
22.24 Bare heating elements, except in class III
N/A appliances or class III constructions that do not contain live parts, adequately supported
In case of rupture, the heating conductor is unlikely
N/A to come in contact with accessible metal parts
22.25 Sagging heating conductors, except in class III
N/A appliances or class III constructions that do not contain live parts, cannot come into contact with accessible metal parts
22.26 For class III constructions the insulation between
P parts operating at safety extra-low voltage and other live parts complies with the requirements for double or reinforced insulation
22.27
N/A by double or reinforced insulation
22.28 Metal parts of class II appliances conductively
N/A connected to gas pipes or in contact with water, separated from live parts by double or reinforced insulation
22.29 Class II appliances permanently connected to fixed
N/A wiring so constructed that the required degree of access to live parts is maintained after installation
22.30 Parts serving as supplementary or reinforced
N/A insulation fixed so that they cannot be removed without being seriously damaged, or
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 28
Page 28 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
so constructed that they cannot be replaced in an
N/A incorrect position, and so that if they are omitted, the appliance is rendered inoperable or manifestly incomplete
22.31 Neither clearances nor creepage distances over supplementary and reinforced insulation reduced below values specified in clause 29 as a result of wear
Neither clearances nor creepage distances
between live parts and accessible parts reduced below values for supplementary insulation if wires, screws etc. become loose
22.32 Supplementary and reinforced insulation constructed or protected against pollution so that clearances or creepage distances are not reduced below the values in clause 29
Supplementary insulation of natural or synthetic
rubber resistant to ageing, or arranged and dimensioned so that creepage distances are not reduced below values specified in 29.2
Ceramic material not tightly sintered, similar
materials or beads alone not used as supplementary or reinforced insulation
Insulating material in which heating conductors are
embedded is considered to be basic insulation, not reinforced insulation
N/A
N/A
N/A
N/A
N/A
N/A
Oxygen bomb test at 70 °C for 96 h and 16 h at
N/A
room temperature
22.33 Conductive liquids that are or may become
N/A accessible in normal use and conductive liquids that are in contact with unearthed accessible metal parts are not in direct contact with live parts
Liquids heated by using electrodes and in direct
N/A contact with their live parts (IEC 60335-2-98)
For class II constructions, conductive liquids that
N/A are or may become accessible in normal use and conductive liquids that are in contact with unearthed accessible metal parts, not in direct contact with basic or reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N/A For class II constructions, conductive liquids which
N/A are in contact with live parts, not in direct contact with reinforced insulation, unless
the reinforced insulation consists of at least 3 layers N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 29
Page 29 of 116 Report No.: 160421073GZU-003
n in a double insulation system if likely to be
Such parts being of metal, and their shafts or fixings
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
An air layer not used as basic or supplementary
N/A insulatio bridged by leaking liquid
22.34 Shafts of operating knobs, handles, levers etc. not
N/A live, unless
the shaft is not accessible when the part is removed N/A
22.35 For other than class III constructions, handles,
N/A levers and knobs, held or actuated in normal use, not becoming live in the event of a failure of basic insulation
N/A are likely to become live in the event of a failure of basic insulation, are either adequately covered by insulation material or their accessible parts are separated from their shafts or fixings by supplementary insulation
This requirement does not apply to handles, levers
N/A and knobs on stationary appliances, other than those of electrical components, provided they are reliably connected to an earthing terminal or earthing contact, or separated from live parts by earthed metal
Insulating material covering metal handles, levers
N/A and knobs withstand the electric strength test of
16.3 for supplementary insulation
22.36 For appliances other than class III, handles
N/A continuously held in the hand in normal use so constructed that when gripped as in normal use, the operators hand is not likely to touch metal parts, unless
they are separated from live parts by double or
N/A reinforced insulation
22.37 Capacitors in class II appliances not connected to
N/A accessible metal parts and their casings, if of metal, separated from accessible metal parts by supplementary insulation, unless
the capacitors comply with 22.42 N/A
22.38 Capacitors not connected between the contacts of a
N/A thermal cut-out
22.39 Lamp holders used only for the connection of lamps N/A
22.40 Motor-operated appliances and combined
N/A appliances intended to be moved while in operation, or having accessible moving parts, fitted with a switch to control the motor. The actuating member of the switch being easily visible and accessible
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 30
Page 30 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
If the appliance cannot operate continuously,
N/A automatically or remotely without giving rise to a hazard, appliances for remote operation being fitted with a switch for stopping the operation. The actuating member of the switch being easily visible and accessible
22.41 No components, other than lamps, containing mercury
22.42 Protective impedance consisting of at least two separate components
Values specified in 8.1.4 not exceeded if any one of
the components are short-circuited or open-circuited
Resistors checked by the test of 14.1 a) in
IEC 60065
Capacitors checked by the tests for class Y
capacitors in IEC 60384-14
22.43 Appliances adjustable for different voltages, accidental changing of the setting of the voltage unlikely to occur
22.44 Appliances not having an enclosure that is shaped or decorated like a toy
22.45 When air is used as reinforced insulation, clearances not reduced below the values specified in 29.1.3 due to deformation as a result of an external force applied to the enclosure
22.46 For programmable protective electronic circuits used to ensure compliance with the standard, the software contains measures to control the fault/error conditions in table R.1
P
N/A
N/A
N/A
N/A
N/A
P
N/A
N/A
Software that contains measures to control the
N/A fault/error conditions specified in table R.2 is to be specified in parts 2 for particular constructions or to address specific hazards
These requirements are not applicable to software
N/A used for functional purpose or compliance with clause 11
22.47 Appliances connected to the water mains withstand
N/A the water pressure expected in normal use
No leakage from any part, including any inlet water
N/A hose
22.48 Appliances connected to the water mains
N/A constructed to prevent backsiphonage of non-potable water
22.49 For remote operation, the duration of operation is to
N/A be set before the appliance can be started, unless
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 31
Page 31 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
the appliance switches off automatically or can
N/A
operate continuously without hazard
22.50 Controls incorporated in the appliance take priority
N/A over controls actuated by remote operation
22.51 There is a control on the appliance manually
N/A adjusted to the setting for remote operation before the appliance can be operated in this mode
There is a visual indication showing that the
N/A appliance is adjusted for remote operation
These requirements not necessary on appliances that can operate as follows,
----
without giving rise to a hazard:
- continuously, or N/A
- automatically, or N/A
- remotely N/A
22.52 Socket-outlets on appliances accessible to the user
N/A in accordance with the socket-outlet system used in the country in which the appliance is sold
22.101 Vapour outlet of appliances incorporating means for
N/A heating water be free from obstructions that could give rise to a significant pressure within container (IEC 60335-2-98)
Container vented to atmosphere, aperture being at
N/A least 5 mm in diameter or 20 mm² in area with minimum dimension of at least 3 mm (IEC 60335-2-98)
22.102 Appliances for wall mounting have reliable provision
N/A for fixing to wall, independent of connection to water mains (IEC 60335-2-98)
22.103 Electrode-type appliances so constructed to ensure
N/A that when filling aperture of container is open, both electrodes disconnected to provide all-pole disconnection under overvoltage category III conditions (IEC 60335-2-98)
This requirement not apply to an appliance that
N/A requires withdrawal of an appliance connector in order to gain access to filling aperture (IEC 60335-2-98/A1)
22.104 Appliances intended to be connected to water mains
N/A withstand water pressure expected in normal use (IEC 60335-2-98)
23 INTERNAL WIRING ----
23.1 Wireways smooth and free from sharp edges P Wires protected against contact with burrs, cooling
P fins etc.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 32
Page 32 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Wire holes in metal well-rounded or provided with
N/A
bushings
Wiring effectively prevented from coming into
P contact with moving parts
23.2 Beads etc. on live wires cannot change their
N/A position, and are not resting on sharp edges
Beads inside flexible metal conduits contained
N/A within an insulating sleeve
23.3 Electrical connections and internal conductors
N/A movable relatively to each other not exposed to undue stress
Flexible metallic tubes not causing damage to
N/A insulation of conductors
Open-coil springs not used N/A Adequate insulating lining provided inside a coiled
N/A spring, the turns of which touch one another
No damage after 10 000 flexings for conductors
N/A flexed during normal use, or
100 flexings for conductors flexed during user
N/A maintenance
Electric strength test of 16.3, 1000 V between live
N/A parts and accessible metal parts
Not more than 10 % of the strands of any conductor
N/A broken, and
not more than 30 % for wiring supplying circuits that
N/A consume no more than 15 W
23.4 Bare internal wiring sufficiently rigid and fixed N/A
23.5 The insulation of internal wiring subjected to the
N/A supply mains voltage withstanding the electrical stress likely to occur in normal use
Basic insulation electrically equivalent to the basic
N/A insulation of cords complying with IEC 60227 or IEC 60245, or
no breakdown when a voltage of 2000 V is applied
N/A for 15 min between the conductor and metal foil wrapped around the insulation
23.6 Sleeving used as supplementary insulation on
N/A internal wiring retained in position by clamping at both ends, or
be such that it can only be removed by breaking or
N/A cutting
23.7 The colour combination green/yellow only used for
N/A earthing conductors
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 33
Page 33 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
23.8 Aluminium wires not used for internal wiring
P
23.9 Stranded conductors not consolidated by soldering
N/A where they are subjected to contact pressure, unless
the contact pressure is provided by spring terminals N/A
23.10 The insulation and sheath of internal wiring,
N/A incorporated in external hoses for the connection of an appliance to the water mains, at least equivalent to that of light polyvinyl chloride sheathed flexible cord (60227 IEC 52)
24 COMPONENTS ----
24.1 Components comply with safety requirements in
P relevant IEC standards
List of components ................................................ : (see appended table) P
If components have not been tested and found to
P comply with relevant IEC standard for the number of cycles specified, they are tested in accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9 no
P additional tests specified in the relevant component standard are necessary other than those specified in 24.1.1 to 24.1.9
Components not tested and found to comply with
relevant IEC standard and components not marked or not used in accordance with its marking, tested under the conditions occurring in the appliance
Lampholders and starterholders that have not being
tested and found to comply with the relevant IEC standard, tested as a part of the appliance and additionally according to the gauging and interchangeability requirements of the relevant IEC standard
No additional tests specified for nationally
standardized plugs such as those detailed in IEC/TR 60083 or connectors complying with the standard sheets of IEC 60320-1 and IEC 60309
24.1.1 Capacitors likely to be permanently subjected to the supply voltage and used for radio interference suppression or for voltage dividing, complying with IEC 60384-14
If the capacitors have to be tested, they are tested
according to annex F
24.1.2 Safety isolating transformers complying with IEC 61558-2-6
P
N/A
N/A
N/A
N/A
N/A
If they have to be tested, they are tested according
N/A
to annex G
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 34
Page 34 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
24.1.3 Switches complying with IEC 61058-1, the number
N/A
of cycles of operation being at least 10 000
If they have to be tested, they are tested according
N/A
to annex H
If the switch operates a relay or contactor, the
N/A
complete switching system is subjected to the test
If the switch only operates a motor staring relay
N/A complying with IEC 60730-2-10 with the number of cycles of a least 10 000 as specified, the complete switching system need not be tested
24.1.4 Automatic controls complying with IEC 60730-1 with the relevant part 2. The number
----
of cycles of operation being at least:
- thermostats: ................................................. 10 000
- temperature limiters: ...................................... 1 000
- self-resetting thermal cut-outs: ......................... 300
- voltage maintained non-self-resetting thermal cut-
N/A N/A N/A N/A
outs: .................................................................. 1 000
- other non-self-resetting thermal cut-outs: .......... 30
- timers:............................................................. 3 000
N/A N/A
- energy regulators: ..................................... 10 000 N/A
The number of cycles for controls operating during
N/A clause 11 need not be declared, if the appliance meets the requirements of this standard when they are short-circuited
Thermal motor protectors are tested in combination
N/A with their motor under the conditions specified in annex D
For water valves containing live parts and that are
N/A incorporated in external hoses for connection of an appliance to the water mains, the degree of protection declared for subclause 6.5.2 of IEC 60730-2-8 is IPX7
24.1.5 Appliance couplers complying with IEC 60320-1 N/A However, for appliances classified higher than
N/A IPX0, the appliance couplers complying with IEC 60320-2-3
Interconnection couplers complying with
N/A IEC 60320-2-2
24.1.6 Small lamp holders similar to E10 lampholders
N/A complying with IEC 60238, the requirements for E10 lampholders being applicable
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 35
Page 35 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
24.1.7 For remote operation of the appliance via a
N/A telecommunication network, the relevant standard for the telecommunication interface circuitry in the appliance is IEC 62151
24.1.8 The relevant standard for thermal links is
N/A
IEC 60691
Thermal links not complying with IEC 60691 are
N/A considered to be an intentionally weak part for the purposes of clause 19
24.1.9 Contactors and relays, other than motor starting
N/A relays, tested as part of the appliance
They are also tested in accordance with clause 17
N/A of IEC 60730-1, the number of cycles of operations in 24.1.4 selected according to the contactor or
relay function in the appliance............................... :
24.2 Appliances not fitted with: ----
- switches or automatic controls in flexible cords N/A
- devices causing the protective device in the fixed
N/A wiring to operate in the event of a fault in the appliance
- thermal cut-outs that can be reset by soldering,
N/A unless
the solder has a melding point of at least 230 °C N/A
24.3 Switches intended for all-pole disconnection of
N/A stationary appliances are directly connected to the supply terminals and have a contact separation in all poles, providing full disconnection under overvoltage category III conditions
24.4 Plugs and socket-outlets for extra-low voltage
N/A circuits and heating elements, not interchangeable with plugs and socket-outlets listed in IEC/TR 60083 or IEC 60906-1 or with connectors and appliance inlets complying with the standard sheets of IEC 60320-1
24.5 Capacitors in auxiliary windings of motors marked
N/A with their rated voltage and capacitance, and used accordingly
Voltage across capacitors in series with a motor
N/A winding does not exceed 1,1 times rated voltage, when the appliance is supplied at 1,1 times rated voltage under minimum load
24.6 Working voltage of motors connected to the supply
N/A mains and having basic insulation that is inadequate for the rated voltage of the appliance, not exceeding 42 V
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 36
Page 36 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
In addition, the motors comply with the
N/A
requirements of annex I
24.7 Detachable hose-sets for connection of appliances
N/A to the water mains comply with IEC 61770
They are supplied with the appliance N/A Appliances intended to be permanently connected
N/A to the water mains not connected by a detachable hose-set
24.8 Motor running capacitors in appliances for which
N/A
30.2.3 is applicable and that are permanently connected in series with a motor winding, not causing a hazard in event of a failure
One or more of the following conditions are to be met: ----
- the capacitors are of class P2 according to
N/A IEC 60252-1
- the capacitors are housed within a metallic or
N/A ceramic enclosure
- the distance of separation of the outer surface to
N/A adjacent non-metallic parts exceeds 50 mm
- adjacent non-metallic parts within 50 mm
N/A withstand the needle-flame test of annex E
- adjacent non-metallic parts within 50 mm
N/A classified as at least V-1 according to IEC 60695-11-10
24.101 Thermal cut-outs incorporated in appliances for
N/A compliance with clause 19 not be self-resetting (IEC 60335-2-98)
25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS ----
25.1 Appliance not intended for permanent connection to fixed wiring, means for
----
connection to the supply:
- supply cord fitted with a plug, N/A
- an appliance inlet having at least the same degree
N/A of protection against moisture as required for the appliance, or
- pins for insertion into socket-outlets N/A
25.2 Appliance not provided with more than one means
P of connection to the supply mains
Stationary appliance for multiple supply may be
N/A provided with more than one means of connection, provided electric strength test of 1250 V for 1 min between each means of connection causes no breakdown
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 37
Page 37 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
25.3 Appliance intended to be permanently connected to fixed wiring provided with one of
----
the following means for connection to the supply mains:
- a set of terminals allowing the connection of a
N/A flexible cord
- a fitted supply cord N/A
- a set of supply leads accommodated in a suitable
N/A compartment
- a set of terminals for the connection of cables of
N/A fixed wiring, cross-sectional areas specified in 26.6, and the appliance allows the connection of the supply conductors after the appliance has been fixed to its support
- a set of terminals and cable entries, conduit
N/A entries, knock-outs or glands, allowing connection of appropriate types of cable or conduit, and the appliance allows the connection of the supply conductors after the appliance has been fixed to its support
For a fixed appliance constructed so that parts can
N/A be removed to facilitate easy installation, this requirement is met if it is possible to connect the fixed wiring without difficulty after a part of the appliance has been fixed to its support
25.4 Cable and conduit entries, rated current of
N/A appliance not exceeding 16 A, dimension according
to table 10 (mm) .................................................... :
Introduction of conduit or cable does not reduce
N/A clearances or creepage distances below values specified in clause 29
25.5 Method for assembling the supply cord to the appliance: ----
- type X attachment N/A
- type Y attachment N/A
- type Z attachment, if allowed in relevant part 2 N/A Type X attachment, other than those with a
N/A specially prepared cord, not used for flat twin tinsel cords
For multi-phase appliances supplied with a supply
N/A cord and that are intended to be permanently connected to fixed wiring, the supply cord is assembled to the appliance by type Y attachment
25.6 Plugs fitted with only one flexible cord N/A
25.7 Supply cords, other than for class III appliances, being one of the following types: ----
- rubber sheathed (at least 60245 IEC 53) N/A
- polychloroprene sheathed (at least 60245 IEC 57) N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 38
Page 38 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- cross-linked polyvinyl chloride sheathed (at least
N/A
60245 IEC 88)
- polyvinyl chloride sheathed. Not used if they are likely to touch metal parts having a temperature rise exceeding 75 K during the test of clause 11
- light polyvinyl chloride sheathed cord
N/A (60227 IEC 52), for appliances not exceeding 3 kg
- ordinary polyvinyl chloride sheathed cord
N/A (60227 IEC 53), for other appliances
- heat resistant polyvinyl chloride sheathed. Not used for type X attachment other than specially prepared cords
- heat-resistant light polyvinyl chloride sheathed
N/A cord (60227 IEC 56), for appliances not exceeding 3 kg
- heat-resistant polyvinyl chloride sheathed cord
N/A (60227 IEC 57), for other appliances
Supply cords for class III appliances adequately
N/A
insulated
Test with 500 V for 2 min for supply cords of
N/A
class III appliances that contain live parts
25.8 Nominal cross-sectional area of supply cords not
N/A
less than table 11; rated current (A); cross-sectional
area (mm²) ............................................................ :
----
----
25.9 Supply cords not in contact with sharp points or
N/A
edges
25.10 Supply cord of class I appliances have a
N/A
green/yellow core for earthing
25.11 Conductors of supply cords not consolidated by
N/A
soldering where they are subject to contact pressure, unless
the contact pressure is provided by spring terminals N/A
25.12 Insulation of the supply cord not damaged when
N/A
moulding the cord to part of the enclosure
25.13 Inlet openings so constructed as to prevent damage
P
to the supply cord
If the enclosure at the inlet opening is not of
N/A
insulating material, a non-detachable lining or bushing complying with 29.3 for supplementary insulation provided
If unsheathed supply cord, a similar additional
N/A
bushing or lining is required, unless the appliance is class 0, or N/A a class III appliance not containing live parts P
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 39
Page 39 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
25.14 Supply cords moved while in operation adequately
N/A
protected against excessive flexing Flexing test, as described: ----
- applied force (N) ................................................. : N/A
- number of flexings .............................................. : N/A
The test does not result in: ----
- short-circuit between the conductors, such that the
N/A
current exceeds a value of twice the rated current
- breakage of more than 10 % of the strands of any
N/A
conductor
- separation of the conductor from its terminal N/A
- loosening of any cord guard N/A
- damage to the cord or the cord guard N/A
- broken strands piercing the insulation and
N/A
becoming accessible
25.15 For appliances with supply cord and appliances to
N/A be permanently connected to fixed wiring by a flexible cord, conductors of the supply cord relieved from strain, twisting and abrasion by use of cord anchorage
The cord cannot be pushed into the appliance to
N/A such an extent that the cord or internal parts of the appliance can be damaged
Pull and torque test of supply cord, values shown in
N/A table 12: mass (kg); pull (N); torque (not on
automatic cord reel) (Nm) ..................................... :
Cord not damaged and max. 2 mm displacement of
N/A the cord
25.16 Cord anchorages for type X attachments constructed and located so that: ----
- replacement of the cord is easily possible N/A
- it is clear how the relief from strain and the
N/A prevention of twisting are obtained
- they are suitable for different types of supply cord N/A
- cord cannot touch the clamping screws of cord
N/A anchorage if these screws are accessible, unless
they are separated from accessible metal parts by
N/A supplementary insulation
- the cord is not clamped by a metal screw which
N/A bears directly on the cord
- at least one part of the cord anchorage securely
N/A fixed to the appliance, unless
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 40
Page 40 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
it is part of a specially prepared cord
N/A
- screws which have to be operated when replacing the cord do not fix any other component, unless
the appliance becomes inoperative or incomplete or
the parts cannot be removed without a tool
- if labyrinths can be bypassed the test of 25.15 is nevertheless withstood
- for class 0, 0I and I appliances they are of insulating material or are provided with an insulating lining, unless
failure of the insulation of the cord does not make
accessible metal parts live
- for class II appliances they are of insulating material, or
if of metal, they are insulated from accessible metal
parts by supplementary insulation
After the test of 25.15, under the conditions
specified, the conductors have not moved by more than 1 mm in the terminals
25.17 Adequate cord anchorages for type Y and Z attachment, test with the cord supplied with the appliance
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
25.18 Cord anchorages only accessible with the aid of a
N/A
tool, or
Constructed so that the cord can only be fitted with
N/A
the aid of a tool
25.19 Type X attachment, glands not used as cord
N/A
anchorage in portable appliances
Tying the cord into a knot or tying the cord with
N/A
string not used
25.20 The insulated conductors of the supply cord for
N/A type Y and Z attachment additionally insulated from accessible metal parts
25.21 Space for supply cord for type X attachment or for connection of fixed wiring constructed:
- to permit checking of conductors with respect to
N/A correct positioning and connection before fitting any cover
- so there is no risk of damage to the conductors or
N/A their insulation when fitting the cover
- for portable appliances, so that the uninsulated
N/A end of a conductor, if it becomes free from the terminal, prevented from contact with accessible metal parts
----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 41
Page 41 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
2 N test to the conductor for portable appliances; no
N/A
