HighPoint 4520 operation manual

Page 1
RocketRAID 4520/4522 Series
User Manual
November 16th , 2015 Revision 1.2 HighPoint Technologies, Inc.
1
Page 2
Copyright
Copyright © 2015HighPointTechnologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint Technologies, Inc.
Trademarks
Companies and products mentioned in this manual are for identification purpose only. Product names or brand names appearing in this manual may or may not be registered trademarks or copyrights of their respective owners. Backup your important data before using HighPoint's products and use at your own risk. In no event shall HighPoint be liable for any loss of profits, or for direct, indirect, special, incidental or consequential damages arising from any defect or error in HighPoint's products or manuals. Information in this manual is subject to change without notice and does not represent a commitment on the part of HighPoint.
Notice
Reasonable effort has been made to ensure that the information in this manual is accurate. HighPoint assumes no liability for technical inaccuracies, typographical, or other errors contained herein.
FCC Part 15 Class B Radio Frequency Interference statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifications not expressly approved by the manufacturer could void the user’s authority to
operate the equipment under FCC rules. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
European Union Compliance Statement This Information Technologies Equipment has been tested and found to comply with the following European directives:
European Standard EN55022 (1998) Class B European Standard EN55024 (1998)
2
Page 3
Table of Contents
Product Specifications ......................................................................................................... 5
RocketRAID 4520/4522 Overview ................................................................................... 6
What’s in the Box................................................................................................................... 7
Getting Started ....................................................................................................................... 7
Step 1: Setting Up the Hardware ...........................................................................................8
Step 2: Install/Update Drivers ...............................................................................................9
Step 3A: Install HighPoint RAID Management (WebGUI) .............................................. 15
Step 3B: Installing HighPoint Command Line Interface (CLI) (Windows / Linux /
FreeBSD) ................................................................................................................................... 19
Step 4A: Create RAID Arrays using WebGUI ................................................................... 20
Step 4B: Create RAID Array using RocketRAID BIOS (PC only) ................................... 23
Step 4C: Create RAID Arrays using CLI (Windows / Linux / FreeBSD) ...................... 29
Step 5: Initialize and format the RAID Array .................................................................. 30
Manage your RAID array ................................................................................................... 36
RAID Spare Pool ..................................................................................................................... 36
Email Notifications ................................................................................................................ 37
WebGUIRemote Login ........................................................................................................... 38
Storage Health Inspection (SHI) .......................................................................................... 40
Utilizing the Health Inspector Scheduler ......................................................................... 41
RAID Expansion (OCE/ORLM) .......................................................................................... 42
Updating RocketRAID HBA BIOS/Firmware ................................................................. 43
Updating BIOS/Firmware using WebGUI .......................................................................... 44
Updating BIOS/Firmware using a bootable USB ............................................................. 44
Troubleshooting – Hardware ............................................................................................ 45
PC hangs during Boot Up ..................................................................................................... 45
Troubleshooting - Software .............................................................................................. 46
WebGUI – Connection cannot be established .................................................................. 46
Troubleshooting – RAID .................................................................................................... 47
Critical Arrays ........................................................................................................................ 47
Disabled Arrays ...................................................................................................................... 48
Setting up a Bootable RAID ............................................................................................... 49
Battery Backup Unit (BBU, sold separately) .................................................................. 50
Online Array Roaming ....................................................................................................... 51
Tape Drive Module ............................................................................................................. 51
SAS Expander Compatibility ............................................................................................. 52
3
Page 4
Port Multiplier (PM) Compatibility .................................................................................. 54
Appendix A: NavigatingRocketRAID 4522 BIOS Utility (PC only) ........................... 55
Appendix A-1: System Tab .................................................................................................. 57
Appendix A-2: Disk Tab ....................................................................................................... 57
Appendix A-3: Array Tab ..................................................................................................... 59
Appendix A-4: Controller Tab ............................................................................................ 62
Appendix A-5: Window Tab ................................................................................................ 64
Appendix B: Navigating the HighPointWebGUI ............................................................ 64
How to Login HighPointWebGUI ........................................................................................ 65
Appendix B-1: Global Tab .................................................................................................... 66
Appendix B-2: Physical Tab ................................................................................................. 67
Appendix B-3: Logical Tab ................................................................................................... 70
Appendix B-4: Setting Tab ................................................................................................... 78
Appendix B-5: Recover Tab ................................................................................................. 80
Appendix B-6: Event Tab ...................................................................................................... 81
Appendix B-7: SHI (Storage Health Inspector) ................................................................ 82
Appendix C:WebGUI Icon Guide ...................................................................................... 83
Appendix D: RAID Level Reference Guide .................................................................... 85
Help ........................................................................................................................................ 86
HighPoint List of Recommended Hard Drives ................................................................ 86
Contacting Technical Support ............................................................................................ 86
4
Page 5

Product Specifications

RocketRAID 4522 Technical Specifications
I/O Processor
6Gb/s RAID-on-Chip
Cache Memory
512MB DDR3 Cache memory with ECC protection
Battery Backup Unit
Optional Battery Backup Module (HPTBBU-05)
Data Transfer Rate
Up to 6Gb/s per port
Number of Device Ports
8 6Gb/s SAS & SATA ports
Host Bus Interface
PCI Express 2.0 x8
Device Connector Type
Dual Mini-SAS Connectors
Onboard Indicators / Monitor
Alarm Buzzer Device Supported
Up to 128 SATA / SAS drives via SAS Expander, LTO Tape Drives
Backward Compatibility
Backward Compatible with HighPoint RAID HBA
Physical Form Factor
Low Profile
Dimensions
6.57” L x 2.68” H x 0.06” W
RAID Feature Suite
RAID 0, 1, 5, 6 , 10, 50, JBOD
Redundant RAID Configuration for Array availability
RAID Initialization Types
Background, Foreground and Quick
Native Command Queuing (NCQ)
Staggered Drive Spin Up
Spin Down Idle Disk
Enhanced data protection with Write Journaling feature
NVRAM keeps tracks I/O transaction logs
S.M.A.R.T Support
Auto Rebuild on spare drive
Hot-Plug and Hot-Swap support
Larger than 3 TB drive support
Bootable RAID Array support
Write Back or Write Through Cache support
DV Mode Performance Assurance Technology
Bootable RAID Array Support
Supports OCE / ORLM
4Kn Drive Compatible
Configuration Management Suites:
User friendly Browser-based Management Interface Easy to use BIOS configuration Tool Linux Command Line Interface (CLI) – Scriptable configuration tool
Supported Storage Expansion Options :
SAS Expander support, Thunderbolt Aware
Monitoring and Management Support :
SMTP, SES2, Event Log, SGPIO*, LED Status*. (* = RR4520 only)
Operating System Support :
Windows 7, 8, 8.1, 10 / Windows Server 2008, 2012, Major Linux Distributions (RHEL, CentOS, SLES, Fedora, Ubuntu and Linux Open Source Drivers), FreeBSD, Mac OS X 10.6.x and later (LTO support requires OS X 10.9.x and later)
Operating Temperature :
Work Temp:   . Storage Temp:    Relative Humidity:  non condensing.
Operating Voltage :
12 V / 3.3 V, Power: 11W
MTBF (Mean Time Before Failure):
920,585 Hours
5
Page 6
Certification Approval:
FCC, CE

