Keep this owner ’s manual handy so that you can refer to it at any time. This owner ’s manual
is considered a permanent part of the pumpset and should remain with the pumpset if
resold.
The information and specifications included in this publication were in effect at the time of
approval for printing. Honda Siel Power Products Ltd. reserves the right, however, to
discontinue or change specifications or design at any time without notice and without
incurring any obligation whatsoever.
Honda Selling Dealer
Name :
Address :
Tel. No. :
P.D.I. Date :
Warranty valid upto :
Usage Type : Commercial Non-commercial Rental
INTRODUCTION
Congratulations on your selection of a Honda Portable Pumpset. We are certain you will be
pleased with your purchase of one of the finest pumpset in the market.
We want to help you get the best results from your new pumpset and to operate it safely.
This manual contains all the information on how to do that; please read it carefully.
As you read this manual, you will find information preceded by a symbol. That
information is intended to help you avoid damage to your pumpset, other property, or the
environment.
We suggest you read the warranty policy to fully understand its
responsibilities of ownership.
When your pumpset needs scheduled maintenance, keep in mind that
dealer is specially trained in servicing Honda Pumpset. Your authorized Honda servicing
dealer is dedicated to your satisfaction and will be pleased to answer your questions and
concerns.
We welcome your valuable suggestions & feedback.
Kindly send your feedback
to Marketing Manager :
or else
Honda Siel Power Products Limited
Phone No.: 0120-2341050~59 Fax: 0120-2341078~79
e-mail : ho.mktg@hspp.com
Working Hours : 08:15 A.M. to 05:15 P.M. (Mon to Fri)
contact our Customer Care
Centre for Support :
Best Wishes,
Honda Siel Power Products Ltd.
To access information about Operations,
Maintenance & Troubleshooting, please visit:
www.hppsv.com/IND/
Toll Free No. :
Working Hours : 09:00 A.M. to 06:00 P.M.
(Available Monday to Sunday except on Public Holidays)
or scan
coverage and your
your Honda servicing
1800 1 1 232 3
1
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important. And using this Pumpset
important responsibility.
To help you make informed decisions about safety, we have provided operating
procedures and other information on labels and in this manual. This information alerts you
to potential hazards that could hurt you or others.
Of course, it is not practical or
operating or maintaining a pumpset. You must use your own good judgement.
You will find important safety information in a variety of forms, including:
possible to warn you about all the hazards associated with
safely is an
• Safety Labels– on the pumpset.
• Safety Messages
These signal words mean:
– preceded by a safety alert symbol and one of three signal words,
DANGER, WARNING, or CAUTION.
You WILL be KILLED or SERIOUSLY HURT if
follow instructions.
You WILL be KILLED or SERIOUSLY HURT if
follow instructions.
You CAN be HURT if you don’t follow instructions.
you don’t
you don’t
• Safety Headings – such as IMPORTANT SAFETY INFORMATION.
• Safety Section – such as PUMPSET SAFETY.
• Instructions– How to use this Pumpset correctly and safely.
This entire book is filled with important safety information – please read it carefully.
............................................ I - IV
25
26
4
5
6
3
PUMPSET SAFETY
IMPORTANT SAFETY INFORMATION
Most accidents with pumpset can be prevented if you follow all instructions in this manual
and on the pumpset. Some of the most common hazards are discussed below, along with
the best way to protect yourself and others.
Operator Responsibility
Know how to stop the pumpset quickly in case of emergency.
•
Be sure that anyone who operates the pumpset receives proper instruction. Do not let
•
children operate the pumpset without parental supervision.
Carbon Monoxide Hazards
Engine’s exhaust contains toxic carbon monoxide, which you
Breathing carbon monoxide can KILL YOU IN MINUTES. To avoid carbon monoxide
poisoning, follow these instructions when operating a pumpset.
•
Only run a pumpset OUTSIDE, far away from windows, doors, and vents.
Never operate a inside a house, garage, basement, crawl
•
or partially enclosed space. Never ever operate a pumpset inside deep well.
Never operate a near open doors or windows.pumpset
•
•
Get fresh air and seek medical attention immediately if you suspect you have inhaled
carbon monoxide.
