Homedics UHE-WM350 Instruction Manual

PLEASE TAKE A
REGISTER YOUR PRODUCT AT:
www.homedics.com/register
Your valuable input regarding this product will help us create the products you will want in the future.
INSTRUCTION MANUAL AND WARRANTY INFORMATION
ONE YEAR LIMITED WARRANTY
UHE-WM350
IMPORTANT SAFETY INSTRUCTIONS
WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:
READ ALL INSTRUCTIONS BEFORE USING
DANGER
• Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use
• Always unplug the unit from the electrical outlet immediately after using and before cleaning
• DO NOT reach for a unit that has fallen into water. Unplug it immediately.
• DO NOT use while bathing or in the shower.
• DO NOT place or store the unit where it can fall or be pulled into a tub or sink.
• DO NOT place or drop into water or other liquids.
• DO NOT use water above 86° Fahrenheit.
– TO REDUCE THE RISK OF ELECTRIC SHOCK:
under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.
WARNING
• Close supervision is necessary when this unit is used by or near children, invalids, or disabled persons.
• Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with this unit.
• NEVER drop or insert any object into any opening.
• DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.
• NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a HoMedics Service Center for examination and repair.
• Always unplug the unit when filling or moving the unit.
• Ensure that your hands are dry when operating the controls or removing the plug.
• Always hold the water tank firmly with both hands when carrying a full tank of water.
• NEVER use the humidifier in an environment where explosive gasses are present.
• DO NOT place the humidifier near heat sources, such as a stove, and do not expose the humidifier to
direct sunlight.
• DO NOT carry this unit by the power cord or use the power cord as a handle.
• To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.
• This product is intended for household use only.
• Caution: All servicing of this humidifier must be performed by authorized HoMedics service personnel only.
– TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:
2
SAVE THESE INSTRUCTIONS CAUTION
• Never cover the unit while it is operating.
• Always keep the cord away from high temperature and fire.
• If the cord sustains damage, you must stop using this product immediately and contact HoMedics
• Perform regular maintenance on the ultrasonic membrane.
• Never use detergent to clean the ultrasonic membrane.
• Never clean the ultrasonic membrane by scraping with a hard object.
• Do not attempt to adjust or repair the unit. Servicing must be performed by professional or qualified
• Stop using this unit if there is an unusual noise or smell.
• Unplug this unit when not in use for a long period of time.
• Do not touch the water or any parts of the unit that are covered by water while the unit is on or
• Never operate without water in the tank.
• Only use water in the tank.
• Never use any additive to the water.
• Do not wash, adjust, or move this unit without first unplugging it from the electrical outlet.
• Keep this unit out of reach of children. Do not allow children to use this unit without supervision.
• DO NOT use outdoors. For indoor use only.
– PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.
consumer relations (see Warranty section for consumer relations contact information).
personnel.
plugged in.
3
UNIQUE FEATURES & SPECIFICATIONS
ULTRASONIC TECHNOLOGY
This humidifier uses ultrasonic high frequency technology to convert the water into 1–5 million super particles that are dispersed into the air evenly.
DIGITAL READOUT
Displays programmed humidity setting, timer setting, warm or cool mist selection and mist output level.
PROGRAMMABLE HUMIDISTAT
Customize the level of humidity between 35% – 60% in 5% increments.
BUILT-IN TIMER
Programmable timer, up to 12 hours.
NIGHT LIGHT / DISPLAY LIGHTS
A useful light feature is included for your convenience, with the option of independent Night Light and Display Light ON/OFF controls.
AUTO SHUT-OFF PROTECTION
When the tanks are empty the unit will shut off automatically.
CAPACITY
2.0 gallon – 7.57 liters
DUAL WATER TANKS
Refill one tank while the other is running.
RUN TIME: 12-120 HOURS
Run time is calculated based on using cool mist and setting the mist level from the high to the low setting. Based on the natural humidity level in your home, the temperature of water you use, and the mist level setting you choose, you may experience longer or shorter run times.
AROMA CAPABLE
Includes 2 essential oil samples and aroma pads, or use your favorite essential oil to deliver aroma into the air.
4
TIMER
+
HUMIDISTATMIST
TOTAL COMFORT ULTRASONIC HUMIDIFIER WARM & COOL MIST
WATER TANKS
TANK CAPS
MIST SPOUT
ESSENTIAL OIL TRAY*
DIGITAL CONTROL PANEL
POWER PLUG
ULTRASONIC
1
ULTRASONIC
1
DISC*
COVER*
* These items are accessed
from the back of the unit
1
Water Tanks must be
removed to access
5
HOW TO FILL
TIMER
+
HUMIDISTATMIST
O
P
E
N
C
L
O
S
E
O
P
E
N
C
L
O
S
E
CAUTION: Before filling unit with water, turn the power off and unplug the unit from the outlet. NOTE: Always use two hands to carry the water tank.