RocketRAID 4520/4522 Overview

RocketRAID 4522 Key
PORT1
mini-SAS (SFF-8088) Connection Corresponds to channel 1-4
PORT2
mini-SAS (SFF-8088) Connection Corresponds to channel 5-8
BEEP
Alarm/Beeper
Figure 1. RocketRAID 4520
Figure 2. RocketRAID 4522
6
Page 7
J9
 Bus
PIN 1 is denoted by a square. PIN 2 and PIN 3 are to the right of PIN 1.
PIN 1
SCL
PIN 2
GND
PIN 3
SDA
J6
Battery Backup Unit (BBU) Connector
A1, A2
(RR4520)
Active LED pin
F1, F2
(RR4520)
Fail LED pin

What’s in the Box

Make sure the following items are included in your purchase:
RR4522 Host Bus Adapter (S/N sticker located on RocketRAID card) Driver CD Low profile bracket Quick Installation Guide
Note: Cables and Battery Backup Unit (BBU) are sold separately.

Getting Started

Thank you for purchasing HighPoint Technologies RocketRAID 4522. You are only a
few steps away from utilizing RAID storage using the industry’s most affordable
hardware RAID solution.
To start using your RocketRAID 4522 take the following steps:
1. Setting up the Hardware (pg. 8)
2. Install/Update drivers (pg. 9)
3. Install HighPoint RAID Management (WebGUI) (pg. 15)
4. Create RAID Arrays (pg. 20)
5. Initialize and format RAID Volumes (pg. 30)
7
Page 8

Step 1: Setting Up the Hardware

Ensure all items listed under Kit Contents are included in your package. For any discrepancy contact your reseller or submit a support ticket online at www.highpoint-
tech.com/websupport.
Preparing the RocketRAIDHBA (Host Bus Adapter)
The following instructions describe how to prepare your RocketRAID4522 HBA for use.
To install your RocketRAID4522:
Important: Before installing the RocketRAID4522 Controller, ensure that your system is powered OFF.
1. Locate a PCI Express 2.0 x8 slot (or compatible slot) on your PC or Mac Pro (old
version) motherboard.
Note 1: Refer to your PC or Mac Pro manual for instructions on how to
access your motherboard.
Note 2: Refer to your motherboard manual for instructions on how to locate
your PCI Express slot.
2. Align the RocketRAID4522 with the PCI Express slot and push straight down until
the card is fully seated.
3. Tighten the connection by fastening the RocketRAID bracket and enclosure
together with a screw.
4. Power on system and continue to Step 2: Install/Update Drivers
A PCI Expresss 2.0 x8 card is compatible with PCI Expresss 2.0 x16 and PCI Expresss
3.0 x16 slots. The following diagram shows how to install HBA to a PCIe slow on motherboards.
8
Page 9

Step 2: Install/Update Drivers

Installing drivers on a Bootable RAID Array
For instructions on how to install drivers during Windows OS installation refer to pg.
49.
Installing Drivers on an Existing Operating System
Drivers provide a way for your operating system to communicate with your new hardware. Updating to the latest drivers ensures your product has the latest performance, stability, and compatibility improvements. Drivers are updated regularly at www.highpoint-tech.com.
For Windows Users:
1. Download the latest driver files from our website www.highpoint-tech.com>
Support > Documents and Downloads >RocketRAID 4500 Series.
2. Extract the downloaded files onto your PC and note the location of the files.
3. Open Windows DeviceManager (Control Panel > Hardware and Sound > Devices
and Printers > Device Manager).
4. Under Other devices, right-click RAIDController.
5. Click UpdateDriverSoftware.
9
Page 10
6. Click Browse my computer for driver software.
10
Page 11
7. Navigate to where you saved the driver files.
8. Click OK.
9. Click Next, Windows security will prompt to ask if you are sure you want to install
HighPoint Software.
10. After clicking Install, driver will be installed.
11
Page 12
11. Reboot for changes to take effect.
For Mac Users:
1. Obtain latest driver online at www.hptmac.com
2. Click the downloaded file.
3. A mounted volume will appear on the desktop. Click the icon to open the volume.
4. Click the driver package to start installation (.pkg file)
12
Page 13
5. Follow the on-screen instructions of the installer.
6. Reboot computer for changes to take effect.
7. Make sure DriverInstalled is Yes
13
Page 14
Click Apple Icon > About this Mac> System Report > PCI
For Linux Users:
Users with Linux Kernel 3.9.4 or later have embedded RocketRAID 4500 series drivers in system, therefore do not need to install additional drivers. For users with older Linux kernel versions or driver compatibility issues, take the following steps:
1. Visit www.highpoint-tech.com> Support > Documents and
Downloads >RocketRAID 4500 Series.
2. Click Download located next to Linux opensource driver
3. Start Terminal and navigate to the directory containing the drivers.
4. Extract the folder contents using the following commands, for example:
gunzip RR3xxx_4xxx_Linux_Src_v1.10.0_15_06_04.tar.gz tar xvf RR3xxx_4xxx_Linux_Src_v1.10.0_15_06_04.tar
5. Read the README to verify the commands used to install the driver.
14
Page 15
6. Enter super user mode. Type make to build driver, then type make install
to install the driver.
7. Reboot.
For FreeBSD Users:
1. Visit www.highpoint-tech.com> Support > Documents and Downloads >RocketRAID
4500 Series.
2. Download the FreeBSD drivers and copy them onto a USB thumbdrive.
3. Mount the USB and extract the drivers, then copy the driver to
/boot/kernel/hptiop.ko.
# tar-zxvf xxx.tgz # cphptiop-xxx.ko /boot/kernel/hptiop.ko
4. To set the drivers to automatically load on startup, type the following command.
# echo ’hptiop_load=”YES”’ >> /boot/defaults/loader.conf
For more information, refer to the FreeBSD Manual at:
http://highpoint­tech.com/BIOS_Driver/rr4520/FreeBSD/rr4522/Install_FreeBSD_RR3xxx_4xxx.pdf

