Hioki LR5001 Operation Manual

LR5001
HUMIDITY LOGGER
Operation Manual
Thank you for purchasing the HIOKI LR5001 Humidity Logger.
This guide introduces the logger’s basic measurement procedure to first-time users.
Read First
Mar. 2021 Revised edition 3 LR5001B981-03 21-03H
21
Confirmation
LR6 alkaline battery
(Pre-installed in the log­ger.)
3
Settings
Option
1
Besides the LR9504 Humidity Sensor, you can also use an
optional temperature/humidity sensor. Use a sensor that is suit­able for your application.
1
2
3
4
2
3
4
1
2
3
4
Confirm package contents, and prepare needed items.
Logger and Accessories
LR5001
Instruction manual
Stand
Refer to this manual for operating procedure details, or when prob­lems occur.
This is the logger stand. See the Instruction Manual for details.
LR9504 Humidity Sensor (Cable length: Approx. 40 mm)
LR5091 Communication Adapter
(Includes LR5000 Utility Program CD [PC application software] and USB Cable)
Importing data to a computer requires the optional LR5091 Communication Adapter or LR5092-20 Data Collector
Display Example: Setting the recording interval to 10 minutes.
Display the settings, and select the setting item.
Configure the setting as needed.
Apply the new setting contents.
(The setting items are displayed as shown under Setting Display on page 2.)
Stop
[REC] disappears when
recording stops. If the stop method is set to [OFF], recording stops automatically when memory becomes full.
Hold the button for two seconds while recording (while
[REC] is dis-
played).
Note: Continue pressing the button until the
[REC] indicator changes from a blinking
to off state.
Preparations
Install the battery and connect the sensor to the logger.
Installing the Battery
Press the PUSH tab as shown, and pull the bat­tery cover back.
Install the battery as shown.
Align the holes in the battery cover with the projections on the back of the logger.
While confirming that there are no gaps, press with your fingers to close the battery cover.
When the battery is installed, the logger
turns on (there is no power switch).
Connecting a Sensor
Align the triangles on the plug body and in front of the cable jacks, and insert the plug securely. (Insert the protruded parts of the connecting cable into the holes of the device.)
Recording
Before recording, install the logger and perform pre-measurement inspection.
(See the Instruction manual for details.)
Start
From the Measurement display, hold
the button for two seconds.
Note: Continue pressing the button until the
[REC] indicator changes from a blink-
ing to off state. When the blinking stops and the data count is zeroed, recording starts.
After one second, the measurement display reappears.
Logger memory contains the data for two recording sessions. (Be aware that old data is erased when starting recording after two record­ing sessions.)
Data can be imported to a computer without stopping recording.
No measured value is displayed.
Is the sensor inserted the wrong way round? Is the sensor inserted as far as possible?
Verify the correct plug orientation, and insert it as far as possible. If the values are not displayed despite these mea­sures, the sensor and logger need to be inspected and repaired. Please contact your dealer or Hioki representative. Note: The maximum and minimum values are not displayed when the
recorded data count is 0.
The display is blank.
Is auto power saving enabled (set to ON)?
When enabled, the display blanks after 30 seconds of operator inactivity. Press any button or send a communication signal to turn on the display.
The [REC] indicator disappears even though recording has not
been stopped.
Is the stop method disabled (set to OFF)? With disabled, recording stops automatically when memory becomes full. To record continuously until stopped by the REC/STOP button, enable the stop method. (In this case, old data is overwritten when the memory becomes full.)
Recorded data has disappeared.
Does recording restart after stopping?
Note that if recording is accidentally restarted after stopping, data recorded prior to the last recording is automatically erased.
(The logger retains the data from both current and most recent prior recording operations.)
To erase logger memory
Erase using the PC Utility program. See the Instruction manual for details.
The battery is depleted too quickly.
Are you using the battery originally supplied with the logger? Are you using a zinc-manganese battery?
