Honeywell Enviracare Elite Bypass Flow-Through Humidifier B User Manual

whole-house air quality system
HE225A,B and HE265A,B
Bypass Flow-Through
Humidifier
PRODUCT DATA
FEATURES/BENEFITS
• Antimicrobial coating on pad prevents the surface growth and migration of bacteria, mold, fungus and algae on the humidifier pad.
• Bold new look with blue and white styling.
• Proven technology used for high performance humidification and enhanced comfort.
• Preassembled for quicker installation.
• Small footprint, light weight and reversible components allow easy mounting on either warm air supply or return air duct of any forced air furnace.
• Interior components designed for quick maintenance and service.
APPLICATION
The Enviacaire Elite HE225A,B and HE265A,B Bypass Flow­through Humidifiers use the warm air furnace blower to provide humidification for the whole house.
• Includes easy-to-use humidity control that mounts on the wall or duct for more flexible installation.
• Continuous flushing reduces the frequency of maintenance in a hard water installation.
• AIRWATCH™ Indicator can be installed to remind homeowner to change humidifier pad.
• Five-year warranty.
® U.S. Registered Trademark Copyright © 2000 Honeywell • All Rights Reserved
68-0244
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
SPECIFICATIONS
Capacity:
At 120°F (49°C) plenum temperature and 0.20 static
pressure drop across supply and return: HE225A,B: 12 gallons per day (gpd) or 46 liters per
day (lpd).
HE265A,B: 17 gallons per day (gpd) or 65 liters per
day (lpd).
Electrical Ratings:
24 Vac, 60 Hz, 0.5A.
Humidified Area:
See Table 1.
Table 1. Size Of Area That Can Be Humidified.
House Description Air Changes Per Hour Sq ft Sq m Sq ft Sq m
Loose Two 750 70 1,000 93
Average One 1,500 140 2,000 186
Tight One-half 3,000 280 4,000 372
Humidifier Pad Dimensions:
See Table 2.
Plenum Opening Dimensions (Height x Width):
See Table 3.
Summer Shut-off Damper Dimensions (Height x Width):
See Table 4.
Bypass Duct Opening (Diameter):
6 in. (152 mm).
Drain Connection:
1/2 in. (13 mm) I.D. plastic hose connected directly to drain fitting on unit.
Dimensions:
Refer to Fig. 1 and 2.
HE225 Area (Up To) HE265 Area (Up To)
Table 2. Dimensions Of Humidifier Pads In In. (mm).
Model Height Width Depth
HE225 9-13/16 (249) 9-1/2 (241) 1-1/2 (38) HE265 13 (330) 10 (254) 1-1/2 (38)
Table 3. Dimensions Of Plenum Opening In In. (mm).
Model Height Width
HE225 9-7/16 (241) 9-5/16 (238) HE265 12-5/8 (321) 9-3/4 (248)
Table 4. Dimensions Of Summer Shut-off Damper
In In. (mm).
Model Height Width
HE225 9-3/16 (234) 8-7/8 (226) HE265 12-3/8 (314) 9-5/16 (236)
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Relations Honeywell, 1985 Douglas Drive North, MN10-1461 Golden Valley, Minnesota 55422-4386 1-800-468-1502
In CanadaHoneywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarbouorgh, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0244
2
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
1
9-1/8 (232)
1
2 (3
05)
13-9/16
(345)
Fig. 1. Dimensions of HE225A,B in in. (mm).
1
-7
/1
6 (152)
DIAMETER
6 (29
0
)
12-7/16
(316)
M14818
Standard:
Air Conditioning and Refrigeration Institute Tested: Standard 610.
Models:
HE225A TRADELINE® and HE265A TRADELINE®
Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H8908B Convertible Humidity Control.
HE225B TRADELINE® and HE265B TRADELINE®
Bypass Flow-through Humidifier package includes humidifier pad, mounting template, self-piercing saddle valve, 24 Vac transformer, H1008A Automatic Humidity Control with HumidiCalc™ Software.