Step 3A: Install HighPoint RAID Management (WebGUI)

The HighPoint RAID Management (WebGUI) software is a useful tool used to create, maintain, and view your RAID arrays.
For Windows Users:
1. Download the latest WebGUI from our website at www.highpoint-tech.com>
Support > Documents and Downloads >RocketRAID 4500 Series
2. Extract and open the contents of the downloaded file.
15
Page 16
3. Double-click HighPoint RAID Management.exe.
4. Follow the on-screen instructions to complete the WebGUI installation
5. Double-click the HighPoint RAID Management desktop icon to start the WebGUI.
Alternatively, type http://localhost:7402 in your browser address bar.
16
Page 17
6. Your default web browser will open and prompt for a username and password
(Default username: RAID / password: hpt). Username and password are case­sensitive.
For Mac Users:
1. Download the latest WebGUI from our website www.highpoint-tech.com> Support >
Documents and Downloads >RocketRAID 4500 Series
2. Double Click the downloaded Mac WebGUI file.
3. Double click the HighPointWebGUI.pkg to start the WebGUI installer.
4. Follow the installer on-screen instructions to complete the WebGUI installation.
5. Double-click the HighPoint RAID Management desktop icon to start the WebGUI.
6. Your default web browser will open and prompt for username and password
(Default username: RAID / password: hpt). Username and password are case­sensitive.
17
Page 18
For Linux Users:
1. Visit www.highpoint-tech.com> Support > Document and Downloads >RocketRAID
4500 Series.
2. Navigate to Linux WebGUI and click Download.
3. Start Terminal and navigate to the downloaded files.
4. Extract the contents by typing the following commands (filename varies):
gunzip RAID_Manage_Linux_v2.3.1_14_10_20.tgz tar xvf RAID_Manage_Linux_v2.3.1_14_10_20.tar
5. Read the README.txt file for specific instructions on how to install.
6. Log in as root and type ./RAID_Manage_ Linux_v2.3.1_14_10_20.bin to install.
7. Reboot.
Uninstalling HighPoint RAID Management (WebGUI)
For Windows Users:
1. Open Control Panel.
2. Click Uninstall a program.
18
Page 19
3. Select HighPoint RAID Management to uninstall.
For Mac Users:
1. Navigate to /Applications/HPTWEBGUI/uninstall.
2. Click on the uninstall script.
3. Type in the Administrator password when prompted.

Step 3B: Installing HighPoint Command Line Interface (CLI) (Windows / Linux / FreeBSD)

The HighPoint CLI (Command Line Interface) is a command line utility that configures and manages HighPoint RAID controllers via command line. This is ideal for systems that cannot use the browser-based RAID management utility (WebGUI).
For Windows Users:
The HighPoint CLI software is bundled with the Windows platform WebGUI installation. Follow the steps outlined in step 3A to install the CLI.
To run CLI on Windows:
1. Run hptraidconf
2. Click hptraidconf to open a cmd terminal.
3. Input your username and password when prompted (default username: RAID /
password: hpt.)
For Linux Users:
For Linux users, the CLI is an included package withWebGUI.
To run CLI on Linux:
1. Visit www.highpoint-tech.com for the latest CLI management update.
2. Download and save the file onto your computer.
3. Navigate to the file in terminal and then read the README for installation
instructions.
4. Type ./RAID_Manage_Linux_2.3.1_14_10_20.bin (file name will vary) to
install.
5. Once finished typehptraidconf to start CLI.
6. Input your username and password when prompted (default username: RAID /
password: hpt).
19
Page 20

Step 4A: Create RAID Arrays using WebGUI

For both Mac and Windows users:
1. Login to WebGUI (Default username: RAID / password: hpt).
2. Once logged in, click the Logical tab.
3. Click Create Array:
Click Logical to go to create array page.
20
Page 21
4. The RAID creation page provides many features, options, and settings. Detailed
descriptions are provided on pg. 59.
5. Select RAID5 for Array Type. (RAID Quick Reference on pg. 85)
6. Set array name as “Tutorial_Array”.
7. Select QuickInit as the initialization method.
8. Select WriteBack as the CachePolicy for better disk write performance.
9. Select 64K as the BlockSize.
10. Select all 4 available disks.
11. Leave the Capacity, SectorSize, DVmode, and DiskCachePolicy settings at their
default values.
12. Click Create
Create Array page.
13. Once created, the WebGUI will acknowledge the array has been created and the
system will prompt you to initialize the new volume.
21
Page 22
(Mac OS X) Array successfully created.
New volume needs to be initialized before use.
(Windows) Array successfully created.
22
Page 23
(Windows) For Windows platforms, user will be prompted to initialize disks in Disk Management.
14. Tutorial_Array can now be seen under Logical Device Information. (Take note that
the OS name is HPT DISK 0_0; this will help identify which volume to initialize)
Tutorial_Array is now created and can be seen in Logical tab.