Install a new LR6 alkaline battery
(Returns to the mea-
suring display)
Channel 1 Measured value
Channel 2 Measured value
Channel 1 Measured value
Recorded data count
Channel 2 Measured value
Recorded data count
Channel 1 Maximum value
Channel 1 Minimum value
Channel 2 Maximum value
Channel 2 Minimum value
REC
Recording in progress
AL
Upper/lower threshold exceeded
ENDLESS
Stop method enabled
STAT
Recording mode enabled
MAX,MIN
Maximum and minimum values
DATA
Recorded data count
Setting Display
Recording Interval
Setting
Year Setting
Month Setting
Day Setting
Hour Setting
Minute Setting
Stop Method Setting
Recording Mode
Setting
Power Save Setting
Power Save
Battery life is extended when on (enabled). Default is on.
Recording Mode
When on (statistical recording), instanta­neous, maximum, minimum, and aver­age values are recorded at each interval. (Record statistical values) Battery life is shorter. Default is off.
Stop Method
Select what hap­pens when memory becomes full. When on, the oldest data is overwritten (Endless Recording), and when off, record­ing stops (One-Time Recording). Default is on.
Measuring Display
Operating Buttons
SET
Displays settings.
(-), (+)
Changes Measurement display contents. Changes setting values on the Settings display.
REC/STOP
Hold for two seconds to start/stop recording. From a setting display, switches to measurement display.
Setting Display:
Displays settings (recording interval, date and time, etc.)
Measuring Display:
Displays recorded data (measured values, recorded data count, etc.)
Indicators
Battery Status Indicator
Troubleshooting
HIOKI LR5001B981-03
EN
5
Importing and Displaying Data on a Computer
1
Installing the PC Application Program
1
3
2
Insert the
CD
LR5000 Utility Program Operating Requirements
• CPU 1 GHz or faster processor clock
• RAM 1 GB or more (32-bit), 2 GB or more (64-bit)
• OS Windows 7, Windows 10
• Library .NET Framework 4.5.2 or later
• Interface USB
• Monitor Resolution 1024 × 768 or higher
• Hard Disk At least 30 MB free space (Additional space is required for storing recorded data)
What if the PC Utility program cannot be installed?
• Be sure that the computer meets the above operating require-
ments.
• Carefully read "Installing the PC Application Program" in the
Instruction manual, and reinstall. Pay special attention to the following items.
1. Be sure to log in using an Administrator account.
2. Before installing, be sure to close any programs running on the computer.
2
Starting the PC Utility Program
Required Items: Supplied CD
From the Windows [Start] menu, select -[HIOKI
LR5000 Utility Software]-[LR5000 Utility] to
start the program.
The program starts automatically from the next Windows logon, and the icon appears in the task tray (notification area).
3
Importing (Saving) Recorded Data to a Computer, and Graph Display
1
or
Required Items: LR5091 or LR5092-20 and supplied USB cable
Connect to the com-
puter via USB cable
2
Data importing
begins automatically
Data is saved to a file.
3
The viewer starts up
automatically with a
graph displayed
Click [Start] to display the application list. Click [Windows System]-[File Explorer] to start Explorer.
ダブルクリック
Double-click [setup.exe] (SET UP file).
Double-click
1. Click
2. Click
PC Utility Program Features
Making Detailed Settings
Displaying Recorded Data in a Table
Configure settings on the LR5000 "Data Logger" series loggers, and on the LR5092-20 Data Collector. The PC utility program can access settings that cannot be accessed from the logger itself.
For example,
Set recording start/stop method and timing to start and stop
recording automatically at scheduled times (Timer Measurements).
Measurement data can be freely scaled for display (Scaling).
Set upper and lower thresholds so that measurements outside
of the range cause [AL] (Alarm) to appear on the logger screen (Alarm Judgment).
Add comments to measurement data.
Processing Recorded Data
2010/8/1 9:00 2010/8/3 17:00
Recording Start Recording Stop
Printing Recorded Data
Example Graph Printout
Organizing Recorded Data
Process data imported to the computer.
Freely scale for display (Scaling)
Calculate electric power easily
(using clamp logger measurement values)
Calculate energy cost easily
(using clamp logger measurement values)
Calculate operating rate
Integration
Calculate dew-point temperature
(using temperature/humidity logger measurement values)
Sort data imported to the computer.
Copy (files between folders)
Move (selected files between folders)
Delete (selected files)
Combine
(multiple recording files into one, and save with new file name)
Extract
(data for a specified period, and save with new file name)
See the Instruction manual for details.
HIOKI LR5001B981-03