Honeywell C645A-E User Manual

60-2159-8
C645A,B,D,E
C645A,B with Window
C645C
GENERAL
The C645 pressure switches are safety devices used in positive-pressure or differential-pressure systems to sense gas or air pressure changes.
C645A-E
Pressure Switches
PRODUCT DATA
FEATURES
• C645A,B models are for use on natural gas, LP gas, or air.
• C645B1047 includes a scaleplate stop to meet American Gas Association (AGA) requirements for gas-fired boilers with inputs over 2-1/2 million Btuh.
• C645C,D models are for use on air only.
• C645E for use with distillate fuel oil.
• Spring-loaded diaphragm actuates snap-acting Micro Switch.
• Switch can be wired to turn on alarm.
• C645A,C and D models break control circuit on pressure fall.
• C645B models break control circuit on pressure rise.
• Lockout and manual reset optional in A and C models.
• Removable, zinc-plated cover protects scaleplate and adjusting screw.
• Lockout models have external manual reset lever.
• Pipe tappings allow selection of positive pressure, differential-pressure, or venting connections.
• Optional switch position indicator available.
• Models of C645A,B available with cover window for setpoint visibility.
• Buna-N fiber-reinforced material for increased control diaphragm strength.
• Two seal-off diaphragms for added reliability.
Copyright © 1995 Honeywell Inc. • All Rights Reserved
Contents
General ............................................................................... 1
Features .............................................................................. 1
Specifications ...................................................................... 2
Ordering Information ........................................................... 2
Installation ........................................................................... 4
Settings and Adjustments ................................................... 6
Operation and Checkout ..................................................... 7
C645A-E PRESSURE SWITCHES
SPECIFICATIONS
Models:
C645A,C,D Pressure Switchesbreak a circuit when
pressure falls to scale setting minus the differential. Refer to Table 1.
C645B Pressure Switchesbreak a circuit when pressure
rises to scale setting. Refer to Table 1.
C645Ebreaks circuit when pressure falls to scale setting
minus the differential. Refer to Table 1.
Table 1. Pressure switch model selection.
Differential
Scale
Models (in. wc) (kPa) Gas Air Action Indicator
C645A 3 to 21 0.7 to
C645B 3 to 21 0.7 to
C645C 0.6 to
C645D 3 to 21 0.7 to
C645E 3 to 21 0.7 to
a
Locks out when pressure falls to setpoint minus differential; can be reset manually after pressure rises to setpoint.
b
Locks out when pressure rises to setpoint; can be manually reset after pressure falls to setpoint minus differential.
c
Without indicator on Auto Recycle; with indicator on Lockout model.
d
With surge orifice.
Range
5 to 35 1.2 to
5 to 35 1.2 to
5.3 2 to 20d0.5 to 5 No Yes Auto Recycle No 1 3 0.2 0.7 5 34.5 No
Scale
Range
5.2
8.7
5.2
8.7
0.1 to
1.3
5.2
5.2
Natural
or LP
Yes Yes Auto Recycle
Yes Yes
Yes Yes Lockout
Yes Yes Yes 1 4 0.2 1.0 5 34.5 Yes
No Yes Auto Recycle
No Yes Auto Recycle No 1 3 0.2 0.7 5 34.5 No
No Yes Auto Recycle No 1 3 0.2 0.7 5 34.5 No
Switching
or Lockout
b
or Lockout
Switch
Position
Optional 1 3 0.2 0.7 5 34.5 Optional
a
c
Yes 1 3 0.2 0.7 5 34.5 Optional
Optional 0.2 0.8 0.05 0.02 1.5 10.3 No
a
Range
(in. wc)
Nom. Max. Nom. Max.
1 4 0.2 1.0 5 34.5 Yes
Differential
Range
(kPa)
Maximum
Surge
Pressure
(psi) (kPa) Window
Maximum
Pressure Cover
Surge
Switch Ratings (Amperes):
Model 120 Vac 240 Vac
C645A Full Load 7.4 3.7 C645B Locked Rotor 44.4 22.2 C645D C645C Full Load 8.0 5.1
Alternate Electrical Ratings when used with Honeywell Flame Safeguard Programmers (all C645 models):
Ignition
540 VA
Transformer Pilot Valve 50 Main Valve 250 VA with 10 times inrush.
