Chemical Family Hydrouorocarbon Aroma Slight, ethereal Boiling Point -26˚ C / -16˚ F Evaporation Rate Instant Vapor Pressure @ 20˚C 96 PSIA
These specications pertain to HFC-134a.
Health, Safety & Environmental Data
Toxicity Rating (ppm, 8-hr. TWA, TLV) 1000 Flashpoint (TCC) None Safety Rating Nonammable NFPA Health: 1; Fire: 0; Reactivity: 1 Primary Ingredient HFC-134a
(In Europe, these product instead feature an HFO Low GWP pro­pellant and have different performance, See PS-125 for details.)
Ozone Impact Zero Organic Content (g/L) MCC-FRZA 12 All others 0 RoHS and WEEE Compliant Yes F-Gas Compliant (In Europe only) Yes SNAP Approved Yes
Packaging
Micro•Freeze™ Circuit Chiller 284 g MCC-FRZ*† Micro•Freeze™ Anti-Stat 284 g MCC-FRZA* Micro•Blast™, High-Flo Valve 284 g MCC-DST Micro•Blast™, StatZap™ Valve 284 g MCC-DSTZ* Big•Blast™, High-Flo Valve 392 g MCC-AIR
Packaged in cases of twelve (12) cans per box. Shelf life is unlimited.
• Products tagged with an asterisk are StatZAP™ compatible. MicroCare strongly recommends the StatZAP™ dispenser, #MCC-ZAP, to minize damage from static charges.
† Products tagged with the dagger are available in two different packages, although the part numbers are identical. In Europe, those products are available only with the nonammable Zeus™ Low GWP Propellant, a MicroCare exclusive, and have safety labeling compliant with EU regulations. Outside of Europe, those two products use U.S. labeling and HFC-134a as the propellant. In either case, the quantity of propellant in the aerosols are identical.
Product Notes
AVAILABILITY. This product is available from MicroCare distributors world-wide. Contact your local distributor at www.MicroCare.com for details.
TRADEMARKS. “MicroCare” and the MicroCare logo are registered trademarks of MicroCare Corp. “Big•Blast”, “Micro•Blast”, “Micro•Freeze” and “StatZAP” are all trademarks of MicroCare Corp.
DISCLAIMER. The information set forth herein is based on data believed to be reliable, but MicroCare makes no warranties express or implied as to its accuracy and assumes no liability arising out of its use by others. This publication is not to be taken as a license to operate under, nor to infringe upon, any patents not herein expressly described.
Precision Dusters
All the MicroCare® precision duster products deliver clean, dry blasts of a compressed gas to hard-to-reach surfaces. They enable technicians to remove dry contamination like dust, lint and sand from circuit boards, precision mechanical devices and delicate substrates any type. Importantly, the cleaning is performned without touching the surfaces. Unlike solvent cleaning, which wets surfaces, these precision dusters are completely dry. These products are equipped with a high-ow valve which generates enormous “blasting power.” For static-sensitive applications, the unique, patented StatZAP™ ESD Eliminator from MicroCare can be used on the StatZAP-compatible versions of these products.
Freeze Sprays
All Micro•Freeze™ products deliver instant chilling of circuit boards and components. They exceed the mil specs of -40˚C/-40˚F and may chill to as low as -60˚C/-76˚F under optimal conditions. None will attack plastics or generate component-shattering thermal shock. The Anti-Stat Micro•Freeze includes a static-dissipative additive that evaporates in about sixty seconds.
Other Information
These products all feature HFC-134a as the propellant, which is the industry standard for nonammable propellants. This is noncorrosive, residue-free and plastic-safe. Unlike less expensive products, none of them are ammable which greatly enhances worker safety.
Special Safety Note: Some companies call their precision dusters by the term “canned air.” These products do not contain air and should not be used as a breathing apparatus.
MCC-FRZ PRODUCT SPEC PS-50 Rev. 8/20/2010 Replaces 11/25/2008 Page 1 of 1
MicroCare Corporation
595 John Downey Drive, New Britain, CT 06051 USA Tel: 860.827.0626 Fax: 860.827.8105 In North America, Dial: 800.638.0125 Email: TechSupport@MicroCare.com On the Web: www.MicroCare.com
MicroCare is
ISO 9001:2000
Registered
Technical Specification
Precision Dusters &
Freeze Sprays
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
The StatZAP™ ESD Eliminator
Kills Static; Saves PCBs and
Avoids Repairs
If your company is using precision dusters in static-sensitive environments, then the StatZAP™ ESD Eliminator is a tool you need.
Each StatZAP™ dissipates the dangerous static charges created by high-pressure aero­sols, keeping your components safe from dangerous ESD. Ordinary aerosol sprays create up to 12,000 volts of chip-killed ESD as the liquid or gas races down the plastic spray tube inside the aerosol can. Since volt­ages as low as 150 volts can cause ESD dam­age, the StatZAP ESD Eliminator is engi­neered to continuously drain these charges before they reach dangerous levels.
Other important features include:
• Noncorrosive stainless steel construc­tion for years of life.
• The comfortable knurled grip and the extra­long trigger activator minimize the potential for repetitive motion injuries.
• The angled tip can be rotated upward, making it easy to spray accurately in any direction.
• The ShockShield™ insulating sheath covers the tip of the StatZAP, protecting the board and the operator from accidentally touching an energized circuit.
MicroCare Corporation
595 John Downey Drive, New Britain, CT 06051 USA
Tel: 860.827.0626 Fax: 860.827.8105
In North America, Dial: 800.638.0125 Email: TechSupport@MicroCare.com
On the Web: www.MicroCare.com
Contact MicroCare Today and See
How Easy It Can Be to Avoid ESD Damage!
www.MicroCare.com
Documentation Provided By HMC Electronics
33 Springdale Ave. Canton, MA 02021
http://www.hmcelectronics.com
(800) 482-4440
Loading...