contact with accessible metal parts
25.22 Appliance inlets: ----
- live parts not accessible during insertion or
P removal
Requirement not applicable to appliance inlets
N/A complying with IEC 60320-1
- connector can be inserted without difficulty P
- the appliance is not supported by the connector P
- not for cold conditions if temp. rise of external
N/A metal parts exceeds 75 K during clause 11, unless
the supply cord is unlikely to touch such metal parts N/A
25.23 Interconnection cords comply with the requirements
N/A for the supply cord, except that:
- the cross-sectional area of the conductors is
N/A determined on the basis of the maximum current during clause 11
- the thickness of the insulation may be reduced N/A If necessary, electric strength test of 16.3 N/A
25.24 Interconnection cords not detachable without the
N/A aid of a tool if compliance with this standard is impaired when they are disconnected
25.25 Dimensions of pins that are inserted into
N/A socket-outlets compatible with the dimensions of the relevant socket-outlet.
Dimensions of pins and engagement face in
N/A accordance with the dimensions of the relevant plug in IEC/TR 60083
26 TERMINALS FOR EXTERNAL CONDUCTORS ----
26.1 Appliances provided with terminals or equally
N/A effective devices for connection of external conductors
Terminals only accessible after removal of a
N/A non-detachable cover, except
for class III appliances that do not contain live parts N/A Earthing terminals may be accessible if a tool is
N/A required to make the connections and means are provided to clamp the wire independently from its connection
26.2 Appliances with type X attachment and appliances
N/A for the connection of cables to fixed wiring provided with terminals in which connections are made by means of screws, nuts or similar devices, unless
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 42
Page 42 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
the connections are soldered
N/A
Screws and nuts not used to fix any other
N/A component, except
internal conductors, if so arranged that they are
N/A unlikely to be displaced when fitting the supply conductors
If soldered connections used, the conductor so
N/A positioned or fixed that reliance is not placed on soldering alone, unless
barriers provided so that neither clearances nor
N/A creepage distances between live parts and other metal parts reduced below the values for supplementary insulation if the conductor becomes free at the soldered joint
26.3 Terminals for type X attachment and for connection
N/A of cables of fixed wiring so constructed that the conductor is clamped between metal surfaces with sufficient contact pressure but without damaging the conductor
Terminals fixed so that when the clamping means is tightened or loosened: ----
- the terminal does not become loose N/A
- internal wiring is not subjected to stress N/A
- neither clearances nor creepage distances are
N/A reduced below the values in clause 29
Compliance checked by inspection and by the test
N/A of subclause 9.6 of IEC 60999-1, the torque applied being equal to two-thirds of the torque specified
(Nm) ...................................................................... :
No deep or sharp indentations of the conductors N/A
26.4 Terminals for type X attachment, except those
N/A having a specially prepared cord and those for the connection of cables of fixed wiring, no special preparation of conductors such as by soldering, use of cable lugs, eyelets or similar, and
so constructed or placed that conductors prevented
N/A from slipping out when clamping screws or nuts are tightened
26.5 Terminals for type X attachment so located or
N/A shielded that if a wire of a stranded conductor escapes, no risk of accidental connection to other parts that result in a hazard
Stranded conductor test, 8 mm insulation removed N/A No contact between live parts and accessible metal
N/A parts and,
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 43
Page 43 of 116 Report No.: 160421073GZU-003
appliances not containing live parts, accessible after
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
for class II constructions, between live parts and
N/A metal parts separated from accessible metal parts by supplementary insulation only
26.6 Terminals for type X attachment and for connection
N/A of cables of fixed wiring suitable for connection of conductors with cross-sectional area according to table 13; rated current (A); nominal cross-sectional
area (mm²) ............................................................ :
If a specially prepared cord is used, terminals need
N/A only be suitable for that cord
26.7 Terminals for type X attachment, except in class III
N/A removal of a cover or part of the enclosure
26.8 Terminals for the connection of fixed wiring,
N/A including the earthing terminal, located close to each other
26.9 Terminals of the pillar type constructed and located
N/A as specified
26.10 Terminals with screw clamping and screwless
N/A terminals not used for flat twin tinsel cords, unless
conductors ends fitted with means suitable for
N/A screw terminals
Pull test of 5 N to the connection N/A
26.11 For type Y and Z attachment, soldered, welded,
N/A crimped or similar connections may be used
For class II appliances, the conductor so positioned
N/A or fixed that reliance is not placed on soldering, welding or crimping alone
If soldering, welding or crimping alone used,
N/A barriers provided so that clearances and creepage distances between live parts and other metal parts are not reduced below the values for supplementary insulation if the conductor becomes free
27 PROVISION FOR EARTHING ----
27.1 Accessible metal parts of class 0I and I appliances
N/A permanently and reliably connected to an earthing terminal or earthing contact of the appliance inlet
Earthing terminals and earthing contacts not
N/A connected to the neutral terminal
Class 0, II and III appliances have no provision for
P earthing
Safety extra-low voltage circuits not earthed, unless P protective extra-low voltage circuits N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 44
Page 44 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
27.2 Clamping means of earthing terminals adequately
N/A
secured against accidental loosening
Terminals for the connection of external
equipotential bonding conductors allow connection of conductors of 2,5 to 6 mm², and
do not provide earthing continuity between different
parts of the appliance, and
conductors cannot be loosened without the aid of a
tool
27.3 For a detachable part having an earth connection and being plugged into another part of the appliance, the earth connection is made before and separated after current-carrying connections when removing the part
For appliances with supply cords, current-carrying
conductors become taut before earthing conductor, if the cord slips out of the cord anchorage
27.4 No risk of corrosion resulting from contact between parts of the earthing terminal and the copper of the earthing conductor or other metal
Parts providing earthing continuity, other than parts
of a metal frame or enclosure, have adequate resistance to corrosion
If of steel, these parts provided with an
electroplated coating with a thickness at least 5 µm
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Adequate protection against rusting of parts of
N/A coated or uncoated steel, only intended to provide or transmit contact pressure
In the body of the earthing terminal is a part of a
N/A frame or enclosure of aluminium or aluminium alloys, precautions taken to avoid risk of corrosion
27.5 Low resistance of connection between earthing
N/A terminal and earthed metal parts
This requirement does not apply to connections
N/A providing earthing continuity in the protective extra-low voltage circuit, provided the clearances of basic insulation are based on the rated voltage of the appliance
Resistance not exceeding 0,1 at the specified
N/A
low-resistance test ( ) ........................................ :
27.6 The printed conductors of printed circuit boards not
N/A used to provide earthing continuity in hand-held appliances.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 45
Page 45 of 116 Report No.: 160421073GZU-003
mm
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
They may be used to provide earthing continuity in
N/A other appliances if at least two tracks are used with independent soldering points and the appliance complies with 27.5 for each circuit
28 SCREWS AND CONNECTIONS ----
28.1 Fixings, electrical connections and connections providing earthing continuity withstand mechanical stresses
Screws not of soft metal liable to creep, such as
zinc or aluminium
Diameter of screws of insulating material min. 3 Screws of insulating material not used for any
electrical connections or connections providing earthing continuity
Screws used for electrical connections or
connections providing earthing continuity screwed into metal
Screws not of insulating material if their
replacement by a metal screw can impair supplementary or reinforced insulation
For type X attachment, screws to be removed for
replacement of supply cord or for user maintenance, not of insulating material if their replacement by a metal screw impairs basic insulation
For screws and nuts; torque-test as specified in
table 14 ................................................................. :
P
P
N/A N/A
N/A
N/A
N/A
(see appended table) N/A
28.2 Electrical connections and connections providing
N/A earthing continuity constructed so that contact pressure is not transmitted through non-ceramic insulating material liable to shrink or distort, unless
there is resiliency in the metallic parts to
N/A compensate for shrinkage or distortion of the insulating material
This requirement does not apply to electrical connections in circuits of appliances
----
for which:
- 30.2.2 is applicable and that carry a current not
N/A
exceeding 0,5 A
- 30.2.3 is applicable and that carry a current not
N/A
exceeding 0,2 A
28.3 Space-threaded (sheet metal) screws only used for
N/A electrical connections if they clamp the parts together
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 46
Page 46 of 116 Report No.: 160421073GZU-003
Clearances, creepage distances and solid insulation
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Thread-cutting (self-tapping) screws and thread
N/A rolling screws only used for electrical connections if they generate a full form standard machine screw thread
Thread-cutting (self-tapping) screws not used if they
N/A
are likely to be operated by the user or installer
Thread-cutting, thread rolling and space threaded screws may be used in
---­connections providing earthing continuity provided it is not necessary to disturb the connection:
- in normal use, N/A
- during user maintenance, N/A
- when replacing a supply cord having a type X
N/A
attachment, or
- during installation N/A At least two screws being used for each connection
N/A
providing earthing continuity, unless
the screw forms a thread having a length of at least
N/A
half the diameter of the screw
28.4 Screws and nuts that make mechanical connection
N/A secured against loosening if they also make electrical connections or connections providing earthing continuity
This requirement does not apply to screws in the
N/A earthing circuit if at least two screws are used, or
if an alternative earthing circuit is provided N/A Rivets for electrical connections or connections
N/A providing earthing continuity secured against loosening if the connections are subjected to torsion
29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION ----
P withstand electrical stress
For coatings used on printed circuits boards to
N/A protect the microenvironment (Type 1) or to provide
basic insulation (Type 2), annex J applies ............ :
The microenvironment is pollution degree 1 under
N/A type 1 protection
For type 2 protection, the spacing between the
N/A conductors before the protection is applied is not less than the values specified in Table 1 of IEC 60664-3
These values apply to functional, basic,
N/A
supplementary and reinforced insulation .............. :
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 47
Page 47 of 116 Report No.: 160421073GZU-003
those specified for basic insulation in table 16, using
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
29.1 Clearances not less than the values specified in
(see appended table)
P table 16, taking into account the rated impulse voltage for the overvoltage categories of table 15,
unless .................................................................... :
for basic insulation and functional insulation they
N/A
comply with the impulse voltage test of clause 14
However, if the distances are affected by wear,
P distortion, movement of the parts or during assembly, the clearances for rated impulse voltages of 1500 V and above are increased by 0,5 mm and the impulse voltage test is not applicable
Impulse voltage test is not applicable: ----
- when the microenvironment is pollution degree 3,
N/A or
- for basic insulation of class 0 and class 01
N/A appliances
Appliances are in overvoltage category II P A force of 2 N is applied to bare conductors, other
P than heating elements
A force of 30 N is applied to accessible surfaces P
29.1.1 Clearances of basic insulation withstand the
N/A overvoltages, taking into account the rated impulse voltage
The values of table 16 or the impulse voltage test of
(see appended table) N/A
clause 14 are applicable ....................................... :
Clearance at the terminals of tubular sheathed
N/A heating elements may be reduced to 1,0 mm if the microenvironment is pollution degree 1
Lacquered conductors of windings considered to be
N/A bare conductors
29.1.2 Clearances of supplementary insulation not less
(see appended table) N/A than those specified for basic insulation in table 16
.............................................................................. :
29.1.3 Clearances of reinforced insulation not less than
(see appended table) N/A
the next higher step for rated impulse voltage ...... :
For double insulation, with no intermediate
N/A conductive part between basic and supplementary insulation, clearances are measured between live parts and the accessible surface, and the insulation system is treated as reinforced insulation
29.1.4 Clearances for functional insulation are the largest values determined from: ----
- table 16 based on the rated impulse voltage ...... : (see appended table) P
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 48
Page 48 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- table F.7a in IEC 60664-1, frequency not
N/A
exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding
N/A 30 kHz
If values of table 16 are largest, the impulse voltage
N/A test of clause 14 may be applied instead, unless
the microenvironment is pollution degree 3, or N/A the distances can be affected by wear, distortion,
N/A movement of the parts or during assembly
However, clearances are not specified if the
P appliance complies with clause 19 with the functional insulation short-circuited
Lacquered conductors of windings considered to be
P bare conductors
However, clearances at crossover points are not
P measured
Clearance between surfaces of PTC heating
N/A elements may be reduced to 1mm
29.1.5 Appliances having higher working voltages than rated voltage, clearances for basic
----
insulation are the largest values determined from:
- table 16 based on the rated impulse voltage ...... : N/A
- table F.7a in IEC 60664-1, frequency not
N/A exceeding 30 kHz
- clause 4 of IEC 60664-4, frequency exceeding
N/A 30 kHz
If clearances for basic insulation are selected from
N/A Table F.7a of IEC 60664-1 or clause 4 of IEC 60664-4, the clearances of supplementary insulation are not less than those specified for basic insulation
If clearances for basic insulation are selected from
N/A Table F.7a of IEC 60664-1, the clearances of reinforced insulation dimensioned as specified in Table F.7a are to withstand 160% of the withstand voltage required for basic insulation
If clearances for basic insulation are selected from
N/A clause 4 of IEC 60664-4, the clearances of reinforced insulation are twice the value required for basic insulation
If the secondary winding of a step-down transformer
N/A is earthed, or if there is an earthed screen between the primary and secondary windings, clearances of basic insulation on the secondary side not less than those specified in table 16, but using the next lower step for rated impulse voltage
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 49
Page 49 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Circuits supplied with a voltage lower than rated
N/A voltage, clearances of functional insulation are based on the working voltage used as the rated voltage in table 15
29.2 Creepage distances not less than those appropriate
(see appended table) N/A for the working voltage, taking into account the
material group and the pollution degree ............... :
Pollution degree 2 applies, unless N/A
- precautions taken to protect the insulation;
N/A pollution degree 1
- insulation subjected to conductive pollution;
N/A pollution degree 3
Electrode-type appliances, the microenvironment of
N/A the insulation supporting the electrodes is pollution degree 3 (IEC 60335-2-98)
A force of 2 N is applied to bare conductors, other
N/A than heating elements
A force of 30 N is applied to accessible surfaces N/A In a double insulation system, the working voltage
N/A for both the basic and supplementary insulation is taken as the working voltage across the complete double insulation system
29.2.1 Creepage distances of basic insulation not less
(see appended table) N/A
than specified in table 17 ...................................... :
However, if the working voltage is periodic and has
N/A a frequency exceeding 30 kHz, the creepage distances are also determined from table 2 of IEC 60664-4, these values being used if exceeding
the values in table 17 ............................................ :
Except for pollution degree 1, corresponding
N/A creepage distance not less than the minimum specified for the clearance in table 16, if the clearance has been checked according to the test
of clause 14 ........................................................... :
29.2.2 Creepage distances of supplementary insulation at
(see appended table) N/A least those specified for basic insulation in table 17,
or ........................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N/A
29.2.3 Creepage distances of reinforced insulation at least
(see appended table) N/A double those specified for basic insulation in table
17, or ..................................................................... :
Table 2 of IEC 60664-4, as applicable .................. : N/A
29.2.4 Creepage distances of functional insulation not less
(see appended table) N/A
than specified in table 18 ...................................... :
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 50
Page 50 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
However, if the working voltage is periodic and has
N/A a frequency exceeding 30 kHz, the creepage distances are also determined from table 2 of IEC 60664-4, these values being used if exceeding
the values in table 18 ............................................ :
Creepage distances may be reduced if the
N/A appliance complies with clause 19 with the functional insulation short-circuited
29.3 Supplementary and reinforced insulation have
N/A adequate thickness, or a sufficient number of layers, to withstand the electrical stresses
Compliance checked: ----
- by measurement, in accordance with 29.3.1, or N/A
- by an electric strength test in accordance with
N/A
29.3.2, or
- by an assessment of the thermal quality of the
N/A material combined with an electric strength test, in accordance with 29.3.3, and
for accessible parts of reinforced insulation
N/A consisting of a single layer, by measurement in accordance with 29.3.4, or
- as specified in subclause 6.3 of IEC 60664-4 for
N/A insulation that is subjected to any periodic voltage having a frequency exceeding 30 kHz
29.3.1 Supplementary insulation have a thickness of at
N/A least 1 mm
Reinforced insulation have a thickness of at least
N/A 2 mm
29.3.2 Each layer of material withstand the electric
N/A strength test of 16.3 for supplementary insulation
Supplementary insulation consist of at least 2 layers N/A Reinforced insulation consist of at least 3 layers N/A
29.3.3 The insulation is subjected to the dry heat test Bb of
N/A IEC 60068-2-2, followed by
the electric strength test of 16.3 N/A If the temperature rise during the tests of clause 19
N/A does not exceed the value specified in table 3, the test of IEC 60068-2-2 is not carried out
29.3.4 Thickness of accessible parts of reinforced
N/A insulation consisting of a single layer not less than
specified in table 19 .............................................. :
30 RESISTANCE TO HEAT AND FIRE ----
30.1 External parts of non-metallic material, P
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 51
Page 51 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
parts supporting live parts, and
N/A
parts of thermoplastic material providing
N/A supplementary or reinforced insulation
sufficiently resistant to heat N/A Ball-pressure test according to IEC 60695-10-2 P External parts tested at 40 °C plus the maximum
(see appended table) P temperature rise determined during the test of clause 11, or at 75 °C, whichever is the higher;
temperature (°C) ................................................... :
Parts supporting live parts tested at 40 °C plus the
(see appended table) P maximum temperature rise determined during the test of clause 11, or at 125 °C, whichever is the
higher; temperature (°C) ....................................... :
Parts of thermoplastic material providing
(see appended table) N/A supplementary or reinforced insulation tested at 25 °C plus the maximum temperature rise determined during clause 19, if higher; temperature
(°C) ........................................................................ :
30.2 Parts of non-metallic material resistant to ignition
P and spread of fire
This requirement does not apply to: ---­ parts having a mass not exceeding 0,5 g, provided
N/A the cumulative effect is unlikely to propagate flames that originate inside the appliance by propagating flames from one part to another, or
decorative trims, knobs and other parts unlikely to
N/A be ignited or to propagate flames that originate inside the appliance
Compliance checked by the test of 30.2.1, and in
----
addition:
- for attended appliances, 30.2.2 applies N/A
- for unattended appliances, 30.2.3 applies P For appliances for remote operation, 30.2.3 applies N/A For base material of printed circuit boards, 30.2.4
P applies
30.2.1 Parts of non-metallic material subjected to the
P glow-wire test of IEC 60695-2-11 at 550 °C
However, test not carried out if the material is
N/A classified as having a glow-wire flammability index according to IEC 60695-2-12 of at least 550 °C, or
the material is classified at least HB40 according to
N/A IEC 60695-11-10
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 52
Page 52 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Parts for which the glow-wire test cannot be carried
N/A out need to meet the requirements in ISO 9772 for material classified HBF
30.2.3 Appliances operated while unattended, tested as specified in 30.2.3.1 and 30.2.3.2
The tests are not applicable to conditions as
specified ................................................................ :
30.2.3.1 Parts of non-metallic material supporting connections carrying a current exceeding 0,2 A during normal operation, and
parts of non-metallic material, other than small
parts, within a distance of 3 mm,
subjected to the glow-wire test of IEC 60695-2-11
with a test severity of 850 °C
Glow-wire applied to an interposed shielding
material, if relevant
The glow-wire test is not carried out on parts of
material classified as having a glow-wire flammability index according to IEC 60695-2-12 of at least 850 °C
30.2.3.2 Parts of non-metallic material supporting connections, and
parts of non-metallic material within a distance of
3 mm,
P
N/A
P
P
P
N/A
N/A
P
P
subjected to glow-wire test of IEC 60695-2-11 P The test severity is: ----
- 750 °C, for connections carrying a current
P
exceeding 0,2 A during normal operation
- 650 °C, for other connections N/A
Glow-wire applied to an interposed shielding
N/A
material, if relevant
However, the glow-wire test of 750 °C or 650 °C as appropriate, is not carried out on
----
parts of material fulfilling both or either of the following classifications:
- a glow-wire ignition temperature according to
N/A
IEC 60695-2-13 of at least:
- 775 °C, for connections carrying a current
N/A
exceeding 0,2 A during normal operation
- 675 °C, for other connections N/A
- a glow-wire flammability index according to
N/A
IEC 60695-2-12 of at least:
- 750 °C, for connections carrying a current
N/A
exceeding 0,2 A during normal operation
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 53
Page 53 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- 650 °C, for other connections
N/A
The glow-wire test is also not carried out on small parts. These parts are to: ----
- comprise material having a glow-wire ignition
N/A temperature of at least 775 °C or 675 °C as appropriate, or
- comprise material having a glow-wire flammability
N/A index of at least 750 °C or 650 °C as appropriate, or
- comply with the needle-flame test of annex E, or N/A
- comprise material classified as V-0 or V-1
N/A according to IEC 60695-11-10
The consequential needle-flame test of annex E applied to non-metallic parts that
---­encroach within the vertical cylinder placed above the centre of the connection zone and on top of the non-metallic parts supporting current-carrying connections, and parts of non-metallic material within a distance of 3 mm of such connections if these parts are those:
- parts that withstood the glow-wire test of
P IEC 60695-2-11 of 750 °C or 650 °C as appropriate, but produce a flame that persist longer than 2 s, or
- parts that comprised material having a glow-wire
N/A flammability index of at least 750 °C or 650 °C as appropriate, or
- small parts, that comprised material having a
N/A glow-wire flammability index of at least 750 °C or 650 °C as appropriate, or
- small parts for which the needle-flame test of
N/A annex E was applied, or
- small parts for which a material classification of
N/A V-0 or V-1 was applied
However, the consequential needle-flame test is not carried out on non-metallic
----
parts, including small parts, within the cylinder that are:
- parts having a glow-wire ignition temperature of at
N/A least 775 °C or 675 °C as appropriate, or
- parts comprising material classified as V-0 or V-1
N/A according to IEC 60695-11-10, or
- parts shielded by a flame barrier that meets the
N/A needle-flame test of annex E or that comprises material classified as V-0 or V-1 according to IEC 60695-11-10
30.2.4 Base material of printed circuit boards subjected to
P the needle-flame test of annex E
Test not applicable to conditions as specified ...... : N/A
31 RESISTANCE TO RUSTING ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 54
Page 54 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Relevant ferrous parts adequately protected against
P
rusting
Tests specified in part 2 when necessary N/A 32 RADIATION, TOXICITY AND SIMILAR HAZARDS ---­ Appliance does not emit harmful radiation or
P present a toxic or similar hazard due to their operation in normal use
Compliance is checked by the limits or tests
P specified in part 2, if relevant
A ANNEX A (INFORMATIVE)
----
ROUTINE TESTS
Description of routine tests to be carried out by the
