SAFETY PRECAUTION
●
Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
●
Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
●
The sign indicate the following meanings.
Make sure to connect earth line.
Indicates the instructions that must be followed.
●
Please keep this manual after reading.
PRECAUTIONS DURING INSTALLATION
●
Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct
the unit by yourself.
●
!
WARNING
!
CAUTION
Please ask your sales agent or qualified technician for the installation
of your unit. Water leakage, short circuit or fire may occur if you install
the unit by yourself.
●
Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.
●
A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.
●
Do not install near location where there is flammable gas. The outdoor
unit may catch fire if flammable gas leaks around it.
●
Please ensure smooth flow of water when installing the drain hose.
!
!
The sign in the figure indicates prohibition.
PRECAUTIONS DURING SHIFTING OR MAINTENANCE
●
Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
!
W
occur if you continue to operate the unit under abnormal situation.
A
●
Please contact your agent for maintenance. Improper self maintenance may cause
R
electric shock and fire.
N
I
●
Please contact your agent if you need to remove and reinstall the unit. Electric
N
shock or fire may occur if you remove and reinstall the unit yourself improperly.
G
PRECAUTIONS DURING OPERATION
●
Avoid an extended period of direct air flow for your health.
!
W
A
R
N
●
Do not use any conductor as fuse wire, this could cause fatal accident.
I
N
G
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM2
●
Do not put objects like thin rods into the panel of blower and suction side
because the high-speed fan inside may cause danger.
●
During thunder storm, disconnect and turn off the circuit breaker.
– 2 –
PRECAUTIONS DURING OPERATION
●
The product shall be operated under the manufacturer specification and
not for any other intended use.
●
Do not attempt to operate the unit with wet hands, this could cause fatal
accident.
●
When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.
●
Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.
●
Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.
●
Do not splash or direct water to the body of the unit when cleaning it as this
may cause short circuit.
●
Do not use any aerosol or hair sprays near the indoor unit. This chemical
can adhere on heat exchanger fin and blocked the evaporation water flow
!
to drain pan. The water will drop on tangential fan and cause water splashing
out from indoor unit.
C
A
U
T
I
O
N
●
Turn off the circuit breaker if the unit is not to be operated for a long period.
●
Please switch off the unit and turn off the circuit breaker during cleaning, the
high-speed fan inside the unit may cause danger.
ENGLISH
●
Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit
and causes short-circuit.
●
When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air deflector facing down or moving automatically for a long period of time,
water will condense on the air deflector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
●
If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.
●
This appliance is not intended for use by young children or infirm persons unless they have been
adequately supervised by a responsible person to ensure that they can use the appliance safely.
●
Young children should be supervised to ensure that they do not play with the appliance.
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM3
●
Do not climb on the outdoor unit or put objects on it.
●
Do not place plants directly under the air flow as it is bad for the plants.
– 3 –
INDOOR UNIT
RAS-5111CS
OUTDOOR UNIT
NAMES AND FUNCTIONS OF EACH PART
AIR FILTER
To prevent dust from coming into the indoor unit.
(Refer page 21)
FRONT PANEL (AIR INLET).
INDOOR UNIT INDICATORS
Light indicator showing the operating condition.
(Refer page 5)
HORIZONTAL DEFLECTOR
DEFLECTOR (AIR OUTLET)
(Refer page 13)
REMOTE CONTROL
Send out operation signal to the indoor unit. So as to
operate the whole unit.
(Refer page 6)
●
VERTICAL
RAC-5111C
MODEL NAME AND DIMENSIONS
RAS-5111CS
RAC-5111C
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM4
DRAIN PIPE
Condensed water drain to outside.
CONNECTING CORD
AIR INLET (BACK, LEFT SIDE)
AIR OUTLET
WIDTH (mm)MODEL
860
700
– 4 –
HEIGHT (mm)
285
570
DEPTH (mm)
188
210
INDOOR UNIT INDICATORS
HITACHI
OPERATION INDICATOR
OPERATION LAMP
This lamp lights during operation.
ENGLISH
TIMER LAMP
This lamp lights when the timer is working.
FILTER LAMP
When the device is operated for a total of about 200
hours, the FILTER lamp lights to indicate that it is time
to clean the filter. The lamp goes out when the POWER
SWITCH set to OFF and ON again.
● This figure shows the opening condition of
front panel. Refer to page 20 in relation to
how to open or close the front panel.
TEMPORARY / AUTO RESTART
TEMPORARY / AUTO RESTART
AUTO RESTART SWITCH
● In the event of power failure, the air conditioner will restart automatically in the previously selected mode once
the power is restored.
● In the event of power failure during TIMER operation, the timer will be reset and the unit will begin or stop
operating under a new timer setting.
TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.
● By setting the temporary switch, the operation is done in previously set operation mode.