Early symptoms of carbon monoxide exposure include headache,
breath, nausea, and dizziness. Continued exposure to carbon monoxide can cause loss of
muscular coordination, loss of consciousness, and then death.
Fire and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
•
–
Keep the at least 1 meter away from buildings and other
operation.
–
Do not enclose the pumpset in any structure.
–
Keep flammable materials away from the .pumpset
pumpsetspace, or any enclosed
pumpsetequipment during
cannot see or smell.
fatigue, shortness of
The muffler becomes very hot during operation and remains hot for a
•
the pumpset. Be careful not to touch the muffler while it is hot. Let the engine cool
before storing the pumpset indoors.
Refuel With Care
Petrol and kerosene is extremely flammable, and petrol vapour can explode.
Allow the engine to cool if it has been in operation.
Refuel only outdoors in a well-ventilated area with the engine off.
Do not refuel during operation.
Do not overfill the fuel tank.
Never smoke near petrol and kerosene, and keep other flames and sparks away.
Always store petrol in an approved container.
Make sure that any spilled fuel has been wiped up before starting the pumpset.
while after stopping
4
SAFETY INSTRUCTIONS
To ensure safe operation
PLEASE DO NOT USE PUMPSET INSIDE AN
ENCLOSED AREA. ENSURE ADEQUATE
VENTILATION WHILE PUMPSET IS IN
OPERATION.
Honda pumpset is designed to give safe and
dependable service if operated according to
instructions.
Read and understand the Owner’s Manual
before operating the pumpset. Failure to do so
could result in personal injury or equipment
damage.
WARNING!
TO PREVENT FIRE HAZARDS, KEEP THE UNIT IN
OPERATION. ATLEAST 3 FT. (1MTR.) AWAY FROM THE
BUILDINGS / EQUIPMENTS / COMBUSTIBILE OR
INFLAMMABLE MATERIALS.
EXHAUST GAS CONTAINS
POISONOUS CARBON MONOXIDE.
DO NOT CONNECT PIPE TO
EXHAUST MUFFLER.
DO NOT PUT A DUST COVER
ON THE PUMPSET WHILE IN
OPERATION.
WHILE REFILLING, STOP ENGINE AND DO
NOT SMOKE,WIPE SPILLING FUEL.
CAUTION
SPILLED FUEL MAY CAUSE FIRE.
20
INCLINATION OF PUMPSET
SHOULD NOT EXCEED 20°
DURING OPERATION.
5
COMPONENT IDENTIFICATION
6
7
15
5
10
8
3
1
2
11
12
4
13
14
9
16
6
5
15
7
8
4
1
THROTTLE LEVER
2
ENGINE OIL DRAIN BOLT
3
DRAIN COCK
4
CHOKE ROD
5
AIR CLEANER
6
PETROL TANK CAP
7
KEROSENE TANK CAP
8
FUEL COCK
9
ENGINE OIL FILLER CAP
10
ENGINE SWITCH
11
PRIMING WATER FILLER CAP
12
DISCHARGE PORT
13
SUCTION PORT
14
PUMP DRAIN PLUG
15
MUFFLER
16
STRAINER
2
3
10
9
1
11
12
13
14
6
PRE-OPERATION CHECK
Always check the following items before you start the pumpset.
Check the General Condition of the Pumpset.
1. Look around and underneath the pumpset for signs of oil or petrol leaks.
2. Remove any excessive dirt or debris, especially around the muffler and recoil starter.
3. Look for sign of damage.
4. Check that all shields and covers are in place, and all nuts, bolts, and screws are
tightened.
1. OIL LEVEL
CAUTION:
Be sure to check the pumpset
on a level surface with the
pumpset stopped.
1. Check the oil level, if the oil level is low.
2. Fill the oil to the upper level.
4-STROKE MOTOR OIL
SAE 10W- 30
API SF or above
OIL ALERT SYSTEM
1.
If the oil in the crankcase falls below a safe limit then the
oil alert system will automatically turn the pumpset OFF.
ON
OFF
2.
In that case fill the oil to upper level and restart the pumpset.
CAUTION
Check engine oil before each operation. Use only recommended engine oil.
ON
OFF
7
Loading...
+ 24 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.