• Antimicrobial coating on pad prevents the surface
growth and migration of bacteria, mold, fungus and
algae on the humidifier pad.
• Bold new look with blue and white styling.
• Proven technology used for high performance
humidification and enhanced comfort.
• Preassembled for quicker installation.
• Small footprint, light weight and reversible
components allow easy mounting on either warm air
supply or return air duct of any forced air furnace.
• Interior components designed for quick maintenance
and service.
APPLICATION
The Enviacaire Elite HE225A,B and HE265A,B Bypass Flowthrough Humidifiers use the warm air furnace blower to
provide humidification for the whole house.
• Includes easy-to-use humidity control that mounts on
the wall or duct for more flexible installation.
• Continuous flushing reduces the frequency of
maintenance in a hard water installation.
• AIRWATCH™ Indicator can be installed to remind
homeowner to change humidifier pad.
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1.Your local Home and Building Control Sales Office (check white pages of your phone directory).
2.Home and Building Control Customer Relations
Honeywell, 1985 Douglas Drive North, MN10-1461
Golden Valley, Minnesota 55422-4386 1-800-468-1502
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarbouorgh, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0244
2
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
1
9-1/8 (232)
1
2 (3
05)
13-9/16
(345)
Fig. 1. Dimensions of HE225A,B in in. (mm).
1
-7
/1
6 (152)
DIAMETER
6 (29
0
)
12-7/16
(316)
M14818
Standard:
Air Conditioning and Refrigeration Institute Tested:
Standard 610.
Bypass Flow-through Humidifier package includes
humidifier pad, mounting template, self-piercing saddle
valve, 24 Vac transformer, H1008A Automatic Humidity
Control with HumidiCalc™ Software.
Accessories:
Current Sensor Relay, part no. 32001754-001.
C7089H Outdoor Temperature Sensor.
H8908B Convertible Humidity Control.
H1008A Automatic Humidity Control with HumidiCalc+™
Software (software calculates dewpoint to prevent
moisture condensation).
HC22E Antimicrobial Humidifier Pad (HE225A,B only).
HC26E Antimicrobial Humidifier Pad (HE265 A,B only).
HumidiCalc+™ Humidifier Sizing Software (software
Mount the humidifier at least 3 in. (76 mm) above
the furnace jacket to allow adequate space for the
solenoid valve and drain line. Check that there is
adequate space above the humidifier to remove and
install the humidifier cover.
HIGHBOY
M12248C
NOTE: Be sure the water feed tube is not pinched or
kinked.
12. Hinge the cover in place and secure with the
thumbscrew located at the bottom of the cover.
WATER
FEED NOZZLE
HUMIDIFIER
PAD ASSEMBL Y
FRAME
COVER
SIDEWALL
2. Tape the template in position and trace around the
template.
3. Remove the template and carefully cut the rectangular
opening.
4. Disassemble the humidifier; remove the cover and take
out the humidifier pad assembly. See Fig. 4.
NOTE: Sidewalls are interchangeable for either left or
right by-pass installation. To change direction,
remove the screws holding each sidewall,
switch sidewall locations and reinstall the
screws.
5. Position the humidifier housing in the opening (be sure
it is level), so the locking tabs are in place on the lower
sheet metal edge of the opening.
6. Secure the humidifier housing to the opening at the top
and bottom using sheet metal screws.
7. Locate the other plenum and cut an opening for a 6 in.
(152 mm) collar.
8. Install the 6 in. (152 mm) collar.
NOTE: Be sure to install a duct damper for summer
shutoff on systems with air conditioning.
9. Install a 6 in. (152 mm) diameter duct from the collar to
the humidifier.
NOTE: Some installations require a 90° elbow
attachment to the collar.
10. Seal the duct connections with duct tape.
NOTE: To avoid sagging and stress on the humidifier,
add support when ducting is longer than
4 ft (120 cm).
HUMIDIFIER
HOUSING
BY-PASS SIDEWALL
WATER
FEED TUBE
M14672
Fig. 4. Humidifier components.
WIRING THE HUMIDIFIER
CAUTION
Hazardous Voltage.
Can cause personal injury or equipment damage.
• Disconnect the power supply before installing or
servicing.
• On multispeed blower applications, do not wire the
high voltage side of the transformer to the same
power source that services the furnace blower.
Premature transformer burnout may occur.
All wiring must comply with applicable local codes,
ordinances and regulations.
1. Mount the transformer in a convenient location.
2. Connect wires to the 120V side of the transformer.
3. Wire the humidifier solenoid valve, current sensing
relay, or sail switch, humidity control and transformer.
Refer to the humidity control installation instructions for
mounting and wiring information.
NOTE: Select models of fan centers include humidifier taps
so the current sensing relay or sail switch is not
needed.