Hitachi RAI-25RPA, RAI-35RPA, RAI-50RPA Installation Manual

HITACHI CEILING CASSETTE-UNIT AIR
CONDITIONER INSTALLATION MANUAL
Indoor Unit
+ –
ø 65mm Power Drill Hexagonal Wrench Key ( 4mm)
Wrench (14, 17, 19, 22, 26, 27mm) Gas Leakage Detector
Pipe Cutter Vinyl Tape ● Pliers ● Flare Tool
Carefully read through the procedures of proper installation
before starting installation work.
The sales agent should inform customers regarding the correct
operation of installation.
Tools Needed For Installation Work
SAFETY PRECAUTION
Read the safety precautions carefully before operating the unit.
The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING ........ Incorrect methods of installation may cause death or serious injury.
CAUTION ......... Improper installation may result in serious consequence.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper way of operating the unit as
described in the user’s guide.
!
!
WARNING
!
CAUTION
!
A circuit breaker or fuse (16A time delay) must be installed. Without a circuit breaker or fuse the danger of electric shock exists.
A main switch with a contact gap of more than 3.5mm has to be installed in the power supply line to the outdoor unit.
Piping shall be suitable supported with a maximum spacing of 1m between the supports.
Do not install the unit near a location where there is  ammable gas. The outdoor unit may
catch  re if  ammable gas leaks around it.
For installation of front panel RAI-ECPP, please follow exactly the instruction in the manual.
Please ensure smooth  ow of water when installing the drain hose.
Please request your sales agent or quali ed technician to install your unit. Water leakage, short circuit or  re may occur if you do the installation work yourself.
Please observe the instructions stated in the installation manual during the process of installation. Improper installation may cause water leakage, electric
shock and  re.
Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may collapse and impose
danger.
Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing with the electrical work.
Use power cables approved by the authorities of your country.
Be sure to use speci ed wire for the connection indoor and outdoor units. Please ensure that the connections are tight after the conductors of the wire are
inserted into the terminals. Improper insertion and loose contact may cause over-heating and  re.
Please use the speci ed components for installation work. Otherwise, the units may collapse or water leakage, electric shock and  re may occur.
Be sure to use the speci ed piping set for R-410A. Otherwise, this may result in broken copper pipes or faults.
When installing or removing an air conditioner, only speci ed refrigerant (R410A) shall be allowed, do not allow air or moisture to remain in the refrigeration
cycle. Otherwise, pressure in the refrigeration cycle may become abnormally high so that a rupture may be caused.
Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with  re, a poisonous gas may occur.
After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the room, coming into
contact with  re in the fan-driven heater, space heater, etc., a poisonous gas may occur.
Unauthorized modi cations to the air conditioner may be dangerous. If a breakdown occurs please call a quali ed air conditioner technician or electrician.
Improper repairs may result in water leakage, electric shock and  re, etc.
THE CHOICE OF MOUNTING SITE
(Please note the following matters and obtain permission from customer before installation).
WARNING
!
The unit should be mounted at stable, non-vibratory location which can provide full support to the unit.
CAUTION
!
No nearby heat source and no obstruction near the air outlet is allowed.
The clearance distances from top, right and left are speci ed in  gure below.
The location must be convenient for water drainage and pipe connection with the outdoor unit.
To avoid interference from noise please place the unit and its remote controller at least 1m from the radio, television and inverter type  uorescent lamp.
To avoid any error in signal transmission from the remote controller, please put the controller far away from high-frequency machines and high-power wireless
systems.
The installation height of indoor unit must be 2.3m or more.
INDOOR UNIT
Names of Indoor Components
Insulation pipe for  are section
QtyNo. Item
Figure showing the Installation of Indoor Unit.
2
Opening on ceiling and suspension bolt
1
(Unit : mm)
Need a connecting work for refrigerant pipe, drain pipe and F cable in the ceiling after
suspending the indoor unit. Arrange drain pipe, refrigerant pipe and F cable in their installation position.
For  nishing of opening on ceiling, arrange with builder in detail.
If ceiling is already completed, connecting cables between indoor and outdoor, piping and
drain piping must be done before  tting indoor unit.
Wall Penetration and Installation of Protection Pipe
Drill a ø 65mm hole on wall which is slightly tilted towards
the outdoor side. Drill the wall at a small angle.
Cut the protection pipe according to the wall thickness.
Empty gap in the sleeve of protection pipe should be
completely sealed with putty to avoid dripping of rain water into the room.
In case drain piping cannot be done smoothly due to obstacles, it can also be arranged
outside of the main unit as shown in the drawing below.
!
CAUTION
The rubber strap used for fixing the insulator should not be tied with great force. Otherwise, this will damage heat insulation and causes water condensation.
