Dust sensor is capable of sensing
the dusts in the air such as cigarette
smoke, house dust, pollen, etc.
Deodorizing filter
(Nano power deodorizing filter)
Set this filter to the back
side of the unit.
Humidity sensor P.E-15
Senses humidity.
Filter assembly
(Allergen-free, HEPA filter)
Set this filter to the front side of the
unit.
Pre-filter
Removes large size dust.
Indicator section
P.E-3
Panel
Odor sensor
Senses odor in the air.
P.E-14
Shutter
(air inlet)
Remote controller
Humidifying filter
Purifier
Remote controller pocket
Handle
Water
tank
手前
Tray cover
Water tray
Air outlet
Hand grip
E-2
Filter
Housed inside
the purifi er.
* Be sure to remove
this fi lter from plastic
bag before operating
the purifi er.
Air inlet (around the panel)
No air inlet on the
panel front face.
dust fi lter(x1)
deodorizing fi lter(x1)
Power plug
Power
cord
Provided Accessories
Pre-fi lter
(x1)(x1)(x2)(x1)
Remote controller
“AAA” R03
batteries for
remote controller
Humidifying filter
手前
P.E-OO shows a page with further description.
Operation Buttons and Indicators
Humidity Level
Indicates approx. humidity level in the
room during operation.
LowModerateHigh
Orange OrangeOrange OrangeGreen
P.E-10, 15
Airflow Level P.E-12
Indicates airflow rate during operation. (Indicator: Green)
Auto
: Airflow rate during auto operation
: Indicates eco operation is active.
When airflow rate is switched using the
airflow button on the remote controller, the
selected airflow rate is indicated.
: Silent
: Med
: Strong or Max (blinking)
Operation Mode P.E-11
Shows the operation mode.
Air Purify, Pollen, Strong
Deodorization
Indicator: Green
Humidify, Skin Moisturize
Indicator: Orange
Clean Humidifying
Filter
Shows the time to
clean the humidifying
filter. (Indicator: Red)
P.E-18
On/Off Button
Use this button to start or stop operation and to switch the operation mode.
Air Sensor
Level of air contamination detected by the
dust sensor and odor sensor is shown by
how the indicator is lit. (Indicator: Green)
P.E-14
P.E-14
Features / Name of Each Component / Operation Buttons and Indicators / Accessories
Infrared Remote Receiver
Receives remote control
signal.
Timer
The indicator is lit when
4-hour timer is set.
(Indicator: Green)
P.E-13
Remote Controller
Point the remote controller at the infrared receiver on the purifier when you operate.
The remote controllable distance is approx. 6m maximum when pointing the remote
controller squarely to the receiver.
On/Off Button P.E-10
Press this button to start or
stop operation.
eco Button
Press this button to start or
stop eco operation.
Max button P.E-13
Press this button to start
max operation.
Note
P.E-17
The remote control may not work in a room where inverter lighting apparatus or electronic quick
start lighting apparatus is used, or when the infrared receiver is exposed to direct sunlight.
If you operate the remote controller not pointing straight to the front face of the purifier, the sensitivity
will be reduced. Operate the controller from the place in front of the purifier whenever possible.
Airflow Button P.E-12
Press this button to switch
airflow rate.
Mode Button P.E-11
Press this button to switch
operation mode.
Timer Button P.E-13
Press this button to set
Off-timer.
Sensor Setting Button
Press this button to switch
sensor sensitivity.
P.E-16
E-3
Safety Precautions
Please read the following safety precautions carefully before using the air purifier.
To prevent injury to the user or other people and property damage, the following instructions must
be followed. Also read the precautions appearing in the text carefully to ensure proper use.
Definition of each indication
Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is
classifi ed by the following indications.
This symbol indicates the
WARNING
CAUTION
possibility of death or serious
injury.
This symbol indicates the
possibility of injury or damage
to property.
Meanings of Symbols
Indicates “warning or caution”.
Indicates “prohibition”.
Indicates a “must”.
WARNING
To Prevent Fire, Electric Shock and Injury
AC Outlet, Power Plug and Power Cord
Before cleaning and other maintenance, be
sure to unplug the power cord from AC outlet,
and never pull it out or insert it with wet hands.
Otherwise, it may cause electric shock or injury.
Be sure to hold the plug, not the power
cord, when unplugging it from AC outlet.
It may cause electric shock or short-circuit, resulting in a fi re.