N/A manufacturer
B ANNEX B (NORMATIVE)
----
APPLIANCES POWERED BY RECHARGEABLE BATTERIES
The following modifications to this standard are
N/A applicable for appliances powered by batteries that are recharged in the appliance
This annex does not apply to battery chargers N/A
3.1.9 Appliance operated under the following conditions: ----
- the appliance, supplied by its fully charged battery,
N/A operated as specified in relevant part 2
- the battery is charged, the battery being initially
N/A discharged to such an extent that the appliance cannot operate
- f possible, the appliance is supplied from the
N/A supply mains through its battery charger, the battery being initially discharged to such an extent that the appliance cannot operate. The appliance is operated as specified in relevant part 2
- if the appliance incorporates inductive coupling
N/A between two parts that are detachable from each other, the appliance is supplied from the supply mains with the detachable part removed
3.6.2 Part to be removed in order to discard the battery is
N/A not considered to be detachable
5.B.101 Appliances supplied from the supply mains tested
N/A as specified for motor-operated appliances
7.1 Battery compartment for batteries intended to be
N/A replaced by the user, marked with battery voltage and polarity of the terminals
The positive terminal indicated by symbol
N/A IEC 60417-5005 and the negative terminal by symbol IEC 60417-5006
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 55
Page 55 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
7.6 Symbols 60417-5005 and IEC 60417-5006
N/A
7.12 The instructions give information regarding charging N/A The instructions for appliances incorporating
N/A batteries intended to be replaced by the user includes required information
Details about how to remove batteries containing
N/A materials hazardous to the environment given
7.15 Markings placed on the part of the appliance
N/A connected to the supply mains
8.2 Appliances having batteries that according to the
N/A instruction may be replaced by the user need only have basic insulation between live parts and the inner surface of the battery compartment
If the appliance can be operated without batteries,
N/A double or reinforced insulation required
11.7 The battery is charged for the period stated in the
N/A
instructions or 24 h ................................................ :
19.1 Appliances subjected to tests of 19.B.101, 19.B.102
N/A and 19.B.103
19.10 Not applicable N/A
19.B.101 Appliances supplied at rated voltage for 168 h, the
N/A battery being continually charged
19.B.102 For appliances having batteries that can be
N/A removed without the aid of a tool, short-circuit of the terminals of the battery, the battery being fully charged,
19.B.103 Appliances having batteries replaceable by the user
N/A supplied at rated voltage under normal operation with the battery removed or in any position allowed by the construction
21.B.101 Appliances having pins for insertion into
N/A socket-outlets have adequate mechanical strength
Part of the appliance incorporating the pins subjected to the free fall test, procedure
----
2, of IEC 60068-2-31, the number of falls being:
- 100, if the mass of the part does not exceed 250 g
N/A
(g) .......................................................................... :
- 50, if the mass of the part exceeds 250 g ........... : N/A
After the test, the requirements of 8.1, 15.1.1, 16.3
N/A and clause 29 are met
22.3 Appliances having pins for insertion into
N/A socket-outlets tested as fully assembled as possible
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 56
Page 56 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
25.13 An additional lining or bushing not required for
N/A interconnection cords in class III appliances or class III constructions operating at safety extra-low voltage not containing live parts
30.2 For parts of the appliance connected to the supply
N/A
mains during the charging period, 30.2.3 applies
For other parts, 30.2.2 applies N/A C ANNEX C (NORMATIVE)
----
AGEING TEST ON MOTORS
Tests, as described, carried out when doubt with
N/A regard to the temperature classification of the insulation of a motor winding
Test conditions as specified N/A D ANNEX D (NORMATIVE)
----
THERMAL MOTOR PROTECTORS
Applicable to appliances having motors that
N/A incorporate thermal motor protectors necessary for compliance with the standard
Test conditions as specified N/A E ANNEX E (NORMATIVE)
----
NEEDLE-FLAME TEST
Needle-flame test carried out in accordance with IEC 60695-11-5, with the following
----
modifications:
7 Severities ---­ The duration of application of the test flame is
P 30 s ± 1 s
9 Test procedure ----
9.1 The specimen so arranged that the flame can be
P applied to a vertical or horizontal edge as shown in the examples of figure 1
9.2 The first paragraph does not apply N/A If possible, the flame is applied at least 10 mm from
P a corner
9.3 The test is carried out on one specimen P If the specimen does not withstand the test, the test
N/A may be repeated on two additional specimens, both withstanding the test
11 Evaluation of test results ---­ The duration of burning not exceeding 30 s P However, for printed circuit boards, the duration of
P burning not exceeding 15 s
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 57
Page 57 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
F ANNEX F (NORMATIVE)
----
CAPACITORS
Capacitors likely to be permanently subjected to the supply voltage, and used for
N/A radio interference suppression or voltage dividing, comply with the following clauses of IEC 60384-14, with the following modifications:
1.5 Terms and definitions ----
1.5.3 Class X capacitors tested according to subclass X2 N/A
1.5.4 This subclause is applicable N/A
1.6 Marking ---­ Items a) and b) are applicable N/A
3.4 Approval testing ----
3.4.3.2 Table 3 is applicable as described N/A
4.1 Visual examination and check of dimensions ---­ This subclause is applicable N/A
4.2 Electrical tests ----
4.2.1 This subclause is applicable N/A
4.2.5 This subclause is applicable N/A
4.2.5.2 Only table 11 is applicable N/A Values for test A apply N/A However, for capacitors in heating appliances the
N/A
values for test B or C apply
4.12 Damp heat, steady state ---­ This subclause is applicable N/A Only insulation resistance and voltage proof are
N/A
checked
4.13 Impulse voltage ---­ This subclause is applicable N/A
4.14 Endurance ---­ Subclauses 4.14.1, 4.14.3, 4.14.4 and 4.14.7 are
N/A
applicable
4.14.7 Only insulation resistance and voltage proof are
N/A
checked
No visible damage N/A
4.17 Passive flammability test ---­ This subclause is applicable N/A
4.18 Active flammability test ---­ This subclause is applicable N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 58
Page 58 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
G ANNEX G (NORMATIVE)
----
SAFETY ISOLATING TRANSFORMERS
The following modifications to this standard are applicable for safety isolating
----
transformers:
7 Marking and instructions ----
7.1 Transformers for specific use marked with: ----
- ame, trademark or identification mark of the
N/A
manufacturer or responsible vendor ..................... :
- model or type reference ...................................... : N/A
17 Overload protection of transformers and associated circuits ---­ Fail-safe transformers comply with subclause 15.5
N/A
of IEC 61558-1
22 Construction ---­ Subclauses 19.1 and 19.1.2 of IEC 61558-2-6 are
N/A
applicable
29 Clearances, creepage distances and solid insulation ----
29.1, 29.2,
29.3 For insulated winding wires complying with
The distances specified in items 2a, 2c and 3 in table 13 of IEC 61558-1 apply
N/A
N/A subclause 19.12.3 of IEC 61558-1 there are no requirements for clearances or creepage distances
For windings providing reinforced insulation, the
N/A distance specified in item 2c of table 13 of IEC 61558-1 is not assessed
For safety isolating transformers subjected to
N/A periodic voltages with a frequency exceeding 30 kHz, the clearances, creepage distances and solid insulation values specified in IEC 60664-4 are applicable, if greater than the values specified in items 2a, 2c and 3 in table 13 of IEC 61558-1
H ANNEX H (NORMATIVE)
----
SWITCHES
Switches comply with the following clauses of IEC 61058-1, as modified below: ---­ The tests of IEC 61058-1 carried out under the
N/A conditions occurring in the appliance
Before being tested, switches are operated 20
N/A times without load
8 Marking and documentation ---­ Switches are not required to be marked N/A However, a switch that can be tested separately
N/A from the appliance marked with the manufacturer’s name or trade mark and the type reference
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 59
Page 59 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
13 Mechanism
---­ The tests may be carried out on a separate sample N/A 15 Insulation resistance and dielectric strength ----
15.1 Not applicable N/A
15.2 Not applicable N/A
15.3 Applicable for full disconnection and
N/A
micro-disconnection 17 Endurance ---­ Compliance is checked on three separate
N/A
appliances or switches For 17.2.4.4, the number of cycles declared
N/A
according to 7.1.4 is 10 000, unless otherwise specified in 24.1.3 of the relevant part 2
N/A
of IEC 60335 ......................................................... :
Switches for operation under no load and which can
N/A
be operated only by a tool, and switches operated by hand that are interlocked so
N/A
that they cannot be operated under load, are not subjected to the tests N/A However, switches without this interlock are
N/A subjected to the test of 17.2.4.4 for 100 cycles of operation
Subclauses 17.2.2 and 17.2.5.2 not applicable N/A The ambient temperature during the test is that
N/A occurring in the appliance during the test of clause 11 in IEC 60335-1
The temperature rise of the terminals not more than
N/A 30 K above the temperature rise measured in
clause 11 of IEC 60335-1 (K)................................ :
20 Clearances, creepage distances, solid insulation and coatings of rigid printed board
----
assemblies
This clause is applicable to clearances and
N/A creepage distances for functional insulation, across full disconnection and micro-disconnection, as stated in table 24
I ANNEX I (NORMATIVE)
---­MOTORS HAVING BASIC INSULATION THAT IS INADEQUATE FOR THE RATED VOLTAGE OF THE APPLIANCE
The following modifications to this standard are applicable for motors having basic
---­insulation that is inadequate for the rated voltage of the appliance:
8 Protection against access to live parts ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 60
Page 60 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
8.1 Metal parts of the motor are considered to be bare
N/A
live parts
11 Heating ----
11.3 The temperature rise of the body of the motor is
N/A determined instead of the temperature rise of the windings
11.8 The temperature rise of the body of the motor,
N/A where in contact with insulating material, not exceeding values in table 3 for the relevant insulating material
16 Leakage current and electric strength ----
16.3 Insulation between live parts of the motor and its
N/A other metal parts is not subjected to the test
19 Abnormal operation ----
19.1 The tests of 19.7 to 19.9 are not carried out N/A
19.I.101 Appliance operated at rated voltage with each of the following fault conditions: ----
- short circuit of the terminals of the motor, including
N/A any capacitor incorporated in the motor circuit
- short circuit of each diode of the rectifier N/A
- open circuit of the supply to the motor N/A
- open circuit of any parallel resistor, the motor
N/A being in operation
Only one fault simulated at a time, the tests carried
N/A out consecutively
22 Construction ----
22.I.101 For class I appliances incorporating a motor
N/A supplied by a rectifier circuit, the d.c. circuit being insulated from accessible parts of the appliance by double or reinforced insulation
Compliance checked by the tests specified for
N/A double and reinforced insulation
J ANNEX J (NORMATIVE)
----
COATED PRINTED CIRCUIT BOARDS
Testing of protective coatings of printed circuit boards carried out in accordance with
----
IEC 60664-3 with the following modifications:
5.7 Conditioning of the test specimens ---­ When production samples are used, three samples
N/A of the printed circuit board are tested
5.7.1 Cold ---­ The test is carried out at -25 °C N/A
5.7.3 Rapid change of temperature ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 61
Page 61 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Severity 1 is specified
N/A
5.9 Additional tests ---­ This subclause is not applicable N/A K ANNEX K (NORMATIVE)
OVERVOLTAGE CATEGORIES
The information on overvoltage categories is
extracted from IEC 60664-1
Overvoltage category is a numeral defining a
transient overvoltage condition
Equipment of overvoltage category IV is for use at
the origin of the installation
Equipment of overvoltage category III is equipment
in fixed installations and for cases where the reliability and the availability of the equipment is subject to special requirements
Equipment of overvoltage category II is energy
consuming equipment to be supplied from the fixed installation
If such equipment is subjected to special
requirements with regard to reliability and availability, overvoltage category III applies
Equipment of overvoltage category I is equipment
for connection to circuits in which measures are taken to limit transient overvoltages to an appropriate low level
----
P
P
N/A
N/A
P
N/A
N/A
L ANNEX L (INFORMATIVE)
---­GUIDANCE FOR THE MEASUREMENT OF CLEARANCES AND CREEPAGE DISTANCES
Information for the determination of clearances and
N/A
creepage distances
M ANNEX M (NORMATIVE)
---­POLLUTION DEGREE
The information on pollution degrees is extracted
P
from IEC 60664-1
Pollution ---­ The microenvironment determines the effect of
P pollution on the insulation, taking into account the macroenvironment
Means may be provided to reduce pollution at the
P insulation by effective enclosures or similar
Minimum clearances specified where pollution may
P be present in the microenvironment
Degrees of pollution in the microenvironment ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 62
Page 62 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
For evaluating creepage distances, the following degrees of pollution in the
----
microenvironment are established:
- pollution degree 1: no pollution or only dry,
N/A non-conductive pollution occurs. The pollution has no influence
- pollution degree 2: only non-conductive pollution
N/A occurs, except that occasionally a temporary conductivity caused by condensation is to be expected
- pollution degree 3: conductive pollution occurs or
P dry non-conductive pollution occurs that becomes conductive due to condensation that is to be expected
- pollution degree 4: the pollution generates
N/A persistent conductivity caused by conductive dust or by rain or snow
N ANNEX N (NORMATIVE)
----
PROOF TRACKING TEST
The proof tracking test is carried out in accordance with IEC 60112 with the
----
following modifications:
7 Test apparatus ----
7.3 Test solutions ---­ Test solution A is used N/A 10 Determination of proof tracking index (PTI) ----
10.1 Procedure ---­ The proof voltage is 100 V, 175 V, 400 V or 600 V
N/A
.............................................................................. :
The test is carried out on five specimens N/A In case of doubt, additional test with proof voltage
N/A reduced by 25 V, the number of drops increased to 100
10.2 Report ---­ The report states if the PTI value was based on a
N/A test using 100 drops with a test voltage of (PTI-25) V
O ANNEX O (INFORMATIVE)
----
SELECTION AND SEQUENCE OF THE TESTS OF clause 30
Description of tests for determination of resistance
P to heat and fire
P ANNEX P (INFORMATIVE)
---­GUIDANCE FOR THE APPLICATION OF THIS STANDARD TO APPLIANCES USED IN WARM DAMP EQUABLE CLIMATES
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 63
Page 63 of 116 Report No.: 160421073GZU-003
considered to be suitable for use in countries having
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Modifications applicable for class 0 and 01 appliances having a rated voltage
---­exceeding 150 V, intended to be used in countries having a warm damp equable climate and that are marked WDaE
Modifications may also be applied to class 1 appliances having a rated voltage
---­exceeding 150 V, intended to be used in countries having a warm damp equable climate and that are marked WDaE, if liable to be connected to a supply mains that excludes the protective earthing conductor
5.7 The ambient temperature for the tests of clauses 11
N/A
and 13 is 40 +3/0 °C
7.1 The appliance marked with the letters WDaE N/A
7.12 The instructions state that the appliance is to be
N/A supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mA
The instructions state that the appliance is
N/A a warm damp equable climate, but may also be
used in other countries
11.8 The values of Table 3 are reduced by 15 K N/A
13.2 The leakage current for class I appliances not
N/A exceeding 0,5 mA
15.3 The value of t is 37 °C N/A
16.2 The leakage current for class I appliances not
N/A exceeding 0,5 mA (mA):
19.13 The leakage current test of 16.2 is applied in
N/A addition to the electric strength test of 16.3
Q ANNEX Q (INFORMATIVE)
----
SEQUENCE OF TESTS FOR THE EVALUATION OF ELECTRONIC CIRCUITS
Description of tests for appliances incorporating electronic circuits N/A R ANNEX R (NORMATIVE)
----
SOFTWARE EVALUATION
Programmable electronic circuits requiring software
N/A incorporating measures to control the fault/error conditions specified in table R.1 or R.2 validated in accordance with the requirements of this annex
R.1 Programmable electronic circuits using software ---­ Programmable electronic circuits requiring software
N/A incorporating measures to control the fault/error conditions specified in table R.1 or R.2 constructed so that the software does not impair compliance with the requirements of this standard
R.2 Requirements for the architecture ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 64
Page 64 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Programmable electronic circuits requiring software
N/A incorporating measures to control the fault/error conditions specified in table R.1 or R.2 use measures to control and avoid software-related faults/errors in safety-related data and safety-related segments of the software
R.2.1.1 Programmable electronic circuits requiring software incorporating measures to
---­control the fault/error conditions specified in table R.2 have one of the following structures:
- single channel with periodic self-test and
N/A
monitoring
- dual channel (homogenous) with comparison N/A
- dual channel (diverse) with comparison N/A Programmable electronic circuits requiring software incorporating measures to
---­control the fault/error conditions specified in table R.1 have one of the following structures:
- single channel with functional test N/A
- single channel with periodic self-test N/A
- dual channel without comparison N/A R.2.2 Measures to control faults/errors ---­R.2.2.1 When redundant memory with comparison is
N/A provided on two areas of the same component, the data in one area is stored in a different format from that in the other area
R.2.2.2 Programmable electronic circuits with functions
N/A requiring software incorporating measures to control the fault/error conditions specified in table R.2 and that use dual channel structures with comparison, have additional fault/error detection means for any fault/errors not detected by the comparison
R.2.2.3 For programmable electronic circuits with functions
N/A requiring software incorporating measures to control the fault/error conditions specified in table R.1 or R.2, means are provided for the recognition and control of errors in transmissions to external safety-related data paths
R.2.2.4 For programmable electronic circuits with functions
N/A requiring software incorporating measures to control the fault/error conditions specified in table R.1 or R.2, the programmable electronic circuits incorporate measures to address the fault/errors in safety-related segments and data indicated in table R.1 and R.2 as appropriate
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 65
Page 65 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
R.2.2.5 For programmable electronic circuits with functions
N/A requiring software incorporating measures to control the fault/error conditions specified in table R.1 or R.2, detection of a fault/error occur before compliance with clause 19 is impaired
R.2.2.6 The software is referenced to relevant parts of the
N/A operating sequence and the associated hardware functions
R.2.2.7 Labels used for memory locations are unique N/A R.2.2.8 The software is protected from user alteration of
N/A safety-related segments and data
R.2.2.9 Software and safety-related hardware under its
N/A control is initialized and terminates before compliance with clause 19 is impaired
R.3 Measures to avoid errors ---­R.3.1 General ---­ For programmable electronic circuits with functions requiring software incorporating
---­measures to control the fault/error conditions specified in table R.1 or R.2, the following measures to avoid systematic fault in the software are applied
Software that incorporates measures used to
N/A control the fault/error conditions specified in table R.2 is inherently acceptable for software required to control the fault/error conditions specified in table R.1
R.3.2 Specification ---­R.3.2.1 Software safety requirements: Software Id: N/A The specification of the software safety
N/A requirements includes the descriptions listed
R.3.2.2 Software architecture ---­R.3.2.2.1 The specification of the software architecture
Document ref. No: N/A includes the aspects listed
- techniques and measures to control software faults/errors (refer to R.2.2);
- interactions between hardware and software;
- partitioning into modules and their allocation to the specified safety functions;
- hierarchy and call structure of the modules (control flow);
- interrupt handling;
- data flow and restrictions on data access;
- architecture and storage of data;
- time-based dependencies of sequences and data
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 66
Page 66 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
R.3.2.2.2 The architecture specification is validated against
N/A the specification of the software safety requirements by static analysis
R.3.2.3 Module design and coding ---­R.3.2.3.1 Based on the architecture design, software is
N/A
suitably refined into modules
Software module design and coding is implemented
N/A in a way that is traceable to the software architecture and requirements
R.3.2.3.2 Software code is structured N/A R.3.2.3.3 Coded software is validated against the module
N/A specification by static analysis
The module specification is validated against the
N/A architecture specification by static analysis
R.3.3.3 Software validation ---­ The software is validated with reference to the
N/A requirements of the software safety requirements specification
Compliance is checked by simulation of: ----
- input signals present during normal operation N/A
- anticipated occurrences N/A
- undesired conditions requiring system action N/A
TABLE R.1 e – GENERAL FAULT/ERROR CONDITIONS
Component
a
1 CPU
1.1 Registers
Fault/error
Stuck at
Acceptable measures
Functional test, or periodic self-test using either:
- static memory test, or
- word protection with single
b, c
Definitions Document
reference
for applied
measure
N/A
H.2.16.5 H.2.16.6 H.2.19.6 H.2.19.8.2
Document
reference
for applied
test
Ver-dic
t
bit redundancy
1.2 VOID N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 67
Page 67 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
1.3 Programme counter
Stuck at Functional test, or
Periodic self-test, or Independent time-slot
monitoring, or Logical monitoring of the
H.2.16.5 H.2.16.6 H.2.18.10.4
H.2.18.10.2
N/A
programme sequence
2 Interrupt handling and execution
3 Clock
4. Memory
4.1 Invariable memory
4.2 Variable memory
No interrupt or too
Functional test, or time-slot monitoring
frequent interrupt
Wrong frequency (for quartz
Frequency monitoring, or time slot monitoring
synchroniz ed clock: harmonics/ sub-harmo nics only)
All single bit faults
Periodic modified checksum, or multiple checksum, or word protection with single bit
redundancy
DC fault Periodic static memory test, or
word protection with single bit redundancy
H.2.16.5 H.2.18.10.4
H.2.18.10.1 H.2.18.10.4
H.2.19.3.1 H.2.19.3.2 H.2.19.8.2
H.2.19.6 H.2.19.8.2
N/A
N/A
N/A
N/A
4.3 Addressing (relevant to
Stuck at Word protection with single bit
redundancy including the address
H.2.19.8.2 N/A
variable and invariable memory)
5 Internal
Stuck at Word protection with single bit
redundancy
H.2.19.8.2 N/A
data path
5.1 VOID N/A
5.2 Addressing
Wrong address
Word protection with single bit redundancy including the
H.2.19.8.2 N/A
address
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 68
Page 68 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
6 External communicat ion
Hamming distance 3
Word protection with multi-bit redundancy, or
CRC – single work, or Transfer redundancy, or
H.2.19.8.1
H.2.19.4.1 H.2.18.2.2
N/A
Protocol test
H.2.18.14
6.1 VOID N/A
6.2 VOID N/A
6.3 Timing
7 Input/output periphery
Wrong point in time
Wrong sequence
Fault conditions specified in
Time-slot monitoring, or scheduled transmission Time-slot and logical
monitoring, or comparison of redundant
communication channels by either:
- reciprocal comparison
- independent hardware
comparator Logical monitoring, or time-slot monitoring, or Scheduled transmission
H.2.18.10.4 H.2.18.18 H.2.18.10.3
H.2.18.15 H.2.18.3
H.2.18.10.2 H.2.18.10.4 H.2.18.18
N/A
Plausibility check H.2.18.13 N/A
19.11.2
7.1 VOID N/A
7.2 Analog I/O
7.2.1 A/D and D/A­converter
7.2.2 Analog
Fault conditions specified in
19.11.2 Wrong
addressing
Plausibility check
H.2.18.13
N/A
Plausibility check H.2.18.13 N/A
multiplexer 8 VOID N/A 9
Custom chips d e.g. ASIC, GAL, gate array
Any output outside the static and dynamic functional
Periodic self-test H.2.16.6 N/A
specificatio n
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 69
Page 69 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
NOTE A Stuck-at fault model denotes a fault model representing an open circuit or a non-varying signal level. A DC fault model denotes a stuck-at fault model incorporating short circuit between signal lines.
a)
For fault/error assessment, some components are divided into their sub-functions.
b)
For each sub-function in the table, the Table R.2 measure will cover the software fault/error.
c)
Where more than one measure is given for a sub-function, these are alternatives.
d)
To be divided as necessary by the manufacturer into sub-functions.
e)
Table R.1 is applied according to the requirements of R.1 to R.2.2.9 inclusive.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 70
Page 70 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
10.1 TABLE: Power input deviation
Input deviation of/at: P rated (W) P measured (W)
P Required P
P
Remark
24VDC 36 26,9 -25,3% +20% ES071-1AE 24VDC 36 31,2 -13,4% +20% ES800 Remark: for 20+5°C
10.2 TABLE: Current deviation for Airtek models
Current deviation of/at: I rated (A) I measured (A) I
Required I
P
Remark
24VDC 1,5 1,121 -25,2% +20% ES071-1AE 24VDC 1,5 1,299 -13,4% +20% ES800 Remark: for 20+5°C
11.8-1
TABLE: Heating test, thermocouples for model ES071-1AE
Test voltage (V) ........................................................ : 25,44V, 50Hz
Ambient (°C) ............................................................. :
24,8-25,2
P
 