Connecting the pipe to the indoor unit
Remove the  are nut and seal cap. By loosening the  are nut at the pipe end, the refrigerant is discharged in a small amount.
The arrangement has been made for shipment, and the discharge of refrigerant is never a trouble to the equipment.
When the  are nut is removed, never fail to remove the seal cap. If not removed, the refrigerant will not be circulated, which result the compressor drive motor will possibly be burnt.
Apply refrigerator oil to the union and the  ared portion of the pipe. Wrap  are insulation, bind top and bottom  are insulation by binder.
Be sure that the wire is not in contact with any metal in the wall. Please use the protection pipe as wire passing through the hollow part of the wall so as to prevent the possibility of damaged by mouse.
!
CAUTION
Connecting of drain pipe
Securely glue connection part of
drain hose and PVC pipe, using PVC adhesive.
If gluing of drain hose and PVC pipe
is too weak, water leakage may occur.
Be sure to wrap generally-available
insulator (10mm or more of foamed polyethylene) around drain hose, inside the house, for insulation heat.
Checking drain and water leakage.
Perform after connecting power.
If checking of drainage is omitted,
water drop may occur.
Add water to water pan of indoor unit
as shown below.
Perform test running of drain pump
to check drainage operation.
Test run method
1 Turn power on. 2 Remove cover of electric box and
set the drain pump test run switch to TEST.
3 After checking the drainage, return
the switch to NORMAL.
Connecting the pipe
4
INDOOR UNIT
FOR SERVICE PERSONNEL ONLY
Pattern paper for positioning plate
Screw for holder of Remote Controller
AAA Size Battery
Binder
Insulation pipe for drain pipe
Insulation pipe
Remote Controller
Pattern paper for installation plate
Installation plate  xing screw
(M5 X 16)
4
1
2
2
1
1
1
1
1
4
Blower cover
2
Preparation for installing indoor unit
2
Installation of suspension bolts
Be sure to reinforce furring of ceiling (frame : ceiling joints and supporter) to maintain level
of ceiling and prevent vibration of ceiling plate.
Suspension bolts should be purchased in the  eld.
Refer to diagrams shown below for length of suspension bolts.
In case of wooden frame In case of steel frame (Unit : mm)
Be sure to use protection pipe (commercial product). If connecting cables are touching metal lath inside the wall or inside the wall is hollow where mouse can bite cables, it can cause electrical shock or  re. If sealing is not complete, high humid air from inside the wall or outside of the room can come in and cause water dripping.
!
WARNING
Drain pipe installation
Use PVC pipe VP20 (O.D. 26mm) for drain pipe.
Be sure to roll an insulation (thickness 10mm or more) for the drain pipe at indoor side.
Always draw the drain pipe downward so that water  ows smoothly. Fix it (ex. by hanger)
to prevent a peak and trap.
Installation of indoor unit
3
!
CAUTION
Since 2-way outlet as shown below causes performance problems, do not set it.
Blower cover installation
Install the blower cover only to the air outlet direction which is not in use. Install the blower cover at the diffuser position shown. Fix the blower cover certainly.
Corner seal installation
Install the corner seal at position shown. Fix the corner seal certainly. Shall be installed disregard to 2 directions, 3 directions or 4 directions.
!
CAUTION
When connecting pipes, if  are nut is over-tightened at the small diameter side, the screw thread of the service valve may be broken making pipe connection impossible. Be sure to tighten the nut with speci ed torque.
If drain pump test run is right
set to TEST, drain pump may malfunction.
!
CAUTION
The indoor piping should be insulated with the enclosed insulation pipe. (If the insulator is insuf cient, please use commersial products).
The difference in height
between the indoor and outdoor unit should be kept below 10m.
The connecting pipe, no
matter big or small, should all be insulated with insulation pipe and then wrapped with vinyl tape. (The insulator will deteriorate if it is not wrapped with tape).
Drain Pipe Must be installed separately. Insulate indoor part of pipe to prevent condensation.
Be sure to completely seal any gap with putty.
Drawing of bottom view of ceiling
Be sure to install the indoor unit level. If the indoor unit is inclined, water may leak.
If space between bottom surfaces of indoor unit and ceiling is not correct, there may be a gap between the panel and indoor unit, with consequence dropping of condensed water.
!
CAUTION
Selecting the switch
1 Turn power off. 2 Remove cover of the electrical box. 3 When selecting discharge direction of 2 directions or 3 directions, select
the “AIR FLOW SELECTION” on the main PWB to 3 way.
When selecting discharge direction of 4 directions, select the “AIR FLOW
SELECTION” on the switch PWB to NORMAL.