400 VA with 2-1/2 times inrush.
Locked Rotor 48.0 30.6
C645E Full Load 7.4 3.7
Locked Rotor 44.4 22.2
All models also rated 2A at 30 Vac.
ORDERING INFORMATION
When purchasing replacement and modernization products from your TRADELINE® wholesaler or your distributor, refer to the TRADELINE® catalog or price sheets for complete ordering number, or specify
1. Order number. 3. Optional specifications.
2. Air or gas control on C645A,B models. 4. Accessories, if desired.
If you have additional questions, need further information, or would like to comment on our products or services please write or phone:
1. Your local Honeywell Home and Building Control Sales Office (check white pages of your phone directory).
2. Honeywell Home and Building Control Customer Relations Honeywell, 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386
In CanadaHoneywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. International sales and service offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
60-2159—8
2
C645A-E PRESSURE SWITCHES
Switching:
Spdt Micro Switch snap-acting switch (Fig. 3).
Minimum Ambient Temperature:
-20°F (- 29°C).
Maximum Ambient Temperature:
125°F (52°C).
Connections:
1/4-18 NPT female tapping for main or high pressure
connection.
1/8-27 NPT female tapping for venting or low-pressure
connection.
Approvals:
Underwriters Laboratories Inc. listed: C645AE File
no. MP2168, Guide no. MFHX; for use in ambient temperatures normally prevailing in occupiable spaces, which usually are not higher than 77°F (25°C) but can occasionally be as high as 104°F (40°C) for brief periods.
2-7/8 (73)
Canadian Standards Association listed: C645A-E, File no.
LR1620-369, Guide no. 140-A-2; for use subject to same ambient temperature restrictions as Underwriters
Laboratories Inc. Factory Mutual Approved. Industrial Risk Insurers: C645A-D models with window in
cover approvable for applications on burners over
5 million Btuh (5 thousand cfh) input.
Optional Specifications:
1. C645A with position indicator and manual reset.
2. C645A operation to 1.5 in. WC with position indicator
and manual reset.
3. C645B with position indicator and manual reset.
4. C645C with position indicator and manual reset.
5. C645D with 2 in. (50.8 mm) differential.
Accessories:
1. C645A,B,D: Mounting Bracket: part no. 15865AC.
2. C645C: Mounting Bracket: part no. 112657A.
3. C645A: Cover with Window: part no. 137637B.
4. C645B: Cover with Window: part no. 137637C.
3-1/2 (88.9)
MOUNTING BRACKET (OPTIONAL)
4
3-1/2 (88.9)
3/8 (9.5)
1
IMPORTANT: FOR MODELS WITH LOCKOUT, DO NOT OBSTRUCT MANUAL RESET LEVER.
1-1/8 (28.6)
(101.6)
Fig. 1. Dimensions of C645A,B,D, and E in in. (mm).
4-3/4 (120.6)
1
2-1/2 (63.5)
1-5/16 (33.3)
5/8 (15.9)
3/16 (2) (4.8)
1/4-18 NPT
1/8-27 NPT
3/8 (9.5)
M7564
3
60-2159—8
C645A-E PRESSURE SWITCHES
MOUNTING BRACKET (OPTIONAL)
5/16 (7.9)
1-1/8 (29)
MANUAL RESET LEVER
3-7/8 (98.4)
1/4-18 INCH NPT
1 (25.4)
2-1/4 (57.1)
3/4 (19)
2-3/4 (69.8)
5 (127)
3-5/8 (92)
3/16 (4.8) DIA.
1-13/16 (46)
9/32 (7.1) DIA. (2)
1
IMPORTANT: FOR MODELS WITH LOCKOUT, DO NOT OBSTRUCT MANUAL RESET LEVER.
Fig. 2. Dimensions of C645C in in. (mm).
INSTALLATION
When Installing this Product . . .
Read these instructions carefully. Failure to follow them
could damage the product or cause a hazardous condition.
Check the ratings given in the instructions and on the
product to make sure the product is suitable for your application.
Installer must be a trained, experienced service
technician.
After installation is complete, check out product
operation as provided in these instructions.
CAUTION
Disconnect power supply before beginning installation to prevent electrical shock or equipment damage.
3/4 (19)
2-5/8 (66.7)
1-1/4 (31.7)
1
3 (76.2)
1/8-27 INCH NPT
7-7/8 DIA. (200)
M7563
Mounting
The C645 has a hexagonal fitting with a 1/4 in. NPT tapping, which is the high pressure connection in differential applications. The bleed fitting is 1/8 in. NPT female tapped. In differential pressure control applications using air, connect the lower pressure to the bleed fitting (Fig. 3 and 4). In applications using combustible gases, vent the bleed tapping according to applicable standard code or jurisdictional authority.
