the fastest way to permanent hair reduction
NB: If you feel discomfort, treat at a lower level. If tolerable, increase the elo- s setting for higher efficacy. NB: Do not use on sun burned or tanned skin, as tanning may influence the safety of the treatment. Wait until the sunburn or tan fades prior to performing a test patch on an inconspicuous area. Reexamine the area after 3 days to ensure no side effects have occurred.
NB: Do not tan 24 hours after me- treatment. NB: During treatment, DO NOT hold
the applicator tip still in one spot!
Important safety information
Please read all warnings and safety information in user manual before using me- .
Note: If you have an active tan do not use me- .
Preparation
1. Clean your skin and wipe the area with a
non-alcoholic wipe.
2. Shave hair in treated area or, if you use the shaver or epilator - trim hair that is longer than 10 mm (you may use the shaver cartridge).
Treatment
1. Press the power button to
turn the system on.
2. Select the elo- s level by pressing the button near the appropriate level based on the attached table.
3. Press the elo- s activation button.
4. Press the epilator/shaver activation button to
select desired speed (epilator and shaver are sold separately). Visit www.memyelos.com.
5. Ensure you are touching the two grip sensors.
6. Hold the applicator in a position ensuring full
contact of the RF delivery bars with the skin. Do not press, just gently touch the skin. System will start emitting elo- s pulses.
7. Use the system slowly and continuously gliding on the treatment area without stopping in one place. Try not to repeat treatment on the same spot for at least 10 seconds.
Treatable Skin Types
Skin Type 1 – Pale white skin
(always burns, does not tan)
elo- s
Level: High
Skin Type 2 – Fair skin (burns easily, rarely tans)
elo- s
Level: High
Skin Type 3 – Darker white skin (tans after initial sunburn)
elo- s
Level: High
Skin Type 4 – Light brown skin (burns minimally, tans easily)
elo- s
Level: Medium-to-High
Skin Type 5 – Brown skin (rarely burns, tans dark & easily)
elo- s
Level: Low-to-Medium
Skin Type 6 – Dark brown or black skin (never burns, dark tan):
Do not use the
me- system!
Quick Reference Guide
epilator and shaver cartridge
activation
When to use me
-
1. perform first 4 treatments every 2 weeks
2. after first 6 weeks, use me- as hair appears (up to 3 months between treatments)
When you have finished the treatment
1. Place the applicator in its cradle in the
base unit.
2. Turn off the me- device by pressing the power button on the base unit. The cooling vents will continue to work for 4 additional seconds after the elo- s is turned off.
3. Gently rinse your skin with lukewarm water and pat dry.
4. Gently apply moisturizing cream or gel aloe vera to your skin (if epilator was used, it is recommended to apply just aloe vera).
1 minute per
underarm
3 minutes
per arm
10 minutes
per full leg
2 minutes
bikini area
Treatment durations:
For effective results, me- should be used
according to the following timings.
elo
-
s
activation
button
grip sensorsRF delivery bars
Table of contents
Detachable Quick Reference Guide About the me- hair removal system ________________________________ 6 Box contents _________________________________________________ 6 Important safety information _____________________________________ 7 System description ____________________________________________ 10 How to prepare the me- system for operation _______________________ 12 System preparation ____________________________________________ 14 Recommended elo- s levels ______________________________________ 16 How to operate the me- system ___________________________________ 17 me- treatment procedure ________________________________________ 21 When to use me- _____________________________________________ 22 How to replace your elo- s cartridge _______________________________ 24 Troubleshooting _______________________________________________ 25 Specifications ________________________________________________ 26 Labels and symbols ____________________________________________ 27
EN
6
About the me- hair removal system
Your new me- system is intended for long-term hair removal. The me- system is easy to use without assistance, and in the convenience of your own home. The system is intended for both women and men with Fitzpatrick skin tones I-V (see page 16 to evaluate whether your skin type can be treated). The system is designed for the removal of hair from all body parts below the neck. The me- system is powered by elo- s (Electro-Optical Synergy), clinically proven, gold standard technology that uses low­energy pulsed light together with gentle radio frequency (RF).
NB: Hair reduction results may be subject to variation.
Please read this entire user guide and watch the instructional DVD (included) before using the system for the first time. It is recommended to keep the guide in a safe place for future referrals and to re-familiarise yourself with this user guide prior to each use of me- .
