Honeywell C7600B, H7655A Product Data

C7600B, H7655A
Solid State Humidity Sensors
PRODUCT DATA
FEATURES
• Long-lasting solid state sensing element is accurate and stable over time.
• Enclosed in rugged, wall-mounted plastic case.
• Vents on top and sides of cover allow air flow to humidity sensing element.
• Compact size and lightweight construction provide easy mounting.
• C7600B provides 2-10 Vdc output directly proportional to relative humidity and can be used with the H775 Humidity Controller.
• H7655A provides 0-10 Vdc output directly proportional to relative humidity and can be used with the T7350 Temperature/Humidity Controller.
APPLICATION
SPECIFICATIONS
IMPORTANT
The specifications given in this publication do not include normal manufacturing tolerances. Therefore, an individual unit may not exactly match the listed specifications. Also, this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed.
Models: C7600B, H7655A Solid State Humidity Sensors.
Provide a dc voltage output in direct proportion to the change in relative humidity.
Dimensions: See Fig. 1.
Case: Rugged, lightweight, compact plastic, easy to install.
Electrical Ratings:
Input: 16-40 Vdc or 16-30 Vac. Output:
C7600B: 2-10 Vdc voltage signal; increases from 2 to 10
Vdc as humidity increases. Output voltage is directly proportional to relative humidity increase. See Fig. 2.
H7665A: 0-10 Vdc voltage signal; increases from 0 to 10
Vdc as humidity increases. Output voltage is directly proportional to relative humidity increase. See Fig. 3.
Maximum Power Consumption: 0.3 VA.
Mounting: Wall mount (directly to wall or standard outlet box).
Ambient Temperature Ranges:
Operating: 32°F to 125°F (0°C to 52°C). Shipping: -40°F to +150°F (-40°C to +66°C).
® U.S. Registered Trademark © 2004 Honeywell International Inc. All Rights Reserved
63-2166—8
C7600B, H7655A SOLID STATE HUMIDITY SENSORS
SPECIFICATIONS (continued from page 1)
Humidity Range: 10 to 90 percent RH, noncondensing.
Humidity Accuracy:
From 30 to 70% RH: ±5 percent RH. From 10 to 90% RH: ±7 percent RH.
1-13/16 (46)
3-1/4
(83)
4-5/8 (117)
3-13/16
(97)
10
9
8
7
6
5
4
VOLTAGE OUTPUT (VDC)
3
2
0
20
HUMIDITY IN PERCENT RH
40
NOMINAL
80
60
Fig. 2. C7600B nominal output voltage
vs. relative humidity.
% RH
100
Vdc
10
2.8
20
3.6
30
4.4
40
5.2
50
6.0
60
6.8
70
7.6
80
8.4
90
9.2
M8810A
7/8 (22)
1-1/16 (27)
3/8
(10)
2-7/8 (73)
3-5/8 (92)
M17720
Fig. 1. C7600B, H7665A dimensions in in. (mm).
10
9
8
7
6
5
4
VOLTAGE OUTPUT (VDC)
3
2
1
0
0
20
HUMIDITY IN PERCENT RH
40
NOMINAL
80
60
Fig. 3. H7655A nominal output voltage
vs. relative humidity.
100
% RH
0 10 20 30 40 50 60 70 80 90
100
Vdc
0 1 2 3 4 5 6 7 8 9
10
M22589
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:
1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory).
2. Honeywell Customer Care
1885 Douglas Drive North
Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
63-2166—8 2
C7600B, H7655A SOLID STATE HUMIDITY SENSORS
INSTALLATION
When Installing this Product...
1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition.
2. Check ratings given in instructions and on the product to ensure the product is suitable for your application.
3. Installer must be a trained, experienced service technician.
CAUTION
Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry.
Disconnect power supply before installation.
Location
The sensor cay be installed directly on a wall or standard wall outlet box.
The sensor should be located away from traffic areas, on an inside wall, at least 3 ft (1m) from an outside wall and 54 in. (1.4m) from the floor.
Mounting
1. Loosen the cover locking screw and remove the cover.
2. Run wire to the selected location; thread wire through
the semicircular hole in the wallplate; and make connections to the sensor (see the Wiring section).
