INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
5800ZBRIDGE is a wireless, intelligent energy
management device that provides an interface
between Z-Wave Modules and Honeywell LYNX
Security Systems and VISTA Control Panels that are
equipped with RF keypads.
Note: The 5800ZBridge is not compatible with the 5800TM or
5883H modules.
Features
• Automatically set back Z-Wave enabled
thermostat when security system is Armed
AWAY.
• Automatically turns lights off when security
system is Armed AWAY.
• Sends run command to Z-Wave enabled
thermostat when security system is Disarmed.
• Automatically turns lights on when security
system is Disarmed.
• Alarm Status light: Ready, Armed Away and Stay.
• Will function with any Z-Wave device
MOUNTING
1. Determine the optimum mounting location taking
care to avoid damp locations. To maximize the
transmitter’s range, avoid mounting the device to
metal objects, if possible. The module should be
located a maximum of 6 feet from an unswitched
120VAC outlet.
2. Open the 5800ZBRIDGE case as shown in Figure
1.
3. Mount the 5800ZBRIDGE using the provided
screws. (Refer to Figure 2)
800-08932 5/11 Rev. A
5800ZBRIDGE
Z-Bridge Module
POWER UP MODULE
1. Plug in 12VDC power supply, LED flashes
ORANGE 3 times and then goes out. (Refer to
Figure 2)
PROGRAMMING
Enroll 5800TM Code into Module
1. Press SW5 LEARN switch for 1 second and
release. LED will begin flashing ORANGE.
2. Disarm or Arm the control panel (with 5800TM
code turned on). The LED will stop flashing
ORANGE and the color will follow status of the
control panel.
Note: The module will time out of program mode after 3
minutes if no TM code is enrolled.
Table 1 - 5800ZBRIDGE LED Indications
Indication Meaning
Flashing Red Armed AWAY
Steady Red Armed STAY
Solid Green Ready
Flashing Orange ALARM/Panic
Note: Following an alarm, the User Code must be entered
twice and the keypad must go to ready in order for the
Z-Bridge Module to release thermostat setback and/or
turn on lights.
Enroll (include) Devices in Z-Wave Modules into
5800ZBRIDGE module
1. Press the corresponding switch (SW1 through 4)
for 1 second and release for any combination of
four Thermostats or Lights. (Refer to Figure 2)
2. The 5800ZBRIDGE LED will begin flashing
Green.
3. Press button on the respective Z-Wave device to
learn (include) the device. The 5800ZBRIDGE
LED will stop flashing GREEN and return to
status of control panel.
4. Repeat for each Z-Wave device as applicable.
Note: The module will time out of program mode after 2
minutes if no Z-Wave device in enrolled (included).
Reset 5800ZBRIDGE Module
1. Disconnect the 12VDC power supply.
2. Press and hold SW5 LEARN switch and then plug
in 12VDC power supply. LED flashes Orange 5
Figure 1. Opening the 5800ZBRIDGE
- 1 -
times and then goes out.
3. Release switch SW5. TM code has been deleted
and 5800ZBRIDGE has been deleted (excluded)
from the Z-Wave network.
4. Unplug the 12VDC power supply and plug it back
5800Z-001-V0
SW1 to SW4
TERMINALS
MOUNTING
HOLES (2)
SW5
12 VDC
POWER SUPPLY
RECEPTACLE
in to the 5800ZBRIDGE.
5. Program the 5800ZBRIDGE in accordance with
the PROGRAMMING section.
Deleting (excluding) Z-Wave modules/devices
Delete (exclude) Z-wave modules/devices from the
5800ZBRIDGE when they are no longer required.
1. Press and hold (5 seconds) the SW1, SW2, SW3 or
SW4 switch as applicable to remove a device.
2. Release the switch.
3. The 5800ZBRIDGE LED will begin flashing RED.
4. Press the Z-Wave device to allow host to delete
(exclude) the module.
5. The LED will stop flashing RED and return to
status of security panel.
Include/Exclude/Receive Primary Role of
5800ZBRIDGE to/from another Z-Wave Network
1. Set another Z-Wave controller into Include,
Exclude, or Controller Shift mode.
2. Press and hold SW1 and SW2 on the
5800ZBRIDGE for 5 seconds, LED will blink
between GREEN and ORANGE.
Note: The LED will blink until process finishes or times out (5
seconds).
3. If the process:
- is successful, the LED will turn GREEN
- times out, the LED stops blinking
- fails, the LED will turn RED
Note: If the Z-Bridge has been removed from a network it is
recommended the user/installer rest the Z-Bridge
device.
Relinquish (shift) Primary Role to another control
within a Z-Wave Network
1. Press and Hold SW3 and SW4 on the
5800ZBRIDGE for 5 Seconds, LED will
alternately blink RED and ORANGE.
2. Put other Z-Wave controller into Learn Mode
Note: The LED will blink until process finishes or times out
(30 seconds).
3. If the process:
- is successful, the LED will turn GREEN
- times out, the LED stops blinking
- fails, the LED will turn RED
NORMAL OPERATION
1. When the Security System is armed or disarmed
it will operate as noted in Table 2.
2. If the Security System has gone into alarm the
5800ZBRIDGE LED will flash ORANGE. To reset
the module you will need to clear the Alarm by
disarming the system two times (enter two OFF
sequences via the keypad or keyfob).
Table 2 – ZBRIDGE System Operation
Armed AWAY = Thermostat Set back/ Energy
Save mode
Lights OFF
Armed STAY = Thermostat normal/run mode
Lights ON
Disarm = Thermostat normal/run mode
Lights ON
MANUAL OPERATION
Connect a jumper wire between screw terminals on
the 5800ZBRIDGE. This will activate the device and
send the Z-Wave setback command. The LED will
indicate the system operation by illuminating as
follows:
RED = Sent Setback command
GREEN = Sent Release Setback command
TESTING
1. Test each device by arming and disarming
FREQUENTLY ASKED QUESTIONS AND TROUBLESHOOTING
How many devices can the 5800ZBRIDGE control? 5800ZBRIDGE can control up to four (4) Z-Wave devices
When I press the first 5800ZBRIDGE button the light flashes
red one time and stops?
After the System goes into alarm I entered the code but the
5800ZBRIDGE still blinks orange?
security system. Refer to Table 2 for System
Operation.
Question Answer
FIGURE 2. 5800ZBRIDGE
Unplug the unit and plug it back in.
The System needs to have a green ready on the keypad, you
need to disarm the system again to clear the memory.
- 2 -