Fingerprint Access Control Terminal
Quick Start Guide
UD12126B-B
©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
It includes instructions on how to use the Product. The software embodied in the
Product is governed by the user license agreement covering that Product. About this Manual
This Manual is subject to domestic and international copyright protection. Hangzhou
Hikvision Digital Technology Co., Ltd. (“Hikvision”) reserves all rights to this manual.
This manual cannot be reproduced, changed, translated, or distributed, partially or wholly, by any means, without the prior written permission of Hikvision.
Trademarks and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applications for the same by Hikvision and/or its a liates. Other trademarks mentioned in this manual are the properties of their respective owners. No right of license is given to use such trademarks without express permission.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, IS PROVIDED “AS IS”,
WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR
IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF THIRD
PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR
AGENTS BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN
CONNECTION WITH THE USE OF THIS PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL
BE WHOLLY AT YOUR OWN RISKS. HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF
REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN
YOUR JURISDICTION BEFORE USING THIS PRODUCT IN ORDER TO ENSURE THAT YOUR
USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT
THAT THIS PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Data Protection
During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices incorporates privacy by design principles. For example, for device with facial recognition features, biometrics data is stored in your device with encryption method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protection laws and regulations, including without limitation, conducting security controls to safeguard personal data, such as, implementing reasonable administrative and physical security controls, conduct periodic reviews and assessments of the e ectiveness of your security controls.
1 Appearance
USB Interface
Fingerprint Recognition Area
|
|
|
|
155 mm |
|
Display Screen |
|
|
|
|
|
|
140 mm |
ESC |
|
|
OK |
|
1 |
2 |
3 |
|
|
Keypad |
|
|
|||
|
ABC |
DEF |
|
||
|
4 |
5 |
6 |
|
|
|
|
GHI |
JKL |
MNO |
|
|
|
7 |
8 |
9 |
0 |
|
|
PQRS |
TUV |
WXYZ |
|
Card Swiping Area |
30 mm |
|
|
|
|
|
|
|
OK Key |
Keypad Descriptions |
|
|||||
|
|
|
|
|
|
|
|
||||||
|
Exiting Key |
ESC |
|
|
OK |
OK Key: Press to confirm operations. Hold the key for 2 s to enter the login interface. |
|||||||
|
|
|
|
|
|
|
|||||||
Network Interface |
Direction Keys |
|
|
|
|
Deleting Key: Press the key to delete the entered letter or number. |
|||||||
|
|
|
|
|
|
Deleting |
Doorbell Button: Press the doorbell button and the doorbell rings. |
||||||
|
|
|
1 |
2 |
3 |
Exiting Key: |
Press |
the key to exit the menu. |
|||||
|
|
|
ABC |
DEF |
|
||||||||
|
|
|
|
|
|
Key |
Direction Keys: Press |
, |
, |
and |
to move the cursor. |
||
|
|
|
4 |
5 |
6 |
Doorbell |
|||||||
|
|
|
Numeric Keys/Letter Keys: Enter numbers or letters. |
||||||||||
|
|
|
GHI |
JKL |
MNO |
||||||||
|
|
|
|
|
|
Button |
Key 0 can also represent a space key except you are using the number input method. |
||||||
|
|
|
|
|
|
|
|||||||
|
|
|
7 |
8 |
9 |
0 |
Editing Key: Press the key to enter the number 0. Hold the key to shift among |
||||||
|
|
|
PQRS |
TUV |
WXYZ |
|
|||||||
|
Wiring Terminal |
|
|
|
|
|
numbers/lowercases, numbers/uppercases and symbols. |
||||||
|
Numeric Keys/ |
Editing Key |
Notes: |
|
|
|
|
|
|
||||
|
|
Letter Keys |
|
|
|
1. The pictures here are for reference only. Some models do not support card swiping |
|||||||
Power Interface |
|
|
|
|
|
|
function. For details, refer to the actual products. |
||||||
|
|
|
|
|
|
