FOR SERVICE PERSONNEL ONLY
330
310
(10)10
500
35
50
12
125
450mm
400mm
316mm
125mm
41mm
45mm
ø65mm
199mm
280mm
65mm
390mm
80mm
530mm
780mm
10mm
45mm
ø65mm
42mm
44mm
125mm
20mm
SAFETY PRECAUTION
• Read the safety precautions carefully before operating the unit.
• The contents of this section are vital to ensure safety. Please pay special attention to the following sign.
WARNING .......... Incorrect methods of installation may cause death or serious injury.
CAUTION .......... Improper installation may result in serious consequence.
Make sure to connect earth line.
This sign in the figures indicates prohibition.
Be sure that the unit operates in proper condition after installation. Explain to customer the proper operation and maintenance of
the unit as described in the user' s guide. Ask a customer to keep this installation manual together with the instruction manual.
WARNING
• Please request your sales agent or qualified technician to install your unit. Water leakage, short circuit or fire may occur if you do the
installation work yourself.
• Please observe the installation stated in the installation manual during the process of installation. Improper installation may cause
water leakage, electric shock and fire.
• Make sure that the units are mounted at locations which are able to provide full support to the weight of the units. If not, the units may
collapse and impose danger.
• Observe the rules and regulations of the electrical installation and the methods described in the installation manual when dealing
with the electrical work. Use cables which are approved official in your country. Be sure to use the specified circuit. A short circuit and
fire may occur due to the use of low quality wire or improper work.
• Be sure to use the specified cables for connecting the indoor and outdoor units. Please ensure that the connections are tight after the
conductors of the wire are inserted into the terminals to prevent the external force is being applied to the connection section of the
terminal base. Improper insertion and loose contact may cause over-heating and fire.
• Please use the specified components for installation work. Otherwise, the unit may collapse or water leakage, electric shock, fire or
stronger vibration may occur.
• Be sure to use the specified piping set for R410A. Otherwise, this may result in broken copper pipes or faults.
• When installing or transferring an air conditioner to another location, make sure that air other than the specified refrigerant (R410A)
does not enter the refrigeration cycle. If other air should enter, the pressure level of the refrigeration cycle may increase abnormally
which could result in a rupture and injury.
• Be sure to ventilate fully if a refrigerant gas leak while at work. If the refrigerant gas comes into contact with fire, a poisonous gas may
occur.
• After completion of installation work, check to make sure that there is no refrigeration gas leakage. If the refrigerant gas leaks into the
room, coming into contact with fire in the fan-driven heater, space heater, etc., a poisonous gas may occur.
• Unauthorized modifications to the air conditioner may be dangerous. If a breakdown occurs please call a qualified air conditioner
technician or electrician. Improper repairs may result in water leakage, electric shock and fire, etc.
• Be sure to connect the earth line from the power supply wire to the outdoor unit and between
the outdoor and indoor unit. Do not connect the earth line to the gas tube, water pipe, lighting rod or the earth line of the
telephone unit. Improper earthing may cause electric shocks.
• When finishing the refrigerant collection (pumping down), stop the compressor and then remove the coolant pipe.
If you remove the refrigerant pipe while the compressor is operating and the service valve is released, air is sucked and a
pressure in the freezing cycle system will build up steeply, causing an explosion or injury.
• When installing the unit, be sure to install the refrigerant pipe before starting the compressor.
If the refrigerant pipe is not installed and the compressor is operated with the service valve released, air is sucked and the
pressure level of the refrigeration cycle may increase abnormally which could result in a rupture and injury.
CAUTION
• A circuit breaker must be installed in the house distribution box for the direct connected power supply cables to the
outdoor unit. In case of other installations a main switch with a contact gap or more than 3mm has to be installed.
Without a circuit breaker, the danger of electric shock exists.
• Do not install the unit near a location where there is flammable gas. The outdoor unit may catch fire
if flammable gas leaks around it.
• Please ensure smooth flow of water when installing the drain hose. Improper installing may wet your funiture.
• An IEC approved power cord should be used. Power cord type: NYM.
