HoMedics Tanda Clear+ Instructions For Use Manual

instructions for use
Thank You…
for purchasing the new Clear+ device. Clear+ is the rst and only device to combine powerful bacteria-killing blue light with sonic vibration and gentle warming for clinically proven clearing results. Together, these three technologies deliver unsurpassed speed and effectiveness for calm, clear, beautiful skin.
For important information about safety and how to use the device, read the full Instructions for Use booklet.
Customer service contact:
HoMedics Group Ltd, Somerhill Business Park, Five Oak Green Road, Tonbridge, Kent TN11 0GP, UK email tandaservice@homedics.co.uk
homedics.co.uk
1
Contents
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
What is the device used for? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Contraindications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Risks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Benets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
About acne . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Charging the battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Clear+ controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
How to use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
What to expect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Eye safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Device maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Travel tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Guarantee information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
TANDA
2
Package contents:
Clear+ Treatment Head (1)
Clear+ cordless rechargeable handpiece (2)
Recharging stand (3)
Power supply
Goggles
Components:
Plastic plug (to hold charge) (4)
Orange power button (5)
Indicator light (6)
1
6
5
2
3
4
homedics.co.uk
3
What is the device used for?
Clear+ is for the treatment of mild to moderate inammatory acne.
Is Clear+ right for you?
Acne type Description of condition Is Clear+ right for you?
Mild Acne Several inamed spots – red in colour
Less than 20 whiteheads, or less than 15
inammatory red spots or less than 30 total spots, not all inamed
Yes
Moderate Acne Any inamed spots (red in colour) and pustules
(visible accumulation of pus in skin)
20 to 100 whiteheads, or 15 to 50 inammatory
spots, or 30 to 125 total spots, not all inamed
Yes
Severe Nodular Acne
Inamed spots and pustules (visible accumulation
of pus in skin) with a few deep nodular lesions (solid mass can be felt under skin – can sometimes be raised)
Greater than 5 cysts (solid mass of skin like a
knot, can be raised or felt under the skin), or total whitehead count greater than 100, or total inammatory count greater than 50, or greater than 125 total lesions
No, consult your dermatologist for the best prescribed treatment
Severe Cystic Acne
Many nodular cystic lesions (with signs of scarring) No, consult your
dermatologist for the best prescribed treatment
If “yes”, then review the Contraindications, Warning, and Precautions below to ensure that Clear+ is safe for you to use.
TANDA
4
Contraindications
Never use this device over any suspicious or cancerous lesion. Using the device over cancerous
or other type of lesion can result in delaying the best medical treatment. Typical characteristics of potentially cancerous lesions include:
Asymmetry: one half of the abnormal skin area is different than the other half
Borders: irregular borders
Colour: varies from one area to another with shades of tan, brown, or black (sometimes white,
red, blue)
Diameter: usually (but not always) larger than 6 mm in size (diameter of a pencil eraser)
Bleeding: Any skin growth that bleeds or will not heal
Do not use if you have a history of light triggered seizures.
It is recommended that you test a small less sensitive patch of skin (i.e., like your forearm).
Light sensitivity test
Follow these instructions to see if you are sensitive to light:
1. Press the orange power button.
2. Place the device on an area of the forearm (as in the
diagram to the right). Leave in contact for the full 3 minute treatment cycle.
3. Press the orange power button again to do another 3 minute
treatment on the same area of your inner arm.
4. Wait 24 hours. You should NOT experience any adverse
reaction during the next 24 hours.
An adverse reaction is pain or discomfort in the treatment areas or any prolonged skin redness.
homedics.co.uk
5
Warnings
Warning: Discontinue use if you encounter any discomfort or skin redness that lasts for more than
two hours. You may have sensitivity to light or another condition. Consult with your healthcare provider.
Warning: Do not use if you are pregnant or breastfeeding.
Warning: Do not use if you have experienced a migraine in the last two years.
Warning: Do not use over thyroid gland (neck area). It may result in stimulation of growth.
Warning: To reduce the risk of electric shock that may cause injury or death:
Always attach the AC power adapter to device rst, then into the outlet.
Do not place or store the device where it can fall or be pulled into a tub or sink.
Do not place in or drop into water or other liquid.
Keep away all electrical appliances (including the Clear+) from water (including bath
and shower). If the unit accidentally falls in water unplug immediately.
Keep the cord away from heated surfaces.
Never drop or insert any object into any openings on the device.
Use only the power adaptor provided with the Clear+.
Never operate this device if it has a damaged cord or plug, if it is not working properly,
if it has been dropped or damaged, or submerged in water. Return the device to HoMedics Service Centre for examination and repair.
Do not disassemble the device as this may cause unit damage, malfunction, electrical
shock, re or personal injury. There are no user-serviceable parts inside the unit.
Do not allow children to use the device unsupervised.
Warning: To prevent re or serious burns:
Turn off immediately, if the Clear+ begins to overheat.
Keep away from where ammable aerosol products are being used or where oxygen
is being administered.
Loading...
+ 15 hidden pages