Hitachi RAS-S10CY, RAS-5115CY, RAS-S13CY, RAC-S10CY, RAC-5115CY Installation Manual

...
2,300mm or more
700
6
4
3
5
Screw for Mounting Plate
(4.1x32)
HITACHI SPLIT-UNIT AIR CONDITIONER
INSTALLATION MANUAL
+ – Screwdriver ● Measuring Tape ● Knife
Saw ● ø 65mm Power Drill ● Allen Key ( 4mm)
Wrench (14, 17, 19, 22mm)
Gas Leakage Detector ● Pipe Cutter
Plastic Tape ● Pliers ● Flare Tool
Carefully read through the procedures of proper installation before starting installation work.
The sales agent should inform customers regarding the correct operation of installation.
Tools Needed For Installation Work
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit as described in the user’s guide.
WARNING
CAUTION
Be sure to use the earth line. Do not place earth line near gas or water pipes, lightning conductor and the earth line of telephone. Improper earthing may cause electric shocks.
A circuit breaker should be installed depending on the mounting size of the unit. Without a circuit breaker, the danger of electric shock exists.
Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire if flammable gas leaks around it.
Please ensure smooth flow of water when installing the drain hose.
Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric shock and fire.
Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose danger.
Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work. Use wire which is specified for the air conditioner. A short circuit and fire may occur due to the use of low quality wire or improper work.
Be sure to use the specified wire for connecting the indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are inserted into the terminals. Improper insertion and loose contact may cause over-heating and fire.
Please use the specified components for installation work. Otherwise, the units may collapse or water leakage, electric shock and fire may occur.
Do not mix any coolant other than R-22 into the cooling circulation path when mounting or shifting the unit. If it is mixed with air, the high pressure in the circulation path will rise and this may result in broken copper pipes or faults.
THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation).
WARNING
The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
WARNING
The outdoor unit must be mounted at a location which can sup­port heavy weight. Otherwise, noise and vibration will increase.
CAUTION
No nearby heat source and no obstruction near the air outlet is allowed.
The clearance distances from top, right and left are specified in figure below.
The location must be convenient for water drainage and pipe connection with the Outdoor unit.
To avoid interference from noise please place the unit and its remote controller at least 1m from the radio, television and inverter type fluorescent lamp.
To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency machines and high-power wireless systems.
The installation height of indoor unit must be 2.3m or more in a non public area.
CAUTION
Do not expose the unit under direct sunshine or rain. Besides, ventilation must be good and clear of obstruction.
The air blown out of the unit should not point directly to animals or plants.
The clearances of the unit from top, left, right and front are specified in figure below. At least three of the above sides must be open air.
Be sure that the hot air blown out of the unit and noise do not disturb the neighbourhood.
Do not install at a location where there is flammable gas, steam, oil and smoke.
The location must be convenient for water drainage.
Place the outdoor unit and its connection wire at least 1m away from the antenna or signal line of television, radio or telephone. This is to avoid noise interference.
INDOOR UNIT
Names of Indoor Components
The Length of Indoor Unit
Power Cord
Do not alter the power cord.
Direction of Piping
Figure showing the Installation of Indoor and Outdoor Unit.
The difference in height
between the indoor and outdoor unit should be kept max. 10m.
The connecting pipe, no
matter big or small, should all be insulated with insulation pipe and then wrapped with plastic tape. (The insulator will deteriorate if it is not wrapped with tape).
The connection of insulated drain hose.
Please use insulated drain hose for the indoor piping (commercial product).
OUTDOOR UNIT
Be sure to completely seal any gap with putty.
There are 4 directions allowed, namely, horizontally perpendicular to the unit, vertically down from right, horizontally out from right and horizontally out to left. Don't form the piping downward at the left of the unit.
<
IA539: A
>
Screw for holder of Remote Controller
(3.1x16)
AAA Size Battery
Holder for Remote Controller
Mounting Plate
QtyNo. Component’s Name
1
6
1
2
2
Remote Controller
Purifying Filter
!
!
!
!
about 1.6m
about
0.9m
20
Cut away shaded portion, and finish the edge of the opening so that there is no burr.
Connection
Horizontally perpendicular to the unit
!
!
!
!
Dimension of Mounting Stand
of the outdoor unit
(unit : mm)
500
100
35
35
12
225
8
mounting stand
Indoor Unit
Outdoor Unit
RAS-S10CY RAS-5115CY RAS-S13CY
In case the pipe length is more than 8m, add refrigerant R22 at 15 gram per every meter exceeds. However, pipe length shall not exceed 15m.
CAUTION
!