Step 4B: Create RAID Array using RocketRAID BIOS (PC only)

RAID arrays can also be created using the RocketRAID BIOS. To enter the RocketRAID BIOS press CTRL + H during PC boot up.
Legacy disks, or disks that contain previous partitions, have to be initialized before they can be used for RAID.
23
Page 24
4 Legacy disks are shown here.
Initializing Disks
Before initializing, you must make sure you have the disk panel selected. The gold frame represents your current selection. By default, you start on the disk panel.
1. Press ALT + W to access Window tab.
2. Select disk(s).
3. Use keyboard arrow keys to navigate and press Enter to select desired disk(s).
4. Once disks are selected, press ALT + D to activate disk tab.
5. Select Initialize.
24
Page 25
Four disks are selected and about to be initialized.
6. Press Enter.
7. A prompt will warn you that data will be erased.
8. Select Yes.
9. Once initialized, you can proceed to create an array.
25
Page 26
Create Arrays
1. Navigate to the disk panel (ALT + W, then press 1)
2. Select each disk you wish to include in your array
Each selected disk has (#) symbol on the left.
3. Press ALT + A to open array panel
4. Press Create:
26
Page 27
Press ALT+A to open menu, then select create.
5. Press Spacebar to navigate and make selections (TAB also navigates between
windows)
RocketRAID BIOS create array option menu.
6. Press Create (ALT + E)
7. A prompt about sector size will pop up,select a sector size (irrelevant for Windows
XP 64-bit and later.)
27
Page 28
8. Your created array will show up in the Array Window.
Array RAID5_00 has been created.
9. Exit the BIOS (ALT+X). Alternatively, ALT + S to open System Tab, then select Exit.
28
Page 29

Step 4C: Create RAID Arrays using CLI (Windows / Linux / FreeBSD)

Start your operating systems console such as command prompt (Windows). On the command line, type hptraidconf to start HighPoint CLI. Enter your login credentials when prompted (default username: RAID / password: hpt).
In order to see the devices connected to the controller, type querydevices.
The device ID gives the position of each drive and is needed to select which drive will be included in the array.
29
Page 30
To create a 4 disk RAID 5 array named Tutorial_Array input the following command:
HPT CLI > create RAID5 name=Tutorial_Array disks=1/1,1/2,1/3,1/4
To view the created array, type queryarrays.
For more HighPoint CLI information type help in the command line or refer to the documentation included in the software package.

Step 5: Initialize and format the RAID Array

Before using the newly created RAID array, you must initialize and format the new volume.
For Windows Users:
1. After creating the RAID array, open Windows DiskManagement.
2. Disk Management will ask to initialize unknown disks either in MBR format or GPT.
30
Page 31
(Windows) Disk Management asks to initialize the disks before use. As a general rule, select MBR for
disks less than 2TB and GPT for disks greater than 2TB.
3. Right click the new disk, and click properties.
4. In properties, check and make sure it is a HPT VD (HighPoint Virtual Disk).
31
Page 32
Disk properties show HPT VD 0-0.
5. Once the disk has been confirmed, right click the unallocated space and click New
Simple Volume.
Right Click unallocated space, then click New Simple Volume.
6. Follow the on-screen instructions to configure and format the drive.
7. Once finished, the new volume will receive a drive letter and be available for use.
32
Page 33
RAID array is now formatted as NTFS and drive letter E:
For Mac Users:
1. After creating a RAID array, click Initialize when prompted. (Note: If you ignored
the prompt, simply open Disk Utility).
Disk Utility for Mac.
2. In Disk Utility, select the Volume you created on the right, then click the Erase tab.
33
Page 34
3. Select the desired disk format and disk name then click Erase. (Note: All previous
data on disks will be erased.)
4. When finished, your new RAID volume will be available for use.
34
Page 35
(Mac) Tutorial_Array volume created and mounted on desktop.
For Linux Users:
1. After creating a RAID array, open your disk utility program to view the logical
volume.
2. Click Format drive to create an MBR or GPT partition table on the drive.
3. Click Format Volume to format the drive.
35
Page 36
4. Once formatted, the volume will be available for use.

Manage your RAID array

The following features allow you to monitor and maintain your arrays to prevent any critical failures from occurring:
Spare Pool (pg.36) Email Notifications (pg.37) SMART Monitoring (pg.40) Health Inspector Scheduling (pg.41)

RAID Spare Pool

Physical drives marked as a spare will automatically be added to a redundant RAID array (RAID levels 1, 10, 5, and 6) whenever there is a disk failure. Enabling this feature minimizes the chances of data loss since it reduces the time an array is in critical status.
Add/Remove Spare
Using WebGUI:
1. Log in WebGUI.
2. Click Logical.
3. Click SparePool.
4. Check the box for the disk you want as a spare from AvailableDisks.
5. Click AddSpare.
Disks added to the spare pool will show under SparePool and can be removed by checking the disk checkbox from SparePool> Click RemoveSpare.
Using RocketRAIDBIOS:
1. Navigate to the disk panel (Press ALT + W, then press 1).
2. Use keyboard arrow keys to select desired disk.
3. Press enter to confirm each selection.
4. Press ALT + D to open disk tab.
5. Select Toggle Spare.
Disks added to the spare pool will show under SparePool and can be removed by checking the disk checkbox from SparePool> Click RemoveSpare.
36
Page 37

Email Notifications

When enabled, all added recipients will receive an email notification for any event log entries. (More information about events refer to pg.81)
To set up email alerts:
1. Check the Enable Event Notification box.
2. Enter the ISP server address name or SMTP name.
3. Type in the email address of the sender (email account that is going to send the
alert).
4. Type in the account name and password of the sender.
5. Type in the SMTP port (default: 25).
6. Check support SSL box if SSL is supported by your ISP (port value will change to
465, refer to your ISP if you have a specific SMTP port.
Note: After you click ‘Change Setting’ the password box will become blank.
Adding Email Recipients
You can add multiple email addresses as receivers of a notice.
1. Type the email of the recipient in the E-mail text box.
2. Type the name of the recipient in the Name text box.
3. Check which type(s) of events will trigger an email in the respective EventLevel
check boxes.
4. (Optional) Click test to confirm settings are correct by sending out a test email.
5. Click add to add the recipient to recipient list.
6. The added recipient will display in under Recipients.
The email will send to your recipients the output recorded in the event log.
37
Page 38
Example event log email message.

