Hioki MR8870-20 Measurement Guide (Memory Recorder)

Measurement Guide (Memory Recorder)
MR8870-20
MEMORY HiCORDER
May 2014 Edition 1 MR8870B980-00 14-05H

Introduction

Introduction
Thank you for purchasing the HIOKI "Model MR8870-20 Memory HiCorder." This Measurement Guide Memory Recorder E dition consists of some basic applica­tion examples. Before using the instrument, be sure to rea carefully.
d the Instruction Manual
1
Operation and Screen Types (p. 2)
Measurement Proced u r e (p. 4)
Commercial Power Mains Measurement (p. 6)
To Monitor for Abnormal Phenomena (p. 8)
To Measure Current (p. 10)
Describes the screen types and an overview of the operating keys
Describes procedures from measurement prepara­tion to analysis
Shows the method for recording 220 V commercial mains waveforms, and describes how to save data after measurement.
Describes how to record abnormal phenomena such as voltage drop like those that occur during electrical outages as an example type of phenome­na. Also describes continuous monitoring using the trig­ger function to record only particular phenomena, and
automatic saving while measuring.
Describes how to record current waveforms using a clamp-on probe, and how to use the scaling function to display current values.
Measuring RMS Waveforms (p. 11)
Analysis (p. 12)
The instrument records RMS waveforms f or com­mercial power supply (50 Hz,60 Hz) and DC signals.
View and calculate waveform measurement values using the A/B cursors.
2
Select the item to change.
Show available setting options.
Select the desired setting.
Changing screen contents
CF Card Slot
Logic Connector
External control terminals
AC Adapter Socket
CHARGE LED
USB Port
POWER Switch
Operating Keys
(Rear) Battery Compartment
Apply the new set­ting, or cancel it.
BNC Terminals
WAVE/DATA
Selects among waveform screen displays (p. 3).
SET
Displays the Settings screens, and switches among the screen tabs with each press (p. 3).
FILE
Displays file info rmation (p. 3).
GAUGE
Alternately displays and hides the measurement scale on the Waveform screen.
(Manual trigger)
Press to trigger manually.
ESC
Cancels changes to set­tings.
Cursor Keys
Moves the position of the cursor (blink­ing selection) on the screen.
ENTER
Accepts displayed settings.
KEY LOCK
Disables keypad operations. Press and hold the left and right cursor keys simul­taneously for three seconds to lock and unlock the keys.
Press to save data manual­ly (p. 7).
Press the center key to se­lect waveform scrolling or A/B cursor movement, then press the left and right cur­sor keys to scroll or move (p. 12).
Setup and display
Saving operations
Scroll waveforms and
read cursor values
Choose a screen
Start and stop measure­ment. The LED at the left lights green while mea­suring.
Start and stop
measurement
Operating Keys

Operation and Screen Types

Operation and Screen Types
The screen switches each time you press the key. Operational information is dis-
Waveform Screen Numerical Screen
Waveform/Numerical Screens
Settings Screens
Setting Screen Calc/Save Screen
Comment Screen System Screen
File Screen
Press the left/right cursor keys to se­lect between the Settings screens.
played along the bottom of the screen.
3
Operation and Screen Types
4

Measurement Procedure

Measurement Procedure
Before measuring, be sure to read the "Usage Notes" in the Instruction Manual.
Loading...
+ 14 hidden pages