Access Control System is a mass-produced product. It strictly
tested comply with the standard of China, U.S.A, and EU. This
file contains important information. It is better for you to read it
carefully prior to use. If you ignore it, the incorrect installation may
cause the unit damage. Although we could do our best to offer
you service, the neglect to the file could cause unwanted cost for
you.
1. Before installation, please make sure the power is cut off,
because it is very dangerous if the power is on. The short circuit of
power cable may cause the core parts damage.
2. All exposed part of connection wire end cannot be exceeded
5mm to prevent the bared wire accidental connection which leads
to machine break down. And also suggest using different color
cable to connect.
3. In the place where the static is strong or in winter, please
connect the grounding firstly, in order to prevent the instant mass
static damage the machine.
4. Connect power supply with device in the last for the wiring
connection. If you find any unusual thing occur, please firstly cut
off the power, then go to examine. Keep in mind: wiring operation
- - 1
Fingerprint T&A Access Control System User Guide
under power on will lead to machine sudden damage; we are not
liable for damages and trouble due to such operation.
5. The height to mount device is about 1.4-1.5 meter
6. After installation, please take off protection film on the fingerprint
sensor to get best recognize result.
7. After installation finish, when go to test the exit-door button,
please keep a personal in the outside, because sometimes the
accidental issue can bring on you are not able to go outside.
8. Our equipment offer an automatically function, please after the
installing finish. Run the auto-test function to confirm the installation
finish.
9.We recommend using above the 12V/3A direct-current supply
for Honeywell VISTA series access control device, electricity lock
better to powered by 12VDC, and no more than 1.5 A electric
current At this time, the electric current of supply should be
above1A than lock power. If the parameter of lock power
surpasses this scope, please connect technical personnel. If the
power had not met above requests, it possibly causes to be
unable normally to drive the electricity lock, even damage the
device.
10. Before device to be connected please read and always follow
"Quick connect Guide" closely. Because the wrong wiring will
cause the core block and sensor to burn out, insult in device to
break down, at this cause Honeywell is not liable for any damages
and trouble.
- - 2
Fingerprint T&A Access Control System User Guide
11. If the space between power adapters and device is too long,
please do not use the twisted-pair or other type ferrules for the
power wire. When the power wire is choused, you should consider
attenuation of voltage, which has passed long distance transfer.
12. Please use specialized RS485 cable and the RS232/485
converter with power to hookup the network, the bus structure
apply to connect with each device. When a long cable is used to
transfer signal, it is need to connect a matching resistance to
receiver, and its value is 120Ώ.
13. Other more details items; please see also the user manual, the
operating instructions and the appendix and so on.
- - 3
Fingerprint T&A Access Control System User Guide
2 System Configuration
2.1 The illustration of system construction
- - 4
Fingerprint T&A Access Control System User Guide
2.2
The sketch map of communication
1, Access Control System directly connects with PC through
RS232 or TCP/IP
2, Access Control System connects with PC through RS485
network
3, Access Control System connects with PC through TCP/IP
network.
- - 5
Fingerprint T&A Access Control System User Guide
3. Installation
3.1 Fixing mounting plate
①
Take out a Access Control System,dismantle the screw
between machine body and mounting plate until it is out, see
figure (1).
②
Carefully take up the bottom of mounting plate, see figure (2),
push it up, see figure (3), then take away the mounting plate.
③
Determine the position of mounting plate on the wall. The
Access Control System should be mounted on the external wall of
the door approximately 1400mm from the ground to the unit
bottom. After the position is determined, you could drill a hole
(18mm*20mm) for cable out, see below figure shadowed part.
④
Make the hole of mounting plate meet the drilled hole on the
wall, Use the screw to fix it on the wall, (for the details please see
following figure)
⑤
after installation, please make sure the mounting plate is
reliable, fasten, not loosed.
- - 6
Fingerprint T&A Access Control System User Guide
3.2 Connect with peripheral equipment
Caution: Do not to connect peripheral equipment before the
power of the device is cut down, otherwise it is possible to
damage the device badly.
Please follow instruction to connect peripheral equipment
1) Door sensor connection(sensor, GND)
2) Exit-button connection(Button GND)
3) Alarm connection(Alarm+, Alarm-)
4) Door lock connection(NC, COM, NO )
5) Ethernet connection
6) RS232 connection
7) RS485 connection
8) Wiegand output connection
9) Cable Bell (
Bell+, Bell-)
10) Power connection (
(
RJ45-1, RJ45-2, RJ45-3,RJ45-4
(
232RX, 232TX, GND
(
485A,485B
)
(
WD0,WD1,GND
)
GND, +12V)
)
)
Cable socket
- - 7
Loading...
+ 21 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.