1. Grasp tank handle and lift up from humidifier base.
2. Turn the tank upside down—remove the tank cap by turning it counter-clockwise.
3. Fill the water tanks with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area. Never add
essential oils into the water tank. Even a few drops will damage the unit. See page 9 for aroma instructions.
+
4. Replace the tank cap by turning clockwise until tight.
5. Install the tank back on the base of the unit. Make sure the tank is
6. Your humidifier is ready for use.
firmly seated.
6
HOW TO USE
Display shows: Programmed Humidity Setting (pictured), Timer Setting, Warm or Cool Mist Selection, and Mist Output Level
Programmable Humidistat
Mist Temperature
Programmable Humidistat Setting
Mist Output Level
Timer
Night Light / Display Light
Power ON/OFF Button
POWER ON/OFF BUTTON
Plug unit in to a 120 volt AC electrical outlet. Press the POWER button to turn unit on.
MIST OUTPUT LEVEL
Mist adjusts from the lowest output 1 to the highest output 5. To increase the mist output, press the + Button. The corresponding Mist Level will be lit on the display. To decrease mist output, press the – Button.
MIST TEMPERATURE SETTING
To change the mist temperature from Cool to Warm Mist, press the Mist Temperature Button. WARM will be illuminated on the display. To change the mist temperature from Warm to Cool Mist, press the Mist Temperature Button again. COOL will be illuminated on the display.
NOTE: Once Warm Mist is selected, it will take approximately 20 minutes to heat up before the mist becomes warm.
7
HOW TO USE
PROGRAMMABLE HUMIDISTAT
The Programmable Humidistat can be set in 5% increments from 35% - 60% humidity. To program the humidity level, press the Humidistat Button. Then press the + / - Button. The humidity
level will increase / decrease by 5% every time the + / - Button is pressed and will show on the display screen. Keep pressing the + / - Button until the desired programmable humidity setting is reached. The display will show the set humidity level for 5 seconds, then default back to display the mist output level.
NOTE: To eliminate any programmed Humidistat setting, press the Humidistat Button. Then press the + Button until you reach “CO” (continuous on) one level above 60%.
NOTE: When the set humidity level is reached, the humidifier will cycle off until the humidity in the room drops 5% below the set humidity level, then will cycle on until the set humidity level is reached again.
NIGHT LIGHT / DISPLAY LIGHT
Press the Night Light / Display Light Button once to turn on the night light. The light at the bottom of the water tanks will turn on, illuminating the tanks. Press a second time to leave the night light on, but turn off the display light. Press a third time to turn off the night light and display light so no lights are illuminating. Press a fourth time to turn the display light on.
TIMER
Press the Timer Button. Keep pressing the Timer Button until the desired timer setting is lit on the display. The Timer Button will cycle through the following settings 0 hours, 2 hours, 4 hours, 8 hours, 12 hours, 0 hours. To turn the Timer off, press the Timer Button until 0 hours is shown on the display.
NOTE: Always be sure the humidifier has a full tank of water prior to using the timer setting.
AUTO-OFF
When the water in the tank is almost empty, the humidifying function will power off to indicate to the user to refill the tank.
NOTE: It is normal to have a small amount of water in the base during and after use.
AROMA CAPABLE
The aroma feature will function automatically when the mist is turned ON.
8
HOW TO USE
AROMA
Choose from 2 included oil samples, or your favorite essential oil to deliver aroma into the air.
NOTE: For use with the Included HoMedics Aroma Pads only. NOTE: Do not leave a filled Aroma Pad in the Essential Oil Tray of the humidifier if it will be out of use for
a long period of time.
1. To open the essential oil tray on the lower back panel of the humidifier, press the spring loaded tray. It will pop open, and you can remove the tray.
3. Add 5-7 drops of essential oil to the pad. Depending on your personal preference, you may add more or fewer drops of essential oil.
To purchase genuine HoMedics replacement aroma pads, Model # ARMH-PAD1-10PK, go to your retailer where you purchased your TotalComfort Ultrasonic Humidifier Warm & Cool Mist, or visit www.homedics.com.
To purchase genuine HoMedics essential oils, go to your retailer where you purchased your TotalComfort Ultrasonic Humidifier Warm & Cool Mist, or visit www.homedics.com.