Box contents
Upon opening the me- package you will find the following components:
Base unit and applicator, including:
elo- s cartridge and epilator/shaver
protective cap (already attached)
Accessories kit, including:
elo- s protective cap Electrical power cord Cleaning brush
User guide (including a quick
reference guide)
Instructional DVD Warranty card
Additional accessories (sold separately): Epilator with cleaning brush Shaver with cleaning brush elo- s replacement cartridge Facial kit (includes sperate instructions for use and user’s eye protection).
Visit www.memyelos.com
EN
7
Important safety information
Please read all warnings and safety information before using the me- system. Always follow basic safety precautions when using any electrical product. The system is designed for domestic use only.
Warnings
The system is designed for the removal
of human body hair. Any other use is expressly prohibited; DO NOT use the system for removal of hair on your face or head. Facial hair should only be removed using the facial kit that includes sperate instructions for use and user’s eye
protection. Visit www.memyelos.com.
DO NOT use the me- system
over tattoos or permanent makeup.
During treatment, DO NOT hold the applicator tip still in one spot! This might cause extensive heat build-up and
possible skin damage.
NEVER immerse the system or the applicator tip in water or any other liquid. DO NOT rinse any components of
the system with any kind of liquid.
DO NOT use the system where it can fall or be pulled into water. If device is dropped in water, unplug it immediately. DO NOT remove the device from water until unplugged. DO NOT use the device
again. Contact customer service centre.
If dropped or damaged, DO NOT
use the system.
Always disconnect the power cord from
the wall electrical outlet after use.
DO NOT use the system if any of its
components show signs of damage.
DO NOT open the system’s enclosure
under any circumstances.
DO NOT operate the device with a
cracked or broken glass window on the
elo- s cartridge.
To avoid accidents, keep the system away from the hair on your head, face, and also from clothes, brushes, wires,
cords, laces, etc.
DO NOT use the system on children or allow children to use this device. Keep the system out of the reach of children. Adult supervision is recommended for
teenagers under the age of 18.
DO NOT use the system if you have limited physical, sensory or mental capabilities. This does not apply to the latter if they were instructed in the use of the system or if they use it under the supervision of a person responsible for
safety.
Complete power shutdown will be achieved only when the power cord is unplugged.
EN
8
When NOT to use the me- system
You should NOT use the me- system if any of the following items apply to you:
If your skin type is darker than skin type
5 (see page 16).
If within the last three days you have
had a long skin exposure to the sun,or
if you have excessively tanned skin from sun, tanning beds or tanning creams within the last two weeks, as tanning may
influence the safety of the treatment.
If you have a pacemaker or internal
defibrillator.
If you have superficial metal or other
implants in the desired treatment area.
If you have a history of any type of
cancer, or pre-malignant moles.
If you suffer from severe conditions,
such as cardiac disorders.
If you have varicose veins in the
treatment area.
If you have moles, large freckles, darker
pigmented areas, scars or birthmarks
do not treat over them. If you are pregnant or nursing. If you have an impaired immune
system due to immunosuppressive diseases such as AIDS and HIV, or use of
immunosuppressive medications. If you have endocrine disorders, such as
Diabetes or Polycystic Ovary Syndrome.
If you have any active condition in the
treatment
area, such as sores, psoriasis,
eczema, burns, herpes simplex, wounds
or a rash.
If you have a history of skin disorders,
abnormal wound healing, as well as very
dry and fragile skin.
If you have a history of bleeding
coagulopathies, or use of anticoagulants.
If you are using medications, herbs, food supplements, and vitamins known to induce photosensitivity to light exposure at the wavelength used, such as Isotretinoin (Accutane) and/or topical retinoids within the last six months, Tetracyclines, or St.
John's Wort within the last two weeks.
If you are using medications that may
stimulate hair growth, such as Minoxidil.
If you have had any surgical procedure in the treatment area within the last three
months or before complete healing. If you have Epilepsy. If you have applied any type of anesthetics.
If you are on gold therapy
NB: If you are taking any medication, please consult with your doctor before using me- .
EN
9
Possible side effects
Removing hair can cause redness or irritation of the skin. This is a normal reaction and only lasts a short time.
NB: If sensitivity of area persists longer than 24 hours, consult your doctor.
Improper use of the me- system could result in possible side effects. Although these effects are rare and expected to clear within a short time, it is important to understand that every cosmetic treatment may involve some degree of risk, and that you understand and accept the risks and possible complications that can occur with pulsed light combined with RF hair removal systems. Side effects may include redness or swelling and colour changes to your skin. This may appear either at the time of treatment or shortly after.
