Honeywell 1991i, 1991i SR, 1991i XR Quick Start Guide

Granit™ XP 1991i

Cordless Industrial Area-Imaging Scanner

Quick Start Guide

1991-EN-QS-01 Rev A
5/20
Agency Model: 1991i, 1991iSR, 1991iXR
your device.

Getting Started

Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected. When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery or charge pack is charging.

Power Supply Assembly (if included)

Note: The power supply must be ordered separately, if needed.
1

Connecting the Base

USB:

Note: If you are charging the scanner using the USB cable, the
current available for charging is reduced and charge times are increased. Charging via the power supply is faster.
2

Keyboard Wedge:

3

RS232 Serial Port:

4

Reading Techniques

SR Models: XR Models:

Standard Product Defaults

The view finder projects an aiming beam that should be cen­tered over the barcode, but it can be positioned in any direction for a good read.
Note: If the scanner beeps 3 times when scanning a barcode, the
link has not been established. If the scanner beeps once, the link has been established.
Standard Product Defaults
The following barcode resets all standard product default set­tings.
5

USB Serial

USB Serial

USB PC Keyboard

If you are using a Microsoft® Windows® PC, you must download a driver from the Honeywell website. The driver will use the next available COM Port number.
Scan the following code to program the scanner to emulate a regular RS232-based COM Port. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automati­cally use a class driver.
Note: No extra configuration (e.g., baud rate) is necessary.
USB PC Keyboard
Scan the following code to program the scanner for a USB PC Keyboard.
6

Keyboard Country

USA (Default)
Belgium
Denmark
Finland
France
Germany/Austria
Scan the appropriate country code below to program the key­board layout for your country or language. By default, national character replacements are used for the following characters: #$@[\]^‘{|}~. Refer to the ISO 646 Character Replacements chart in your User Guide to view the character replacements for each
country.
7
Note: For a complete list of country codes, see the User Guide for
Great Britain
Italy
Norway
Spain
Switzerland
Locked Link Mode
(Single Scanner)
your product.

Locked Link

If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inad­vertently placed into the base. If you do place a different scan­ner into the base, it will charge the scanner, but the scanner will not be linked.
8
To use a different scanner, you need to unlink the original scan-

Override Locked Scanner

Unlink Scanner
ner by scanning the Unlink Scanner barcode.
Override Locked Scanner
If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner barcode with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked.

Unlinking the Scanner

If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked. Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner barcode to unlink a scanner.
9

Trigger

Manual Trigger - Normal
(Default)
Presentation Mode
Streaming Presentation Mode
The following barcodes will allow you to use the scanner in Manual Trigger - Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a barcode).
Note: Presentation Mode continuously draws power, so use of
the external power supply is recommended for this mode.

Streaming Presentation™

When in Streaming Presentation mode, the scanner leaves the scan illumination on all the time and continuously searches for barcodes.
10

Suffix

Add CR Suffix
Add Tab Suffix
Remove Suffix

Add Code ID Prefix To All Symbologies

(Temporary)
If you want a carriage return after the barcode, scan the Add CR
Suffix barcode. To add a tab after the barcode, scan the Add Tab Suffix barcode. Otherwise, scan the Remove Suffix barcode to
remove the suffixes.
Add Code ID Prefix to all Symbologies
Scan the following barcode if you wish to add a Code ID prefix to all symbologies at once.
Note: For a complete list of Code IDs, see the User Guide for your
product.
11

Function Code Transmit

Enable
(Default)
Disable
When this selection is enabled and function codes are con­tained within the scanned data, the scanner transmits the func­tion code to the terminal. Charts of these function codes are provided in your User Guide. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it
is transmitted.
12

Support

To search our knowledge base for a solution or to log into the Technical Support portal and report a problem, go to
www.hsmcontactsupport.com.

User Documentation

For the user guide and other documentation, go to
www.honeywellaidc.com.

Limited Warranty

For warranty information, go to www.honeywellaidc.com and click Resources > Product Warranty.

Patents

For patent information, see www.hsmpats.com.

Disclaimer

Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not repre­sent a commitment on the part of HII.
HII shall not be liable for technical or editorial errors or omis­sions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. HII disclaims all responsibility for the selection and use of software and/or hardware to achieve intended results.
13
This document contains proprietary information that is pro­tected by copyright. All rights are reserved. No part of this docu­ment may be photocopied, reproduced, or translated into another language without the prior written consent of HII.
Copyright2020 Honeywell International Inc. All rights reserved.
14