THE CHOICE OF MOUNTING SITE (Please note the following matters and obtain permission from customer before installation.)
WARNING
• The unit should be mounted at stable, non-vibratory location
which can provide full support to the unit.
• The Outdoor unit must be mounted at a location which can
support heavy weight. Otherwise, noise and vibration will
increase.
WARNING
CAUTION
• No nearby heat source and no obstruction near the air
outlet is allowed.
• The clearance distances from top, right and left are
specified in figure below.
• The location must be convenient for water drainage and
pipe connection with the Outdoor unit.
INDOOR UNIT
• To avoid interference from noise, please place the unit and
its remote controller at least 1m from the radio and
television.
• To avoid any error in signal transmission from the remote
controller, please put the controller far away from highfrequency machines and high-power wireless systems.
Names of Indoor Components
No. Item Qty
Hanger
1
Screw for Hanger
2
(4.1 x 32)
Holder for Remote
Controller
3
AAA size Battery
4
The Length of Indoor Unit
Connecting Cord
above
1
6
1
0.9 m
When the power is
supplied from the
indoor unit, pull the
power cable from the
cable drawer at the
right or left side of
the indoor unit.
Cable drawer (right side)
Direction of Piping
2
Backward piping
from left
Screw for holder of
Remote Controller
5
(3.1 x 16)
Holder
6
Remote Controller
7
2
Connection
There are 6 directions allowed,
namely, backward piping,
backward piping from left,
1
horizontally piping from right,
horizontally piping from left,
vertically down from right, vertically
down from left.
1
Dimension of Mounting
Insulation sheet
8
Stand of the Outdoor unit
(unit : mm)
1
Bush
9
1
Drain Pipe
0
1
Switch Cover
A
Purifying Filter
B
The components of 9 & 0 are included
in the package of the outdoor unit.
1
above 100mm
1
above 300mm
above
1.6 m
Mounting
Stand
above 50 mm when
installed on the
ceiling of balcony
• Do not expose the unit under direct sunshine or rain.
Besides, ventilation must be good and clear of obstruction.
• The air blown out of the unit should not point directly to
animals or plants.
• The clearances of the unit from top, left, right and front are
specified in figure below. At least two of the above sides
must be open air.
• The installation height should be at least 2,300 mm or more
OUTDOOR UNIT
from the floor.
• Be sure that the hot air blown out of the unit and noise do
not disturb the neighbourhood.
• Do not install at a location where there is flammable gas,
steam, oil and smoke.
• The location must be convenient for water drainage.
• Place the Outdoor unit and its connecting cord at least 1 m
away from the antenna or signal line of television, radio or
telephone. This is to avoid noise interference.
Figure showing the Installation
of Indoor and Outdoor Unit.
above 50mm
Be sure to
completely
seal any gap
with putty.
about 0.45m
must not bend
about 300mm
Maximum pipe length 20m
above 200mm
CAUTION
Used in
horizontal piping
above 50mm
give clearance
as wide as
possible
above
200mm
above
50mm
above 50mm
2,300 mm or more
Plug (Procure locally)
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator is
insufficient, please use commercial
products.)
• The refrigerating machine oil is
easily affected by moisture. Use
caution to prevent water from
entering the cycle.
• The difference in height between
the indoor and outdoor unit
should be kept below 10m.
• The connecting pipe, no matter
big or small, should all be
insulated with insulation pipe and
then wrapped with vinyl tape.
(The insulator will deteriorate if
it is not wrapped with tape).
The connection of insulated drain
hose.
Inner diameter 16mm
Please use insulated drain hose for
the indoor piping (commercial
product)
1 Installation of Hanger, Wall Penetration and Installation of Protection Pipe
• The draining of the water container inside the Indoor unit can be done from the left.
Therefore the hanger must be fixed horizontally or slightly tilted towards the side of
drain hose. Otherwise, condensed water may overflow the water container.
Direct Mounting On The Wall
• Please use hidden beams in the wall to hold the hanger.
Visible outline of the
outdoor unit
Drain Hose
Procedures of Installation and Precautions
• Procedures to fix the hanger.