NB: If unusual pain occurs, you should stop treatment. If you encounter any severe side effects, consult your doctor.
1. This device is not intended for use by individuals (including children) whose physical, sensory or mental capacities are reduced or who have no experience with the device or do not know how to use it, unless they are supervised or have received prior instructions from a person in charge of their safety.
2. Children should be supervised to ensure they do not play with the device.
3. The devices should not be turned on via an outside timer or a separate remote control system.
4. WARNING: Keep appliance away from water.
EN
10
1
2
3
4
5,6
System description
Your me- system is designed to be easy to use and is easy to maintain. The system is comprised of the following components:
1. Base unit
2. Control panel
3. Applicator
4. elo- s cartridge
5. Epilator cartridge or
6. Shaver cartridge
NB: Epilator and Shaver are sold separetly. Visit www.memyelos.com
EN
11
The treatment is done using the elo- s cartridge and if you like, you simultaneously use the epilator or shaver cartridges (Sold separately):
1. elo
-
s cartridge
Intense pulsed light (IPL) output window. Radiofrequency (RF) delivery bars.
2. Epilator cartridge
Rotating epilating mechanism.
3. Shaver cartridge
Foil covered shaver combined with a trimmer.
1
2 3
EN
12
bottom side
epilator or shaver
cartridge
top side
elo
-
s cartridge
How to prepare the me- system for operation
The me- system is easy to use and easy to care for. Your new me- system has the elo- s cartridge and epilator protective cap already connected to the applicator.
1. If you want to use the epilator or shaver - you should remove the protective cap, press the two blue buttons to slide
one cartridge out and insert the other one in its place. Slide the new cartridge into the applicator until you feel it "click" into place.
NB The elo- s cartridge is not interchangeable with the epilator or shaver cartridges.
Before use, make sure that the RF delivery bars and the light output window on the elo- s cartridge are clean (these may be cleaned using a soft tissue or non­alcoholic wet wipes).
NB: Epilator and Shaver are sold separately. Visit www.memyelos.com
EN
13
Cap
NB: The system can be operated just
with the elo- s cartridge (shaver/epilator protective cap must be attached to applicator’s opposite side).
NB: The system can be operated just with the shaver or epilator cartridge (protective cap must be attached to applicator’s opposite side).
EN
14
System preparation
The following illustrations display the base unit’s control panel and the applicator, and the following pages will explain how to prepare the system for use.
Getting familiar with me-’s control panel
Getting familiar with me-’s applicator
shaver / epilator activation
indicators
epilator or shaver activation
button
cooling inlet
epilator or shaver
cartridge
grip sensors
cartridge release
buttons
elo
-
s cartridge
elo
-
s cartridge
release buttons
epilator or shaver cartridge release
button
elo
-
s
activation
button
elo
-
s
activation
indicator
EN
15
2. Before turning on the system, the applicator must be placed in the cradle. Press the power button to turn the system on; the elo- s system indicators will flash for several seconds, then the indicator next to the power button will turn green. Now the system is ready for use.
3. Select the elo- s level you want to use by pressing the appropriate elo- s Level button: High, Medium or Low; the active level will illuminate a white indicator light. (Refer to the chart on page 16 of the user guide to set the right level for your skin type).
4. The elo- s cartridge is pre-loaded with a set number of pulses for your use; the counter starts at 100% and decreases as you use it. The amount of pulses remaining in the cartridge is indicated by the lights on the panel, as shown. Once the elo- s cartridge reaches 5% of its capacity, a red light will start blinking, and at 0%, the red light will remain constant, indicating that the cartridge must be replaced and responsibly disposed of. (Please refer to the WEEE explanation on page 27).
1. Connect the power cable into the system and then into the wall electrical outlet. An orange indicator will appear next to the power button.
EN
16
NB: If you have an excessive tan DO NOT use me- .
Treatable Skin Tones *
Skin Type 1 – Pale white skin (always burns, does not tan) elo- s
Level: High
Skin Type 2 – Fair skin (burns easily, rarely tans) elo- s
Level: High
Skin Type 3 – Darker white skin (tans after initial sunburn)
elo- s
Level: High
Skin Type 4 – Light brown skin (burns minimally, tans easily) elo- s
Level: Medium-to-High
Skin Type 5 – Brown skin (rarely burns, tans dark & easily) elo- s
Level: Low-to-Medium
Skin Type 6 – Dark brown or black skin (never burns, dark tan):
Do not use the
me- system!
