The engine exhaust from this product
contains chemicals known to the State
of California to cause cancer, birth
defects or other reproductive harm.
Keep this owner’s manual handy, so you can refer to it at any time.
This owner’s manual is considered a permanent part of the water
pump and should remain with the water pump if resold.
The information and specifications included in this publication were in
effect at the time of approval for printing. Honda Motor Co., Ltd.
reserves the right, however, to discontinue or change specifications or
design at any time without notice and without incurring any obligation
whatever. No part of this publication may be reproduced without
written permission.
INTRODUCTION
Congratulations on your selection of a Honda water pump. We are
certain you will be pleased with your purchase of one of the finest
water pumps on the market.
We want to help you get the best results from your new water pump
and to operate it safely. This manual contains the information on how
to do that; please read it carefully.
As you read this manual, you will find information preceded by a
symbol. That information is intended to help you avoid
damage to your water pump, other property, or the environment.
We suggest you read the warranty policy to fully understand its
coverage and your responsibilities of ownership. The warranty policy
is a separate document that should have been given to you by your
dealer.
When your water pump needs scheduled maintenance, keep in mind
that your Honda servicing dealer is specially trained in servicing
Honda water pumps. Your Honda servicing dealer is dedicated to your
satisfaction and will be pleased to answer your questions and
concerns.
Best Wishes,
Honda Motor Co., Ltd.
1
INTRODUCTION
A FEW WORDS ABOUT SAFETY
Your safety and the safety of others are very important. And using this
water pump safely is an important responsibility.
To help you make informed decisions about safety, we have provided
operating procedures and other information on labels and in this
manual. This information alerts you to potential hazards that could
hurt you or others.
Of course, it is not practical or possible to warn you about all the
hazards associated with operating or maintaining a water pump. You
must use your own good judgment.
You will find important safety information in a variety of forms,
including:
Safety Labels
Safety Messages
of three signal words, DANGER, WARNING, or CAUTION.
These signal words mean:
Safety Headings
Safety Section
Instructions
This entire book is filled with important safety information –– please
read it carefully.
–– on the pump.
–– preceded by a safety alert symboland one
You WILL be KILLED or SERIOUSLY HURT if
you don’t follow instructions.
You CAN be KILLED or SERIOUSLY HURT if
you don’t follow instructions.
.......................................................Customer Service Information. 58
...........................QUICK REFERENCE INFORMATION. Inside back cover
PUMP SAFETY
IMPORTANT SAFETY INFORMATION
Honda WB20X and WB30X pumps are designed to pump only water
that is not intended for human consumption, and other uses can result
in injury to the operator or damage to the pump and other property.
Most accidents can be prevented if you follow all instructions in this
manual and on the pump. The most common hazards are discussed
below, along with the best way to protect yourself and others.
Operator Responsibility
It is the operator’s responsibility to provide the necessary safeguards
to protect people and property. Know how to stop the pump quickly in
case of emergency. If you leave the pump for any reason, always turn
the engine off. Understand the use of all controls and connections.
Be sure that anyone who operates the pump receives proper
instruction. Do not let children operate the pump. Keep children and
pets away from the area of operation.
Pump Operation
Pump only water that is not intended for human consumption.
Pumping flammable liquids, such as gasoline or fuel oils, can result in
a fire or explosion, causing serious injury. Pumping sea water,
beverages, acids, chemical solutions, or any other liquid that
promotes corrosion can damage the pump.
Refuel With Care
Gasoline is extremely flammable, and gasoline vapor can explode.
Refuel outdoors, in a well-ventilated area, with the engine stopped and
the pump on a level surface. Do not fill the fuel tank above the fuel
strainer shoulder. Never smoke near gasoline, and keep other flames
and sparks away. Always store gasoline in an approved container.
Make sure that any spilled fuel has been wiped up before starting the
engine.
5
PUMP SAFETY
Hot Exhaust
The muffler becomes very hot during operation and remains hot for a
while after stopping the engine. Be careful not to touch the muffler
while it is hot. Let the engine cool before transporting the pump or
storing it indoors.
To prevent fire hazards, keep the pump at least 3 feet (1 meter) away
from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
Carbon Monoxide Hazard
Exhaust gas contains poisonous carbon monoxide. Avoid inhalation of
exhaust gas. Never run the engine in a closed garage or confined area.
6
PUMP SAFETY
SAFETY LABEL LOCATIONS
The labels shown here contain important safety information. Please
read them carefully. These labels are considered permanent parts of
your pump. If a label comes off or becomes hard to read, contact an
authorized Honda servicing dealer for a replacement.
PUMP CAUTION LABEL
7
CONTROLS
COMPONENT & CONTROL LOCATIONS
WB20X
<>
THROTTLE LEVER
LEVER
FUEL VALVE
LEVER
RECOIL STARTER GRIP
PRIMING WATER
FILLER CAP
IGNITION SWITCH
MUFFLER
OIL FILLER
CAP/DIPSTICK
DISCHARGE PORT
FUEL FILLER CAPCHOKE
STRAINER
FRAME
AIR CLEANER
8
SUCTION PORT
PUMP DRAIN CAP
OIL DRAIN PLUG
<>
WB30X
CONTROLS
THROTTLE LEVER
LEVER
FUEL VALVE
LEVER
RECOIL STARTER GRIP
PRIMING WATER
FILLER CAP
IGNITION SWITCH
MUFFLER
OIL FILLER
CAP/DIPSTICK
DISCHARGE PORT
FUEL FILLER CAPCHOKE
STRAINER
FRAME
AIR CLEANER
SUCTION PORT
PUMP DRAIN CAP
OIL DRAIN PLUG
9
CONTROLS
CONTROLS
Fuel Valve Lever
The fuel valve opens and closes
the passage between the fuel tank
and the carburetor.