● When the operation is done using the temporary switch after the power source is turned off and turn on again,
the operation is done in automatic mode.
– 5 –
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM5
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting
is controlled electronically, the range of control may be shorter.
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can
be controlled from the remote controller.
Signal Transmission
CH
˚
CH
˚
RESET
AUTO
HEAT
DEHUMIDIFY
COOL
FAN
FAN SPEEDHI
MEDLOW
SLEEPING
STOP (CANCEL)
START (RESERVE)
START/STOP
TIME
TIMER SET
TIMER SELECTOR ON TIMER OFF TIMER
AUTO SWING
●
Transmission sign
The transmission sign blinks when a signal is sent.
●
Display
This indicates the room temperature selected, current time, timer status,
function and intensity of circulation selected.
●
START/STOP button
Press this button to start operation. Press it again to stop operation.
●
SLEEP button
Use this button to set the sleep timer.
●
SUPER SILENT button
Use this button to set silent condition.
●
SUPER COOLING button
Use this button to set super cooling operation.
●
TEMPERATURE button
Use this button to raise or lower the temperature setting. (Keep pressed,
and the value will change more quickly.)
●
OFF-TIMER button Select the turn OFF time.
●
ON-TIMER button Select the turn ON time.
●
TIME button
Use this button to set and check the time and date.
●
RESET button
●
FUNCTION selector
Use this button to select the operating mode. Every time you press it,
the mode will change from
(CIRCULATION) and to (FAN) cyclically.
to
●
FAN SPEED selector
(AUTO) to (COOL) to (DEHUMIDIFY)
This determines the fan speed. Every time you press this button, the intensity
of circulation will change from (AUTO) to (HI) to (MED) to (LOW)
(during the (FAN) mode, from HI to MED to LOW).
●
AUTO SWING button
Controls the angle of the horizontal air deflector.
●
TIMER control
Use this button to set the timer.
●
RESERVE button Time setting reservation.
●
CANCEL button Cancel time reservation.
Precautions for Use
●
Do not put the remote controller in the following places.
●
In direct sunlight.
●
In the vicinity of a heater.
●
Handle the remote controller carefully. Do not drop it on the floor,
and protect it from water.
●
Once the outdoor unit stops, it will not restart for about 3 minutes
(unless you turn the power switch off and on or unplug the power
cord and plug it in again).
This is to protect the device and does not indicate a failure.
●
If you press the FUNCTION selector button during operation, the
device may stop for about 3 minutes for protection.
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM6
– 6 –
AUTOMATIC OPERATION
The device will automatically determine the mode of operation COOL, or Dehumidify, depending on the
initial room temperature. The selected mode of operation will not change when the room temperature
varies.
RESET
Press the FUNCTION selector so that the display indicates
the (AUTO) mode of operation.
1
● When AUTO has been selected, the device will
automatically determine the mode of operation COOL or
Dehumidify, depending on the initial room temperature
and outdoor temperature.
START
STOP
Press the
Operation starts with a beep.
Press the button again to stop operation.
■ As the settings are stored in memory in the remote controller, you
only have to press the
You can raise or lower the temperature setting as necessary by
maximum of 3°C.
°C
● The preset temperature and the actual room temperature may
vary somewhat depending on conditions.
● The display does not indicate the preset temperature in the
AUTO mode. If you change the setting, the indoor unit will
produce a beep.
(START/STOP) button.
(START/STOP) button next time.
Press the temperature button and the
temperature setting will change by 1°C each
time.
ENGLISH
■ CONDITION OF AUTOMATIC OPERATION
● The selected mode of operation will not change during the operation even though the room temperature
change.
INITIAL ROOM
TEMPERATURE (APPROX.)
Over 27°CCOOL
16~27°C
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM7
FUNCTION
-
-
DEHUMIDIFY
– 7 –
TEMPERATURE
SETTING
27°C
Slightly lower than the
room temperature
FAN SPEED
HIGH at start, LOW after
the preset temperature is
reached.
LOW
C
COOLING OPERATION
Use the device for cooling when the outdoor temperature is 21-43°C.
If humidity is very high (over 80°C) indoors, some dew may form on the air outlet grille of the indoor unit.
Press the FUNCTION selector so that the display indicates
C
˚
1
(COOL).
RESET
Set the desired FAN SPEED with the
(the display indicates the setting).
(AUTO): The FAN SPEED is HI at first and varies to
2
(HI): Economical as the room will become cool
(MED) : Fan speed slow.
(LOW) : Fan speed slower.
Press the
START
STOP
C
˚
with a beep. Press the button again to stop operation. The
cooling function does not start if the temperature setting is
higher than the current room temperature (even though the
(OPERATION) lamp lights). The cooling function will start as
soon as you set the temperature below the current room
temperature.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
3
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.
■ As the settings are stored in memory in the remote controller, you
only have to press the
MED or LOW automatically when the preset
temperature has been reached.
quickly.