Be sure to unplug the power cord from AC outlet when
leaving air purifi er unused for an extended period of
time. Also drain the water tank and water tray.
Otherwise, it may cause electric shock, fi re or unpleasant odor.
Securely insert the power plug into AC outlet.
Otherwise, it may cause electric shock, fi re, smoke
emission and ignition.
Remove dust of the power plug periodically using a dry cloth.
Otherwise, it may cause a fi re.
When you notice anything abnormal (water leakage, burnt
odor, etc.) stop the operation and unplug the power cord.
It may cause electric shock or fi re due to ground
leak or short-circuit.
If the supply cord is damaged, it must be replaced
by the manufacturer, its service agent or similarly
qualifi ed persons in order to avoid a hazard.
Do not use with a voltage other than 220-240V AC.
Otherwise, it may cause a fi re or electric shock.
Do not damage the power cord.
(Do not break, modify, forcibly bend, pull
or twist it. Also do not place any heavy
object on it or pinch it.)
Otherwise, it may cause a fi re or electric shock.
Do not use damaged power cord or power
plug, or loose socket.
Otherwise, it may cause electric shock,
short-circuit or ignition.
Clean
220-240V
Panel
Purifier
Power cord
Power plug
E-4
WARNING
Water Tank, Water Tray and Humidifying Filter
Do not operate the unit without setting any of the water tank, water tray and
humidifying fi lter in place.
Otherwise, it may cause injury or unit failure.
Do not use any detergent (neither kitchen nor laundry use) when cleaning the
water tank or water tray.
Ingredients of detergent may cause damage and subsequent water leakage, or
electric shock, injury or unit failure.
Do not carry the water tank by holding its handle.
Dropping the tank may cause inadvertent injury or other accident.
Do not disassemble the tank cap.
Otherwise, it may cause inadvertent accident such as small children swallowing it
by mistake.
Place of Use
Do not use in a humid place such as in bathroom.
It may cause electric shock or unit failure.
Do not place air purifi er near a hot object such as a heater.
It may cause unit failure or deformation.
Do not use in a place where soot of oil, such as machine oil, is fl oating in the air.
It may cause a crack or fi re.
Do not use air purifi er in a kitchen as a substitute of ventilating fan.
It may cause a unit failure.
Do not use in a place where any organic solvent or chemicals are used.
It may cause a discoloration, deformation or fi re.
Do not use the air purifi er in a place where a machine tool such as a grinder
and welder that produces sparks such as fl ammable dust is installed.
Sparks may cause fi re.
Handle
Water tank
Safety Precautions
Tank cap
Purifier Body and Panel
Do not use benzene or thinner when wiping or spray fl ammable gas such as
insecticides.
It may cause a crack, electric shock, catching of fi re and explosion.
Do not let air purifi er intake infl ammables, lit cigarettes or incense.
It may cause a fi re.
Securely hold the grip when carrying air purifi er.
Dropping it may cause injury or damage to it.
Miscellaneous
In case the unit becomes inoperative or anything abnormal such as smoke or
unusual odor is noticed, immediately unplug the power cord to prevent possible
accident and contact your dealer for check and repair.
It may cause electric shock or fi re due to ground leak or short-circuit.
Ventilate a room frequently if any heating appliance is simultaneously used with air purifi er.
Otherwise, it may cause carbon monoxide poisoning.
The appliance is not to be used by children or persons with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction.
Children should be supervised to ensure that they do not play with the appliance.
Never attempt to disassemble, modify or repair by yourself.
It may cause a fi re, electric shock or injury. (Contact your dealer for repair.)
Do not put your fi nger or any other object into air outlet and inlet.
It may cause injury or unit failure.
Do not submerge or splash water on the unit. Also avoid fi lling water directly into the unit.
It may cause electric shock or short-circuit.
Do not tilt or tip over the unit. Do not put your weight on the unit or step on it.
It may cause tipping over of the unit and injury or water leakage.
Do not install in unstable place or anywhere near infant child.
It may cause tipping over of the unit and injury.
Flammable
gas
E-5
Safety Precautions (Continued)
CAUTION
Miscellaneous
Securely hold the grip when carrying
air purifi er.
Damaging or dropping it may cause injury.
When you attach or detach the panel
and water tank, do it slowly and securely.
Otherwise, it may cause water leakage or
injury of fi ngers pinched.
Use dry cell batteries properly after
reading the precautions on them.
