Honeywell C6097A, C6097A,C6097A2110, C6097A2210, C6097A2310, C6097A2410 Instruction Sheet

...
Honeywell
UNIVERSAL GAS VALVES
C6097A
APPLICATION
The gas pressure switch C6097A is used to detect the pressure of city gas, natural gas,
When the gas pressure changes, the diaphragm ofthe pressure receiving part detects it and operates the (SPOT) switch to ON/OFF control of the external electrical circuit.
These switches are widely used to detect the upper limit or lower limit pressure of gas or air to be supplied to a gas burner, or to detect the clogging of the interlock filter of a
(/)
"0
burner blower.
C
ctJ
~
.J::
SPECIFICATIONS
CD
Z
Product
There are two versions available: stand alone and flange
"0
mounted, see table 1. and
C
it
U
~
C
:;
o
Cl
C
ctJ
.J::
U
.B
t5
E
:l
(f)
range
Table 1. C6097A
Model
C6097A2200 2.5 C6097A2300 30 C6097A2400 100
Operating
pressure
(mbar) (mbar) (mbar)
range
...
50 0.6
...
150 2.8
...
500 7.0
2.
flanged
LP
gas or air etc.
mounted
Nominal
operating
differential
models
Maximum
working
pressure
300 500 600
GAS
Table 2. C6097A
Model
C6097A2110 1.0 C6097A2210 2.5 C6097A2310 30 C6097A2410 100
NOTE: The operating differential
Dimensions See Figure 1. Connection Inlet positive pressure Rp1/4" internal pipe thread (2 Differential pressureRp1/8" internal pipe thread.
All connections according to ISO 7-1 Set
15% of the full scale (when pressure is increased)
NOTE: The knob readings are approximations of the actual
Torsion Pipe connections meet group2,according to EN161
requirements. Contact Resistive load: 250 Vac, 5A
Inductive load: 250 Vac, 3A (power factor 0.6) Minimum contact current and voltage: 50 mA, 24 Vac
Materialofpressure NBR single diaphragm Materialofhousing Aluminium Materialofcase Polybutylene terephthalate Materialofcover Polycarbonate Ambient
-15 Relative humidity: max. 90% at 40 C (non-condensing)
Sensed
-15 Electrical Plug connection according to
connector ("DIN plug") Protection against electrical shock: class I
Wire M3.5 screw terminals, including earth connection
the upper and lower operating pressures at one set point.
point
accuracy
settings.
and
bending
ratings
die-cast
temperature
...
60 C
medium
...
80 C
connection
connection
PRESSURE
stand
Operating
pressure
range
(mbar)
...
10 0.4 200
...
50 0.6
...
150 2.8
...
500 7.0
stress
receiving
range
temperature
terminals
parts
range
SWITCHES
INSTRUCTION
alone
models
Nominal
operating
differential
(mbar) (mbar)
IS the difference between
PG11
or three pin plug
EN1
R-9172
SHEET
Maximum
working
pressure
300 500 600
x).
9907R1-NE
Enclosure
IP54
Seals
and
gaskets
Hydrocarbon
resistant
NBR
INSTALLATION
1.
Read these instructions carefully. Failuretofollow the instructions could damage the product
cause a hazardous condition.
2.
Check the ratings giveninthe instructions the product for
your
Stand alone models
to
application.
rubber
type
or
and
make sure the product is suitable
c
on
Standards
The
C6097A
directives:
Gas
Appliance
PIN:
Low
Voltage
Electro
and
Approvals
pressure
CE-0063AR1571
Magnetic
3.
The installation hastobe carried outbyqualified
Directive
Directive
Compatibility
switch
conforms
(90/396/EEC)
(73/23/EEC)
with
Directive
the
following
(89/336/EEC)
personel only.
4.
Carry out a thorough checkout when installation is
completed.
5.
Electrical installation must beinaccordance with local requirements.
E=j68
EC
H
J
--tlF---,-------t--,--,,_
Flanged mounted models
H
J
--ttf---,-------t--,--,,_
D
K
G
B
C
K
B
1----
E
52
------1
61
52
69
F
1----=---.::--
-----
69-------1
69
-------I
74
49,5
E
A Bracket mounting hole B Cover screw
Dial
three
indicator
22mm(for
pin
(DIN) plug connection
C D Conduit hole
E Inlet positive pressure F Pressure test nipple
EN1R-91729907R1-NE
(3),M4tapping, depth 5
plug
connection
(Rp
1/4")
(0
9)
Fig. 1. Installation drawing C6097A gas pressure switch
PG11)
mm
or,
G Differential pressure
~}
w;"
ooo"d;oo
L Earth connection terminal M Mounting screw holes
2
(Rp
1/8")
",m;,,'
(2
x 4.5
mm)
for flanged versions
Loading...