(START/STOP) button. Cooling operation starts
The range of 25-28°C is recommended as the
room temperature for cooling.
˚
If the temperature setting is 27°C, the room
temperature will be controlled at around 27°C.
(START/STOP) button next time.
(FAN SPEED) button
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM8
– 8 –
DEHUMIDIFYING OPERATION
C
Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.
Press the FUNCTION selector so that the display indicates
(DEHUMIDIFY).
The FAN SPEED is set at LOW automatically.
1
The FAN SPEED button does not work.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
2
The range of 20-26˚C is recommended as the
˚
room temperature for dehumidifying.
RESET
C
˚
ENGLISH
START
STOP
■ As the settings are stored in memory in the remote controller, you only
C
˚
Press the (START/STOP) button. Dehumidifying operation
starts with a beep. Press the button again to stop operation.
have to press the
(START/STOP) button next time.
■ Dehumidifying Function
When the room temperature is higher than the temperature setting: The device will dehumidify the room,
reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at the
temperature setting slightly lower than the current room temperature, regardless of the temperature
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature
becomes lower than the setting temperature.
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM9
– 9 –
FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.
START
STOP
1
RESET
FAN SPEED (AUTO)
CIRCULATION OPERATION
C
˚
RESET
2
.....
When the AUTO fan speed mode is set in Automatic or cooling operation
1
3
START
STOP
Press the (START/STOP) button. Fan operation starts with
a beep. Press the button again to stop operation.
Press the FUNCTION selector so that the display indicates
(FAN).
Press the
Press the FUNCTION selector so that the display indicates
Press the FAN SPEED button and select the desired FAN
2
SPEED (the display indicates your choice).
Press the temperature control button to set to the desired
temperature.
(FAN SPEED) button.
(CIRCULATE).
Press the (START/STOP) button. Circulating operation
starts with a beep. Press the button again to stop operation.
C
˚
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM10
■ As the settings are stored in memory in the remote controller,
you only have to press the
– 10 –
(START/STOP) button next time.
SUPER COOLING
C
˚
Press the button.
1
● Operation start with a signal received sound “beep”.
● Unit will be forced operate in (COOL) with SUPER HI fan
speed for 20 minutes. Indicator appear during this period
while temperature and fan speed setting display remain
unchanged. (Operation lamp at indoor unit is blinking).
● After 20 minutes, operation lamp stop blinking and indicator
will disappear while unit will be in
(COOL) mode. Temperature
and fan speed will change to previous setting.
● Air blow sound will be slightly high due to forced operation.
ENGLISH
RESET
C
˚
CANCELLATION of SUPER COOLING Operation
Cancel Condition
Press or OFF timer time is up
key press
Operation mode after cancel
Stop operation
DEHUMIDIFYING operation
Press or
Press or
Press or
Press or
Normal COOLING operation
Press or
20 minutes time is up
NOTE
(1) OFF TIME setting : OFF timer will be a priority over the
(2) ON TIME setting : SUPER COOLING operation will be a
SUPER COOLING operation time.
priority over the ON timer operation time.
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:15 PM11
– 11 –
SUPER SILENT
C
˚
Press the button.
1
● Operation start with a signal received sound “beep”.
● Unit will be forced operate in any operation mode as before
with SUPER SILENT fan speed. The indication of operation
mode, temperature setting, fan speed and timer value on
remote controller will remain no change.
CANCELLATION of SUPER SILENT Operation
RESET
Cancel Condition
Press button.
OFF timer time is up
C
˚
Sleeping timer time is up
Press SUPER COOL button
Press button
Press SUPER SILENT button.
Operation mode after cancel
Stop operation
SUPER COOL operation
Next fan speed operation
Existing operation mode
NOTE:
Under SUPER SILENT operation and quiet environment, phenomena like flowing noise of refrigerant in
the refrigerating cycle may occur, but this is normal for the operation.
EN1-RAS-5111CS/RAC-5111C16/11/05, 4:16 PM12
– 12 –
ADJUSTING THE AIR DEFLECTOR
Adjustment of the conditioned air in the upward and downward
1
directions.
According to “Dehumidifying” or “Cooling” operation, the
horizontal air deflector is automatically set to the proper angle
suitable for each operation. The deflector can be swung up and
down and also set to the desired angle using the “ (AUTO
SWING)” button. (If the angle of the deflector is changed, it will
not return to the auto-set position after operations start unless
the operation mode is switched.)
● If the “ (AUTO SWING)” button is pressed once, the
horizontal air deflector swings up and down. If the button
is pressed again, the deflector stops in its current position.
Several seconds (about 6 seconds) may be required
before the deflector starts to move.
● In “Cooling” operation, do not keep the horizontal air
deflector swinging for a long time. Some dew may form
on the horizontal air deflector and dew may drop.