WebGUIRemote Login

A user connected to a local network can remotely access the WebGUI using the IP address of the host device.
To obtain your IP address
For Windows Users:
1. Open a command prompt window on the host computer.
2. Type ipconfig.
3. Look for the section that contains your network adapter information.
4. Note the IP address.
Example: The IPv4 address is under Ethernet adapter Ethernet 4 and is 192.168.1.143
Note: Make sure Restrictto localhost access is disabled in WebGUISetting (Refer to
setting)
38
Page 39
You can then remotely access the WebGUI using any other computer that is in your local network by opening any web browser and typing http://{IP address of host computer}:7402 (default port is 7402).
For Mac Users:
1. Open a terminal window on the host computer (computer that is connected to the
RR4522.)
2. Typeifconfig.
3. Look for the connection that has status: active
4. Write the IP address located after inet:
Example: en2 has active status, the IP is 192.168.1.254
For Linux Users:
1. Open a terminal window on the host computer (computer that is connected to the
RR4522.)
2. Typeifconfig | grep ‘inet’
3. Write the IP address located after inet:
39
Page 40

Storage Health Inspection (SHI)

The Storage Health Inspector (SHI) monitors each individual disk’s health. Monitoring disk SMART attributes can prevent critical RAID failures from occurring.
This section covers the following:
Enabling SMART Monitoring Disabling SMART Monitoring Changing HDD Temperature Threshold
Enabling SMART Monitoring
To access the SMART attributes of an individual disk:
1. Log in to WebGUI (defaultuser: RAIDpassword: hpt).
2. Select the proper controller using the drop down menu on the top left.
3. Click the SHI tab.
4. Click SMART on the desired disk.
5. Click Enable to enable SMART monitoring.
Disabling SMART monitoring
You have the option to disable SMART monitoring on each individual disk:
1. Select the proper controller using the drop down menu on the top left.
2. Click the SHI tab.
40
Page 41
3. Click SMART on desired disk.
4. Click Disable.
Note: Disabling SMART will prompt the Storage Health Inspector to change the disk status to ‘Failed’. TheRocketRAID alarm will not alert you when this setting is disabled. Any potential warnings related to S.M.A.R.T attribute technology will not trigger.
Changing HDD Temperature Threshold
To ensure hard disk temperatures remain cool, enable SMART to monitor disk temperatures. In SHI, you can set a threshold so that the WebGUI or controller alarm (if enabled) can warn you when physical disks get too hot.
1. Log in to WebGUI.
2. Select the controller from the drop down on the top left.
3. Click SHI.
4. Type the desired harddisk temperature threshold (°).
5. Click Set.

Utilizing the Health Inspector Scheduler

The HealthInspectorScheduler (HIS) enables you to periodically check your disk/arrays to ensure they are functioning optimally.
41
Page 42
Creating a New Verify Task
All arrays will appear under New Verify Task
1. Log in to WebGUI.
2. Select the proper controller from the top left drop down.
3. Click SHI.
4. Click Schedule.
5. Select the array you want to schedule the verify task.
6. Type the name in TaskName entry box.
7. Choose whether you want to schedule.
One time verify task on specific date (YYYY-MM-DD) at (HH:MM:SS, 24-hr clock). Or a specific schedule you can adjust based on Daily, Weekly, or Monthly
options.
8. Click Submit.
9. Your entry will appear under TasksList.
Note: New Verify Task box only appears if you have normal status arrays. If you have a critical array, New Rebuild Task will replace New Verify Task.

RAID Expansion (OCE/ORLM)

Important: It is recommended to Verify/Rebuild your array before Expanding or Migrating. Once you start an OCE/ORLM procedure, you can stop the process but it must be resumed until completion.
To add more capacity to your current configuration, follow these steps:
1. Log in WebGUI
2. Select desired controller from drop down menu on top left
3. Click Logical
4. Click Maintenance for the array you want to change
Select a different RAID level to Migrate Select the same RAID level to Expand
42
Page 43
5. Important: Record all the physical drives currently in array.
6. Click ORLM
7. Select the physical drives you recorded earlier and the drives you want to add
8. Click Submit
Upon submission, you will receive a prompt stating ORLM created successfully.
The Logical Device Information for the migrating/expanding array will change status to migrating/expanding.

Updating RocketRAID HBA BIOS/Firmware

Having the latest BIOS ensures you have the latest firmware stability and performance improvements. Updating the BIOS may fix boot up or system resource issues; make sure to read the README before making any changes.
A few reasons as to why update BIOS/Firmware:
43
Page 44
BIOS resource issue
Inefficient BIOS code may cause your boot-up to hang during POST.
Compatibility fixes
Updating firmware may fix issues that occur when using new hardware
Bug fixes
Bugs that are discovered post release are fixed in subsequent updates.

Updating BIOS/Firmware using WebGUI

Keeping the firmware up to date ensures that your RAID controller the latest compatibility and performance updates.
1. Locate the latest firmware on our webpage at www.highpoint-tech.com.
2. Extract the contents of the file.
3. Refer to the readme (if included) to make sure you have the correct firmware for
your HBA Note: Your HBA name and properties can be found in the WebGUI > Physical Tab.
4. Locate the proper firmware file
5. Login to WebGUI, then click the Physical tab.
6. Under Update Firmware, click Browse and browse to your firmware file.
7. Click Submit.
8. Reboot for changes to take effect.

Updating BIOS/Firmware using a bootable USB

Create a bootable USB using a utility such as Rufus. Caution: Creating a bootable USB will erase all previous data stored on it.
1. Download the latest BIOS/Firmware file found at www.highpoint-tech.com
2. Extract the file contents onto the bootable USB
3. Read the README for instructions on how to flash the BIOS onto your hardware.
4. Reboot your computer into DOS mode by:
Setting boot priority to the bootable USB Removing all bootable drives (OS, CD Drives) from motherboard and leaving
only the bootable USB and RocketRAID card plugged in
5. Once in DOS mode, you should see a command line interface
44
Page 45
Bootable USB formatted with Rufus Utility, FreeDOS CLI (Command Line Interface)
6. Type in the command with the file you found in the README (ex. run go.bat on
command line)
7. Reboot

Troubleshooting – Hardware

If you face any hardware related issues involving the RocketRAID 4522 or disk drives, refer to the following sections for troubleshooting tips. For all other problems, submit a support ticket at www.highpoint-tech.com/websupport.