1.Drill holes on wall.
(As shown below)
Wall
INDOOR UNIT
• Procedures to fix the holder of remote control.
1.Drill holes on wall.
(As shown below)
Wall
Wall Penetration and Installation of Protection Pipe
• Drill a ø65mm hole on wall which is
slightly tilted towards the outdoor side.
Drill the wall at a small angle.
• Cut the protection pipe according to the
wall thickness.
• Empty gap in the sleeve of protection
pipe should be completely sealed with
putty to avoid dripping of rain water into
the room.
• Please ensure smooth flow of water
when installing the drain hose. Improper
installing may wet your funiture.
• An IEC approved power cord should be
used. Power cord type: NYM.
06K108_RAS-35_YH6_English.p65 11/13/06, 3:02 PM1
ø4.8mm
ø4.4mm
Line
Level
Weight
CAUTION
2 Screw for Hanger
1
Hanger
Wall hole
2.Push plug into the holes.
(As shown below)
1 Hanger
2 Screw
Wall
2.Push plug into the holes.
(As shown below)
3 Remote
Control
Holder
Indoor
Seal with
putty
Protection
pipe
Wall hole
Drain Hose
Screw the hanger at the
positions possibly near the
upper and lower hooks where
the indoor unit is hung. Use 4 or
more screws to fix the hanger.
3.Fix the hanger on wall with
Plug
(Procure
locally)
above 50mm
5 Screw
Plug
(Procure locally)
Outdoor
Seal with
putty
WALL
Sleeve of
protection
pipe
4.1 x 32 screw.
(As shown in figure below)
Ceiling
4.1 x 32 screw
WARNING
2-5mm
Be sure that the wire is not
in contact with any metal in
the wall. Please use the
protection pipe as wire
passing through the hollow
part of the wall so as to
prevent the possibility of
damaged by mouse.
Unless it seals completely,
any air with high humidity
flows from outdoor and any
dew may drop.
2 Installation Of The Indoor Unit
INSTALLATION AFTER CONNECTION OF REFRIGERATING PIPES
• The refrigerating pipe should be adjusted to fit into
Cutting Low Cover bush
• While installing the pipe from the right, left or
bottom side, use a knife to cut openings as
• The terminals of 2 connected pipes must be covered
shown in figure. Then smoothen the edges of
openings with a file.
• Connect the connecting cord after removing low
• After adjustment, fit the connecting cord and pipes
¡
PIPING FROM THE RIGHT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Openings
Openings
Preparation
• Connect connecting cord.
• Holder can be attached at the either of 2 places.
• Pull out the pipe, connecting cord and drain hose.
Installation
• Insert the pipe through the wall hole.
¡ The upper part of the Indoor unit is hanged on the
hanger.
™ The projection at the lower part of the Indoor unit is
hooked onto the hanger.
1
1
Hanger
Refrigerating
Pipe
Protection
Pipe
™
PIPING FROM THE LEFT SIDE (BACKWARD, DOWNWARD, HORIZONTAL)
Drain Hose
Connecting Cord
Lift the body
of the unit
upwards and
then force it
downwards.
Hanger
Projection
Preparation
Connecting cords, pipe and
drain hose must be laid
together with Vinyl tape.
Wall hole
Pipe
Cable
Drain layout of
backward piping
Drain hose
THE CONNECTION OF REFRIGERATING PIPE DURING
THE INSTALLATION OF INDOOR UNIT
Preparation To Install Refrigerating Pipes
• The refrigerating pipes and connecting cord
Installation
Hang the indoor unit onto the hanger. Use the temporary stand
at the back of the Indoor unit to push its lower part 15cm
forwards.
• Place the drain hose through the hole on the wall.
• Wrap the refrigerating pipes with insulation pipe after
• Connect the connecting cord after removing low cover.
Changed of Drain Hose and Installation Procedures.
•
Exchange the location of drain hose and drain cap while installing the pipe from the left side as
• After adjustment, the connecting cord and refrigerating pipes
shown in below. Be sure to plug in the drain hose until the insulating material folds upon itself.