Recommended levels
Determine your skin type based on the descriptions below and set your me- system's elo- s level accordingly.
If using the recommended elo- s level causes discomfort, treat at a lower level. If comfortable, increase the elo- s level for higher efficacy.
*For facial hair removal be sure to refer to the Treatable Facial Skin Tones Table attached to the kit. Visit www.memyelos.com
EN
17
grip sensors
RF delivery bars
elo
-
s activation
button
How to operate the me- system
Preparation
Your skin should be clean before starting the treatment. There should be no lotion, make-up, perfume, powder or bath/shower oil present on the skin in the area to be treated. Before treatment, wipe the area with a non-alcoholic wipe. You can choose one of two options:
1. Use with either the epilator or shaver accessory (sold separately) simultaneously during treatment with elo- s. In this case, there is no need for
shaving prior to treatment. NB: You can use the epilator or shaver if you have hair up to 10 mm.
2. If you do not use the shaver or epilator
accessories, you should shave the
required area prior to the elo- s treatment. NB: to ensure best results, you should not remove hair by waxing or epilator more than 5 minutes prior to elo- s treatment. Best results are achieved when the epilator or shaver accessories are used simultaneously with elo- s.
EN
18
epilator and shaver cartridge
activation
Treating with epilator or shaver cartridge (optional)
if you choose not to use the epilator/shaver - you must insert the epilator protective cap (provided) to allow system operation.
1. After you have chosen your desired elos level and activated the elo- s cartridge: Press the epilator/shaver cartridge activation button once to run the epilator mechanism at low speed; the number 1 indicator will light up. If desired, press it again to run the epilator mechanism at high speed; the number 2 indicator will light up.
NB:
The shaver cartridge (under foil cover) operates only at speed 1. In case you prefer not to use the epilator or shaver, make sure their protective cap is
attached to the applicator to allow elos cartridge operation
EN
19
NB: It is essential to watch the instructional DVD before using the system for the first time. NB: It is recommeded to use the system in an area with good natural light or in a well lit environment.
NB: When using the device on difficult to treat areas (eg. underarm) work the area in 2 directions at a 90 degree angle, for full coverage. Hard-to-reach areas can also be treated by first using either the shaver or epilator, using the protective cap in place of the elo- s cartridge, followed by the application of elo- s (while placing the protective cap on the shaver/epilator side). Shaver and epilator attachments sold separately.
NB: The first time you use the system with the epilator cartridge, it may feel slightly uncomfortable, as you are removing hairs from the follicles. This feeling subsides after a few treatments, even if you have sensitive skin.
NB: It is not recommended and there is no need, to look directly at the light flashes.
2. With the thumb and forefinger of your hand, lightly touch the two metal grip sensors, one on each side of the applicator.
3. Apply the tip of the applicator on your skin so that the two RF delivery bars are in complete contact with the skin.
4. Once full contact is achieved, you will notice light flashes, indicating that the system is operating. The elo- s activation button will automatically turn itself off if no pulses have been emitted for one continuous minute.
5. Use the system as you would use an epilator/shaver by continuously gliding on the treated area.
6. Move the applicator slowly and continuously without stopping in one place so that the light flashes will follow each other and cover the entire area. Try not to repetitively go over the same spot for at least 10 seconds.
DO NOT hold the device in one spot. DO NOT treat the face. Facial hair should only be removed using the facial kit that includes dedicated instructions for use and user’s eye protection. Visit www.memyelos.com
EN
20
Important Note! Do not block or cover the applicator's cooling inlet during operation to avoid overheating of the applicator.
cooling inlet
hot air
outlet
Please be warned hot air will come out of the hot air outlet once the system is in use.
correct incorrect
Important Note! The elo- s cartridge
will not operate unless both RF delivery bars are in contact with the skin, and you are touching both grip sensors on the applicator.
skin surfaceskin surface
both RF
delivery bars
are in contact
with the skin
EN
21
me- treatment procedure
choosing your configuration:
HoMedics recommends that you integrate your tried-and-tested hair removing habits with your new me- system:
If you are used to using a razor ­ you can shave the treated area before using the elo- s cartridge only. Maintain the time of treatment and protocol as
illustrated.
If you are used to using an electric
shaver, you can now use the me- system with the and shaver cartridges.
If you are used to using an epilator, you can now use the system with the
elo- s and epilator cartridges.