Thermocouple locations dT (K) Max. dT (K) Pin connection 1,1 45 Surface of appliance inlet 1,0 For reference DC fan motor winding 35,8 80 Class 120 DC fan motor enclosure 25,4 For reference PCB of DC fan motor 33,3 120 Plastic bracket for fan motor 1,5 For reference Control PCB 4,8 120 Quick connector on PCB 3,6 For reference Sync.motor surface 22,2 For reference Internal wire 0,9 50 Enclosure of water pump 1,4 For reference Control panel 2,4 75 Appliance enclosure 1,0 75 Handle 1,2 60 Internal wire to appliance inlet 0,9 50 Test corner 1,0 65
11.8-1 TABLE: Heating test, resistance method P
Test voltage (V) ........................................................ : 25,44V
Ambient, t1 (°C) ......................................................... :
Ambient, t2 (°C) ......................................................... :
24,8 25,0
  
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 71
Page 71 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Temperature rise of winding R1 () R2 () dT (K) Max. dT (K) Insulation
class
Synchronous motor winding 67,7 82,5 56,5 75 Class 105
11.8-2
TABLE: Heating test, thermocouples for model ES800
Test voltage (V) ........................................................ : 25,44VDC
Ambient (°C) ............................................................. :
23,5 – 23,0 Thermocouple locations dT (K) Max. dT (K) Pin connection 2,3 45 Surface of appliance inlet 2,2 For reference Internal wire to appliance inlet 2,6 50 DC fan motor winding #1 67,6 80 Class 120 DC fan motor winding #2 67,9 80 Class 120 PCB of DC fan motor 53,3 120 Plastic bracket for fan motor 22,7 For reference Control PCB 9,7 120 Quick connector on PCB 5,1 For reference Sync.motor surface 15,7 For reference Internal wire 3,8 50 Control panel 3,3 75
P
 