The C645A,B,D can be mounted in any position but are more accurate when mounted horizontally. The C645C is mounted with the diaphragm vertical and the bleed fitting at the bottom.
60-2159—8
4
C645A-E PRESSURE SWITCHES
1
1
2
2
W
B
R
C645A,C,D BREAKS R-W, MAKE R-B ON PRESSURE FALL. MANUAL RESET MODELS LOCK OUT.
C645B BREAKS R-B, MAKES R-W ON PRESSURE RISE AND LOCKS OUT.
M7565
The C645E1002 Distillate Fuel Oil Pressure Switch is the same as the C645A1006 Gas Pressure Switch except that it does not have a 0.015 in. (0.38 mm) diameter (nominal) orifice in its 1/4 in. NPT main (high pressure) connection. (This orifice is required in a C645A Gas Pressure Switch to restrict gas leakage, but it is too small for oil applications.) The C645E1002 has a 0.125 in. (3.18 mm) diameter (nominal) opening in its 1/4 in. NPT main connection into its pressure chamber.
CAUTION
Vent the bleed tapping back to the oil supply tank not to the combustion chamber.
Wiring
Disconnect power supply before connecting wiring to prevent electrical shock and equipment damage.
All wiring must agree with applicable codes, ordinances, and regulations. An opening is provided to accommodate rigid conduit or armored cable for line voltage operation (Fig. 3 and 4). Do not overload the switch contacts (see Switch Ratings in Specifications section). The switching schematic is shown in Fig. 5.
SET POINT ADJUSTMENT SCREW
OPENING FOR 1/2 INCH CONDUIT
SCALE PLATE
BLEED FITTING
COVER SCREW
MANUAL RESET LEVER ON LOCKOUT MODELS ONLY
COVER SCREW
SCALE PLATE
BLEED FITTING
Fig. 4. C645C with cover removed.
OPENING FOR 1/2 INCH CONDUIT
SET POINT ADJUSTMENT SCREW
M7561
MICRO SWITCH
MANUAL RESET LEVER ON LOCKOUT MODELS ONLY
Fig. 3. C645A,B,D with cover removed.
M7560
Fig. 5. Schematic showing switch in zero
pressure condition.
5
60-2159—8
C645A-E PRESSURE SWITCHES
SETTINGS AND ADJUSTMENTS
Pressure Setpoint Adjustment
Tables 2 through 4 give the pressure and switching for each setpoint. To adjust the pressure setting, turn the setpoint adjustment screw (Fig. 3 and 4) clockwise to increase the pressure setting and counterclockwise to decrease the pressure setting.
Table 2. C645A,D,E control points.
Pressure
Setpoint Switching
a
3
R-W makes 3 0.8
in. of Water
R-B makes 2 0.5
b
9 15 21
b
c
R-W makes 9 2.2 R-W makes 15 3.7 R-W makes 21 5.2
R-B makes 18 4.5
d
35
R-W makes 35 8.7
R-B makes 31 7.7
a
Nominal differential1 in. of water (0.2 kPa).
b
Differential between 1 and 3 in. of water (0.2 and 0.7 kPa).
c
Maximum differential3 in. of water (0.7 kPa).
d
Maximum differential4 in. of water (1.0 kPa).
Table 3. C645B control points.
Pressure
Setpoint Switching
a
3
R-W makes 3 0.8
in. of Water
R-B makes 2 0.5
b
9 15 21
b
c
R-W makes 9 2.2 R-W makes 15 3.7 R-W makes 21 5.2
R-B makes 18 4.5
d
35
R-W makes 35 8.7
R-B makes 31 7.7
e
45
R-W makes 45 11.2
R-B makes 39 9.8
a
Nominal differential1 in. of water (0.2 kPa).
b
Differential between 1 and 3 in. of water (0.2 and 0.7 kPa).
c
Maximum differential3 in. of water (0.7 kPa).
d
Maximum differential4 in. of water (1.0 kPa).
e
Maximum differential5.7 in of water (1.4 kPa).
Pressure
kPa
Pressure
kPa
Table 4. C645C Control Points.
