X-HVB Shear Connector 3.8
3.8.4 Installation instructions
Connector Positioning (metal decking ribs transverse to beam)
1. One to three HVBs per rib. 2 HVBs transverse or parallel to beam.
0
0
≥ 4
W
≥ 40
r
≥ 4
W
≥ 40
r
D
irect Fastening Systems
3. With one HVB per rib, the leg may be either centered in the rib or
positioned to give a 40 mm clearance to the side of the rib
0
≥ 50≥ 5
≥ 100 ≥ 100
5b. Spacings along the ribs (mm) (other decking
profiles)
Minimum spacing
decking profiles with:
w
/m < 0.7 and wr/hr< 1.8, the minimum
≤ 51
r
spacing is increased from 50 to 100 mm.
m = spacing of ribs
5a. Spacing along the ribs (mm) (2" and 3" U.S.
composite floor deck profiles)
Connector Positioning (ribs parallel to beam and solid slabs)
≤ 4d or 600
≥ 50
≥ 100
3.8.5 Ordering Information
4. With two or three HVBs per rib, the legs may be either centered in the rib or
alternated about the center.
≥ 50 mm, however for
6. If the decking has a stiffener in the rib bottom,
position the HVBs against the stiffener.
HVBs may be placed with zero clearance to
edge of flange.
Hilti, Inc. (US) 1-800-879-8000 | www
X-HVB Shear Connectors
Description Qty/Pkg
X-HVB80 250
X-HVB95 250
X-HVB110 250
X-HVB125 200
X-HVB140
.us.hilti.com
I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www
200
Setting Equipment for X-HVB
Shear Connectors
Description
X-76-F-HUB Baseplate
X-76-P-HUB Piston
X-76-PS Stop Ring
.ca.hilti.com
I Pr
echnical Guide 2006 67
oduct T