Appliance enclosure 1,2 75 Enclosure of water pump 1,1 For reference Test corner 1,8 65
11.8-2 TABLE: Heating test, resistance method P
Test voltage (V) ........................................................ : 25,44VDC
Ambient, t1 (°C) ......................................................... :
Ambient, t2 (°C) ......................................................... :
21,9 23,1
  
Temperature rise of winding R1 () R2 () dT (K) Max. dT (K) Insulation
class
Synchronous motor winding 67,4 77,3 36,3 75 Class 105
13.2 TABLE: Leakage current N/A
Heating appliances: 1,15 x rated input (W) .......: ----
Motor-operated and combined appliances:
----
 
1,06 x rated voltage (V) .....................................:
Leakage current between I (mA) Max. allowed I (mA)
---- ---- ----
Supplementary information: --
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 72
Page 72 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
13.3 TABLE: Electric strength N/A
Test voltage applied between: Test potential applied
(V)
Breakdown / flashover
(Yes/No)
---- ---- ----
Supplementary information: --
14 TABLE: Transient overvoltages N/A
Clearance between: Cl (mm) Required Cl
(mm)
Rated impulse
voltage (V)
Impulse test
voltage (V)
Flashover
(Yes/No)
---- ---- ---- ---- ---- ---­Supplementary information: --
16.2 TABLE: Leakage current N/A
Single phase appliances: 1,06 x rated voltage (V)
----
...........................................................................:
Three phase appliances 1,06 x rated voltage
----
divided by 3 (V) ................................................:
Leakage current between I (mA) Max. allowed I (mA)
---- ---- ----
Remark: record the max. value
16.3 TABLE: Dielectric strength N/A
Test voltage applied between: Test potential applied
(V)
Breakdown / flashover
(Yes/No)
---- ---- ----
Supplementary information: --
17 TABLE: Overload protection N/A
Thermocouple locations Max. temperature rise
measured, T (K)
Max. temperature rise
limit, T (K)
---- ---- ---­Supplementary information:
17 TABLE: Overload protection, resistance method N/A
Test voltage (V) ..................................................... :
Ambient, t1 (°C)..................................................... :
Ambient, t2 (°C)..................................................... :
Temperature of winding R1 () R2 () T (K)
----
----
---­T (°C)
  