• The projection of Indoor unit must hook to the hanger.
• Please use pliers to pull out the drain cap.
(This is an easier way to remove the drain
cap).
CAUTION
Insufficient insert may
result in water leakage.
Rib at the Indoor unit
Pipe
Cable
Drain layout of backward piping from left
• The connected terminals should be completed sealed
Drain cap
Drain cap
Drain Hose
•
Remove low cover
•
Insert drain cap up to the
location securely till the
cap stops.
CAUTION
Insulating
section of the
•
Push the pipe deeply until the insulating
section of the drain hose end gets over the
rib at the indoor unit side.
drain hose end
• Do not tie the terminals with the tape too tight.
• Please tie the pipe and power line together with vinyl
• To enhance the heat insulation and to prevent water
• Completely seal any gap with putty.
• The rubber strap used for fixing the insulator
should not be tied with great force. Otherwise,
this will damage heat insulation and causes
water condensation.
• Please pull the lower part of the Indoor unit
Pipe
Rubber strap tied
with great force
4 Installation of Drain Hose
outwards to check if the unit is hooked onto
the hanger. Improper installation may cause
vibration and noise.
• Transform the piping while holding down the
lower portion of pipe-support by hand.
Pipe
support
Transform after
bending downward.
the hole on the wall and then ready for further
connection.
with insulator used for terminal connection. Then the
pipes are wrapped with insulation pipe.
cover.
(Refer to "CONNECTION OF POWER CORD")
into the space available under the unit. Use holder to
hold them tight.
Please select the easier position.
transform and are attached.
Please bend at a small
radius to form an arc
connecting refrigerating pipe.
(Refer to "Connection of Power Cord")
are placed into the space available under the Indoor unit.
Wall hole
Drain hose
Connecting
cord
Refrigerating
pipe
Heat
insulation pipe
Pull this to the front during the
connection of refrigerating
pipe to ease task.
3 Heat Insulation and Finish of the Piping
with heat insulator and then tied up with rubber strap.
If any clearance or over-tightening may cause
condensation.
tape as shown in the figure showing the installation of
Indoor and Outdoor units.
condensation, please cover the outdoor part of the
drain hose and pipe with insulation pipe.
Bending upwards
CAUTION
Ditch
Condensed water
pond
You are free to choose the side (left or right) for the installation of drain
hose. Please ensure the smooth flow of condensed water of the Indoor
unit during installation. (Careless may result in water leakage.)
Condensed
water pond
Drain hose
Connecting
cord
Pipe
Insulation pipe (must be wrapped with
vinyl tape at every 120 mm)
The end of the refrigerating pipes are at
locations marked with “▼▼” symbol.
0.85m
Projection
Protection
pipe
Drain hose
Connecting cord
Insulation material for pipe
connection
Sleeve of
protection pipe
Putty
Holder
below
5mm
about 15cm
Holder
Hook
Connected
section
Putty
CAUTION
Be sure that the drain hose is
not loosely connected bend or
proper condition like left figure.
• Please mount the Outdoor unit of stable ground to prevent vibration and increase
30mm
10mm
70mm
30mm
10mm
30mm
10mm
30mm
10mm
10mm
30mm
10mm
10mm
70mm
10mm
50mm
10mm
50mm
of noise level.
• Decide the location for piping after sorting out the different types of pipe available.
• When removing side cover, please pull the handle after undoing the hook by pulling
it downward. Reinstall the side cover in the reverse order of the removal.
Please face this side (suction side)
of the unit to the wall.
Please remove side cover
when connecting the piping
and connecting cord.
Pull downward
CAUTION
• Do not touch the suction
port, bottom surface, or
aluminum fin of the outdoor
unit.
Failure to do so may cause
an injury.
CONDENSED WATER DISPOSAL OF OUTDOOR UNIT
• There is holes on the base of Outdoor unit for condensed water to exhaust.
• In order to flow condensed water to the drain, the unit is installed on a stand or a
block so that the unit is 100mm above the ground as shown figure. Join the drain
pipe to one hole.
