Hilti X-HVB User Manual

X-HVB Shear Connector 3.8
= =
^ 40
^
40
= =
% 4 d or 600
^ 100
d
^ 50
^ 50
% 51
^ 50
^ 100 ^ 100
> 100
3.8.4 Installation instructions
Connector Positioning (metal decking ribs transverse to beam)
1. One to three HVBs per rib. 2 HVBs transverse or parallel to beam.
0
0
4
W
40
r
4
W
40
r
D
3. With one HVB per rib, the leg may be either centered in the rib or positioned to give a 40 mm clearance to the side of the rib
0
50≥ 5
100 100
5b. Spacings along the ribs (mm) (other decking
profiles)
Minimum spacing decking profiles with: w
/m < 0.7 and wr/hr< 1.8, the minimum
51
r
spacing is increased from 50 to 100 mm.
m = spacing of ribs
5a. Spacing along the ribs (mm) (2" and 3" U.S.
composite floor deck profiles)
Connector Positioning (ribs parallel to beam and solid slabs)
4d or 600
50
100
3.8.5 Ordering Information
4. With two or three HVBs per rib, the legs may be either centered in the rib or alternated about the center.
50 mm, however for
6. If the decking has a stiffener in the rib bottom, position the HVBs against the stiffener.
HVBs may be placed with zero clearance to edge of flange.
Hilti, Inc. (US) 1-800-879-8000 | www
X-HVB Shear Connectors
Description Qty/Pkg
X-HVB80 250 X-HVB95 250 X-HVB110 250 X-HVB125 200 X-HVB140
.us.hilti.com
I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www
200
Setting Equipment for X-HVB Shear Connectors
Description
X-76-F-HUB Baseplate X-76-P-HUB Piston X-76-PS Stop Ring
.ca.hilti.com
I Pr
echnical Guide 2006 67
oduct T