Accessories:
Current Sensor Relay, part no. 32001754-001. C7089H Outdoor Temperature Sensor. H8908B Convertible Humidity Control. H1008A Automatic Humidity Control with HumidiCalc+™
Software (software calculates dewpoint to prevent
moisture condensation). HC22E Antimicrobial Humidifier Pad (HE225A,B only). HC26E Antimicrobial Humidifier Pad (HE265 A,B only). HumidiCalc+™ Humidifier Sizing Software (software
calculates required humidifier capacity for application). PC8900 Control. S688 Sail Switch.
9-1/4 (235)
13-9/16 (345)
16-3/4
(425)
12 (305)
6 (152)
DIAMETER
Fig. 2. Dimensions of HE265A,B in in. (mm).
15-5/16
(390)
M14819
INSTALLATION
WARNING
Hazardous Voltage. Can cause personal injury or equipment damage.
Do not cut or drill into any air conditioning line or electrical accessory.
CAUTION
Freezing Water, Flooding or Static Pressure Hazard. Can cause water damage to home or permanent equipment damage.
• The humidifier must be located where the ambient
temperature is above 32°F and below 160°F (0°C and 71°C).
• Be sure supply plenum static pressure is no greater than 0.3 in. w.c. and water pressure is no greater than 125 psi.
IMPORTANT
To assure optimal product performance, be sure the template is level before marking location.
1. Determine the best location for the humidifier and draw a level line on the plenum. See Fig. 3.
Approvals:
Underwriters Laboratories Inc. Listing: 56 BL. Canadian Underwriters Laboratories Inc. Listing: 56 BL.
3
68-0244
HE225A,B AND HE265A,B BYPASS FLOW-THROUGH HUMIDIFIER
11. Reinstall the humidifier pad assembly in the humidifier housing.
HORIZONTAL
DOWN
FLO
LOWBOY
Fig. 3. Typical humidifier installation locations.
IMPORTANT
Mount the humidifier at least 3 in. (76 mm) above the furnace jacket to allow adequate space for the solenoid valve and drain line. Check that there is adequate space above the humidifier to remove and install the humidifier cover.
HIGHBOY
M12248C
NOTE: Be sure the water feed tube is not pinched or
kinked.
12. Hinge the cover in place and secure with the thumbscrew located at the bottom of the cover.
WATER FEED NOZZLE
HUMIDIFIER PAD ASSEMBL Y
FRAME
COVER
SIDEWALL
2. Tape the template in position and trace around the template.
3. Remove the template and carefully cut the rectangular opening.
4. Disassemble the humidifier; remove the cover and take out the humidifier pad assembly. See Fig. 4.
NOTE: Sidewalls are interchangeable for either left or
right by-pass installation. To change direction, remove the screws holding each sidewall, switch sidewall locations and reinstall the screws.
5. Position the humidifier housing in the opening (be sure it is level), so the locking tabs are in place on the lower sheet metal edge of the opening.
6. Secure the humidifier housing to the opening at the top and bottom using sheet metal screws.
7. Locate the other plenum and cut an opening for a 6 in. (152 mm) collar.
8. Install the 6 in. (152 mm) collar.
NOTE: Be sure to install a duct damper for summer
shutoff on systems with air conditioning.
9. Install a 6 in. (152 mm) diameter duct from the collar to the humidifier.
NOTE: Some installations require a 90° elbow
attachment to the collar.
10. Seal the duct connections with duct tape.
NOTE: To avoid sagging and stress on the humidifier,
add support when ducting is longer than 4 ft (120 cm).
HUMIDIFIER HOUSING
BY-PASS SIDEWALL
WATER FEED TUBE
M14672
Fig. 4. Humidifier components.
WIRING THE HUMIDIFIER
CAUTION
Hazardous Voltage. Can cause personal injury or equipment damage.
• Disconnect the power supply before installing or servicing.
• On multispeed blower applications, do not wire the high voltage side of the transformer to the same power source that services the furnace blower. Premature transformer burnout may occur.
All wiring must comply with applicable local codes, ordinances and regulations.
1. Mount the transformer in a convenient location.
2. Connect wires to the 120V side of the transformer.
3. Wire the humidifier solenoid valve, current sensing
relay, or sail switch, humidity control and transformer. Refer to the humidity control installation instructions for mounting and wiring information.
NOTE: Select models of fan centers include humidifier taps
so the current sensing relay or sail switch is not needed.
68-0244
4