• Cover the drain hole with a bush. To install the bush, put it on the drain hole as
shown in the figure and press the both sides of the bush to fit into the hole.
OUTDOOR UNIT
After installation, check whether the drain pipe and bush cling to the base firmly.
BASE
DRAIN HOLE
Push Push
9 BUSH
Outer diameter: 16 mm or more
• Install the outdoor unit horizontally and make sure that condensate drains away.
• In case of using in chilly area
Especially, in case that there are many snows by very cold in chilly area, condensed
water freezes on the base and may result not to drain. In this case, please remove
the bush and the drain pipe at the bottom of unit. (Left and center near discharge
portion of air, each 1 place). It becomes smooth drain.
Ensure that the distance from the drain hole to the ground is 250 mm or more.
above
100mm
9 BUSH
DRAIN HOLE
0 DRAIN PIPE
1 Preparation of Pipe
• Use a pipe cutter to cut the copper pipe and remove burr.
Trimming tool
Copper pipe
CAUTION
• Remove burr and jagged edge will cause leakage.
• Point the side to be trimmed downwards during trimming to prevent copper
chips from entering the pipe.
• Before flaring, please put on the flare nut.
Die
Outer A (mm) Rigid Flaring Tool
Diameter (Ø) For R410A tool For R22 tool
6.35 (1/4") 0 - 0.5 1.0
9.52 (3/8") 0 - 0.5 1.0
2 Pipe Connection
• In case of removing flare nut of a indoor unit, first remove
a nut of small diameter side, or a seal cap of big diameter
side will fly out. Free from water into the piping when
CAUTION
• Please be careful when bending the copper pipe.
• Screw in manually while adjusting the center. After that, use a torque wrench to
tighten the connection.
Wrench
INSTALLATION OF REFRIGERATING PIPES AND AIR REMOVAL
working.
• Be sure to tighten the flare nut to the specified torque with
a torque wrench.
If the flare nut is overtightened, the nut may be split after a
long period has passed, and may cause a refrigerant leak.
Flare nut
Small diameter side 6.35 (1/4") 13.7 – 18.6 (140 – 190)
Large diameter side 9.52 (3/8") 34.3 – 44.1 (350 – 450)
Small diameter side
Valve
head cap
Torque
wrench
Large diameter side
Valve core cap 12.3– 15.7 (125 – 160)
Die
• Please use
exclusive tool for
Copper pipe
Outer diameter
of pipe (ø)
refrigerant R410.
Torque N·m
(kgf·cm)
6.35 (1/4") 19.6 – 24.5 (200 – 250)
9.52 (3/8") 19.6 – 24.5 (200 – 250)
3 Remove of Air From The Pipe And Gas Leakage Inspection
Procedures of using Vacuum Pump for Air Removal
As shown in right figure, remove the cap
of valve core. Then, connect the charge
hose. Remove the cap of valve head.
1
Connect the vacuum pump adapter to the
vacuum pump and connect the charge
hose to the adapter.
Fully tighter the "Hi" shuttle of the manifold
valve and completely unscrew the "Lo"
shuttle. Run the vacuum pump for about
10-15 minutes, then completely tighten the
"Lo" shuttle and switch off the vacuum
pump.
2
• Loosen the spindle of the service valve
with small diameter by 1/4 turn and
tighten the spindle immediately after 5
to 6 seconds.
• Remove the charging hose from the
service valve.
When the meter reaches - 101KPa
(-76cmHg) during pumping fully
tighten the shuttle.
Charge
hose
Valve
When pumping starts, slightly
loosen the flare nut to check of
air sucked in. Then tighten the
flare nut.
The body of service
valve
AIR REMOVAL
Completely unscrew the spindle of the
service valve (at 2 places) in anticlockwise
3
direction to allow the flow of refrigerant
(using Hexagonal Wrench key).
Tighten the cap of valve head. Check the
cap's periphery if there is any gas leakage.
4
The task is then completed.
Gas leakage inspection
Please use gas leakage detector to check if leakage
occurs at connection of Flare nut as shown on the
right.