1
2
3
4
5
6
7
1
1
Installation of Hanger, Wall Penetration and Installation of Protection Pipe
1
CAUTION
!
The draining of the water container inside the indoor unit can be done from the left. Therefore the hanger must be fixed horizontally or slightly tilted towards the side of drain hose. Otherwise, condensed water may overflow the water container.
Direct Mounting On The Wall
Please use hidden beams in the wall to hold the hanger.
Wall Penetration and Installation of Protection Pipe
Drill a ø 65mm hole on wall which is slightly tilted towards the outdoor side. Drill the wall at a small angle.
Cut the protection pipe according to the wall thickness.
Empty gap in the sleeve of protection pipe should be completely sealed with putty to avoid dripping of rain water into the room.
Procedures of Installation and Precautions
Procedures to fix the hanger.
1.Drill holes on wall. 2. Push plug into the holes. 3. Fix the hanger on wall (As shown below) (As shown below) with 4.1 x 32 screw
(As shown in figure below)
Procedures to fix the holder of remote control.
1.Drill holes on wall. 2. Push plug into the holes. (As shown below) (As shown below)
Installation of the Indoor Unit
2
VERTICALLY DOWNWARD PIPING
Preparation
Connect connecting cord.
Pull out the pipe, connecting cord and drain hose.
Installation
The upper part of the Indoor unit is hanged on the hanger.
The projection at the lower part of the Indoor unit is hooked onto the hanger.
Please pull the lower part of the Indoor unit outwards to check if the unit is hooked onto the hanger. Improper installation may cause vibration and noise.
!
CAUTION
HORIZONTAL PIPING
Preparation
Change of Drain Hose and Installation Procedures.
Exchange the location of drain hose and drain cap during horizontal piping as shown in figure below. Be sure to plug in the drain hose until the insulating material folds upon itself.
Please use pliers to pull out the drain cap. (This is an easier way to remove the drain cap).
INSTALLATION OF REFRIGERATING PIPES AFTER CONNECTION
The refrigerating pipes should be adjusted to fit into the hole on the wall and then ready for further connection.
The terminals of 2 connected pipes must be covered with insulator used for terminal connection. Then the pipes are wrapped with insulation pipe.
Connect the connecting cord after removing electrical cover. (Refer to CONNECTION OF POWER CORD”)
After adjustment, fit the connecting cord and pipes into the space available under the indoor unit. Use holder to hold them tight.
!
CAUTION
The rubber strap used for fixing the insulator should not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation.
Holder can be attached at the either of 2 places. Please select the easier position.
THE CONNECTION OF REFRIGERATING PIPE DURING THE INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
!
CAUTION
Please fix in the plastic core after flaring to avoid plastic chips entering the pipes.
CAUTION
!
You are free to choose the side (left or right) for the installation of drain hose. Please ensure the smooth flow of condensed water of the Indoor unit during installation. (Carelessness may result in water leakage.)
!
CAUTION
Be sure that the drain hose is not loosely connected or bend.
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse. Unless it seals completely, any air with high humidity flows from outdoor and any dew may drop.
!
WARNING
The refrigerating pipes and connecting cord transform and are attached.
The end of the refrigerating pipes are at locations marked with
symbol.
Installation of Drain Hose
3
Installation
Hang the Indoor unit onto the hanger. Use the temporary stand at the back of the Indoor unit to push its lower part 15cm forwards.
Place the drain hose through the hole on the wall.
Wrap the refrigerating pipes with insulation pipe after connecting refrigerating pipe.
Connect the connecting cord after removing electrical cover. (Refer to Connection of Power Cord”)
After adjustment, the connecting cord and refrigerating pipes are placed into the space available under the Indoor unit.
The projection of Indoor unit must hook to the hanger.
INDOOR UNIT
HOW TO REMOVE INDOOR UNIT
Push up the (PUSH) sections at the bottom of the indoor unit and pull the bottom plate towards you. Then the claws are released from the stationary plate. (The (PUSH) sections are indicated by 2 arrows in the right figure)
Sleeve of protection pipe
WALL
Protection pipe
Seal with putty
Seal with putty
2 ~ 5mm
OutdoorIndoor
Connecting cords, pipe and drain hose must be laid together with Vinyl tape.
Lift the body of the unit upwards and then force it downwards.
Hanger
Refrigerating Pipe
Protection Pipe
Drain Hose
Connecting Cord
Hanger
1
Projection
2
[
Push] mark positions
!
CAUTION
Condensed water may leak out if not inserted properly.