Renew water in the water tank daily using
tap water and clean the tank periodically
according to the instructions given in the
“Cleaning” section of this manual.
Continued use without cleaning may allow
propagation of molds or bacteria due to
dirt and water scale, producing unpleasant
odor. In rare cases, they may cause a
health risk to those who are hyperactive. In
such a case, please seek medical advice.
Only use fresh tap water
Otherwise, it may cause deformation or
degeneration of parts, unit failure or unpleasant
smell due to propagation of molds or bacteria.
Do not use hot water (over 40ºC), water
through water purifi er, alkali ion water, mineral
water, well water or the like. Do not put organic
solvent or chemicals into the water tank.
Do not drink, or let drink, water in the
water tank and water tray.
It may cause a health threat.
Do not leave the detached water tank
with its cap closed.
Inner pressure of the tank changes
according to ambient temperature change
and may cause water leakage or injury
due to deformation or damage.
Use a genuine fi lter for the Hitachi Air Purifi er.
Other fi lters may cause unit failure.
Do not operate the unit when
using fumigating (smoking) type
insecticide.
Using such insecticide will cause
chemicals to accumulate in the unit and
to be emitted by subsequent operation,
which can be harmful to heath.
After using insecticide, ventilate the
room well before running the purifi er.
Do not allow water to freeze.
Water tank may be damaged, causing
a risk of electric shock and unit
failure. Whenever freezing of water is
anticipated, drain the water tank and
water tray.
Do not use the purifi er having water
leakage trouble.
It may cause electric shock. When
water leaks, unplug the power cord
from AC outlet and ask for repair.
Do not carry the purifi er with its
water tank fi lled.
It may cause water leakage or injury.
If you carry the purifi er with fi lled water
tank, level of water in the tray will rise
and cause the water to overfl ow when
operated.
Drain the water tank and water tray
fi rst, and set them on the unit before
carrying.
Do not tip over or drop the water
tank when it is fi lled.
It may cause injury or result in deformed
or damaged tank. Hold the tank
securely when you fi ll it with water.
Do not look into the indicator.
It may cause injury to your eyes.
To Prevent Floor Scratches or Wall Stains
During Cleaning / Place of Use
During cleaning, lay a soft cloth on
the fl oor and place the purifi er and
detached components (panel, water
tank, water tray, etc.) on it.
Otherwise, it may cause scratches on
the fl oor.
When you pull out the water tray, be
careful not to scratch the fl oor with
bottom of the tray.
E-6
Do not use the air purifi er near the
wall that cannot be scrubbed such
as cloth-covered white wall.
The air purifi er will take in the
surrounding air and may produce local
stains.
Cautions on Use
Do not install in an unstable or sloped
place, or near any obstacles.
The unit may fall or drop,
resulting in damage or unit failure.
If the space between the unit and
floor remains humid, the floor
may get moldy.
Using the unit tilted may cause
water leakage.
Do not drag the unit on any floor susceptible
to scratches or on thick carpet.
It may cause damage on floor or carpet surface.
Do not run with filter detached.
No cleaning effect is
obtainable without filter.
Running without filter
may also cause unit
failure.
Do not directly fan animals and plants.
Air drafts may adversely affect them.
Do not place anything on the air purifier
body, and do not block the
air inlet or air outlet.
Acts of the sort may cause unit
failure.
Do not touch or move the unit (angle
or lift the unit) during operation.
Moving the operating unit may cause the fan to contact
the inner case, resulting in noise and possibly unit failure.
Do not place the purifier in a place exposed
to direct sunlight.
Safety Precautions Cautions on Use
Direct sunlight may
cause deformation,
discoloration or
malfunction.
Do not block or touch the infrared receiver,
odor sensor, Dust sensor or humidity sensor.
Infrared receiver may be stained
or damaged to reduce its
sensitivity.
Sensors may be degraded in
their sensitivity.
Do not install in a place where the air from the
purifier will blow directly on furniture, electric
appliance, wall or ceiling.
Humid air may cause stain
or deformation of furniture,
or may cause unit failure.
Ventilate closed room occasionally.
The air purifier does not have a ventilation
effect.
✽
The air purifier cannot
remove hazardous
substance in cigarettes
(carbon monoxide, etc.).
Do not subject remote controller to
impact.
Do not drop the remote
controller or step on it, and
do not place any object on
it. Doing so may cause unit
failure.
Do not subject water tank to impact.
