Honeywell AQ251 Catalog Page

AQUATROL Zoning System
AQ251 Electronic Boiler Reset Control Panel for Hydronic Zoning System
• Displays outdoor temperature on all AQ1000 thermostats when used with an AQ12C10 outdoor sensor (included).
• Intuitive programming interface and armchair programming (can be programmed at your desk and taken to the job site “ready-to-install”)
• Customizable control settings and schedules allow for greater level of control and comfort.
• Central programming of zone set points and setback.
• Controls up to 2 stages of heat from a single thermostat.
• Zoning Control for up to four zones as shipped; can be expanded to a total of 16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64 zones by using AQ254 Add-a-Temperature expansion panels.
The AQ251 family of AQUATROL Boiler Reset Controls provides simplified, energy-efficient outdoor temperature compensated control of single temperature, residential hydronic heating systems. The AQ251 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for increased energy efficiency with reduced boiler cycling. AQ251 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry.
• Use with AQ1000 2-wire communicating thermostats (AQ25142B and AQ25144B) or most digital dry contact thermostats (AQ25110B, AQ25142B, and AQ25144B).
• 0-10 Vdc modulating output for driving a modulating/condensing boiler.
Application: Boiler reset control for hydronic zoning system Powe r Su pply: 120V/60Hz User Interface (Setting, Programming): (LCD Display and a 7 button
Key Pad)
Electrical Connections (Line Voltage): Wire-clamp screw terminals,
Maximum 2 x 14 AWG each on line voltage terminals
Control and Zoning Panel Temperature Rating: 32 F to 130 F (0 C to
55 C)
Thermostat Compatibility: AQ1000 Series 2-wire communicating
thermostats and most digital thermostats
Setback Program: 7 day, up to 2 setback periods/day. Boiler Design Temperature: 80F to 210F (26C to 99C) Boiler (Supply) Min. Control Temperature: OFF, 59F to 180F (OFF,
15C to 82C)
Boiler (Supply) Max. Control Temperature: OFF, 120F to 225 F
(OFF, 49C to 107 C)
Boiler Heat Post Purge: Off, 10 seconds to 30 minutes (factory default
is 30 seconds)
Boiler (T-T) Output Rating: 24 Vac, 0.5A, 12VA Boiler Differential: 2F to 41F (1C to 23C), or Auto (minimum 2 minutes
on time)
DHW Pump/Valve Output Rating: 120 Vac/250 Vac 5A, 1/3HP DHW Demand Input: External dry contacts connection only Outdoor Low Design Control Temperature: Return Minimum Control Temperature: 80 F to 180 F (27C to 82C)
-60F to 32F (-51 C to 0 C)
• Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback.
• Zone synchronization through Zone of Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Line or low-voltage output for zoning equipment (pumps or valves).
• Boiler short cycling protection.
• Boiler post purge.
• Freeze protection.
• Pump/valve exercise.
• Boiler shock prevention from cold water returning to boiler.
• Automated test and purge feature for quick start-up and simplified troubleshooting.
• Integral 38 VA transformer with self resetting electronic fuse.
• 2 hour power supply (super-capacitor) to retain day and time settings during power outage.
• Non-volatile EPROM memory retains program settings during power outage.
Pump/Valve exercise: 30 seconds per 2 weeks of space heating
inactivity
Auxiliary Pump Output Rating: Dry contact output, 120 Vac/250 Vac
5A, 1/3 HP
Auxiliary Low Voltage Output Rating: 24 Vac, 0.5A, 12VA Auxiliary (Demand) Input: External dry contacts connection only WWSD (Warm Weather Shut Down) Temperature: Off, 35 F to 100 F
(Off, 1 C to 38 C)
Sensor Temperature Rating: -58 F to +230 F (-50 C to +110 C) Supply/Return Sensor: Lead Length: 10 ft. (3050 mm). 10 kilohm NTC
thermistor at 25 C (77 F) ±0.5F (±0.3C) up to 500 ft (150 M) using 18 AWG or larger wire
Heat Demand (Thermostat R-W) Input: External dry contacts
connection only
B-B Communication Bus Terminals: Low voltage, Class II, 2-wire
polarity-insensitive, digital communicating link to other Control or Zoning modules.
R-C Input (on Control and Zoning Modules): 24 Vac Class II (input
on Control and Zoning Modules)
R-C Output (on transformer): 38 VA, 24 Vac Class II Operating Humidity Range (% RH): 5 to 90% RH, non-condensing Approvals Canadian Standards Association: CSA C/US Certified to CSA and
UL Standards, File No. LR76030
Controls
Hydronic
Type of Zoning
Product Number
* AQ25110B/U None 1 (non-
* AQ25142B/U Pumps or 2-
* AQ25144B/U Zone valves
* TRADELINE models • SUPER TRADELINE models
Devices Controlled
wire valves
with end switches
Number of Zones Controlled
communicating)
4 120 Vac/250
4 120 Vac/250
Boiler Pump Output Rating
120 Vac/250 Vac 5A, 1/3HP
Vac 5A, 1/3HP
Vac 5A, 1/3HP
Dimensions, Approximate Weight
Replacement Partsinch mm lb kg
13 in wide x 8 in. high x 3 3/8 in deep
16 1/2 in wide x 8 in. high x 3 3/8 in deep
16 1/2 in wide x 8 in. high x 3 3/8 in deep
70-6910 187
33 cm wide x
20.3 cm high x
8.5 cm deep
42 cm wide x
20.3 cm high x
8.5 cm deep
42 cm wide x
20.3 cm high x
8.5 cm deep
4.9 lbs 2.3 kg
5.7 lbs 2.6 kg
5.7 lbs 2.6 kg
AQ15100B boiler reset module; AQ12C11 supply/return/mixed loop sensor; AQ12C10 outdoor sensor; AQ10X38 24 Vac 38 VA transformer
AQ15100B boiler reset module; AQ12C11 supply/return/mixed loop sensor; AQ12C10 outdoor sensor; AQ10X38 24 Vac 38 VA transformer; AQ15540B 4-zone pump expansion module
AQ15100B boiler reset module; AQ15740B 4-zone valve with end switch expansion module; AQ12C11 supply/return/mixed loop sensor; AQ12C10 outdoor sensor; AQ10X38 24 Vac 38 VA transformer