2. If you enable the attendance status function, the OK key, the direction key, and the |
|||||||
|
|
|
|
|
|
|
exiting key can be the shortcut key of the attendance status. |
2 Installation |
|
|
M4 Expansion Bolt |
||
|
|
|
|
|
|
With Gang Box |
|
|
Without Gang Box |
||
Device |
|
Mounting |
Gang Box |
|
Expansion Sleeve |
|
|
|
|||
|
|
Plate |
|
|
|
|
|
|
2 |
1 |
|
|
|
|
|
|
|
|
|
120 mm |
|
4 |
|
|
|
|
|
|
|
|
|
|
|
|
Steps: |
|
|
68.1 mm |
|
Steps: |
1. Stick a mounting template on the wall at a required height, and drill 4 holes according to the mounting |
mm |
|
|
|
template on the wall. |
|
|
|
|
1. Install the gang box on the wall. |
||
130.6 mm |
|
36.5 mm |
|
Note: Make sure the gang box screw holes match the mounting plate’s. The gang box here |
Note: The suggested distance between the device lower edge and the ground is 1.3 m. |
|
|
|
2. Insert 4 supplied expansion sleeves of the setscrews (4_KA4×22-SUS) in the drilled holes. |
||
|
|
|
is for reference only. Select an appropriate gang box to install. The gang box is not supplied. |
||
83.65 |
53.2mm |
66.6 mm |
|
3. Fix and fasten the expansion bolts in the expansion sleeves respectively. |
|
|
The recommanded gang box dimension is 78 × 78 mm or 100 × 62 mm. |
||||
|
4. Align four holes of the device rear panel with the fixed screws and hang the device on the wall. |
||||
25.15mm |
|
||||
|
|
|
|
2. Fix the mounting plate on the gang box with two supplied screws (SC-PM4X10-IMP). |
Note: Reserve 5.2 mm to 5.5 mm of expansion bolts outside the wall for hanging the device. |
|
|
|
|
|
|
|
|
|
|
3. Route the device cable through the cable hole of the mounting plate and insert the cables |
Note: The additional force shall be equal to three times the weight of the equipment but not less than |
|
|
|
|
in the gang box. |
|
|
|
|
|
50 N. The equipment and its associated mounting means shall remain secure during the test. After the |
|
|
|
|
|
4. Align the terminal with the mounting plate, and secure the terminal on the mounting plate |
|
|
|
|
|
test, the equipment, including any associated mounting plate, shall not be damaged. |
|
|
|
|
|
with two supplied socket hexagon screws (SC-KM3X10_3-SUS). |
|
|
|
|
|
|
3 Activation
Activating via Device
Power on and wire the network cable after installation.
You should activate the device before the first login.
After powering on, the interface will be displayed as follows.
You can create the device password and confirm the password to activate.
Device Activation
Activation Password (8 to 16 Characters)
OK Next. |
Input Method |
[Number]
The default values of the terminal are as follows:
•The default IP address: 192.0.0.64
•The default port No.: 8000
•The default user name: admin
Activating via SADP
1.Download SADP Software: Get the SADP software from the supplied disk or the o cial website. Install and run the software.
2.Activate Device: Check the inactive device from the device list. Create a password in the right side of the interface and confirm the password.
3.Edit Device IP Address: Check the device and manually edit the device IP address, Port No., Subnet Mask, Gateway, etc.
Activating via Client Software
1.Get the client software from the supplied disk or the o cial website. Install and run the client software.
2.Click Device Management to enter the Device Management interface.
3.Select an inactive device from the Online Device list. Click Activate to pop up the Activation interface.
4.Create a password and confirm the new password. Click OK to activate the device.
5.Click Modify Netinfo to set the device IP address, mask address, gateway address, and port No.
STRONG PASSWORD RECOMMENDED–
We highly recommend you create a strong password of your own choosing (using a minimum of 8 characters, including upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product. And we recommend you reset your password regularly, especially in the high security system, resetting the password monthly or weekly can better protect your product.