This document describes Honeywell VISTA Serials Access
Control System installation user guide & wiring instruction.
About this Guide
The Honeywell VISTA Serials Access Control System
User guide is designed to provide information to install
the CA-FP-100F & CA-FP-100FS serial Access Control
System, for operation and configuration, please refer to
the corresponding user’s manual.
Not all function these guides introduce available in
combination, all is option.
About your machine function, please consult our
company technical personnel or the sales personnel.
Information in this document is subject to change without notice.
Content Introduced
Contents
1 Before Installing .......................................................................... 1
1.1 Notice about installing ...................................................... 1
2 System Configuration ................................................................. 4
2.1 The illustration of system construction ............................ 4
2.2 The sketch map of communication .................................. 5
3.Installation .................................................................................. 6
3.1 Fixing mounting plate ....................................................... 6
3.2 Connect with peripheral equipment ................................. 7
3.2.1 Door Sensor ........................................................... 9
3.2.2 Release Button ...................................................... 9
3.2.3 Alarm ...................................................................... 9
3.2.4 Conntion with lock ............................................... 10
3.2.5 Ethernet connection ............................................. 16
3.2.6 Connection with RS232 ....................................... 18
3.2.7 Connection with RS485 ....................................... 19
3.2.8 Wiegand output.................................................... 21
3.2.9 Power connection ................................................ 22
3.2.10 Connect with external Wiegand reader ............. 22
3.3 Fixing Access Control System ....................................... 23
4. Fastening Access Control System .......................................... 24
5. Others ...................................................................................... 25
5.1 Reset .............................................................................. 25
5.2 Anti-dismantle button ..................................................... 25
5.3 Cable doorbell ................................................................ 26
Fingerprint T&A Access Control System User Guide
1 Before Installing
1.1 Notice about installing
Access Control System is a mass-produced product. It strictly tested comply with the standard of China, U.S.A, and EU. This file contains important information. It is better for you to read it carefully prior to use. If you ignore it, the incorrect installation may cause the unit damage. Although we could do our best to offer you service, the neglect to the file could cause unwanted cost for you.
1. Before installation, please make sure the power is cut off, because it is very dangerous if the power is on. The short circuit of power cable may cause the core parts damage.
2. All exposed part of connection wire end cannot be exceeded 5mm to prevent the bared wire accidental connection which leads to machine break down. And also suggest using different color cable to connect.
3. In the place where the static is strong or in winter, please connect the grounding firstly, in order to prevent the instant mass static damage the machine.
4. Connect power supply with device in the last for the wiring connection. If you find any unusual thing occur, please firstly cut off the power, then go to examine. Keep in mind: wiring operation
- - 1
Fingerprint T&A Access Control System User Guide
under power on will lead to machine sudden damage; we are not liable for damages and trouble due to such operation.
5. The height to mount device is about 1.4-1.5 meter
6. After installation, please take off protection film on the fingerprint sensor to get best recognize result.
7. After installation finish, when go to test the exit-door button, please keep a personal in the outside, because sometimes the accidental issue can bring on you are not able to go outside.
8. Our equipment offer an automatically function, please after the installing finish. Run the auto-test function to confirm the installation finish.
9.We recommend using above the 12V/3A direct-current supply for Honeywell VISTA series access control device, electricity lock better to powered by 12VDC, and no more than 1.5 A electric current At this time, the electric current of supply should be above1A than lock power. If the parameter of lock power surpasses this scope, please connect technical personnel. If the power had not met above requests, it possibly causes to be unable normally to drive the electricity lock, even damage the device.
10. Before device to be connected please read and always follow "Quick connect Guide" closely. Because the wrong wiring will cause the core block and sensor to burn out, insult in device to break down, at this cause Honeywell is not liable for any damages and trouble.
- - 2
Fingerprint T&A Access Control System User Guide
11. If the space between power adapters and device is too long, please do not use the twisted-pair or other type ferrules for the power wire. When the power wire is choused, you should consider attenuation of voltage, which has passed long distance transfer.
12. Please use specialized RS485 cable and the RS232/485 converter with power to hookup the network, the bus structure apply to connect with each device. When a long cable is used to transfer signal, it is need to connect a matching resistance to receiver, and its value is 120Ώ.
13. Other more details items; please see also the user manual, the operating instructions and the appendix and so on.
- - 3
Fingerprint T&A Access Control System User Guide
2 System Configuration
2.1 The illustration of system construction
- - 4
Fingerprint T&A Access Control System User Guide
2.2
The sketch map of communication
1, Access Control System directly connects with PC through RS232 or TCP/IP
2, Access Control System connects with PC through RS485 network
3, Access Control System connects with PC through TCP/IP
network
- - 5
Fingerprint T&A Access Control System User Guide
3. Installation
3.1 Fixing mounting plate
Take out a Access Control Systemdismantle the screw between machine body and mounting plate until it is out, see figure (1).
Carefully take up the bottom of mounting plate, see figure (2), push it up, see figure (3), then take away the mounting plate.
Determine the position of mounting plate on the wall. The Access Control System should be mounted on the external wall of the door approximately 1400mm from the ground to the unit bottom. After the position is determined, you could drill a hole (18mm*20mm) for cable out, see below figure shadowed part.
Make the hole of mounting plate meet the drilled hole on the wall, Use the screw to fix it on the wall, (for the details please see following figure)
after installation, please make sure the mounting plate is reliable, fasten, not loosed.
- - 6
Fingerprint T&A Access Control System User Guide
3.2 Connect with peripheral equipment
Caution: Do not to connect peripheral equipment before the power of the device is cut down, otherwise it is possible to damage the device badly.
Please follow instruction to connect peripheral equipment
1) Door sensor connectionsensor, GND
2) Exit-button connectionButton GND
3) Alarm connectionAlarm+, Alarm-
4) Door lock connectionNC, COM, NO
5) Ethernet connection
6) RS232 connection
7) RS485 connection
8) Wiegand output connection
9) Cable Bell (
Bell+, Bell-)
10) Power connection (
RJ45-1, RJ45-2, RJ45-3,RJ45-4
232RX, 232TX, GND
485A,485B
WD0,WD1,GND
GND, +12V)
Cable socket
- - 7