2. Place 1 Aroma Pad into the matching slot in the essential oil tray
4. Place the essential oil tray back in its compartment and push to close. The aroma will start automatically when the mist is turned ON.
9
ABOUT WHITE DUST:
Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called “white dust.” The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.
HOW AND WHY TO USE DEMINERALIZATION CARTRIDGES:
The HoMedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier. The cartridge should be replaced every 30 – 40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace the cartridge when you notice an increase in white dust build-up. If white dust still forms around the humidifier after a new cartridge has been installed, consider using distilled water.
To purchase new demineralization cartridges, model # UHE-HDC4, go back to the retailer (where you purchased your humidifier), or visit www.homedics.com
If you live in an area with hard water, or use a water softener, we recommend using distilled water for better results from your humidifier. Never use water softening additives in your humidifier.
INSTALLATION INSTRUCTIONS
1. Remove demineralization cartridges from packaging and let them soak in water for 10 minutes.
2. Remove the tanks from humidifier base and turn them over.
3. Unscrew the tank caps by turning counter-clockwise.
4. Fill each tank with water as shown in the How to Fill section of the instructions included with your humidifier.
5. Add the soaked demineralization cartridge into each tank.
6. Replace the tank caps by turning clockwise.
7. Place the tanks back on the base.
Demineralization Cartridges
10
CLEANING AND CARE
TIMER
+
HUMIDISTATMIST
CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.
NOT FOR USE WITH ESSENTIAL OILS
COOL
% RH
+
TO CLEAN THE TANKS
Remove the water tanks from the humidifier base by lifting them from the main unit. Unscrew the tank caps and rinse inside the tanks with clean water.
Every Day: Empty and rinse each tank and tank cap before refilling. Every Week: To remove any scale or build up, use a 50/50 mixture of
white vinegar and lukewarm water to clean the inside of the tanks.
TO CLEAN THE ULTRASONIC MEMBRANE
Every Day: Empty, rinse and dry the ultrasonic membrane and the
reservoir before refilling. Every Week: Remove the transducer plate cover. Pour a 50/50
mixture of white vinegar and water on the surface of the ultrasonic membrane, then soak for five minutes. Brush clean with a soft-bristle brush (not included) and rinse. Replace transducer plate cover.
NEVER touch the ultrasonic membrane with your fingers as the natural oils in skin can damage the membrane.
NOTE: Never submerge the base in water or any liquid
TO CLEAN THE AROMA TRAY
Open the aroma tray and remove the aroma pad. Aroma pads should be changed when switching to a different essential oil scent. If continuing to use the same scent, set the aroma pad aside for reuse. Wipe down the inside of the aroma tray with a soft cloth. Place the aroma pad back in the tray and close.
NOTE: Leave the aroma pad out of the aroma tray when storing.
TO CLEAN THE SURFACE
Clean the surface of the unit with a clean damp soft cloth. Before Storing: Clean the Tanks, Reservoir, Tank Caps and the
Ultrasonic Membrane with a 50/50 mixture of white vinegar and water. Be sure to rinse and let all parts dry completely before storing. Clean the aroma tray with a soft cloth.
After Storing: Rinse the Tanks, Reservoir, Ultrasonic Membrane and Aroma Tray with water. Dry completely before filling. Only fill the tank just before operating.
11
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE SOLUTION
No Power/No Mist from Spout • Unit is not plugged in
• Plug unit in
• No power at unit
• Low water level
• The humidistat setting is lower than the current room humidity
Peculiar Odor • Unit is new
• If unit is in use, the odor may be a dirty tank or old tank water
Excessive Noise • Unit is not level
• Low water level
White Dust Accumulation • Hard water used
• Demineralization Cartridge needs replacement
• Press the Power Button to turn the unit on
• Check circuits and fuses or try a different outlet
• Refill the tank with water
• Reset the humidistat to a higher humidity level, or change the mist output to Continuous ON
• Open the water tank cap and keep it in a shady, cool place for 12 hours
• Empty the old water, clean the tank and fill with clean water
• Place unit on a flat, even surface
• Check the water level. Refill the tank if the water is low
• Use distilled water and a Demineralization Cartridge
• Replace Demineralization Cartridge
12
FCC DISCLAIMER
This product has been tested and complies with the requirements for Federal Communication Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other devices. If this product is found to interfere with another device, separate the other device and this product. Conduct only the user maintenance found in this instruction manual. Other maintenance and servicing may cause harmful interference and can void the required FCC compliance.
Caution: All servicing of this humidifier must be performed by authorized HoMedics service personnel only.
13
Loading...
+ 29 hidden pages