If gas leakage occurs, further tighten the connection
to stop leakage.
Cap of
valve core
Hexagonal
wrench Key
Meter showing
pressure
Closed
R410A
Manifold
valve
Valve
Vacuum
pump
adapter
Cap of valve
head
Cap of valve
head
Vacuum
pump
• THIS APPLIANCE MUST BE
WARNING
EARTHED.
Procedures of Wiring
When power supplies to Indoor Unit
Line cord
Indoor Unit
Connecting Cord
ø1.6 or ø2.0
Outdoor Unit
ø2.0
When power supplies to Outdoor Unit
Indoor Unit Outdoor Unit
ø1.6 or
ø2.0
Connecting Cord
Detail of cutting the connecting cord
Indoor Unit
Green + Yellow
Outdoor Unit
Green + Yellow
Detail of cutting the connecting cord
Indoor Unit
Green + Yellow
Outdoor Unit
Green + Yellow
WARNING
• The naked part of the wire core should be 10mm fix it to the terminal tightly. Then
try to pull the individual wire to check if the contact is tight. Improper insertion may
burn the terminal.
• Be sure to use only wire specified for the use of air-conditioner.
CONNECTION OF POWER CORD
• Please refer to the manual for wire connection and the wiring technique should
meet the standard of the electrical installation.
• There is an AC voltage drop between the LN terminal if the power is on. Therefore,
be sure to remove the plug from its socket.
WARNING
• Leave some space in the connecting cord for maintenance
purpose and be sure to secure it with the cord band.
• Secure the connecting cord along the coated part of the wire
using the cord band. Do not exert pressure on the wire as this
may cause overheating or fire.
Strip wires
Strip wires
Green + Yellow
Strip wires
Wiring of The Indoor Unit
• For wire connection of the Indoor unit, you need to remove the front cover, the low cover
under the body of the unit and terminal cover.
When power supplied to outdoor unit
• Power cannot be turned off using power switch.
Always keep the switch "off" and put the switch cover
on the power switch so that the power cannot be turned
on.
• Power cord is not necessary, store it in the lower-side space on the rear
side of indoor unit. When storing, warp the power plug with the vinyl bag
for the parts, etc. and seal with adhesive tape to prevent dust or dirt.
• Terminal A and B of indoor unit do not need to be connected.
• When power supplied to outdoor unit, power is not turned off by switching
the power of indoor unit to "off". In that case, please cut the breaker.
• Remove the cover from the terminal base and screw the cable.
Connecting cord
Connecting cord
Earth
After remove the screw
and terminal cover, and
put the connecting cords
and fix the terminal cover
with screw.
Terminal cover
Screw
• Wiring for the horizontal piping from the right side.
Not to interfere with the drain hose, fold the cable at the
drain hose side of the electric box as shown in the left
figure, and pass the cable just over the electric box and
Cable
Power
cord
Electric box
Form the cable properly so that the
low cover won’ t touch the cable in
installation.
pull it out.
Piping and drain hose layout
Pipe
Drain
hose
Securely screw in the power cord and
connecting cord so that it will not get loose
or disconnect.
Tightening torque reference value:
1.2 to 1.6 N·m (12 to 16 kgf·cm)
Excessive tightening may damage the
interior of the cord requiring replacement.
When putting two connecting cords
through the band.
Screw
Insulating plate
Cord band
Connecting cord
WARNING
After wiring the indoor unit, make sure
to reattach the terminal cover.
Cable
Pipe
Drain
Power cord
Method to remove the low cover
• Pull at the ¡ and ™ in the directions as shown by
arrows to remove the cover.
Wiring of the Outdoor Unit
• Please remove the side cover for wire connection.
• If you cannot attach the side plate due to the connection cord, please
press the connecting cord in the direction to the front panel to fix it.
• Be sure that the hooks of the side cover fixed in certainly. Otherwise water
WARNING
leakage may occur and this causes short circuit or faults.
• The connecting cord should not touch to service valve and pipes. (it
becomes high temperature in heating operation.)