3. Four mounting screws are provided, two self-tapping type for wall mounting and two for outlet box mounting. Select the proper screws for the application.
4. If air drafts occur through the wall opening, eliminate with suitable material.
5. Fasten the sensor on the wall or outlet box with screws through the wallplate mounting holes. See Fig. 4.
6. Replace the cover and tighten the cover locking screw.
WALLPLATE
MOUNTING SCREW (2)
MOUNTING TAB (2 INSIDE COVER)
OUTLET BOX
Operation
C7600B
The sensor provides a 2 to 10 Vdc output signal directly proportional to the humidity of the air where the unit is mounted.
H7665A
The sensor provides a 0 to 10 Vdc output signal directly proportional to the humidity of the air where the unit is mounted.
WIRING
CAUTION
Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry.
Disconnect power supply before installation.
IMPORTANT
All wiring must agree with applicable codes, ordinances and regulations.
See Fig. 5 through 9 for wiring details. Wire input power (16 to 40 Vdc or 16 to 30 Vac) to V+ and GND terminals. Connect sensor output (OUT) and GND to a controller analog input as shown in Fig. 5 through 9.
HUMIDITY SENSOR
~V+
GND
OUT
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
Fig. 5. C7600B, H7655A typical wiring.
CONTROLLER
ANALOG INPUT
SIG
GND
24 Vac
+ –
L1
L2
120 Vac
1
M2025E
THERMOSTAT
Fig. 4. Mounting the sensor on an outlet box.
MOUNTING TAB SLOT (2)
COVER LOCKING SCREW
M17719
C7600B
-V+
OUT
GND
L1
120 Vac
24 Vac
1 POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
L2
1
W7620 (W7600)
V1 (ANALOG INPUT) COMM
M8809B
Fig. 6. C7600B wiring to W7620.
3 63-2166—8
C7600B, H7655A SOLID STATE HUMIDITY SENSORS
C7600B
-V+
OUT
GND
123
24 Vac
H775A HUMIDITY
1
L2
L1
1
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
CONTROLLER
Fig. 7. C7600B wiring to H775A.
T7770 REMOTE SENSOR
T7350 SUBBASE
1
T5 T6 T7 T4
L2
2
L1 (HOT)
HS
Vo
(0-10 Vdc)
HUMIDITY SENSOR
456
Gnd Vin
24 Vac
5
123456789
T3
(Vac)
M5232B
OUTDOOR AIR SENSOR
OSOS ASAS
M
MHC HP
MOTION SENSOR
H775B -E HUMIDITY CONTROLLER
C7600B
-V+
OUT
GND
45 67
1
L1 L2
1
24 Vac
C7600C
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
+
-
123
Fig. 8. C7600B wiring to H775B-E in two-sensor system
with C7600C.
HEAT RELAY 2
DISCHARGE AIR SENSOR
COMPRESSOR CONTACTOR 4
W3/Y4 Y3 W2
RCX
AUXRH
3
4
ECONOMIZER
HEAT RELAY 1
COMPRESSOR CONTACTOR 2
W1 G
Y1
FAN RELAY
COMPRESSOR CONTACTOR 1
Y2
COMPRESSOR CONTACTOR 3
24 Vac
8
M5231B
POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
1
ENSURE TRANSFORMER IS SIZED TO HANDLE THE LOAD.
2
3
HEAT/COOL SYSTEMS WITH ONE TRANSFORMER REQUIRE THE FACTORY-INSTALLED JUMPER.
4
USE ECONOMIZER INSTRUCTIONS FOR INSTALLATION DIRECTIONS.
5
HC AND HP PROVIDE 24 VAC TO THE HUMIDITY SENSOR.
Fig. 9. Humidity Sensor (0-10 Vdc output) wiring with T7350
(use with RH/Temperature combination T7350 units only).
Automation and Control Solutions
Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario
63-2166—8 B.B. Rev. 11-04 www.honeywell.com
M1V 4Z9
M22529
By using this Honeywell literature, you agree that Honeywell will have no liability for any damages arising out of your use or modification to, the literature. You will defend and indemnify Honeywell, its affiliates and subsidiaries, from and against any liability, cost, or damages, including attorneys’ fees, arising out of, or resulting from, any modification to the literature by you.