NOTE:
During 2 directions or 3 directions, sound level will increase.
3
Corner Seal
Be sure that bottom face
of indoor main unit is the same height (or expected height if the ceiling is new construction.) as lower surface of the ceiling.
Selecting the switch
1 Turn power off. 2 Remove cover of the electrical box. 3 When install the indoor unit 2500mm or
more from the  oor, select the “STATIC PRESSURE SW” on the main PWB to HIGH PRESSURE.
When install the indoor unit below
than 2500mm from the  oor, select the “STATIC PRESSURE SW” on the main PWB to NORMAL.
If constructing the ceiling after installation
of air conditioner, be sure to attach a pattern paper for installation that shows ceiling opening dimension.
<
IA992: A
>
Holder for Remote Controller
RAI-25RPA RAI-35RPA RAI-50RPA
!
CAUTION
The installation height of indoor
unit must be 2.3m or more.
1
2
3
4
5
6
7
8
11
12
13
14
16
QtyNo. Item
1
Insulator
RAI-50RPA
17
Set nut and washer on suspension bolt and hook it to suspension clamp by lifting the
indoor unit.
Suspension bolt must have play of 20-30 mm on its right and left. If cannot have enough
play,  x lifting lug to suspension bolt without attaching nut underneath the suspension bolt, then attach nut and install indoor unit.
Make sure that indoor unit is kept level using a level.
The space between bottom surfaces of ceiling and indoor unit
Be sure to install the indoor units as follow position (1).
Do not install the indoor units as follows position (2) (3).
(1) Same level (draw in 0~2mm) (2) Stick out above 0mm (3) Draw in above 3mm
Selecting the Mounting Position
The installation place is very important for the air conditioner because it is very dif cult to move from one place to another after the  rst installation. Decide the mounting position together with the customer. The discharge direction can be selected as shown below.
Removal Of Air From The Pipe And Gas Leakage Inspection
Gas Leakage Inspection
Please use gas leakage detector to check if leakage occurs at the connection of Flare nut as shown on the right.
If gas leakage occurs, further tighten the connection to stop leakage. (Use the detector provided for R410A)
FINAL STAGE OF INSTALLATION
Insulation And Maintenance Of Pipe Connection
1
The connected terminals should be completed sealed with
heat insulator and then tied up with rubber strap.
Please tie the pipe and power line together with vinyl tape
as shown in the  gure showing the installation of Indoor and Outdoor units. Then  x their position with holders.
To enchance the heat insulation and to prevent water
condensation, please cover the outdoor part of the drain hose and pipe with insulation pipe.
If room humidity is high, cover the connecting pipe with
additional 5mm thickness insulator. This insulator shall be purchased from  eld.
Completely seal any gap with putty.
Installation Of Remote Controller
2
Power Source And Operation Test
3
The remote controller can be placed in its holder which is
 xed on wall or beam.
To operate the remote controller at its holder, please ensure
that the unit can receive signal transmitted from the controller at the place where the holder is to be  xed. The unit will beep when signal is received from the remote controller. The signal transmission is weaken by the  orescent light. Therefore, during the installation of the remote control holder, please switch on the light, even during day time, to determine the mounting location of the holder.
Power Source
CAUTION
!
Please make sure, that the power voltage is 220V-240V
within the operation voltage of the unit.
Please take under consideration, that the power capacity
from your house distribution box is high enough for operating your room air conditioner.
Operation Test
Please ensure that the air conditioner is in normal operating
condition during the operation test.
Explain to your customer the proper operation procedures
as described in the user’s manual.
3
Procedures of using Vacuum Pump for Air Removal
Preparation of Pipe
1
Use a pipe cutter to cut the copper pipe.
Jagged edge will cause leakage.
Point the side to be trimmed downwards during trimming to
prevent copper chips from entering the pipe.
Before  aring, please insert the  are nut into the pipe.
Pipe Connection
2
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
CAUTION
!
AIR REMOVAL
THIS APPLIANCE MUST BE EARTHED.
Wiring Of The Indoor Unit
(1) Remove the cover of the electric box. (2) Connect the connecting cords. (3) Assemble the cover of electric box.
Procedures of Wiring
CONNECTION OF POWER CORD
CAUTION
!
In case of removing Flare nut of a indoor unit,  rst remove a nut of small diameter side, or a seal cap of big diameter side will  y out.
Please be careful when bending the copper pipe.
Applied frozen grease to the connection points and then screw in
manually. After that, use a torque wrench to tighten the connection.
WARNING
!
Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the speci ed capacity.
Installation Of Optional Panel
4
Carefully read through the procedures of proper installation
before starting installation work.