Adjustment of the conditioned air to the left and right.
2
Hold the vertical air deflector as shown in the figure and
adjust the conditioned air to the left and right.
RESET
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER
ENGLISH
Remove the cover as shown in the figure and take out the old
1
batteries.
=
Install the new batteries.
2
The direction of the batteries should match the marks in the case.
!
CAUTION
1. Do not use new and old batteries, or different kinds of batteries
together.
2. Take out the batteries when you do not use the remote controller
for 2 or 3 months.
EN2-RAS-5111CS/RAC-5111C16/11/05, 4:16 PM13
Push and pull to the
direction of arrow
– 13 –
HOW TO SET THE TIMER
RESET
ON/OFF-Timer
StartStop
● The device will turn on (off) and off
(on) at the designated times.
● The switching occurs first at the
preset time that comes earlier.
● The arrow mark appearing on the
display indicates the sequence of
switching operations.
TIME, DAY,
MONTH
(current time,
After you change the
batteries;
day, month)
OFF TIMER
Time, Day, Month
ON TIMER
OFF-Timer
RESERVE
CANCEL
You can set the device to turn off
at the present time.
ON-Timer
● The device will turn on at
the designated times.
1 Press the (ON-OFF)
button so that the (OFF)
mark blinks.
PM
MD
Start
STOP
Stop
2 Set the turn-off time
with the TIMER control
button.
Press the (RESERVE)
button.
1 Set the current month and
day with the TIMER control
button.
MD
1 Press the (OFF-TIMER)
button. The (OFF) mark blinks
on the display.
1 Press the (ON-TIMER)
Start
button the (ON) mark blinks
on the display.
3 Press the (ON-
TIMER) button so that the
(OFF) mark lights and
the (ON) mark blinks.
PM
AM
AM
PM
AM
How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.
NOTE
You can set only one of the OFF-timer,
ON-timer and ON/OFF-timer.
– 14 –
EN2-RAS-5111CS/RAC-5111C16/11/05, 4:16 PM14
2 Press the
(TIME) button.
3 Set the current time with the
TIMER control button.
AM
PMPM
Example: The current time is 1:30 p.m.
4 Press the (TIME) button again.
The time indication starts lighting
instead of flashing.
● The time indication will disappear
PM
automatically in 10 seconds.
● To check the current time setting,
press the (TIME) button twice.
The setting of the current time is
now complete.
ENGLISH
2 Set the turn-off time with the
TIMER control button.
PM
2 Set the turn-on time with the
TIMER control button.
AM
4 Set the turn-on time with the
TIMER control button.
PM
AM
3 Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The (OFF) mark starts lighting instead of flashing and the sign (RESERVED)
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
PM
The setting of turn-off time is now complete.
3 Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
AM
5 Point the signal window of the remote controller toward the indoor unit, and
press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
PM
AM
Example: The device will turn off at 11:00p.m.
Example:
The device will automatically turn on earlier so that the preset
temperature can be reached at 7:00 a.m.
The setting of the turn-on time is now complete.
Example:
The device will turn off at 10:30 p.m. and then automatically
turn on earlier so that the preset temperature can be reached
at 7:00 a.m.
The settings of the turn-on/off times are now complete.
● The timer may be used in three ways: off-timer, on-timer, and ON/OFF (OFF/ON)-timer. Set
the current time at first because it serves as a reference.
● As the time settings are stored in memory in the remote controller, you only have to press
the (RESERVE) button in order to use the same settings next time.
– 15 –
EN2-RAS-5111CS/RAC-5111C16/11/05, 4:16 PM15
HOW TO SET THE SLEEP TIMER
Set the current time at first if it is not set before (see the pages for setting
the current time). Press the (SLEEP) button, and the display changes as
shown below.
Mode
4444
H
SLEEP
Sleep timer
Sleep Timer: The device will continue working for the designated
number of hours and then turn off.
Point the signal window of the remote controller toward the indoor
unit, and press the SLEEP button.
The timer information will be displayed on the remote controller.
The TIMER lamp lights with a beep from the indoor unit. When the
sleep timer has been set, the display indicates the turn-off time.
H
Sleep
timer
Start
1 hour 2 hours 3 hours 7 hours
The device will be turned off by the sleep
timer and turned on by on-timer.
Indication
Sleep timer off
Example: If you set 3 hours sleep
time at 11:38 p.m., the turn-off
time is 2:38 a.m.
1
1 Set the ON-timer.
2 Press the (SLEEP) button and set the sleep timer.
AM
In this case, the device will turn off
H
AM
in 2 hours (at 1:38 a.m.) and starts
at 6:00 a.m. next morning.
How to Cancel Reservation
Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.
– 16 –
EN2-RAS-5111CS/RAC-5111C16/11/05, 4:16 PM16
Loading...
+ 36 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.