SPLIT TYPE AIR CONDITIONERSPLIT TYPE AIR CONDITIONER
-
-
-
INSTRUCTIONINSTRUCTION
Hisense Corporation
MANUALMANUAL
This air conditioner provides with cooling, heating, and drying functions. Details of the functions are below; refer to
these descriptions when using the air conditioner.
Compact Size
This model is smaller than its predecessors and
yet offers the same capabilities.
Microprocessor Controlled Operation
The interior compartment of the remote control
unit contains several features to facilitate
automatic operation, clearly displayed for easy
use.
Simple One-touch Wireless Remote Control
The remote control unit has several features to
facilitate automatic operation.
12-Hour ON or OFF Timer
This timer can be set to automatically turn the
unit on or off at any time within a 12-hour period.
1-Hour OFF Timer
This timer can be set to automatically turn off
the unit after one hour.
Night Setback
Pressing this SLEEP button changes the setting
of the room temperature thermostat, allowing
you to set the temperature at whatever level
that you feel comfortable.
Automatic and 3-step Fan Speed
Auto/High/Medium/Low
Intelligence Frequency Conversation
environment temperature's change, the
With
microcomputer controls the output energy and
perform the quick, precise controlling of the
room's temperature.
Air Sweep Control
This function moves a flap up and down in the air
outlet, directing air in a sweeping motion around
the room and providing comfort in every corner.
Automatic Switching between Cooling and
Heating
This unit automatically switches between cooling
operation and heating operation according to
the difference between the room temperature
and the set temperature.
Hot start Heating System
Right from the start, the air is warm and
comfortable. This system prevents any cold
blasts at the beginning while the heat pump
warming up, or even defrosting.
Automatic Restart Function for Power Failure
Even when power failure occurs, preset
programmed operation can be reactivated once
power resumes.
Anti-Mold Filter
This unit is equipped with an anti-mold filter that
inhibits the growth of mold and bacteria.
High Power Running
Run with strong power and make you feel
comfortable quickly.
RZA-0-1000-906-SM-D
Contents
Pardon not to inform you if the contents of the manual changes.
Page
Alert symbol
Caution statements
Composition of the air conditioner
Operation guide
Care and cleaning
Tips for energy saving
Troubleshooting
Schematic diagram
1
2
3
8
16
18
18
19
Alert Symbols
WARNING
CAUTION
The symbol refers to a hazard or an unsafe practice which can result in
severe personal injury or death.
The symbol refers to a hazard or an unsafe practice which can result in
personal injury or product damage.
1
Caution Statements
1.We recommend that this air conditioner be installed properly by
WARNING
qualified installation technicians in accordance with the installation
instructions provided with the unit.
2.Before installation, check if the voltage of the electric supply in your
home or office is the same as the voltage shown on the nameplate.
WARNING
Avoid:
3.Do not install the air conditioner where there are fumes or flammable
gases, or in an extremely humid space such as a greenhouse.
4.Do not install the air conditioner where excessively high heat generating objects are placed.
To protect the air conditioner from heavy corrosion, avoid installing the outdoor
unit where salty sea water can splash directly onto it or in sulphurous air near a
spa.
1.All wiring must conform to the local electrical codes.
2.Each unit must be properly grounded.
3.Wiring must be done by a qualified electrician.
4.Consider the capacity of the electric current of your electrical kilowatt hour meter wires and socket before installation.
WARNING
CAUTION
1.Read this manual carefully before using this air conditioner. If you still have
any diffculties or problems, consult your dealer for help.
2.The air conditioner is designed to give you comfortable room conditions.
Use this only for its intended purpose as described in this instruction
manual.
3.Never use store gasoline or other flammable vapor or liquid near the
air conditioner¡°¡ª¡±it is very dangerous.
4.The air conditoner has no ventilator for intaking fresh air from
outdoors. You must open doors or windows frequently when you
use gas or oil heating appliances in the same room, which consume
a lot of oxygen from the air. Otherwise there is a risk of suffocation
in an extreme case.
1.Do not turn the air conditioner on and off from the power mains
switch. Use the ON/OFF operation button.
2.Do not stick anything into the air outlet of the outdoor unit. This is
dangerous because the fan is rotating at high speed.
3.Do not let the children play with the air conditioner.
4.Do not cool or heat the room too much if babies or invailds are
present.
2
Composition of the Air Conditioner
1.Diagram of Structure
Air intake grille
INDOOR UNIT
Air outlet
Remote
control
unit
OUTDOOR UNIT
Air outlet
NOTE
Remote Control Unit
Refrigerant Tubes
Outdoor(Condensing)Unit
This air conditioner consists of an indoor unit and an outdoor unit. You can
control the air conditioner with the remote control unit.
Air Intake
Air Outlet
Drain Hose
Drain hose
Refrigerant tubes
Air from the room is drawn into this section and passes
through air filters which remove dust.
Conditioned air is blown out of the air conditioner through
the air outlet.
The wireless remote control unit controls power ON/OFF,
operation mode selection, temperature, fan speed, timer
setting, and air sweeping.
The indoor and outdoor unts are connected by copper
tubes through which refrigerant gas flows.
The outdoor unit contains the compressor, fan motor, heat
exchanger coil, and other electrical components.
Moisture in the room condenses and drains off through this hose
3
2.Introduction of the Indoor ControI Unit
IMPORTANT:
Avoid using radio equipment
such as mobile phone near
(within 1m) the indoor unit.
Some radio equipment may
cause maIfunction of the unit.
INDOOR UNIT
OPERATING lamp
TIMER lamp
POWER lamp
POWER
TIMER
OPERATING
HIGH
POWER
lamp
If the troubIe happens, dis connect power and restart the
air conditioner after a few
minutes.
REMOTE CONTROL
receiver
POWER lamp
TIMER lamp
OPERATING lamp
HIPOWER lamp
ON/OFF button
REMOTE CONTROL receiver ON/OFF button
This section picks up infrared signals from the remote control unit
(transmitter)
This lamplights when the air conditioner is in the operation
mode.(But the compressor may not run at this time.)
This lamp lights when the system is being controlled by the timer.
This lamp lights when the outdoor unit is electrified.
This lamp lights when the air conditioner run efficiently.
This button is set for emergent state.Please use the remote control
unit to operate the air condition er in the common state. If you have
lost the remote control unit or it has trouble,
on/off you air conditioner.(See operation without the remote control
this button to turn
use
unit.)
4
3.Introduction of Display
Displayed when setting temperature
Simultaneous use energy
saving
Displayed when one-hour
OFF timer is enable
Displayed when setting timer
AUTO
1HOUR
SET TEMPSET TEMP
1小时
HOUR
A
AUTO
ON
OFF
AUTO
Symbols
C
Displayed when transmitting data
Displayed when temperature is shown
Displayed when temperature setting
is at the upper or lower allowable
limits
Displayed when Night Setback is
running
Displayed when main unit sensor is in
use
(1) Operation mode
AUTO
COOL
HEAT
MILD DRY
FAN
(2) Fan speed
Automatic operation
HIGH
MEDIUM
LOW
(3) Set temperature
16-30¡æ
When set to 28¡æ
Current temperature
indication
AUTO
AUTO
(4) Timer
12-hour ON Timer
12-hour OFF Timer
1-hour OFF Timer
(5) NIGHT SETBACK
(6) Confirmation of
transmission
(7) Flap angle indication
(8) Sweep indication
(9) Indoor unit sensor
(10) Simultaneous use energy
saving
C
ON
OFF
A
5
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.