The fuel valve lever must be in the
ON position for the engine to run.
When the engine is not in use,
leave the fuel valve lever in the
OFF position to prevent
carburetor flooding and to reduce
the possibility of fuel leakage.
Ignition Switch
The ignition switch controls the
ignition system.
The ignition switch must be in the
ON position for the engine to run.
Turning the ignition switch to the
OFF position stops the engine.
FUEL VALVE LEVER
ON
OFF
IGNITION SWITCH
ON
OOFFFF
10
Choke Lever
CONTROLS
The choke lever opens and closes
the choke valve in the carburetor.
The CLOSED position enriches
the fuel mixture for starting a cold
engine.
The OPEN position provides the
correct fuel mixture for operation
after starting, and for restarting a
warm engine.
Throttle Lever
The throttle lever controls engine
speed.
Moving the throttle lever in the
directions shown makes the
engine run faster or slower.
Pump output is controlled by
adjusting the throttle lever. At
maximum throttle position, the
pump will deliver the highest
output volume. Moving the
throttle lever toward the idle
position will decrease the output
volume of the pump.
CHOKE LEVER
OPEN
CCLLOOSSEEDD
THROTTLE LEVER
SLOW
FAST
11
CONTROLS
Recoil Starter Grip
Pulling the recoil starter grip operates the recoil starter to crank the
engine.
RECOIL STARTER GRIP
12
BEFORE OPERATION
ARE YOU READY TO GET STARTED?
Your safety is your responsibility. A little time spent in preparation will
significantly reduce your risk of injury.
Knowledge
Read and understand this manual. Know what the controls do and
how to operate them.
Familiarize yourself with the pump and its operation before you begin
pumping. Know what to do in case of emergencies.
Be sure of what you are pumping. This pump is designed to pump
only fresh water that is not intended for human consumption.
13
BEFORE OPERATION
IS YOUR PUMP READY TO GO?
For your safety, and to maximize the service life of your equipment, it
is very important to take a few moments before you operate the pump
to check its condition. Be sure to take care of any problem you find, or
have your servicing dealer correct it, before you operate the pump.
Improperly maintaining this pump,
or failing to correct a problem
before operation, could cause a
malfunction in which you could be
seriously injured.
Always perform a preoperation
inspection before each operation,
and correct any problem.
Exhaust gas contains poisonous carbon monoxide. Avoid inhalation of
exhaust gas. Never run the engine in a closed garage or confined area.
To prevent fire hazards, keep the pump at least 3 feet (1 meter) away
from building walls and other equipment during operation. Do not
place flammable objects close to the engine.
Before beginning your preoperation checks, be sure the pump is on a
level surface and the ignition switch is in the OFF position.
Check the General Condition of the Pump
Look around and underneath the pump for signs of oil or gasoline
leaks.
Remove any excessive dirt or debris, especially around the engine
muffler, and recoil starter.
Look for signs of damage.
Check that all nuts, bolts, screws, hose connectors and clamps are
tightened.
14
BEFORE OPERATION
Check the Suction and Discharge Hoses
Check the general condition of the hoses. Be sure the hoses are in
serviceable condition before connecting them to the pump.
Remember that the suction hose must be reinforced construction to
prevent hose collapse.
Check that the sealing washer in the suction hose connector is in
good condition (see page).
Check that the hose connectors and clamps are securely installed
(see pagesand).
Check that the strainer is in good condition and is installed on the
suction hose (see page).
Check the Engine
18
19
18
18
Check the engine oil level (see page). Running the engine with a
low oil level can cause engine damage.
Check the air filter (see page). A dirty air filter will restrict air flow
to the carburetor, reducing engine and pump performance.
Check the fuel level (see page). Starting with a full tank will help
to eliminate or reduce operating interruptions for refueling.
33
28
30
15
OPERATION
SAFE OPERATING PRECAUTIONS
To safely realize the full potential of this pump, you need a complete
understanding of its operation and a certain amount of practice with
its controls.
Before operating the pump for the first time, please review the
IMPORTANT SAFETY INFORMATION
BEFORE OPERATION
For your safety, avoid starting or operating the engine in an enclosed
area, such as a garage. Your engine’s exhaust contains poisonous
carbon monoxide gas which can collect rapidly in an enclosed area
and cause illness or death.
Pump only fresh water that is not intended for human consumption.
Pumping flammable liquids, such as gasoline or fuel oils, can result in
a fire or explosion, causing serious injury. Pumping sea water,
beverages, acids, chemical solutions, or any other liquid that
promotes corrosion can damage the pump.
.
on pageand the chapter titled
5
16
OPERATION
PUMP PLACEMENT
For best pump performance, place the pump near the water level, and
use hoses that are no longer than necessary. That will enable the
pump to produce the greatest output with the least self-priming time.
As head (pumping height) increases, pump output decreases. The
length, type, and size of the suction and discharge hoses can also
significantly affect pump output.
Discharge head capability is always greater than suction head
capability, so it is important for suction head to be the shorter part of
total head.
Minimizing suction head (placing the pump near the water level) is
also very important for reducing self-priming time. Self-priming time
is the time it takes the pump to bring water the distance of the suction
head during initial operation.
DISCHARGE
HEAD
SUCTION
HEAD
TTOOTTAALL HHEEAADD
17