Hitachi EN-060224-1 User's Guide

Hitachi EN-060224-1 User's Guide

EN-060224-1

Hitachi America, Ltd.

AC VARIABLE FREQUENCY INVERTER

ENGINEERING NOTE

TYPE

Product Advisory

 

 

SUBJECT

SR/SK DIP-Switch Setting on Certain Production Dates

 

 

AFFECTED

SJ200-055xFU, L200-055xFU, SJ200-075xFU, L200-075xFU

MODELS

(x = L or H)

In all listed models produced before January 2006 (Date Code 0601 [YYMM] and LOWER), the setting of the SR/SK switch (controls whether input terminals are source or sink type) is incorrect compared to what is documented in the manual.

The correct factory default position for this switch should be “SR” (source) as shown in the manual. However, these units were shipped with the switch in the “SK” (sink) position.

All other ratings of SJ200 and L200 were shipped with the switch set correctly.

Customers who receive affected models will simply have to change the switch position to configure the unit for source inputs, per the manual. If they need sink inputs, obviously, they will not need to change the switch position.

A Product Advisory is included in the carton of January 2006 through March 2006 production, to help avoid confusion for any users who had received units from earlier production. After March, the advisory will no longer be inserted in the carton.

PGC - 2/24/06

Page 1 of 1

Loading...