Water may leak from the tank
to wet the floor. Also water
may drip from the tank cap to
wet the floor.
Do not use near television or radio.
Broadcast may be
interfered. Install the air
purifier 2m or more away
from such devices.
E-7
Preparations for Operation
Lay a soft cloth or the like beneath the purifier to protect the floor against scratch.
CAUTION
No cleaning effect is obtainable if the filter is installed with plastic bag. It may also be a cause of malfunction.
Do not tip over or tilt the purifier.
Setting Filter in Purifier
Remove the panel.
Place the unit on a level, stable surface.
Hold the panel at both sides, pull it
gently forward and then slightly upward,
and remove it.
Remove the pre-filter.
Remove the filter.
(There are dust filter and deodorizing filter.)
Remove the filter packed in a plastic bag from inside the unit.
Take the filter out of a plastic bag.
Remove the packing.
Install the Deodorizing filter.
Install the deodorizing filter so that its black surface
faces the front (white surface in the back).
(Perform the same procedure when replacing filter.)
Disengage the tabs of the
pre-filter (4 locations).
Be sure to remove the packing.
The back
(White)
front side(Black)
Insert the filter all the way until the label
(deodorizing filter position indicator) is hidden.
Be sure to take out the filter from a plastic bag.
Note
Do not block the filter front face with cloth or paper.
Same precautions should be taken for the dust
filter as well.
Install the dust filter
on the unit.
Insert the filter all the
way until the label (dust
filter position indicator) is
hidden.
Install the pre-filter on the unit.
Reinstall the panel on the unit.
Insert the two tabs on top of the
panel into the two holes on the unit.
Dust filter
Deodorizing filter
(Black surface)
White
surface
Pre-filter tabs
E-8
Gently push bottom of the panel until
it clicks to close it securely.
Insert into the hole.
Inserting Batteries into Remote Controller
ᚻ೨
Remove the battery
compartment cover.
Cover
(for Humidify Mode and Skin Moisturize Modes)
Filling Water Tank
Gently remove the water tank.
While pressing the upper part of the
water tank handle, lift it obliquely
upward, and remove the water tank by
supporting it in the bottom.
Handle
Insert batteries and close the cover.
Insert the provided two “AAA” R03 batteries
with the correct polarities as instructed.
Since the batteries are provided when shipped from
the factory, their lives may be shorter than brand-new
ones because of self-discharge.
Batteries are consumable
When replacing batteries, replace the two batteries simultaneously.
Only use two manganese batteries or two alkali batteries.
Do not mix them.
Remove the tank cap and fill fresh tap
water of normal temperature.
Rubber packing
Check that the tank cap is equipped
with a rubber packing.
Loosen
Tighten
Do not push in the
pin in the cap center.
Doing so may cause
water leakage.
Preparations for Operation
Hold the water tray.
Do not carry the water tank by holding its
handle. Instead, hold the tank with both
CAUTION
hands and carry it while keeping the tank
cap side up. When the water tank is wet,
wipe off water drops before carrying.
Pull out the water tray, check
that the humidifying filter and
tray cover are equipped, and
then retract the tray.
The humidifying filter absorbs water supplied
from the water tank for humidifying operation.
Humidifying filter
Water tray
Handle
Press the center pin of the tank cap, and check that it
comes back by spring.
Tighten the tank cap firmly, wipe off spilt water, and
check that there is no water leakage.
Wipe off water on the water tank handle if any.
The tank cap is a consumable part. P.E-28
(If it leaks water due to deteriorated rubber packing,
please purchase separately available part for
replacement.)
Set the water tank into the water tank
holder.
Be sure to handle the water-filled tank with both hands.
Press in the tank securely until it clicks. Inadequate
setting may cause the water tank to fall or result in water
leakage.
Pin
Tray cover
Water tray
Slowly pull out the water tray while lifting it
obliquely upward.
Do not set the water tank without having the water tray in place. Otherwise, the water tank may tip over.
When you pull out the water tray, be careful not to scratch the floor with bottom of the tray.
CAUTION
Note
Do not leave the detached water tank with its cap closed.
Inner pressure of the tank changes according to ambient temperature change and may cause water
leakage or injury due to deformation or damage.
Humidifying function works automatically when the water tank and water tray are filled with water.
If you do not need humidification, operate the unit without filling water in the water tank and water tray.
CAUTION
When you remove the water tank, water may
drip from the tank cap. Lay a dry cloth before
removing the water tank.
E-9