Hitachi SJ300-EL BROCHURE

VARIABLE FREQUENCY DRIVEVARIABLE FREQUENCY DRIVE
for ELEVATOR CONTROLfor ELEVATOR CONTROL
3phase 200V class: 0.4(1/2) - 55(75) kW(HP)
3phase 200V class: 0.4(1/2) - 55(75) kW(HP)
3phase 400V class: 0.75(1) - 150(200) kW(HP)
3phase 400V class: 0.75(1) - 150(200) kW(HP)
The SJ300-EL series variable frequency drive is specialized for the special requirements of elevator control.
Various functions such as vector control with a pulse generator, sigmoid acceleration/deceleration for each speed step, torque bias, etc. enable the SJ300-EL to solve demanding applications.
Sigmoid Curve for Elevator Control, Acceleration and Deceleration Time Settings for Multispeed
SJ300-EL features fully tunable Sigmoid ("S" letter) acceleration and deceleration function. Acceleration and deceleration start/end ratio and time are settable
independently for each multispeed step.
System Diagram
SJ300-EL
A
Output freq.
BD
Accel. time Decel. time
The SJ300-EL consists of the feedback expansion card and the frequency drive unit with application-specific software. A motor with a pulse generator is required for
SJ-FB (Feedback expansion card)
SJ300 (Unit with application-specific software)
vector control.
C
t
Hitachi Industrial Equipment Systems Co., Ltd.
Gain Adjustment
Inf
t
ioni
t
h
i
b
j
t
t
ith
t
i
A
mbien
t
t
e
m
p
p
erature
t
t
y
y
t
tAt
tvt
t
4
4
J
4
4
4
4
W
t
4
4
4
4
Variable ASR* gain setting function is available. Stable operation is obtained with high-gain setting at stopping or slow speed, low-gain at high-speed steady run. Settable up to eight points.
*ASR: Automatic Speed Regulator
100%
ASR gain [%]
f1f2f3f4f5f
6
8
frequency
Output
f7f
Torque Bias Function
The SJ300-EL controls starting torque with feedback signal from the load cell. For smoother elevator move!
SJ300-EL
wait
Brake
confirm
Flexible Brake Control Signal Setting
Flexible adjustment is available for brake control. Braking frequency and release frequency are independently settable.
Output frequency
Forward [FW]
Brake Release [BRK]
Brake Confirm [BOK]
Battery-backup for Power Failure (customized specification)
In case of power failure, the SJ300-EL can continue operation with battery or UPS. Please provide specifications of battery or UPS to Hitachi for review.
Emergency Control
In case of a malfunction of pulse generator, the SJ300-EL automatically changes control method from vector control to SLV or V/f and continues operation.
wait
Cargo
Acc. wait
IM
Load cell
PG
Counter weight
Delay
Brake
confirm
wait
Stop wait
Standard Specifications
Power source 3-phase 200-230V+/-10% or 380-480V +/-10%, 50/60Hz +/-5% Output frequency range 0.1-400Hz Control method Sine-wave pulse width modulation (PWM) control Starting torque 200(180)*% at 0.5Hz, 150% or at around 0Hz, 100% at 0Hz Overload capacity 150%, 60sec/ 200(180)*%, 0.5sec. Acc./decel. time 0.01-3,600sec. for each multispeed step Protective functions Over-current, overload, braking resistor overload, over-voltage, EEPROM error, under-voltage error, CT (Current
transformer) error, CPU error, external trip, USP error, ground fault, input over-voltage, instantaneous power failure, expansion card 1 error, expansion card 2 error, inverter thermal trip, phase failure detection, IGBT error, thermistor error
Dimensions [Unit: mm(inch)] (inches for reference only)
.
.
.
.
.
.
.
. Height 255(10.04) 260(10.24) 390(15.35) 540(21.26)*1 550(21.65)*2 700(27.56)*3 700(27.56) 740(29.13) Depth 140(5.51)
*2 170(6.69)*4 190(7.48)*4 195(7.68)*4 250(9.84)*4 250(9.84)*4 270(10.63)*4 270(10.63)*4
f
0.4
(kW)
(HP)
0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150*5
12357.5101520253040506075100125150175200
1/2
200V class 400V class
*75kW or greater *1:Add 100mm(3.94in.) for conduit box *2: Add 80mm(3.15in.) for conduit box *3: Add 70mm(2.76in.) for conduit box *4:Add 8.5mm(0.33in.) for potentiometer *5:UL Version only, rated current is same as 132kW.
orma
n
sbrochureissu
ec
ochange w
outno
ce.
SIG-056 2003.12
Loading...