HORIZONTAL & DOWNWARD PIPING – MAKING OPENINGS
During horizontal or downward piping, use a knife to cut openings as shown in figure. Then smoothen the edges of openings with a file.
Turn the piping while holding down the lower portion of pipe-support by hand.
Drain hose
Drain cap
Drain cap
Please insert until here
Drain hose
Please insert until here
Pipe support
Pull up the pipe after bending downward
Openings
Pipe
Connecting cord
Drain hose
Insulation pipe (must be wrapped with vinyl tape at every 120mm).
8
Holder
Pipe
Rubber strap tied with great force
below 5mm
Please bend at a small radius to form an arc
0.85m
about 15cm
Hook
Projection
Protection pipe
Connecting cord
Holder
Connected section
Drain hose
Heat insulation pipe
Connecting cord
Refrigerating pipe
Pull this to the front during the connection of refrigerating pipes to ease task.
Bending upwards
Condensed water pond
Ditch
Condensed water pond
125mm
45mm
450mm
60mm
80mm
780mm
125mm
280mm
45mm 115mm
450mm
Level
Hanger
Hole for pipe
Weight
Mark
Line
Please use more than 4 screws.
Screw for Hanger
RAC-S10CY RAC-5115CY RAC-S13CY
8
1
Hole cover sticker
INS RAS/RAC-S10CY (E1) 1/6/09, 9:241
Black
OUTDOOR UNIT
Please mount the outdoor unit on stable ground to prevent vibration and increase of noise level.
Decide the location for piping after sorting out the different types of pipe available.
Please face this side (suction side) of the unit to the wall
Please remove the cover for wire connection.
Procedure to remove the cover of
wiring terminals
Remove the screw (1 piece).
Hold the projected part at the lower left of the cover and push the cover upwards to remove it.
To close the cover, insert the upper part of the cover into the body of outdoor unit, then be sure that the hook below the cover is plugged in before screwing.
Hook
Removal Of Air From The Pipe And Gas Leakage Inspection Preparation of Pipe
1
Use a pipe cutter to cut the copper pipe.
Jagged edge will cause leakage.
Point the side to be trimmed downwards during trimming to prevent copper chips from entering the pipe.
Before flaring, please put on the hexagon screw cap.
Spanner
Torque wrench
Hexagon screw nut
Pipe Connection
2
Please be careful when bending the copper pipe.
Applied frozen grease to the connection points and then screw in manually. After that, use a torque wrench to tighten the connection.
INSTALLATION OF COOLANT PIPES AND AIR REMOVAL
Procedures of using Vacuum Pump for Air Removal
3
AIR REMOVAL
CAUTION
!
Lo
Hi
Meter showing pressure
Manifold valve
Vacuum pump
Charge hose
When pumping starts, slightly loosen the flare nut to check of air sucked in. Then tighten the flare nut.
When the meter reaches –101KPa (–76cmHg) during pumping, fully tighten the shuttle.
As shown in figure on the right, remove the cap of valve head and valve core and then connect them to the vacuum pump and sub-division valve.
Fully tighten the “Hi” shuttle of the sub­division valve and completely unscrew the “Lo” shuttle. Run the vacuum pump for about 10–15 minutes, then completely tighten the “Lo” shuttle and switch off the vacuum pump.
2
Completely unscrew the spindle of the service valve (at 2 places) in anti­clockwise direction to allow the flow of coolant (using Allen key).
3
Remove the connection pipe and tighten the cap of valve head. The task is then completed.
4
Gas Leakage Inspection
Please use gas leakage detector to check if leakage occurs at the con­nection of hexagon screw nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop leakage.
The body of service valve
Cap of valve core
Allen key
Cap of valve head
Cap of valve head
A
Mould
Mould
Copper pipe
Copper pipe
Trimming tool
1
<
IA539: A
>
FINAL STAGE OF INSTALLATION
Insulation And Maintenance Of Pipe Connection
1
The connected terminals should be completely sealed with heat insulator and then tied up with rubber strap.
Please tie the pipe and power line together with vinyl tape as shown in the figure showing the installation of Indoor and Outdoor units. Then fix their position with holders.
To enchance the heat insulation and to prevent water condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe.
Completely seal any gap with putty.
Installation Of Remote Controller
2
Power Source And Operation Test
3
The remote controller can be placed in its holder which is fixed on wall or beam.
To operate the remote controller at its holder, please ensure that the unit can receive signal transmitted from the controller at the place where the holder is to be fixed. The unit will beep when signal is received from the remote controller. The signal transmission is weaken by the fluorescent light. Therefore, during the installation of the remote control holder, please switch on the light, even during day time, to determine the mounting location of the holder.