<
IA992: A
>
Checking for the electric source and the voltage range
Before installation, the power source must be
checked and necessary wiring work must be completed. To make the wiring capacity proper, use the wire gauge list below for the wiring from a switch board of fuse box to the outdoor unit in consideration of the locked rotor current.
IMPORTANT
Fuse Capacity
16A time delay fuse
IMPORTANT
Cable length
up to
16m
up to 15m
up to 25m
Wire cross-section
1.5mm
2
2.5mm
2
4.0mm
2
The naked part of the wire core should be 10 mm and  x it to the terminal
tightly. Then try to pull the individual wire to check if the contact is tight. Improper insertion may burn the terminal.
Be sure to use only power cables approved from the authorities in your
country. For example in Germany: Cable type: NYM 3x1.5mm2.
Please refer to the installation manual for wire connection to the terminals
of the units. The cabling must meet the standards of electrical installation.
There is a AC voltage of 220-240V between the L and N terminals. Therefore,
before servicing, be sure to remove the plug from the AC outlet or switch off the main switch.
WARNING
!
When the meter reaches - 101KPa (-76cmHg) during pumping, fully tighten the shuttle.
Meter showing pressure
R410A Manifold valve
Vacuum pump
Valve
Charge hose
Valve
Vacuum pump adapter
When pumping starts, slightly loosen the  are nut to check of air sucked in. Then tighten the  are nut.
[For all optional part, please refer catalog for part number]
As for connecting to H-Link, a separately purchased RAC Adapter is required.
To install the wiring the electrical box cover must be opened.
Connect the connector of RAC adapter to CN1101.
Assemble back the cover of electrical box.
Please refer to the respective user manual of RAC Adapter for further details.
Please be careful not to damage lead wires by edge of plate when connecting the
optional parts.
[For all optional part, please refer catalog for part number]
Connection to the electrical box:
Remove the cover of electrical box.
Connect the connector of wired remote controller to CN1102.
Assemble back the cover of electrical box.
Please refer to the respective user manual of wired remote controller for further
details.
Please be careful not to damage lead wires by edge of plate when connecting the
optional parts.
WIRED REMOTE CONTROLLER
H-LINK
How To Connect The Optional Parts
(RAC Adapter, Wired Remote Controller)
CN1101
CN1102
RAC Adaptor cord
Wired remote controller cord
Outer Diameter mm (inch)
6.35 (1/4")
9.52 (3/8")
12.70 (1/2")
15.88 (5/8")
1.0 ~ 1.5
1.0 ~ 1.5
1.0 ~ 1.5
1.0 ~ 1.5
Clutch type
A (mm)
1.5 ~ 2.0
1.5 ~ 2.0
1.5 ~ 2.5
1.5 ~ 2.5
Wing nut type
Thickness
(mm)
0.8
0.8
0.8
1.0
0.0 ~ 0.5
0.0
~ 0.5
0.0
~ 0.5
0.0
~ 0.5
Flare tool for R410A
Clutch type
Conventional  are tool
Outer
dia.of pipe
6.35 (1/4")
9.52 (3/8")
12.70 (1/2")
15.88 (5/8")
6.35 (1/4")
9.52 (3/8")
12.7 (1/2")
Valve
head cap
Torque N·m
(kgf
·
cm)
14.0 – 18.0 (140 – 180)
33.0 – 42.0 (330 – 420)
50.0 – 62.0 (500 – 620)
63.0 – 77.0 (630 – 770)
19.6 – 24.5 (200 ~ 250)
19.6 – 24.5 (200 ~ 250)
29.4 – 34.3 (300 – 350)
12.3 – 15.7 (125 ~ 160)
Small dia. side
Large dia. side
Valve core cap
Small dia. side
Large dia. side
As shown in right  gure, remove the cap of valve core. Then, connect the charge hose. Remove the cap of valve head. Connect the vacuum pump adapter to the vacuum pump and connect the charge hose to the adapter.
Fully tighten the “Hi” knob of the manifold valve and completely unscrew the “Lo” knob. Run the vacuum pump for about 10~15 minutes, then completely tighten the “Lo” knob and switch off the vacuum pump.
2
Completely unscrew the spindle of the service valve (at 2 places) in anti-clockwise direction to allow the  ow of refrigerant (using Hexagonal Wrench key).
Re-cap the service valve and tighten using wrench. Check the cap’s periphery if there is any gas leakage. The task is then completed.
Remove the charge hose and tighten the cap of valve core. Check the cap’s periphery if there is any gas leakage.
4
5
1
3
The remote controller must be slide in the remote controller holder, in the direction as shown in the  gure, until it hooks at the lower end of the remote controller holder.
Screw (2 pieces)
Remote Controller Holder
Remote Controller
Loading...