Checking for the electric source and the voltage range
• Before installation, the power source must be checked and necessary wiring work must
be completed. To make the wiring capacity proper, use the wire gauge list below for the
wiring from house distribution fuse box to the outdoor unit in consideration of the blocked
rotor current.
IMPORTANT
Wire length Wire gauge
up to 6m 1.6mm
up to 15m 2.5mm
up to 20m 4.0mm
2
2
2
• Investigate the power supply capacity and other
electrical conditions at the installing location.
Depending on the model of room air conditioner to be
installed, request the customer to make arrangements
for the necessary electrical work etc.
The electrical work includes the wiring work up the
outdoor unit. In localities where electrical conditions
are poor, use of a voltage regulation is recommended.
• Install outdoor for the room air conditioner within the
reaching range of the line cord.
IMPORTANT
cover
Earth terminal
Fuse Capacity
16A time delay fuse
1 Power Source And Operation Test 2 Installation of Remote Controller
Power Source
WARNING
• Never remodel the power plug nor extend the long-distance
cord.
• Keep additional length for the power cord and do not render
the plug under external force as this may cause poor contact.
• Do not fix the power cord with U-shape nail.
• The power cable easily generates heat. Do not bring the
cable together with a wire or vinyl tie.
• The remote controller can be placed in its holder which is fixed
on wall or beam.
• To operate the remote controller at its holder, please ensure that
the unit can receive signal transmitted from the controller at the
place where the holder is to be fixed. The unit will beep when
signal is received from the remote controller. The signal
transmission is weaken by the fluorescent light. Therefore, during
the installation of the remote control holder, please switch on
the light, even during day time, to determine the mounting location
of the holder.
The controller must be hooked onto the hook at the lower part
of the holder. Push in the remote controller in the direction as
shown in figure below.
How to remove the front cover How to Attach the Front Cover
¡ Remove the front panel
• Please remove and attach the front panel by both hands.
¡ Check that the drain pan is securely attached.
™ After installing the front cover onto the unit, hook three claws
at upper side of the cover securely. Then, push the center of
the front cover to lock the claws.
£ Tighten the two screws.
• After opening the front panel by both hands.
1 Undo the right arm while pushing it inside.
2 Slide the front panel to right as shown in figure. Then remove
while pulling it to front.
Operation test
Screw (2 pieces)
• Please ensure that the air conditioner is in normal operating
condition during the operation test.
• Explain to your customer the proper operation procedures as
described in the user' s manual.
• If the indoor unit won't operate, check the cable for correct
connection.
• Turn on the lamp in the room where the indoor unit is installed
and check the remote controller for normal operation.
Remote controller
Force-cooling operation
• When the service switch
Holder for Remote
Controller
Screw
of the indoor unit is
After completing the service switch
operation, be sure to keep the
switch pressed for one or more
06K108_RAS-35_YH6_English.p65 11/9/06, 10:58 AM2
FINAL STAGE OF INSTALLATION
< S735 : A >
seconds and stop the force-cooling
operation.
pressed for 1 or more
seconds, the forcecooling operation starts.
Use this mode when
performing the failure
diagnosis or collecting
refrigerant into the
outdoor unit.
•
CAUTION
Cover
Service switch (If the switch is
pressed for one or more seconds, the
force-cooling operation starts. If the
switch is pressed for additional one or
more seconds, the operation stops.)
Do not operate the unit for more than 5 minutes
while the spindle of the service valve is closed.
™ Remove the filters.
£ After removing two screws, pull the center of the front cover
towards you and release the claws.
¢ Pull the side faces (lower sections) of the front cover towards
you as shown in the figure and remove the cover.
HOW TO REMOVE INDOOR UNIT
• Push up the [PUSH] sections at the bottom of the indoor unit and
pull the bottom plate towards you. Then the claws are released
from the stationary plate.
(The [PUSH] sections are indicated by 2 arrows in the right figure)
¢ Install the filter.
∞ Slide the shafts of the right and left arms on the front panel
along the steps to insert the shafts into the holes till they stop.
After checking that the shafts are securely inserted, close the
panel.
Hole
[PUSH] mark positions
Shaft
Step