Power Source
CAUTION
!
Please use a new socket. Accident may occur due to the use of old socket because of poor contact.
Please plug in and then remove the plug for 2 – 3 times. This is to ensure that the plug is completely plugged into the socket.
Keep additional length for the power cord and do not render the plug under external force as this may cause poor contact.
Do not fix the power cord with U-shape nail.
Operation Test
Please ensure that the air conditioner is in normal operating condition during the operation test.
Explain to your customer the proper operation procedures as described in the users manual.
WARNING
If you cannot attach the side cover due to the connecting cord, press the connecting cord in direction to the front panel to fix it.
Be sure that the hooks of the side cover is fixed in certainly. Otherwise water leakage may occur and this causes short circuit or faults.
The naked part of the wire core should be 10 mm and fix it to the terminal tightly. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal.
Be sure to use only power cables approved from the authorities in your country. For example in Germany: Cable type: NYM 3x2.0mm
2
.
Please refer to the installation manual for wire connection to the terminals of the units. The cabling must meet the standards of electrical installation.
There is an AC voltage drop between the L and N terminals if power is on. Therefore, before servicing, be sure to remove the plug from the AC outlet or switch off the main switch.
THIS APPLIANCE MUST BE EARTHED.
Procedures of Wiring
Wiring of The Outdoor Unit
Please remove the side cover for wire connection.
!
WARNING
!
CONNECTION OF POWER CORD
WARNING
!
Connecting cord
Indoor
Unit
Outdoor
Unit
GRN + YEL
GRN + YEL
Strip wires
L N
BABA
Indoor Unit
Line Cord
AC 220-240V
Outdoor Unit
Connecting Cord
d
Sleeve of protection pipe
Putty
Putty
Insulation material for pipe connection
Pull the cover at 1 and 2 in the directions as shown by arrows to remove the low cover.
Wiring Of The Indoor Unit
For wire connection of the Indoor unit, you need to remove Low Cover and Indicator Cover.
Remote
Controller
Holder for Remote Controller
Screw (2 pieces)
The controller should be insert from top into bottom side of the holder as shown in figure below.
Connection wire is put under here
Side cover
A
B
Connection wire
Screw for earth line
TIME DELAY FUSE USAGE
Outer
Diameter (ø)
6.35 (1/4")
9.52 (3/8")
Imperial
flaring tool
0.8 – 1.5
1.0 – 2.0
Rigid flaring
tool
0 – 0.5
0 – 1.0
A (mm)
After unscrew and remove electrical plate, unscrew the terminal band to put connecting cords. Fix back the band screw and electrical plate.
TEMPORARY SWITCH
1
Indicator Cover
Screw
Low cover
Remove Screw and Indicator Cover
T
E
M
P
O
R
A
R
Y
S
W
I
T
C
H
2
TEMPORARY
SWITCH
6 5
Attach Indicator Cover and tightened screw (do not tightened too hard as the screw hole at front cover might be broken)
Attach back Low Cover
TEMPORARY SWITCH
7
3
4
RAS-S10CY, RAS-5115CY
Outer
Diameter (ø)
6.35 (1/4")
12.7 (1/2")
Imperial
flaring tool
0.8 – 1.5
1.0 – 2.0
Rigid flaring
tool
0 – 0.5
0 – 1.0
A (mm)
RAS-S13CY
Valve head cap
Valve core cap
Torque N.m
(kgf
cm)
13.7 – 18.6 (140 – 190)
34.3 – 44.1 (350 – 450)
19.6 – 24.5 (200 – 250)
12.3 – 15.7 (125 – 160)
Small dia. side
Big dia. side
Outer
dia. of pipe
9.52 (3/8")
6.35 (1/4")
RAS-S10CY, RAS-5115CY
Valve head cap
Valve core cap
Torque N.m
(kgf
cm)
13.7 – 18.6 (140 – 190)
44.1 – 53.9 (450 – 550)
19.6 – 24.5 (200 – 250)
12.3 – 15.7 (125 – 160)
Small dia. side
Big dia. side
Outer
dia. of pipe
12.7 (1/2")
6.35 (1/4")
RAS-S13CY
10A
15A
RAC-S10CY, RAC-5115CY
RAC-S13CY
Please fix back the electrical plate after wiring work is complete. Otherwise if short circuit occur it may cause unit burn.
WARNING
!
CABLE SIZE ød
1-25mm
1-50mm
RAS-S10CY, RAS-5115CY
RAS-S13CY
INS RAS/RAC-S10CY (E2) 1/6/09, 9:251
Black