PC hangs during Boot Up

The most commons symptom for this problem is the lack of resources.
There are two methods to fix this problem:
1. Update your motherboard BIOS
2. Update your RAID Controller BIOS
Update Motherboard BIOS
To update your motherboard BIOS, refer to your motherboard manufacturer’s user
manual or website.
45
Page 46
Update RocketRAID BIOS
To update RocketRAID BIOS refer to either of these sections:
Using a Bootable USB to update BIOS. Updating the BIOS through WebGUINote: Press END to bypass the RocketRAID BIOS
splash screen so you can boot up windows and access WebGUI.

Troubleshooting - Software

If you face any software related issues involving the HighPoint RAID Management (WebGUI), refer to the following sections for troubleshooting tips. For all other problems, submit a support ticket at www.highpoint-tech.com/websupport.

WebGUI – Connection cannot be established

1. Check the connection of the card with its PCI Express slot. (PCIe 2.0 x8 for RR4522)
2. Check and make sure the cables are not faulty.
3. Check Device Manager (Windows) or System Report (Mac) to verify the device and
drivers are installed and detected by the OS
a. For Windows Users:
i. Open DeviceManager.
ii. Click on the StorageController tab.
iii. Check to see if RocketRAID 4522 SAS Controller is listed.
iv. If RocketRAID 4522 SAS Controller is not listed, check to see if
RAIDController is under Unknown devices.
v. If RAIDController is under UnknownDevices, re-install RocketRAID
drivers.
vi. If RAID Controllerisnot present, recheck your hardware and cables.
b. For Mac Users:
i. Click the Apple Icon on the menu bar.
ii. Click About this Mac > System Report.
iii. Click PCI.
iv. Check to see the Type: RAID Controller and Driver Installed: Yes.
v. If Driver Installed is No, re-install the drivers.
vi. If RAID Controller is not present, recheck your hardware and cables.
c. For Linux User:
i. Open Terminal.
ii. Typecommandlsmod | grep ‘hptiop’to check is driver is running.
iii. Typecommandmodinfohptiopto check driver information.
46
Page 47

Troubleshooting – RAID

Common scenarios for critical array status
Unplugging disk that is part of an array Bad sector detected on a disk part of the
array
Unrecoverable data during rebuilding Defective port or cable interrupts
rebuilding process
If you face any RAID related issues involving your RAID array, refer to the following sections for troubleshooting tips. For all other problems, submit a support ticket at
www.highpoint-tech.com/websupport.

Critical Arrays

When your disk is critical, that means your array as a whole is still accessible, but a disk or two is faulty (depending on your RAID level) is in danger of failing.
To recover from this situation,
1. Backup your existing data.
2. Identify which disk is faulty.
You can refer to the LED lights on the enclosure. Refer to the WebGUI Logical tab and Event tab.
3. Re-insert the faulty disk or replace with a new disk. Array will rebuild automatically if you enable auto-rebuild setting and you
simply reseated the faulty disk. Note: Click Rescan if array still does not rebuild automatically.
4. Once a new disk is added, add the new disk into the critical array.
Log in to WebGUI. Click Logical Tab. Click Maintenance>Adddisk> select the appropriate disk.
5. Rebuild should start automatically. If rebuild does not start, click ‘Rescan’ on the left hand panel.
Note: Rebuilding an array takes on average 2 hours per 1 Terabyte of disk capacity. The process will scan through the entire disk, even if you have very little used disk space.
Rebuild failed
If rebuilding fails to complete due to bad disk sector errors (check in the Event Log), there is an option to continue rebuilding on error in HighPointWebGUI.
47
Page 48
1. Log in to WebGUI.
2. Click Setting tab.
3. Under SystemSetting, change EnableContinueRebuildingonError to Enabled.
This option will enable rebuilding to ignore bad sectors and attempt to make your data accessible. It is important to backup immediately after backup is complete and replace or repair any disk(s) with bad sectors.
Critical array becomes disabled when faulty disk was removed
If this is the case, check to make sure you removed the correct disk. When you remove the wrong disk from a critical array, the array status may become disabled. Data is inaccessible for disabled arrays. Follow these steps to restore the previous state:
1. Shut down your PC.
2. Place all disks, including the removed disks, back to original array configuration.
3. Boot up PC.
4. Once array is back to critical status, identify the correct disk (using the event log)
and replace it.

Disabled Arrays

If two or more disks in your array go offline due to an error or physical disconnection your array will become disabled.
To recover a disabled array, using the ‘Recover Tab’ will yield the best results. To
utilize the Recover tab, you will need to insert the exact physical drives that are listed on the recover list. The goal of using recover is to get the RAID status back to critical/normal, allowing you to access and back up your data.
Recover with RAID Maintenance
Note: The recover function will only attempt to recover RAID information stored on your disks. Data integrity of the array will not be fixed, if previously corrupted. All disks in the original (disabled) array must be detected before performing a recover operation.
1. Log in to WebGUI.
2. Click Maintenance for the array that is disabled.
3. Click Recover.
Recover RAID with Recover Tab
Before using the Recover tab to recover your array, check to see if the RAID array is listed in your Recover List. Once you have confirmed the RAID array is listed under the Recover List, proceed to delete the disabled array.
48
Page 49
1. Log in to WebGUI.
2. Click Maintenance for the array that is disabled.
3. Click delete, to delete the disabled array.
4. Click Recover Tab.
5. Select the RAID configuration you just deleted.
6. Click Recover Array.

