Hobart WAREWASH AMPERE RATINGS, WASTE AMPERE RATINGS General Manual

Page 1
Item # ________________________________
Quantity _______________________________
C.S.I. Section 11400
WAREWASH/WASTE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
MANUALLY FED
MACHINE HP 120/208(3W)/ 120/240(3W)/
LX18, 18C LX18H LX30 LX30C, 40C, GC LX30H, 40H, GH &
LX30C w/Booster
AM14T, 14TC & 14F
(5000W)
AM14T, 14TC & 14F 2 26.1 15.3 10.5 6.8
MODEL HP VOLT/HZ/PH AMP COMMENT
SM6T2
UW-50 5 Steam 20.3 17.6 9.2
120/60/1 208/60/1 240/60/1
3
⁄4 13.3 7.6 7.6 N/A N/A 13.9 7.9
3
⁄4 N/A 41.3 36.8 41.3 36.8 N/A 37.1
3
⁄4 14.4 14.8 13.9 14.8 13.9 13.9 14.2
3
⁄4 15.3 14.8 13.9 14.8 13.9 13.9 14.2
3
⁄4 N/A 43.6 38.9 43.6 38.9 N/A 39.2
(Electric Heat - connection included)
HP
2 67.4 44.9 26.8 13.5
HP
1
⁄2 120/60/1 6.0 Separate 1KW electric heat connection
HP HEAT 208V 240V 480V
120V 208-240V 208-240V 480V
120V 208-240V 208-240V 480V
ALL SINGLE POINT ELECTRICAL CONNECTION
Electric-10KW/Booster-14KW 89.2 79.9 40.4
Gas/Electric Booster-14KW 60.3 52.3 26.4
1 PHASE 3 PHASE
(Steam or Gas Heat)
1 PHASE 3 PHASE
Electric-10KW 50.3 46.2 23.5
Gas 21.4 18.6 9.6
60/1 60/1
AMPERE RATINGS
1 PHASE
100/50/1 220-240/50/1
F-7984 – Warewash/Waste Ampere Ratings Page 1 of 4
Page 2
WAREWASH/WASTE AMPERE RATINGS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
RACK CONVEYOR (C-LINE-A)
MODEL HP (MOTOR)
1
C-44A, C-44AW, C-54A, C-44B, C-44BW
CRS-66A, CRS-66AW, CCS-66A CCS-66AW, CRS-76A, CCS-76A
⁄6 Conveyor
2 Wash
1
⁄6 Conveyor 2 Wash 22.1 14.5 8.4 7.4 1 Prewash
1
⁄6 Conveyor
1 PHASE 208-240V 208-240V 480V 600V
15.5 11.1 6.8 5.9
3 PHASE
2 Wash 22.1 14.5 8.4 7.4
CPW80A, CPW-80AW, CPW-90A
1 Prewash
1
⁄6 Conveyor 2 Wash 24.6 16.8 9.4 8.3 2 Prewash
1
⁄6 Conveyor
C-64A, C-88A, C-64W, C-88W 2 Wash 24.6 16.8 9.4 8.3
2 Rinse
1
CRS-86A, CCS-86A, CRS-110A, CCS-110A 2 Wash CRS-86W, CCS-86W, CRS-110W, CCS-110W 2 Rinse
⁄6 Conveyor
31.2 20.2 11.0 9.5
1 Prewash
1
⁄6 Conveyor
CPW-100A, CPW-124A, CPW-100W, CPW-124W
2 Wash 2 Rinse 1 Prewash
1
⁄6 Conveyor 2 Wash 2 Rinse
31.2 20.2 11.0 9.5
33.7 22.5 12.0 11.6
2 Prewash
* C-Line-A Blower/Dryer 2 Blower — 5.5 2.7 2.2 * C-Line-A Condenser
1
⁄2 Condenser 3.5 2.2 1.1 .7
* C-Line-W (Dual Rinse) 31.3 18.6 7.8 6.2
* This chart presents the machine nameplate total for the motor(s) and control by model. When ordered with electric heat, a separate service connection is required for the wash tank electric heater
and a separate service connection is required for the power rinse tank electric heater. Add to the machine nameplate current the rated current of the dryer and/or condenser(s) when these options are ordered. When the C-Line-W (Dual Rinse) is ordered, a separate service connection is required for the Dual Rinse section.
FASTRACK (FR, FRC, FRC-A) Contact factory for total ampere rating for these machines. Proposed system must be clearly defined for accurate ampere value.
FLIGHT TYPE (FT)
MODEL HP
208-240V 480V 600V
3 PHASE
FT900 91/2 29.9 17.5 14.8 FT900S 61/2 22.1 13.6 11.7 *FT900 DRYER 3 8.4 4.1 3.3
*Add dryer ampere ratings to 900 series for total ampere value.
Single phase motors are not available with any FT.
FT900 or FT900S are provided with a service connection for the motors and controls. Two additional service connections are provided for the two tanks when electric heat is specified. A separate service connection is also required when an electric blower dryer is specified. An electric booster requires a separate service connection when one is specified.
