Homedics UHE-CM65 Instruction Manual

PLEASE TAKE A

MOMENT NOW

REGISTER YOUR PRODUCT AT:

www.homedics.com/register

Your valuable input regarding this product will help us create the products you will want in the future.

INSTRUCTION MANUAL AND WARRANTY INFORMATION

ONE YEAR LIMITED WARRANTY

UHE-CM65

IMPORTANT SAFETY INSTRUCTIONS

WHEN USING ELECTRICAL PRODUCTS, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING:

READ ALL INSTRUCTIONS BEFORE USING

DANGER – TO REDUCE THE RISK OF ELECTRIC SHOCK:

Always place humidifier on a firm, flat surface. A waterproof mat or pad is recommended for use under the humidifier. Never place it on a rug or carpet, or on a finished floor that may be damaged by exposure to water or moisture.

Always unplug the unit from the electrical outlet immediately after using and before cleaning.

DO NOT reach for a unit that has fallen into water. Unplug it immediately.

DO NOT place or store the unit where it can fall or be pulled into a tub or sink.

DO NOT place or drop into water or other liquids.

WARNING – TO REDUCE THE RISK OF BURNS, FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS:

Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by HoMedics; specifically any attachments not provided with this unit.

NEVER drop or insert any object into any opening.

DO NOT operate where aerosol (spray) products are being used, or where oxygen is being administered.

NEVER operate the appliance if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the appliance to a HoMedics Service Center for examination and repair.

Always unplug the unit when filling or moving the unit.

Ensure that your hands are dry when operating the controls or removing the plug.

Always hold the humidifier firmly with both hands when carrying a full tank of water.

DO NOT carry this unit by the power cord or use the power cord as a handle.

To disconnect, turn all controls to the “off” position, then remove the plug from the outlet.

DO NOT use outdoors. For indoor use only.

Caution: All servicing of this humidifier must be performed by authorized HoMedics service personnel only.

SAVE THESE INSTRUCTIONS

CAUTION – PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE OPERATING.

This product is intended for household use only.

Always keep the cord away from high temperature and fire.

Perform regular maintenance on the ultrasonic membrane.

Never use detergent to clean the ultrasonic membrane.

Never clean the ultrasonic membrane by scraping with a hard object.

Stop using this unit if there is an unusual noise or smell.

Never operate without water in the tank.

Only use water in the tank.

Never use any additive to the water.

Keep this unit out of reach of children. Do not allow children to use this unit without supervision.

2

3

UNIQUE FEATURES & SPECIFICATIONS

ULTRASONIC TECHNOLOGY

This humidifier uses ultrasonic high frequency technology to convert the water into 1–5 million super particles that are dispersed into the air evenly.

NIGHT LIGHT

A useful night light feature is included for your convenience.

AUTO SHUT-OFF PROTECTION

When the tank is empty the unit will shut off automatically.

CAPACITY

1.4 gallons - 5.29 liters

RUNTIME: UP TO 65 HOURS

Runtime is calculated based on using cool water and setting the mist level between the low and medium settings. Based on the natural humidity level in your home, the temperature of water you use, and the mist level setting you choose, you may experience longer or shorter run times.

TOTAL COMFORTHUMIDIFIER

Handle

Mist Spout

 

Water Tank

Ultrasonic Membrane

Tank Cap

Control Panel

CAUTION: This appliance has a polarized plug (one blade wider than the other). To reduce the risk of shock, this plug is intended to fit only one way in a polarized outlet. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician.

DO NOT attempt to defeat this safety feature. To do so could result in an electric shock hazard.

4

5

Homedics UHE-CM65 Instruction Manual

HOW TO FILL

CAUTION: Before filling unit with water, turn the power off and unplug the unit from the outlet. NOTE: Always use two hands to carry the water tank.

1.Grasp tank handle and lift up from humidifier base.

 

N

C

 

L

O

P

E

 

 

2.Turn the tank upside down—remove the tank cap by turning it counter-clockwise.

 

N

C

 

L

O

P

E

 

 

3.Fill the water tank with clean, cool (not cold) water. We recommend using distilled water if you live in a hard water area. Never add essential oils into the water tank. Even a few drops will damage the unit.

4. Replace the tank cap by

5. Install the tank back

6. Your humidifier is

turning clockwise until

on the base of the unit.

ready for use.

tight.

Make sure the tank is

 

 

firmly seated.

 

 

6

 

HOW TO USE

Night Light

ON/OFF Button

Mist Selection

Power/Mist Knob

POWER/MIST KNOB

MIST ADJUSTMENT SETTING

NIGHT LIGHT

 

 

Plug unit into a 120 volt AC

Mist adjusts from MINIMUM ( )

Press the NIGHT LIGHT (

)

electrical outlet. Turn the POWER/

mist to MAXIMUM ( ) mist. To

button to turn on the night

 

MIST ( ) knob clockwise to

increase the mist output, turn the

light. The light at the bottom

 

turn the humidifier on.

POWER/MIST knob clockwise. To

of the water tank will turn on,

 

decrease mist output, turn the

illuminating the tank. Press the

 

POWER/MIST knob counter-

NIGHT LIGHT (

) button again

 

clockwise.

to turn the night light off.