Setpoint Switching
a
1
R-W makes 1 0.25
Pressure
in. of Water
Pressure
kPa
R-B makes 0.8 0.2
b
3
R-W makes 3 0.75
R-B makes 2.6 0.64
b
5
R-W makes 5 1.24
R-B makes 4.3 1.2
Top Scale
c
R-W makes 6 1.50
R-B makes 5.2 1.3
a
Nominal differential0.2 in. of water (0.05 kPa).
b
Differential between 0.2 and 0.8 in. of water (0.05 and
1.2 kPa).
c
Maximum differential0.8 in. of water (0.2 kPa).
C645B1047 Scaleplate Stop Adjustment
The C645B1047 is the same as the C645B1013 except for a scaleplate stop.
Specifications
Scaleplate Stop:
Limits maximum setting, factory-set at 5-1/4 in. of water (1.31 kPa).
Scale Range:
3 to 21 in. of water (0.75 to 5.23 kPa).
Adjusting Wrench:
Part no. 23466 included with the C645B1047.
To Adjust Scaleplate Stop
Remove cover.Loosen scaleplate stop locking screw about 1/2 turn
counterclockwise with the 23466 Adjusting Wrench.
Move scaleplate stop until
desired maximum setting.
Tighten scaleplate stop locking screw clockwise .Replace cover.
bottom
edge is aligned with
60-2159—8
6
C645A-E PRESSURE SWITCHES
LOCKING SCREW
SET POINT INDICATOR
Fig. 6. Adjusting C645B1047 scaleplate stop.
23466 ADJUSTING WRENCH
SCALEPLATE STOP
M7562
Manual Resetting
The C645A,C manual reset models lock out at scale setting minus the differential and require manual resetting after the pressure rises to scale setting to resume normal operation.
The C645B locks out at scale setting and requires manual resetting after the pressure falls to scale setting minus the differential to resume normal operation. To reset, push the reset button as far as it will go; then release.
The C645B spring-loaded diaphragm actuates the Micro Switch snap-acting switch which breaks a control circuit, locks out, and turns on an alarm (if so wired) when the pressure rises to the scale setting. When pressure falls to the scale setting minus the differential, the switch lockout can be manually reset, turning off the alarm
Checkout
C645A,BGas or Air Switch
Set cutoff pressure.Open main supply line. Depress reset lever on lockout
models until switch makes R-W.
Set controller and limit switch to call for heat.For C645Aclose main shutoff valve. Valve should
close when pressure reaches cutoff point. For C645Bwait a few minutes for the pressure to rise; then lower the scale setting until the switch makes R-W and locks out.
NOTE: To more accurately check C645A, use slow
bleedoff. For C645B, jumper other limit and let pressure rise to cutoff setting.
For C645A—reconnect the control valve, open the
shutoff valve, press the reset lever (if necessary), and return the pressure switch to its original setting. For C645Braise setting to normal. Depress reset lever.
Allow system to operate through at least one complete
cycle to make certain all components are functioning properly.
IMPORTANT
Lockout models cannot be made to recycle automatically by permanently holding in the reset lever.
OPERATION AND CHECKOUT
Operation
The C645A,C,D,E spring-loaded diaphragm actuates the Micro Switch snap-acting switch to break a control circuit when pressure falls to scale setting minus differential. The switch can be wired to turn on an alarm at the same time. When the pressure rises to the scale setting, the control circuit requires manual resetting to reset and turn off alarm. Optional C645A model will recycle automatically when the control circuit returns to scale setting.
C645C,DAir Switch Only
Set cutoff pressure.Turn on fan.If using a manual rest C645, depress and hold lever
until switch makes R-W.
Block fan inlet or filter area. Switch should break R-W,
make R-B when pressure drops to cutoff point. Manual reset models lock out.
Remove obstruction. Depress reset lever and allow
system to operate through at least one complete cycle to make certain all components are functioning properly.
C645E1002Distillate Fuel Oil Switch
The C645E1002 is the same as the C645A1006 Gas
Pressure Switch except the C645E1002 has a 0.125 in. NPT main connection in its pressure chamber.
See Checkout for C645A.
7
60-2159—8
C645A-E PRESSURE SWITCHES
Home and Building Control
Honeywell Inc. 1985 Douglas Drive North Golden Valley, Minnesota 55422
60-21598 F.P. Rev. 5-95
60-21598
Home and Building Control
Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9
8
www.honeywell.com/bbc
Loading...