Setting up a Bootable RAID

For Windows Users:
Creating an array and then installing Windows OS onto the RAID configuration is a bootable array. Since you cannot use the conventional method of installing drivers, the drive must be loaded during installation.
Prepare the following items for installation:
Operating System Install CD Driver files for RocketRAID 4522 USB thumb drive
Set Array as Boot Device
It is recommended to set the RAID array as a boot device prior to installing Windows.
1. Enter RocketRAID BIOS during boot up (CTRL+H).
2. Navigate to settings using arrow keys.
3. Press Enter.
4. Press Enter again.
5. Select the desired RAID array.
6. You will return to the main screen once the flag is set.
Installing Windows on Bootable Array:
1. On first boot-up, press CTRL + H during the HighPointRocketRAID splash screen to
enter the BIOS RAID creation utility.
2. Create the array you want to install your Windows Operating System onto
3. With the array created, download the RR4522 drivers from www.highpoint-
tech.com and load them onto a USB. You will need to locate the files when
prompted to load drivers during Windows Installation
4. Start Windows Installation.
49
Page 50
5. When prompted WheredoyouwanttoinstallWindows? Click LoadDriver
6. When prompted, click Browse
7. Browse to your connected USB and driver files you downloaded
8. Click OK, and once loaded, you will see a list of drivers detected.
9. Select the HighPoint driver file
10. Click Next, and you should see the RAID arrays you created
11. Select the RAID array and click Next
12. Follow the Windows installation instructions to complete your installation
For Mac Users:
Note: User must update the RocketRAID EFI to support Mac booting function. (Refer to pg. 50)
1. You must have an existing installation of the Mac operating system installed.
2. Set up the RR4522 by following the steps outlined in GettingStarted.
3. Once an array is created, the logical volume can be seen by your operating system
4. Use a 3
drive onto the logical drive you just created.
rd
party disk cloning tool (eg. Carbon Copy Cloner) to copy your bootable
For Linux Users:
RocketRAID 4522 drivers are already embedded in Linux and a bootable Linux can be directly installed on the RAID array.

Battery Backup Unit (BBU, sold separately)

When you set your RAID array or HDD to utilize write back cache, you sacrifice reliability for performance. Utilizing Write Through cache allows you to safe guard your data from power related failures, but it will be much slower.
A BBU is primarily used to safe guard arrays utilizing write back cache. When a power failure occurs, the battery will provide enough power to maintain the data in the cache for however long the battery capacity is.
Attaching the BBU
The connection will be made directly on the RAID controller J6 pins.
Checking the Battery Status
1. Log into WebGUI
50
Page 51
2. Select the Controller the BBU is connected to
3. Select the Physical Tab
4. Charge status should be listed under Extended Information
5. For CLI, type query controllers

Online Array Roaming

One of the features of all HighPoint RAID controllers is online array roaming. Information about the RAID configuration is stored on the physical drives. If the RR4522 fails or you wish to use another RAID controller, the RAID configuration data can still be read by another HighPointRocketRAIDcard.

Tape Drive Module

The 4522 supports LTO Tape storage solutions.
1. Download the latest driver, BIOS, and WebGUI version for the RocketRAID 4522
from our website www.highpoint-tech.com
2. Direct Link: http://highpoint-tech.com/USA_new/series_rr4520-Download.htm
3. Download your preferred tape management software, such as P5 Archiware,
PrerollPost, LTFS, Yoyota, etc. The tape drive will be detected in the HighPointWebGUI but managing the drive must be done using tape management software.
Login to HighPointWebGUI and check if the tape drive is detected.
1. Login to WebGUI
2. Select the controller tape is connected to
3. Click Logical tab
51
Page 52
LTO-6 tape shows up in logical tab.

SAS Expander Compatibility

HighPointRocketRAID 4522 supports SAS Expanders which enables connectivity up to 128 hard drives.
Example:
WebGUI Physical Tab shows RocketRAID 4522 connected to an Areca 8026 SAS Expander.
52
Page 53
As a result, the Controller is able to detect 16 drives using only 1 Mini-SAS port on the RocketRAID HBA. Under Physical Device Information (Location), the 1 represents the
RR4522 port, E1 represents the SAS Expander unit, and 2…17 represents the additional
channels connected to the SAS Expander.
53
Page 54

Port Multiplier (PM) Compatibility

HighPointRocketRAID 4522 support port multipliers (PM) which enables connectivity of up to 40 hard drives.
Example:
Connected to 1 port on the RocketRAID 4522, the port multiplier split the signal to 4 other targets. Under Physical Device Information (Location), the 1 represents the
RR4522 port, E1 represents the port multiplier, and 2…5 represents the additional
channels connected to the PM.
54
Page 55

Appendix A: NavigatingRocketRAID 4522 BIOS Utility (PC only)

HighPointRocketRAID BIOS utility allows you to create, manage, and maintain your RAID arrays without the need to install HighPointWebGUI application.
During boot up, you will see a RocketRAID splash screen prompting you to press CTRL + H to enter the BIOS. The following keys will help you navigate through the menus, find information, and make adjustments to your RAID arrays.
RocketRAID Splash Screen. Press CTRL + H to enter BIOS
Default Screen upon entering BIOS.
55
Page 56
Table 1. Navigating the BIOS
Keyboard Arrow Keys
Navigate the menu bar
F10
Accesses the menu bar
TAB
Switches between windows
Enter
Make a selection
ALT + <highlighted key>
Selects Menu Item (Ex. System can be accessed with ALT + S
Spacebar
Make certain selections (eg. creating arrays)
ESC
Exits a selection menu
System
Exits the BIOS (ALT + X)
Disk
Displays disk Information Initialize disks Add disks to spare pool Unplugs disks
Array
Displays array information Create/delete/unplug arrays Verify array integrity Set boot flag
Controller
Displays RAID controller information Adjust controller settings
Window
View BIOS window panels
Help
www.highpoint-tech.com
Snapshot of RocketRAID BIOS menu bar
Table 2. Menu Bar Key
56
Page 57

Appendix A-1: System Tab

Information
Device Type: SATA or SAS Model Number Serial Number Firmware Revision Capacity (in sectors) Read Ahead (on/off) Write Cache (on/off) TCQ NCQ (on/off) Spin up mode
Press ALT + X to exit the BIOS.

