Service Manual for the Lang Kit: SKXLH740-1,
Model:
CSE12 & CSE12-ACD
CSE12-1 & CSE12-208VCD
Star Manufacturing International 10 Sunnen Drive St. Louis, MO 63143 Part #: 2M-W368 Phone: 314-781-2777 Fax: 314-781-2714 Rev. - www.star-mfg.com December 8, 2006
CONTENTS OF KIT
WIRING DETAIL
2 Rev. - 2006
INSTRUCTIONS FOR INSTALLATION
7
- Remove 4 screws indicated in illustration 1 & 2 to remove hood cover. WARNING: With the hood cover removed the CSE12 unit will NOT be held in the down position.
-Remove 2 screws shown in illustration 3. Ensure that numbers on wires to existing mechanical switch are legible. If not legible, renumber as indicated in illustration 4. Disconnect wires from mechanical switch.
-Cut the connectors from the switch wires as shown in illustration 5 and strip each wire 3/8”. Install mercury hood switch assembly with the two screws removed in previous step per illustration 6.
-Wire nut wires from the mercury hood switch assembly to corresponding existing wires as shown in illustration 7. Tuck the wires and wire-nuts into the switch box as shown in illustration 8.
Illustration 1 Illustration 2
Illustration 4Illustration 3
Illustration 6Illustration 5
Illustration
Illustration8
-Replace hood cover.
3 Rev. - 2006