Max. T (°C)
---- ---- ---- ---- ---- ----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 73
Page 73 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Supplementary information:
19 Abnormal operation conditions P
Operational characteristics YES/NO Operational conditions Are there electronic circuits to control
YES Short-circuit for some component
the appliance operation? Are there “off” or “stand-by” position? YES N/A The unintended operation of the
NO N/A appliance results in dangerous malfunction?
Sub-claus e
Operating conditions
description
Test results
description
PEC
description
EMP
19.11.4
Software
type
required
19.11.3 PEC
Final
result
19.2 N/A N/A N/A N.A N/A N/A N/A
19.3 N/A N/A N/A N/A N/A N/A N/A
19.4 N/A N/A N/A N/A N/A N/A N/A
19.5 N/A N/A N/A N/A N/A N/A N/A
19.6 N/A N/A N/A N.A N/A N/A N/A
19.7 N/A N/A N/A N/A N/A N/A N/A
19.8 N/A N/A N/A N/A N/A N/A N/A
19.9 N/A N/A N/A N/A N/A N/A N/A
19.10 N/A N/A N/A N/A N/A N/A N/A
19.11.2 N/A N/A N/A N/A N/A N/A P
19.11.4.8 N/A N/A N/A N/A N/A N/A N/A
19.10X N/A N/A N/A N/A N/A N/A N/A Supplementary information: --
19.7 TABLE: Abnormal operation, locked rotor/moving parts P
Test voltage (V) ....................................................... : 24V
Ambient, t1 (°C) ........................................................ :
Ambient, t2 (°C) ........................................................ :
Temperature of winding R1 () R2 () dT (K)
See below See below
T (°C)
Max. T (°C) Lock rotor/moving parts, ambient: (t1: 24,3°C; t2: 24,3°C) DC fan motor winding --- --- --- 45,2 175 Remark: Impedance protected, no hazards. Lock rotor/moving parts of Synchronous motor, ambient: (t1: 19,2°C; t2: 19,1°C) Winding of Synchronous motor 67,7
(24,8°C)
80,9
(24,7°C)
50,7 75,3 165
Remark: Impedance protected.
  
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 74
Page 74 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Lock rotor/moving parts of water pump, ambient: (t
: 24,8°C; t2: 23,7°C)
1
Water pump surface --- --- --- 24,0 150 Remark: Until steady conditions established.
19.9 TABLE: Abnormal operation, running overload
Test voltage (V) ..................................................... :
Ambient, t1 (°C) .................................................... :
Ambient, t2 (°C) .................................................... :
Temperature of winding R1 () R2 () T (K)
----
----
---­T (°C)
Max. T (°C)
---- ---- ---- ---- ---- ---­Supplementary information:
19.13 TABLE: Abnormal operation, temperature rises
Thermocouple locations Max. temperature rise
measured, T (K)
Max. temperature rise
limit, T (K)
--- --- --­Supplementary information: ---
21.1 TABLE: Impact resistance P
N/A
  
N/A
Impacts per surface Surface tested Impact energy (Nm) Comments
3 Plastic enclosure 0,5 Pass 3 Control panel 0,5 pass
Supplementary information: ---
24.1 TABLE: Components P Object / part
No. Quick
connector of DC fan motor
DC socket of ES071-1AE
DC socket of ES800
Manufacturer/ trademark
Yueqing changshun electronic co ltd
XUNXINXIN electronic co ltd
Dongguanyiyu electronics
Type / model Technical data Standard Mark(s) of
conformity
CS25002(XH) DC500V IEC 60335-1
IEC 60335-2-
Tested with appliance
80/98
DC005 14,3x9x11mm;
1.65MM; DC 30V/2A
DC-022 --- IEC 60335-1
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-2-
Tested with appliance
Test with appliance
80/98
Fan motor Airtek international
corporation limited
YZD-MS001 Input: 24VDC;
30W; 1,25A; output: 15W ,
IEC 60335-1 IEC 60335-2­80/98
Tested with appliance
class 130
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 75
Page 75 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Swing motor Airtek international
corporation limited
Water pump Airtek international
corporation limited
Internal wire #1 GUANGZHOU ZHIHE
ELECTRONIC CO
TYC50C 18VAC; 50Hz;
5/min <4W
R-001 24VDC; 2,5W;
class120
1007 24-18AWG;
300V; 80°C
LTD
Alternative DONGGUAN CHENG
XING ELECTRONIC
1007 24-18AWG;
300V; 80°C
CO LTD
Alternative GUANGDONG
ZHONGSHAN YIXIN
1007 24-18AWG;
300V; 80°C ELECTRICAL CO LTD
Alternative GUANG DONG XIN
LONG ENTERPRISE CO
1007
24-18AWG;
300V; 80°C
Alternative Various 1007 24-18AWG;
300V; 80°C
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
Tested with appliance
Tested with appliance
Tested with appliance & UL E251728
Tested with appliance & UL E249743
Tested with appliance & UL E351034
Tested with appliance & UL E207567
S & other EU certification marks
Internal wire 2# GUANG DONG XIN
LONG ENTERPRISE CO
Alternative DONGGUAN CHENG
XING ELECTRONIC
2468
26-18AWG;
300V; 80°C
2468 26-18AWG;
300V; 80°C CO LTD
Alternative GUANGZHOU ZHIHE
ELECTRONIC CO
2468 26~18AWG;
300V; 80°C LTD
Alternative GUANGDONG
ZHONGSHAN YIXIN
2468 26~18AWG;
300V; 80°C ELECTRICAL CO LTD
Alternative Various 2468 26~18AWG;
300V; 80°C
PCB board SHANDONG JINBAO
ZD-95F V-0; 130°C IEC 60335-1 ELECTRONICS CO., LTD
Alternative ZHONGSHAN LIXIN
FR-1 V-0; 130°C IEC 60335-1 CHAIN-BOARD CO., LTD
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-2­80/98
IEC 60335-2­80/98
Tested with appliance & UL E207567
Tested with appliance & UL E249743
Tested with appliance & UL E251728
Tested with appliance & UL E351034
S & other EU certification marks
Tested with appliance & UL E141940
Tested with appliance & UL E230073
Alternative SHUNDE JUN'AN
SHENGSHENG ELECTRONIC CO.,
S-V01 V-0; 130°C IEC 60335-1
IEC 60335-2­80/98
Tested with appliance & UL E240257
LTD.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 76
Control panel stickers of ES071-1AE
Page 76 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Maoming sakata inx Co., Ltd.
Base material
PVC +surface
printing ink
--- IEC 60335-1 IEC 60335-2­80/98
Test with appliance
Top cover of ES071-1AE
Plastic enclosure of ES071-1AE
Rear grille of ES071-1AE
DC motor bracket
Vertical louver blade ES071­1AE
Control panel of ES071-1AE
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Test with appliance &
UL E67171
Top cover/ water pump front panel/ Louver Blade/ rear grille/ handle of ES800
Plastic enclosure of ES800
Control panel of ES800
Lead wire of Water tank switch /Low water alarm device for ES800 (optional )
Alternative
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
LG CHEM LTD HI121(#) HB, 95 °C IEC 60335-1
IEC 60335-2­80/98
DONGGUAN NANSI CABLE AND WIRE CO LTD
SHENZHEN YIMEITE ELECTRIC CABLE CO LTD
2464 80°C; 300V;
24AWG
2464 80°C; 300V;
24AWG
IEC 60335-1 IEC 60335-2-
80/98
IEC 60335-1 IEC 60335-2-
80/98
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Tested with appliance & UL E67171
Tested with appliance & UL E468498
Tested with appliance & UL E 318342
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 77
Page 77 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Lead wire of Water level LED light for
GUANG DONG XIN LONG ENTERPRISE CO
2468
26-18AWG; 300V; 80°C
ES800 (optional )
Alternative DONGGUAN CHENG
XING ELECTRONIC
2468 26-18AWG;
300V; 80°C
CO LTD
Alternative GUANGZHOU ZHIHE
ELECTRONIC CO
2468 26~18AWG;
300V; 80°C
LTD
Alternative GUANGDONG
ZHONGSHAN YIXIN
2468 26~18AWG;
300V; 80°C ELECTRICAL CO LTD
Alternative Various 2468 26~18AWG;
300V; 80°C
Note: this appliance can be powered by the following adapter mode Adapter Foshan city Dizhi
power supply Co., Ltd.
DSS36­2401500-H
Input: AC 100-
240V; 50/60Hz;
1,5A; Output:
24V; 1,5A; Class
II
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC 60335-1 IEC 60335-2­80/98
IEC/EN 61558-2­16
Tested with appliance & UL E207567
Tested with appliance & UL E249743
Tested with appliance & UL E251728
Tested with appliance & UL E351034
S & other EU certification marks
TUV Rheinland S 50316491
Alternative Dongguan yuan shuai
electronic Co., Ltd
YeS36W­2400150V
Input :100-
240V~; 50/60Hz;
1,0A Max;
IEC/EN 61558-2­16
Intertek 16HKS0430-
01 Output : 24V; 1,5A; Class II
Alternative Various Various Input: AC 100-
240V; 50/60Hz; 1,5A or 1,0A;
IEC/EN 61558-2­16
S & other EU
certification
marks Output: 24V; 1,5A; Class II
Supplementary information:
1
) Provided evidence ensures the agreed level of compliance. See OD-CB2039.
28.1 TABLE: Threaded part torque test
Threaded part identification
Diameter of thread
(mm)
Column number
(I, II, or III)
Applied torque (Nm)
Fixing screw 3,37 II 0,8 Supplementary information: --
29.1 TABLE: Clearances P
P
Overvoltage category ............................................ : II
Type of insulation:
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 78
Page 78 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
Rated impulse
voltage (V):
330 0,2* / 0,5 / 0,8** 500
800 0,2* / 0,5 / 0,8** 1 500 0,5 / 0,8** / 1,0*** 2 500
Min. cl (mm) Basic
(mm)
0,2* / 0,5 / 0,8**
1,5 / 2,0***
Supplementary
(mm)
Reinforced
(mm)
Functional
(mm)
Verdict / Remark
-- -- -- -- N/A
-- -- -- 3,2 P
-- -- -- -- N/A
-- -- -- -- N/A
-- -- -- -- N/A 4 000 3,0 / 3,5*** -- -- -- -- N/A 6 000 5,5 / 6,0*** -- -- -- -- N/A 8 000 8,0 / 8,5*** -- -- -- -- N/A
10 000 11,0 / 11,5*** -- -- -- -- N/A Supplementary information: *) For tracks on printed circuit boards if pollution degree 1 and 2
**) For pollution degree 3 ***) If the construction is affected by wear, distortion, movement of the parts or during assembly
29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation
N/A
Working voltage
(V)
Creepage distance
(mm)
Pollution degree
1 2 3 Type of insulation Verdict
Material group Material group
50 50 50
125 125 125
I II IIIa/IIIb 0,18 0,6 0,85 0,18 0,6 0,85
1,2 1,5 1,7 1,9
1,2 1,5 1,7 1,9 0,36 1,2 1,7 2,4 3,0 3,4 3,8 0,28 0,75 1,05 0,28 0,75 1,05
1,5 1,9 2,1 2,4
1,5 1,9 2,1 2,4 0,56 1,5 2,1 3,0 3,8 4,2 4,8
I II IIIa/IIIb* B** S** R**
250 0,56 1,25 1,8 2,5 3,2 3,6 4,0 250 0,56 1,25 1,8 2,5 3,2 3,6 4,0 250 1,12 2,5 3,6 5,0 6,4 7,2 8,0 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3 400 1,0 2,0 2,8 4,0 5,0 5,6 6,3
  
  
  
 
N/A
 
 
N/A N/A
N/A
N/A N/A
N/A N/A
N/A
N/A
N/A 400 2,0 4,0 5,6 8,0 10,0 11,2 12,6 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 500 1,3 2,5 3,6 5,0 6,3 7,1 8,0 500 2,6 5,0 7,2 10,0 12,6 14,2 16,0
 
    
N/A
N/A
N/A
N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 79
Page 79 of 116 Report No.: 160421073GZU-003
 
 
 
Modification 1: October 12, 2016
29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation
Working voltage
(V)
Creepage distance
(mm)
Pollution degree
1 2 3 Type of insulation Verdict
Material group Material group
>630 and 800 >630 and 800
>630 and 800 >800 and 1000 >800 and 1000 >800 and 1000
>1000 and 1250 >1000 and 1250 >1000 and 1250 >1250 and 1600
I II IIIa/IIIb 1,8 3,2 4,5 6,3 8,0 9,0 10,0 1,8 3,2 4,5 6,3 8,0 9,0 10,0 3,6 6,4 9,0 12,6 16,0 18,0 20,0 2,4 4,0 5,6 8,0 10,0 11,0 12,5 2,4 4,0 5,6 8,0 10,0 11,0 12,5 4,8 8,0 11,2 16,0 20,0 22,0 25,0 3,2 5,0 7,1 10,0 12,5 14,0 16,0 3,2 5,0 7,1 10,0 12,5 14,0 16,0 6,4 10,0 14,2 20,0 25,0 28,0 32,0 4,2 6,3 9,0 12,5 16,0 18,0 20,0
I II IIIa/IIIb* B** S** R**
    
    
    
 
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
>1250 and 1600 >1250 and 1600 >1600 and 2000 >1600 and 2000 >1600 and 2000 >2000 and 2500 >2000 and 2500 >2000 and 2500 >2500 and 3200 >2500 and 3200 >2500 and 3200 >3200 and 4000 >3200 and 4000 >3200 and 4000 >4000 and 5000 >4000 and 5000
4,2 6,3 9,0 12,5 16,0 18,0 20,0 8,4 12,6 18,0 25,0 32,0 36,0 40,0 5,6 8,0 11,0 16,0 20,0 22,0 25,0 5,6 8,0 11,0 16,0 20,0 22,0 25,0
11,2 16,0 22,0 32,0 40,0 44,0 50,0
7,5 10,0 14,0 20,0 25,0 28,0 32,0
7,5 10,0 14,0 20,0 25,0 28,0 32,0 15,0 20,0 28,0 40,0 50,0 56,0 64,0 10,0 12,5 18,0 25,0 32,0 36,0 40,0 10,0 12,5 18,0 25,0 32,0 36,0 40,0 20,0 25,0 36,0 50,0 64,0 72,0 80,0 12,5 16,0 22,0 32,0 40,0 45,0 50,0 12,5 16,0 22,0 32,0 40,0 45,0 50,0 25,0 32,0 44,0 64,0 80,0 90,0 100,0 16,0 20,0 28,0 40,0 50,0 56,0 63,0 16,0 20,0 28,0 40,0 50,0 56,0 63,0
  