If you are used to any combination of shaving or epilating in different areas of your body, use the me- system in the same method. When treating light hair, it is recommended to use the elo- s+epilator combination for higher
efficacy.
Treatment durations:
For effective results, me- should be used for approximately the amount of time indicated for each body area.
1 minute per underarm
2 minutes bikini area
3 minutes per arm
10 minutes per full leg
Treatable skin types
DO NOT USE
EN
22
NB:
Treatment intervals refer to the use of the
elo- s cartridge only. For maximum safety, it is not recommend to use the elo- s cartridge more than once every two weeks.
Results may vary depending on treatment
area, hair type, skin type etc.
When you have finished the treatment
1. Place the applicator in its cradle in the base unit
2. Turn off the me- device by pressing the power button on the base unit. The cooling vents will continue to work for 4 additional seconds after the elo- s is turned off.
3. Gently rinse your skin with lukewarm water and pat dry.
4. Gently apply moisturizing cream or gel aloe vera to your skin ( if epilator was used, it is recommended to apply just aloe vera).
When to use me
-
1. perform first 4 treatments every 2 weeks
2. after first 6 weeks, use me as hair appears (up to 3 months between treatments)
EN
23
When you are done
Unplug the system from the electrical
wall outlet.
Unless elo- s cartridge is empty, do not remove it from the applicator. If you remove the cartridge, insert the elo- s
protective cap in place.
If applicable, clean the epilator/shaver
cartridge with the cleaning brush (supplied). It is recommended to clean also with soft tissue or non-alcoholic wet wipes.
Wipe off the applicator, and the glass window of the elo- s cartridge in particular, with soft tissue or non-alcoholic
wet wipes. Store the applicator back in the base unit. Store system away from the reach
of children.
Warning: do not rinse any part of the system with water. NB: Do not use any cleaning agents to clean the me- device and/or its accessories.
Cleaning the shaver cartridge
1. Turn the system off and unplug the
electrical power cable from the wall socket.
2. Remove the shaver cartridge by pressing the release buttons, and sliding it off the applicator.
3. Remove the foil-covered blade assembly from the shaver cartridge by pulling it out.
4. Use the supplied cleaning brush to clean the blade assembly. It is recommended to clean also with soft tissue or non-alcoholic wet wipes.
5. Clean the bottom of the shaver cartridge with the cleaning brush supplied.
6. Insert the blade foil into the shaver cartridge again.
7. Put the shaver cartridge back on again. Push down the shaving head until it catches.
Sold separately. Visit www.memyelos.com
EN
24
NB: New elo- s cartridges are available at www.memyelos.com
How to replace your cartridge
1. Make sure that the me- device
is turned off.
2. Remove the old elo- s cartridge from the applicator by pressing the 2 release buttons on its side and gently pulling it out.
3. Take the new elo- s cartridge out of its protective container (avoid touching the lens). Slide the cartridge gently into the applicator until you feel it "click" into place.
4. Before turning on the system, the applicator must be placed in the cradle. Turn on the me- device. A new elo- s cartridge will show 100% on the panel.
5. Turn on the by pressing the elo- s button on the side of your applicator. Make sure that the indicator on the applicator is on and is not blinking.
6. Your me- device is ready for use.
NEW
USED
EN
25
Troubleshooting
Here is what you should do if any problems arise with your system: If the me- system will not start:
The green indicator next to the power button should be on. If the indicator is orange, this means that the system is turned off. Press the power button to turn
the system on. Check the system's power cable; it should be connected to the system and to
the wall outlet.
If light pulses are not emitted from the
cartridge:
Make sure that both sides of the
applicator have a cartridge or a
protective cap well inserted. The white elo- s indicator on the applicator should be continuously illuminated. A flashing white indicator means that the elo- s cartridge or
epilator/shaver cartridge or epilator/
shaver cap is not inserted correctly.
Re-insert the cartridge/cap.
The elo- s cartridge display on the base
unit's control panel should show an indicator next to any of the percentage values (100%, 80%, etc.) or a blinking red light next to the empty indicator. If the red Empty indicator is continuously lit, it is
time to insert a new cartridge.
During treatment, make sure that the
RF delivery bars are in contact with your
skin and that you are touching the grip
sensors on the sides of the applicator.
Make sure that the Error indicator
above the power button) is not)
illuminated. If it is: Turn the system off. Unplug it from the wall electrical outlet. Wait 1 minute. Reconnect the power cable to the
electrical outlet.
Turn the system back on.
If none of these suggested measures seem to help, contact your local provider for support.