Page 2 of 4 F-7984 – Warewash/Waste Ampere Ratings
Page 3
WAREWASH/WASTE
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
CONVEYOR AND FLIGHT TYPE MOTOR RATINGS
MODEL (Motor) HP
C-Line Prewash 1 7.8 4.0 2.0
Wash 1
Power Rinse 2 11.3 5.5 2.7 Dryer 2 — 5.5 2.7
Prewash 3 7.8 3.9 3.1 Wash 3 7.8 3.9 3.1
FT900 Power Rinse 3 7.8 3.9 3.1
Conveyor Dryer 3 8.4 4.1 3.3 Feeders (Line voltage 1 phase) 3.0 3.0 3.0 Controls (115V Pilot Circuit) 1.5 1.5 .5
FT900S Prewash 3 7.8 3.9 3.1
Wash 3 7.8 3.9 3.1 Conveyor Dryer 3 8.4 4.1 3.3 Feeders (Line voltage 1 phase) 3.0 3.0 3.0 Controls (115V Pilot Circuit) 1.5 1.5 .5
1
1
/2 — 4.3 2.2
2—5.5 2.7
1
/2 9.5 4.5 2.3
2 11.3 5.4 2.7
1
/2 2.0 2.0 2.0
1
/2 2.0 2.0 2.0
AMPERE RATINGS
1 PHASE 3 PHASE
200-230V 200-230V 400-460V
208-240V 480V 600V
TANK HEAT - BOOSTERS - BLOWER DRYER
DISHWASHER ELECTRIC TANK HEATERS
Amperes for 5000 watt heater except AM-14 Amperes for 5000 watt heater AM-14 Amperes for 10,000 watt heater — 50.0 47.6 28.9 27.4 13.7 9.6 Amperes for 13,000 watt heater — — — 37.5 35.7 17.9 12.5
ELECTRIC BOOSTERS
Amperes for AM-14 10KW Frame Mounted Booster Amperes for 39KW Elec. Booster (FT) — — — 104.1 89.9 45.0 37.5 Amperes for 54KW Electric Booster (FR-FRC) Amperes for 58.5KW Electric Booster (FT)
ELECTRIC BLOWER-DRYERS
Amperes for Blower-Dryer 42KW (C-Line ‘A’, FR, FRC) Amperes for Blower-Dryer 20KW
(FT-800/FTM-800/800S/FT900/FT900S)
115V 200V 230V 200V 230V 460V 600V
— 25.0 23.8 14.4 13.7 6.9 4.8
41.7 25.0 28.8 14.4 16.6 6.9 4.8
— 48.0A 45.5A 27.7A 26.3A 13.1A 10.0
———156.1 124.4 62.2 51.9
———156.1 134.8 67.4 56.2
———121.1 105.4 52.7 40.4
———57.8 50.2 25.1 19.2
1 PHASE 3 PHASE
F-7984 – Warewash/Waste Ampere Ratings Page 3 of 4
Page 4
WAREWASH/WASTE AMPERE RATINGS
701 S Ridge Avenue, Troy, OH 45374
1-888-4HOBART • www.hobartcorp.com
DISPOSERS
MODEL HP
FD3-50 FD3-75
1
3
115V 200-230V 200V 230V 460V
/2 8.8 4.1 - 4.4 2.6 2.8 1.4 /4 10.8 5.5 - 5.4 3.1 3.0 1.5
1 PHASE 3 PHASE
FD3-125 11/4 15.0 9.3 - 7.5 4.5 4.2 2.1 FD3-150 11/2 — 200V - 10.0/230V - 8.7 5.8 5.0 2.5 FD3-200 2 — 200V - 12.0/230V - 10.8 7.4 6.4 3.2 FD3-300 3 — — 10.6 8.2 4.1 FD-500 5 — — 12.8 12.8 6.4
WASTE EQUIPMENT
3 PHASE TOTAL AMPERAGE DRAW
MODEL HP
WS800
3
⁄4 2.6 2.6 1.3
208V 240V 480V
WS1000 3 6.0 7.6 3.8
5 22.0 18.5 9.2
5 H.P. Pulper 17.6 15.0 7.5
WR1000 2 H.P. Slurry Pump 7.1 6.2 3.1
3 H.P. Slurry Pump 9.7 8.4 4.2
5 H.P. Slurry Pump 15.6 13.6 6.8 W738 3 H.P. Waterpress 10.2 9.0 4.5 W38 3 H.P. Waterpress 9.7 8.4 4.2 W59 5 H.P. Waterpress 15.6 13.6 6.8 Waterpress 2 H.P. 7.1 6.2 3.1
Return 3 H.P. 9.7 8.4 4.2 Pumps 5 H.P. 15.6 13.6 6.8 Water Recovery
1
⁄2 2.3 2.0 1.0
Pump
(Electric Heat - connection included)
HP
1 PHASE 3 PHASE 208-240V 208-240V 480V
TW (Turbowash)
2 20.2 17.4 8.7
(No Heat)
HP
1 PHASE 3 PHASE 208-240V 208-240V 480V
TW (Turbowash)
2 9.2 6.4 3.2
NOTE: For Turbowash with disposer option, see disposer section in this specification sheet for the additional amperage requirements. For systems with single point connection option, add Turbowash & disposer amps together. (Single point connection not available with 115V disposers).
RACK CONVEYOR
MODEL HP (MOTOR)
1
CMT-44
⁄10 Conveyor 2 Wash
1
⁄10 Conveyor
1 PHASE 3 PHASE 208-240V 208-240V 480V
13.1 9.7 6.1
CMT-66 2 Wash 22.2 15.4 8.7
1 Prewash
As continued product improvement is a policy of Hobart, specifications are subject to change without notice.
Page 4 of 4 F-7984 – Warewash/Waste Ampere Ratings
F-7984 (REV. 8/03) LITHO IN U.S.A. (H-01)
Printed On Recycled Paper