 

ATTENTION: When the water in the tank is almost empty, the humidifying function will power off to indicate to the user to refill the tank.

NOTE: It is normal to have a small amount of water in the base during and after use.

7

ABOUT WHITE DUST:

Use of high mineral content hard water may cause a white mineral residue to accumulate on surfaces in the room near the humidifier. The mineral residue is commonly called “white dust.” The higher the mineral content (or, the harder your water is), the greater the potential for white dust. The white dust is not caused by a defect in the humidifier. It is caused only by minerals suspended in the water.

HOW AND WHY TO USE DEMINERALIZATION CARTRIDGES:

The HoMedics demineralization cartridge will help reduce the potential for white dust, a deposit of minerals left behind from using hard water in your humidifier.

The cartridge should be replaced every 30 – 40 fillings. The cartridge may need to be replaced more often if you are using very hard water. Replace the cartridge when you notice an increase in white dust

build-up. If white dust still forms around the humidifier after a new cartridge has been installed, consider using distilled water. To purchase new demineralization cartridges, model # UHE-HDC4, go back to the retailer (where you purchased your humidifier), or visit (US) www.homedics.com, (CAN) www.homedics.ca

If you live in an area with hard water, or use a water softener, we recommend using distilled water for better results from your humidifier. Never use water softening additives in your humidifier.

INSTALLATION INSTRUCTIONS

1.Remove demineralization cartridge from packaging and let it soak in water for 10 minutes.

2.Remove the tank from humidifier base and turn it over.

3.Unscrew the tank cap by turning the cap counter-clockwise.

4.Fill the tank with water as shown in the How to Fill section of the instructions included with your humidifier.

5.Add the soaked demineralization cartridge into the tank.

6.Replace the tank cap by turning clockwise.

7.Place the tank back on the base.

Demineralization Cartridge

8

CLEANING AND CARE

CAUTION: Before cleaning the unit, turn power off and unplug unit from the outlet.

TO CLEAN THE TANK

Remove the water tank from the humidifier base by lifting it from the main unit. Unscrew the tank cap and rinse inside the tank with clean water.

Every Day: Empty, rinse and dry the tank, tank cap and water reservoir before refilling.

Every Week: To remove any scale or build up, use a 50/50 mixture of white vinegar and lukewarm water to clean the inside of the tank.

TO CLEAN THE ULTRASONIC MEMBRANE

Every Day: Empty, rinse and dry the ultrasonic membrane and the reservoir before refilling.

Every Week: Pour a 50/50 mixture of white vinegar and water on the surface of the ultrasonic membrane and in the reservoir, then soak for five minutes. Brush clean with a soft-bristle brush (not included) and rinse.

NEVER touch the ultrasonic membrane with your fingers as the natural oils in skin can damage the membrane.

NOTE: Never submerge the base in water or any liquid

TO CLEAN THE SURFACE

Clean the surface of the unit with a clean damp soft cloth as often as needed.

Before Storing: Clean the Tank, Tank Cap, Reservoir and the Ultrasonic Membrane with a 50/50 mixture of white vinegar and water. Be sure to rinse and let all parts dry completely before storing.

After Storing: Rinse the Tank, Tank Cap, Reservoir and Ultrasonic Membrane with water. Dry completely before filling. Only fill the tank just before operating.

9

TROUBLESHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

 

 

 

 

 

No Power/No Mist from Spout

Unit is not plugged in

Plug unit in

 

 

 

• Turn the Power/Mist knob

 

• No power at unit

 

clockwise to turn the

 

 

 

 

power on

 

Low water level

• Check circuits and fuses or

 

 

 

 

try a different outlet

 

 

 

• Refill the tank with water

 

 

 

 

Peculiar Odor

Unit is new

• Open the water tank cap and

 

 

 

 

keep it in a shady, cool place

 

• If unit is in use, the odor

 

for 12 hours

 

 

may be a dirty tank or old

• Empty the old water,

 

 

tank water

 

clean the tank and fill

 

 

 

 

with clean water

 

 

 

 

Excessive Noise

Unit is not level

• Place unit on a flat,

 

 

 

 

even surface

 

Low water level

• Check the water level. Refill

 

 

 

 

the tank if the water is low

 

 

 

 

White Dust Accumulation

Hard water used

• Use distilled water and a

 

 

 

 

Demineralization Cartridge

 

Demineralization Cartridge

Replace Demineralization

 

 

needs replacement

 

Cartridge

 

 

 

 

 

FCC STATEMENT

NOTE: This product has been tested and complies with the requirements for Federal Communication Commission, Part 18. Although this product is tested and complies with FCC, it may interfere with other devices. If this product is found to interfere with another device, separate the other device and this product. Conduct only the user maintenance found in this instruction manual. Other maintenance and servicing may cause harmful interference and can void the required FCC compliance.

Industry Canada ICES-001 Compliance Label: CAN ICES-1/NMB-1

Caution: All servicing of this humidifier must be performed by authorized HoMedics service personnel only.

10

11

Loading...
+ 13 hidden pages