    
    
    
  
  
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
>4000 and 5000 >5000 and 6300 >5000 and 6300 >5000 and 6300
32,0 40,0 56,0 80,0 100,0 112,0 126,0 20,0 25,0 36,0 50,0 63,0 71,0 80,0 20,0 25,0 36,0 50,0 63,0 71,0 80,0 40,0 50,0 72,0 100,0 126,0 142,0 160,0
  
N/A
N/A
N/A
N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 80
Page 80 of 116 Report No.: 160421073GZU-003
 
 
 
Modification 1: October 12, 2016
29.2 TABLE: Creepage distances, basic, supplementary and reinforced insulation
Working voltage
(V)
Creepage distance
(mm)
Pollution degree
1 2 3 Type of insulation Verdict
Material group Material group
>6300 and 8000 >6300 and 8000
>6300 and 8000 >8000 and 10000 >8000 and 10000 >8000 and 10000
>10000 and 12500 >10000 and 12500 >10000 and 12500
I II IIIa/IIIb 25,0 32,0 45,0 63,0 80,0 90,0 100,0 25,0 32,0 45,0 63,0 80,0 90,0 100,0 50,0 64,0 90,0 126,0 160,0 180,0 200,0 32,0 40,0 56,0 80,0 100,0 110,0 125,0 32,0 40,0 56,0 80,0 100,0 110,0 125,0 64,0 80,0 112,0 160,0 200,0 220,0 250,0 40,0 50,0 71,0 100,0 125,0 140,0 160,0 40,0 50,0 71,0 100,0 125,0 140,0 160,0 80,0 100,0 142,0 200,0 250,0 280,0 320,0
I II IIIa/IIIb* B** S** R**
 
 
 
Supplementary information:
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
*) Material group IIIb is allowed if the working voltage does not exceed 50 V
29.2 TABLE: Creepage distances, functional insulation
Working voltage
(V)
Creepage distance
(mm)
Pollution degree 1 2 3 Material group Material group I II IIIa/IIIb
10
0,08 0,4 0,4 0,4 1,0 1,0 1,0 N/A
I II IIIa/IIIb*
50 0,16 0,56 0,8 1,0 1,4 1,6 125 0,25 0,71 1,0 1,4 1,8 2,0 2,2 N/A 250 0,42 1,0 1,4 2,0 2,5 2,8 3,2 N/A 400 0,75 1,6 2,2 3,2 4,0 4,5 5,0 N/A 500 1,0 2,0 2,8 4,0 5,0 5,6 6,3 N/A
>630 and 800
>800 and 1000
1,8 3,2 4,5 6,3 8,0 9,0 10,0 N/A 2,4 4,0 5,6 8,0 10,0 11,0 12,5 N/A
1,8
P
)
Verdict / Remark
P/ 3,2mm
>1000 and 1250 >1250 and 1600 >1600 and 2000 >2000 and 2500
3,2 5,0 7,1 10,0 12,5 14,0 16,0 N/A 4,2 6,3 9,0 12,5 16,0 18,0 20,0 N/A 5,6 8,0 11,0 16,0 20,0 22,0 25,0 N/A 7,5 10,0 14,0
20,0 25,0 28,0 32,0 N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 81
Page 81 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
>2500 and 3200 >3200 and 4000 >4000 and 5000 >5000 and 6300 >6300 and 8000
>8000 and 10000
>10000 and 12500
10,0 12,5 16,0 22,0 16,0 20,0 28,0 20,0 25,0 36,0 25,0 32,0 45,0 32,0 40,0 56,0 40,0 50,0 71,0 100,0 125,0 140,0 160,0
12,5 18,0
25,0 32,0 36,0 40,0 N/A 32,0 40,0 45,0 50,0 N/A 40,0 50,0 56,0 63,0 N/A 50,0 63,0 71,0 80,0 N/A 63,0 80,0 90,0 100,0 80,0 100,0 110,0 125,0
Supplementary information: *) Material group IIIb is allowed if the working voltage does not exceed 50 V
N/A N/A N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 82
Page 82 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
30 Object/
part No.
75 125 cl. 11
Plastic
TABLE: Resistance to heat and fire Manufacturer/
trademark
Type/ model
Ball pressure test
--- --- P ---
°C
+40
cl. 19
+25
550 650 750 85
--- --- P ---
enclosure Quick
--- --- --- P --- --- --- ---
connector DC socket --- --- --- P --- --- --- ---
Water
--- --- P ---
--- --- P --­pump enclosure
Electric
--- --- P ---
--- --- P --­box
Glow wire test
(GWT)
°C
t
e
t
i
te t
---
---
---
No flame
---
3,0
s
---
---
---
---
---
2,
6s
---
---
i
Glow-wire
flammability index
(GWFI)
°C
Glow- wire
ignition
temp.
(GWIT)
Needle-
flame
test
(NFT)
°C
550 650 750 850 675 775
0
--- ---
P
---
P
---
--- ---
--- ---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
--- ---
---
---
---
---
---
--- P
--- ---
--- --- P
---
---
--- P
P P
Verdict
P
Fan motor
--- --- P ---
--- --- P ---
---
---
---
--- ---
---
---
---
---
---
--- P
bracket PCB --- --- --- P --- --- --- ---
---
---
---
--- ---
---
---
---
---
---
P P
Supplementary information:
1)
Parts of material classified at least HB40 or if relevant HBF
2)
Parts of material classified as V-0 or V-1
3)
Flame persisting longer than 2 s (= te – ti) need only be reported for unattended appliances
4)
Surrounding parts subjected to the needle-flame test of annex E
5)
Base material classified as V-0 or if relevant VTM-0
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 83
Page 83 of 116 Report No.: 160421073GZU-003
6)
The GWIT pre-selection option, the 850 °C GWFI pre-selection option, and the 850 °C GWT are not applicable for attended appliances
Modification 1: October 12, 2016
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 84
Page 84 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Appendix EMF
P
TEST: Evaluation of the magnetic fields
— Applied standards: IEC 62233:2005, EN 62233:2008 (incl. Corr.1:2008) — Method Used method: 5.5.2 Time domain evaluation — Applied Limit ICNIRP Guidelines — Identification of the appliance Type of apparatus Evaporative air cooler
Rated Voltage 24 Rated Frequency
Parameters required prior to the test Laboratory Ambient Temperature
25 °C ± 10 °C Supply Voltage (Rated Voltage ± 2 %) V Supply Frequency (Rated Frequency ± 2 %) Hz
Parameters recorded during the test Laboratory Ambient Temperature
25 Supply Voltage 24 Supply Frequency
Operating Mode Normal operation Method 5.5.2
Measuring Positions Measuring Distance Coupling Factor Measurement Uncertainty
Around 30cm
Frequency (kHz) Limit (%) Measured Maximum Value (%)
0,01 to 400 100 0,220 Supplementary information: The measured maximum value in this table may be weighted with the coupling factor if applicable, and the
measurement uncertainty is applied if the measured result is more than 75 % of the limit.
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 85
Page 85 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Appendix to TRF no. IEC60335_2_98E
IEC 60335-2-80:2002 + A1:2004 + A2:2008 Clause Requirement – Test Result – Remark Verdict 5 GENERAL CONDITIONS FOR THE TESTS
5.7 Fans intended to be used in tropical climates, tests of
---
N/A
clauses 10, 11 and 13 are carried out at 40 °C +/- 2 °C (IEC/EN 60335-2-80)
Fans marked with an ambient operating temperature,
N/A
tests of clauses 10, 11 and 13 are carried out at the marked value +/- 2 °C (IEC/EN 60335-2-80/ A1)
6 CLASSIFICATION
6.2 Duct fans shall be at least IP X2
---
N/A
(IEC/EN 60335-2-80)
6.101
Classification to climatic conditions : temperate
Temperate climates
P
climates, tropical climates (IEC/EN 60335-2-80)
7 MARKING AND INSTRUCTIONS
7.1
For tropical climates marked with letter T
---
N/A
(IEC/EN 60335-2-80) Fans operating at local temperature exceeding 40 °C
N/A marked with ambient operating temperature (IEC/EN 60335-2-80/ A1)
8 PROTECTION AGAINST ACCESS TO LIVE PARTS
8.2 Removal of detachable parts after user maintenance,
---
N/A basic insulation may be touched provided that wiring
is electrically equivalent with IEC 60227 or IEC 60245 (IEC/EN 60335-2-80/A1)
15 MOISTURE RESISTANCE
15.1.1 The outer part of fans to be installed in the external
---
N/A structure is subjected to subclause 14.2.4(a) of IEC
60529. (IEC/EN 60335-2-80/A1)
19 ABNORMAL OPERATION
19.1
Fans incorporating shutters or similar subjected to
--­P
the test of cl. 19.101 (IEC/EN 60335-2-80)
19.9 Not applicable (IEC/EN 60335-2-80)
19.101
Fans incorporating shutters or similar that are
N/A
P
operated automatically are supplied at rated voltage in the closed or open position, whichever is more unfavourable (IEC/EN 60335-2-80)
20 STABILITY AND MECHANICAL HAZARDS
20.101
Fan blades, other than those for mounting at high
--­P
level, shall be guarded, unless ...............................
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 86
Page 86 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
(IEC/EN 60335-2-80)
21 MECHANICAL STRENGTH
21.101
Fan guards are subjected to a push and pull force of
--­P
20 N. Dangerous moving parts are not accessible (IEC/EN 60335-2-80)
(Addition:)
P
The test probe is applied with a force not exceeding 5 N. (IEC/EN 60335-2-80/A2)
21.102
Ceiling fans have adequate strength. Load four times
mass (.......) (IEC/EN 60335-2-80)
22 CONSTRUCTION
22.101
Appliances having provision for attaching a luminaire incorporate appropriate terminals and internal wiring (IEC/EN 60335-2-80)
23 INTERNAL WIRING
23.3
No damage after 100 000 flexings for conductors flexed during normal use and at rated voltage (IEC/EN 60335-2-80)
24 COMPONENTS
24.2
Switches or automatic controls in flexible cords are allowed for appliances not exceeding 25 W (IEC/EN 60335-2-80)
24.101
Thermal cut-outs in duct fans in order to comply with cl. 19 are not self-resetting (IEC/EN 60335-2-80)
25 SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS
25.5 - type Z attachment is allowed for portable fans (IEC/EN 60335-2-80)
29 CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION
29.2
Microenvironment is pollution degree 3 unless insulation is enclosed or located that it is unlikely to be exposed to pollution during normal use (IEC/EN 60335-2-80)
N/A
---
N/A
---
N/A
---
N/A
N/A
---
N/A
---
N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 87
Page 87 of 116 Report No.: 160421073GZU-003
appliance in a safe way and understand the hazards
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
ATTACHMENT TO TEST REPORT IEC 60335-2-98
EUROPEAN GROUP DIFFERENCES AND NATIONAL DIFFERENCES
Household and similar electrical appliances – Safety –
Part 2-98: Particular requirements for humidifiers
Differences according to :
EN 60335-2-98:2003 + A1:2005 + A2:2008 EN 60335-2-80:2003 + A1:2004 +A2:2009 EN 60335-1:2012 + A11:2014
Attachment Form No. : Attachment Originator : Master Attachment :
EU_GD_IEC60335_2_98E VDE 2013-06
Copyright © 2013 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.
CENELEC COMMON MODIFICATIONS
6.1 Delete “class 0” and “class 01” N/A
7.1 Single-phase appliances to be connected to the
P
supply mains: 230 V covered
Multi-phase appliances to be connected to the
N/A
supply mains: 400 V covered
7.10 Devices used to start/stop operational functions of
P the appliance distinguished from other manual devices by means of shape, size, surface texture, position, etc.
An indication that the device has been operated is given by: ----
- a tactile feedback, or P
- an audible and visual feedback P
7.12 The instructions include the substance of the following: ----
- this appliance can be used by children aged from
P 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the
involved
- children shall not play with the appliance P
- cleaning and user maintenance shall not be made
P by children without supervision
7.12.Z1 The specific instructions related to the safe
P operation of this appliance is collated together in the front section of the user instructions
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 88
Page 88 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
The height of the characters, measured on the
P capital letters, is at least 3 mm
These instructions are also available in an
P alternative format, e.g. on a website
8.1.1 Also test probe 18 of EN 61032 is applied N/A The appliance being in every possible position
N/A during the test
The force on the probe in the straight position is
N/A increased to 10 N when probe 18 is used
When using test probe 18 the appliance is fully
N/A assembled as in normal use without any parts removed, and
parts intended to be removed for user maintenance
N/A are also not removed
8.2 Compliance is checked by applying the test probes
N/A of EN 61032
For built-in appliances and fixed appliances, the test
N/A probe B and probe 18 of EN 61032 are applied only after installation
11.8 Footnotes to “External enclosure of motor-operated
P appliances” to be taken into account
15.1.2 Appliances with an automatic cord reel tested with
N/A the cord in the most unfavourable position so that the reeling of the wet cord may affect electrical insulation during operation, the cord not being dried before reeling
20.2 When using the test probe similar to test probe B
P with a circular stop face, the accessories and detachable covers are removed
Test probe 18 applied with a force of 2,5 N on the
P appliance fully assembled
24.1 Components comply with the safety requirements
P specified in the relevant standards as far as they reasonably apply
The requirements of clause 29 of this standard
P apply between live parts of components and accessible parts of the appliance.
The requirements of 30.2 of this standard apply to
P parts of non-metallic material in components including parts of non-metallic material supporting current-carrying connections inside components
Components that have not been previously tested
P or do not comply with the standard for the relevant component are tested according to the requirements of 30.2
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 89
Page 89 of 116 Report No.: 160421073GZU-003
additional tests specified in the relevant standard for
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Components that have been previously tested and shown to comply with the
---­resistance to fire requirements in the standard for the relevant component need not be retested provided that:
- the severity specified in the component standard is not less than the severity specified in 30.2, and
- the test report for the component states whether it complied with the standard for the relevant component with or without flame, flames not exceeding 2 s during the test are ignored
Unless components have been previously tested
and found to comply with the relevant standard for the number of cycles specified, they are tested in accordance with 24.1.1 to 24.1.9
For components mentioned in 24.1.1 to 24.1.9, no
the component are necessary other than those specified in 24.1.1 to 24.1.9
Components that have not been separately tested
and found to comply with the relevant standard, and
components that are not marked or not used in
accordance with their marking,
are tested in accordance with the conditions
occurring in the appliance, the number of samples being that required by the relevant standard
Lamp holders and starter holders that have not
been previously tested and found to comply with the relevant standard are tested as a part of the appliance and additionally comply with the gauging and interchangeability requirements of the relevant standard under the conditions occurring in the appliance
N/A
N/A
P
P
P
N/A
P
N/A
Where the relevant standard specifies these
gauging and interchangeability requirements at elevated temperatures, the temperatures measured during the tests of clause 11 are used
Plugs and socket-outlets and other connecting
devices of interconnection cords are not interchangeable with plugs and socket-outlets listed in IEC/TR 60083 or IEC 60906-1, or
with connectors and appliance inlets complying with
the standard sheets of IEC 60320-1,
if direct supply to these parts from the supply mains
gives rise to a hazard
24.1.7 If the remote operation of the appliance is via a telecommunication network, the relevant standard for the telecommunication interface circuitry in the appliance is EN 41003
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
N/A
N/A
N/A
N/A
N/A
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 90
Page 90 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Compliance with clause 8 of this standard is not
N/A impaired by connecting the appliance to a device covered by EN 41003
24.Z1 For motor running capacitors (IEC 60252-1 type P2)
N/A with a metallic enclosure having an overpressure fuse the flame testing of internal plastic parts supporting current carrying connections as required in 30.2.2 and 30.2.3.1 is not necessary
25.6 Supply cords of single-phase portable appliances having a rated current not exceeding 16 A, fitted with a plug complying with the following standard sheets of IEC/TR 60083:
- for class I appliances:
N/A
standard sheet C2b, C3b or C4 ............................ :
- for class II appliances:
N/A
standard sheet C5 or C6 ....................................... :
25.7 Rubber sheathed cords (60245 IEC 53) are not
N/A suitable for appliances intended to be used outdoors or when they are liable to be exposed to significant amount of ultraviolet radiation
Halogen-free thermoplastic compound sheathed supply cords have properties at
least those of:
- halogen-free thermoplastic compound
N/A
sheathed cords (H03Z1Z1H2-F or H03Z1Z1-F), for appliances having a mass not exceeding 3 kg
----
----
- halogen-free thermoplastic compound sheathed cords (H05Z1Z1H2-F or H05Z1Z1-F), for other appliances
Cross-linked halogen-free compound sheathed
supply cords have properties at least those of cross-linked halogen-free compound sheathed cords (H07ZZ-F)
26.11 Conductors connected by soldering are not
considered to be positioned or fixed so that reliance is not placed upon the soldering alone to maintain them in position unless they are held in place near the terminals independently of the solder
29.3.Z1 Appliance constructed so that if there is a possibility
of damaging the insulation during installation, the insulation withstands the scratch and penetration test of 21.2
32 Compliance regarding electromagnetic fields is
checked according to EN 62233
Annex I,
19.I.101
The appliance is supplied at rated voltage and operated under normal operation with each of the fault conditions specified
N/A
N/A
P
N/A
P
N/A
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 91
Page 91 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
The duration of the test is as specified in 19.7 N/A ZA ANNEX ZA (NORMATIVE)
----
SPECIAL NATIONAL CONDITIONS
Norway
19.5 The test is also applicable to appliances intended to
N/A
----
be permanently connected to fixed wiring
Norway
22.2 The second paragraph of this subclause, dealing
N/A
----
with single-phase, permanently connected class I appliances having heating elements, is not applicable due to the supply system
25.6 and
25.25
All CENELEC countries Information concerning National plug and
socket-outlets is available from the CENELEC
N/A
----
website. Normative national requirements concerning plug and socket-outlets are shown in the relevant National standard
Ireland and United Kingdom
----
25.8 In the table, the lines for 10 A and 16 A are replaced by: ----
> 10 and 13 1,25 N/A > 13 and 16 1,5 N/A
ZB ANNEX ZB (INFORMATIVE)
A-DEVIATIONS
Ireland
25.6 These regulations apply to all plugs for domestic
----
N/A use at a voltage of not less than 200 V and in general allow only plugs complying with I.S. 401:1997, or equivalent, to be fitted to domestic appliances
United Kingdom
----
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 92
Page 92 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
25.6 These regulations apply to all plugs for domestic
N/A use at a voltage of not less than 200 V and in general allow only plugs to BS 1363 to be fitted to domestic appliances. It also allows plugs to BS 4573 and EN 50075 to be fitted to shavers and toothbrushes
ZC
ANNEX ZC (NORMATIVE) NORMATIVE REFERENCES TO INTERNATIONAL PUBLICATIONS WITH THEIR
----
CORRESPONDING EUROPEAN PUBLICATIONS
A list of referenced documents in this standard P
ZD ANNEX ZD (INFORMATIVE)
----
IEC and CENELEC CODE DESIGNATIONS FOR FLEXIBLE CORDS
A table with IEC and CENELEC code designations
P for flexible cords
ZE ANNEX ZE (INFORMATIVE)
----
SPECIFIC ADDITIONAL REQUIREMENTS FOR APPLIANCES AND MACHINES INTENDED FOR COMMERCIAL USE
7.1 Business name and full address of the
N/A manufacturer and, where applicable, his authorized
representative ....................................................... :
Model or type reference ........................................ : N/A
Serial number, if any ............................................. : N/A
Production year N/A
Designation of the appliance ................................. : N/A
7.12 Instructions provided with the appliance so that the
N/A appliance can be used safely
The instructions contain at least the following information: ----
- the business name and full address of the
N/A manufacturer and, where applicable, his authorized representative
- model or type reference of the appliance as
N/A marked on the appliance itself, except for the serial number
- the designation of the appliance together with its
N/A explanation in case it is given by a combination of letters and/or numbers
- the general description of the appliance, when
N/A needed due to the complexity of the appliance
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 93
Page 93 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- specific precautions if required during installation,
N/A operation, adjusting, user maintenance, cleaning, repairing or moving
- when needed drawings, diagrams, descriptions and explanations necessary for the safe use and user maintenance of the appliance
- the possible reasonably foreseeable misuse and, whenever relevant, a warning against the effects it may have on the safe use of the appliance
The words “Original instructions” appear on the
language version(s) verified by the manufacturer or by the authorized representative
When a translation of the original instructions has
been provided by a person introducing the appliance on the market; the meaning of the sentence “Translation of the original instructions” appear in the relevant instructions delivered with the appliance
The instructions for maintenance/service to be done
by specialized personnel, mandated by the manufacturer or the authorized representative may be supplied in only one Community language which the specialized personnel understand
The instructions indicate the type and frequency of
inspections and maintenance required for safe operation including the preventive maintenance measures
N/A
N/A
N/A
N/A
N/A
N/A
7.12.ZE1 If needed for specific appliances, the following information to be given: ----
- on use, transportation, assembly, dismantling
N/A when out of service, testing or foreseeable breakdowns, if these operations have consequences on stability of the appliance in order to avoid overturning, falling or uncontrolled movements of the appliance or of its component parts
- on how to maintain adequate mechanical
N/A stability when in use, during transportation, assembly, dismantling, scrapping and any other action involving the appliance
- on the protective measures to be taken by the
N/A user, including, where appropriate, the personal protective equipment to be provided
- on the operating method to be followed in the
N/A event of accident or breakdown; if a blockage is likely to occur the operating method to safely unblock the appliance
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 94
Page 94 of 116 Report No.: 160421073GZU-003
The appliance continues to operate, without causing
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- on the specifications on the spare parts to be
N/A used, when these affect the health and safety of the operator
- on airborne noise emissions, determined and declared in accordance with the relevant Part 2, which includes:
- the A-weighted emission sound pressure
N/A level at workstations, where this exceeds
70 dB(A) ......................................................... ;
- where this level does not exceed 70 dB(A),
N/A this fact is indicated
- the peak C-weighted instantaneous sound
N/A pressure value at workstations, where this exceeds 63 Pa (130 dB in relation to 20 µPa) :
- the A-weighted sound power level emitted by
N/A the machinery, where the A-weighted emission sound pressure level at workstations exceeds
80 dB(A) ......................................................... :
7.12.ZE2 The instructions includes a warning to disconnect
N/A
the appliance from its power source during service and when replacing parts
If the removal of the plug is foreseen, it is clearly
N/A
indicated that the removal of the plug has to be such that an operator can check from any of the points to which he has access that the plug remains removed
----
If this is not possible, due to the construction of the
N/A
appliance or its installation, a disconnection with a locking system in the isolated position is provided
19.11.4.8
N/A
any hazard to the user, from the same point in its operating cycle at which the voltage fluctuation occurred, or
a manual operation is required to restart it N/A
20.1 Appliances and their components and fittings have
N/A
adequate mechanical stability during transportation, assembly, dismantling and any other action involving the appliance
20.2 Dangerous moving transmission parts safeguarded
N/A
either by design or guards
When guards are used, they are fixed guards,
N/A
interlocking movable guards or protective devices
Moving parts directly involved in the function of the appliance which cannot be made
----
completely inaccessible fitted with:
- fixed guards or interlocking movable guards
N/A
preventing access to those sections of the parts that are not used in the work, and
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 95
Page 95 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
- adjustable guards restricting access to those
N/A
sections of the moving parts where access is necessary
Interlocking movable guards used where frequent
access is required
21.1 Appliances and their components and fittings have adequate mechanical strength and is constructed to withstand such rough handling that may be expected in normal use, during transportation, assembly, dismantling, scrapping and any other action involving the appliance
22.ZE.1 For appliances provided with a seat, the seat gives adequate stability
The distance between the seat and the control
devices capable of being adapted to the operator
22.ZE.2 For appliances provided with separate devices for the start and the stop functions, the stop function is unambiguously identifiable and does always override the start function
For appliances provided with one device performing
the start and the stop function, the stop function is unambiguously identifiable and does always override the start function
22.ZE.3 Appliances designed in such a way that incorrect mounting is avoided, if this can lead to an unsafe situation
N/A
N/A
N/A
N/A
N/A
N/A
N/A
If this is not possible, information on the correct
N/A mounting is given directly on the part and/or the enclosure
22.ZE.4 Where the weight, size or shape prevents
N/A appliances from being moved manually, they are fitted with attachments for lifting gear, or
so designed that they can be fitted with such
N/A attachments, or
be shaped in such a way that standard lifting gear
N/A can easily be used
Appliances to be moved manually are constructed
N/A or equipped so that they can be moved easily and safely
22.ZE.5 The fixing systems of fixed guards which prevent
N/A access to dangerous moving transmission parts only removable with the use of tools
If such guards have to be removed by the user for
N/A routine cleaning or maintenance their fixing systems remain attached to the fixed guards or to the machine after removal
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 96
Page 96 of 116 Report No.: 160421073GZU-003
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
Where possible, guards are incapable of remaining
N/A in place without their fixings
This does not apply if, after removal of the screws,
N/A or if the component is incorrectly repositioned, the appliance becomes inoperative
Movable guards are interlocked N/A The interlocking devices prevent the start of
N/A hazardous appliance functions until the guards are fixed in their position, and give a stop command whenever they are no longer closed
Where it is possible for an operator to reach the danger zone before the risk due to
---­hazardous appliance functions has ceased, movable guards associated with a guard locking device in addition to an interlocking device that:
- prevents the start of hazardous appliance
N/A
functions until the guard is closed and locked, and
- keeps the guard closed and locked until the risk of
N/A injury from the hazardous appliance functions has ceased
Interlocking movable guards remain attached to the
N/A appliance when open, and
they are designed and constructed in such a way
N/A that they can be adjusted only by means of an intentional action
22.ZE.6 Interlocking movable guards designed in such a
N/A way that the absence or failure of one of their components prevents starting or stops the hazardous appliance functions
The guard is opened to the extent needed to cause
N/A the interlocking to operate and is then closed, the number of operations being defined in the specific
Part 2 .................................................................... :
After this test any defect that may be expected in
N/A normal use is applied to the interlock system, including interruption of the supply, only one defect being simulated at a time
After these tests the interlock system is fit for
N/A further use
22.ZE.7 Adjustable guards restricting access to areas of the moving parts strictly necessary
----
for the work are:
- adjustable manually or automatically, depending
N/A on the type of work involved, and
- readily adjustable without the use of tools N/A
22.ZE.8 In case of interruption, re-establishment after an
N/A interruption or fluctuation in whatever manner of the power supply, the appliance does not restart
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 97
Page 97 of 116 Report No.: 160421073GZU-003
Appliances fitted with means to isolate them from all
Modification 1: October 12, 2016
IEC 60335-2-98
Clause Requirement + Test Result - Remark Verdict
However, automatic restarting of the operation is
N/A allowed if the appliance may continue to operate, without causing any hazard to the user, from the same point in its operating cycle at which the voltage interruption or fluctuation occurred
22.ZE.9
N/A energy sources
Such isolators are clearly identified, and N/A they are capable of being locked if reconnection
N/A endanger persons
After the energy source is disconnected, it is
N/A possible to dissipate any energy remaining or stored in the circuits of the appliance without risk to persons
ZF ANNEX ZF (INFORMATIVE)
----
CRITERIA APPLIED FOR THE ALLOCATION OF PRODUCTS COVERED BY STANDARDS IN THE EN 60335 SERIES UNDER LVD OR MD
List of standards under CENELEC/TC61 with the
P allocation under the LVD (Low Voltage Directive) or
the MD (Machinery Directive) ............................... :
ZG ANNEX ZG (NORMATIVE)
----
UV APPLIANCES The following modifications to this standard apply to
N/A appliances having UV emitters
This annex is not applicable to appliances covered
N/A by the scopes of IEC 60335-2-27, IEC 60335-2-59 or IEC 60335-2-109
7.12.ZG The instructions for appliances incorporating UVC
N/A emitters include the substance of the following: WARNING — This appliance contains a UV emitter. Do not stare at the light source
32 For appliances incorporating UV emitters the
N/A manufacturer delivers a declaration providing evidence that the plastic material exposed to the radiation is UV resistant
ZZ ANNEX ZZ (INFORMATIVE)
----
COVERAGE OF ESSENTIAL REQUIREMENTS OF EC DIRECTIVES
Description of the relation between this European
standard and the LVD (Low Voltage Directive,
Low Voltage Directive
2014/35/EU
P
2006/95/EC) and the MD (Machinery Directive, 2006/42/EC)
TRF No. IEC60335_2_98E
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 98
Page 98 of 116 Report No. 160421073GZU-003
Photo documents: Photos of ES071-1AE:
Modification 1: October 12, 2016
Front view
Water level mark
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 99
Page 99 of 116 Report No. 160421073GZU-003
Modification 1: October 12, 2016
left side view (location of rating label)
Right side view
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Page 100
Page 100 of 116 Report No. 160421073GZU-003
Modification 1: October 12, 2016
Rear view (water inlet hole)
DC socket
Block E, No.7-2 Guang Dong Software Science Park, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, China
Intertek Testing Services Shenzhen Ltd. Guangzhou Branch
Tel: (86-20) 8213 9688 Fax: (86-20) 32057538
Loading...