Appendix A-2: Disk Tab

Access disk tab by navigating to disk and pressing enter, or press ALT + D.
57
Page 58
Initialize
Initializes selected disks
Toggle Spare
Adds selected disks to spare pool
Unplug
Ejects selected disks
Turn on/off write cache
Toggles disk write cache ability
Rescan
Triggers HBA to rescan
Identify Disk
If applicable, will light up identify LED.
Initializing Disks
First you must navigate to the disk panel. By default, you start on the disk panel.
1. Press ALT + W to access Window tab.
2. Select disk(s).
3. Use keyboard arrow keys to navigate and press enter to select desired disk(s).
4. Press ALT + D to activate disk tab.
5. Select Initialize.
Four disks are selected and about to be initialized.
6. Press Enter.
7. A prompt will warn you that data will be erased.
8. Select Yes.
9. Once initialized, you can proceed to create an array.
Adding Disks to Spare Pool
1. Navigate to the disk panel (Press ALT + W, then press 1).
2. Use keyboard arrow keys to select desired disk.
3. Press enter to confirm each selection.
58
Page 59
4. Press ALT + D to open disk tab.
Array Information
Will disk the following information on selected array:
Array name RAID type Cache Policy Block Size Sector Size Disk Members
Create/Delete/Unplug
Selected action will be performed on array
Verify
Initiates verifying array integrity
Start/Stop Task
Starts or stops the verifying/rebuilding process
Set boot
Sets boot flag on array
5. Select Toggle Spare.
Unplugging Disks
1. Navigate to the disk panel (Press ALT + W, then press 1).
2. Use the keyboard arrow keys and Enter to select desired disks.
3. Press ALT + D to open disk tab.
4. Select Unplug.
Turn On/Off Disk Write Cache
1. Navigate to the disk panel (Press ALT + W, then press 1).
2. Select desired disks.
3. Press ALT + D to open disk tab.
4. Select Turn on/off write cache.
Rescan
Triggers motherboard to rescan the connection

Appendix A-3: Array Tab

59
Page 60
Creating an Array
Array Type
Refer to RAID Level Reference Guide for information about different levels.
RAID 0, 1, 5, 6, 10, 50, and JBOD
Cache Policy
Write-back -Any data written to the array
will be stored as cache, resulting in better I/O performance at the risk of data failures due to power outages. Data will be stored as cache before it is physically written to the disk; when a power outage occurs, any data in the cache will be lost.
Write-through -Data written to an array is directly written onto the disk, meaning lower write performance for higher data availability. Without cache acting as a buffer, write performance will be noticeably slower but data loss due to power outages or other failures is significantly minimized.
Init Method
QuickInit- This option grants
immediate access to the RAID array by skipping the initialization process, but
1. Navigate to the disk panel (ALT + W, then press 1.)
2. Select each disk you wish to include in your array.
3. Press ALT + A to open array panel.
4. Press Create:
5. Press Spacebar to navigate and make selections (TAB also navigates.)
60
Page 61
it will delete all data. Note: Skipping initialization is generally not recommended since residual data on disks may interfere with new data in the future.
Foreground-The array initialization
process will be set at high priority. During this time array will be non­accessible, but initialization completion time will be shorter.
Background-The array initialization
process will have a lower priority. During this time array will be accessible, but initialization completion time will be longer.
KeepOldData - This option skips the
initialization process and all data on each physical disk of the array will be untouched.
Name
Create array name
Capacity
Designate array capacity
6. Press Create (ALT + E)
7. A prompt about sector size will pop up, select a sector size
8. Array will show up in the Array Window
Verifying your array
1. Navigate to the array panel (Press ALT + W, then press 2)
2. Select desired array to verify (only if you have more than 1 array. If you only have 1
array, verify will automatically start)
3. Press ALT + A to open array tab
4. Select Verify
5. You can Start/Stop the process by selecting start/stoptask
Array RAID0_00 has been created.
61
Page 62
Information
Provides certain controller information:
Product ID PCI Location IOP Model SDRAM Size Firmware Version Battery Installed Battery MB Installed Serial Number CPU Temperatures (Celcius) Board Temperature (Celcius) Controller voltage levels
Setting…
Configures certain settings:
Enable audible alarm Enable Staggered spin up Spin down idle disk (minutes) Enable automatic rebuild Continue Rebuilding on error INT13 support Use single BCV entry Stop on error
Enable Audible Alarm
Enables/Disables the RocketRAID controller alarm
Enable Staggered Spin up
(Default: Disabled) Enabling this setting
will force the card to power on each hard disk sequentially (2 seconds between disks). Check with your disk manufacturer if your drive supports this feature.
Setting Boot Array
1. Navigate to the array panel (Press ALT + W, then press 2)
2. Select desired array
3. Press ALT + A to open array tab
4. Press Set Boot
5. Window will close, reboot to confirm

Appendix A-4: Controller Tab

Controller > Setting Information
62
Page 63
Number of drives per spin up: Select the number of disks per spin up (eg. 2 drives powered on every 2 seconds.)
Delay between spin up (seconds): Time interval between spin ups.
Spin down idle disk (minutes)
Hard drives can be instructed to spin down when there is no disk activity for set period of time.
Enable automatic rebuild
When enabled, any new disk attached to the controller will automatically be used to rebuild a critical RAID array
Continue Rebuilding on error
Disk bad sectors can interrupt the RAID rebuild process. Enabling this option will allow rebuilding to continue, ignoring bad sectors.
Rebuild Priority: This setting determines how HBA resources should be directed towards repairing broken RAID arrays.
Provide INT13 support
INT13 is the HBA’s boot function
Use single BCV entry
When enabled (and if HBA hosts several logical disks) only the first disk will be reported to the motherboard BIOS.
This setting could be useful when bottom from a disk or array attached to your RocketRAID HBA.
Stop on error
(Default: Enabled) If disabled, the host
adapter BIOS menu will bypass array or device errors when booting the system
63
Page 64

Appendix A-5: Window Tab

Maximize
Makes Selected Panel (Disk or Array) fullscreen. You can press TAB to toggle between disks and array panels.
Restore
Restores default panel configuration
1. Disk
2. Array
Selects the panel you want to work with
Refresh
Refreshes panels
Tab Name
Function
Global View
View HBA (Host Bus Adapter) and Storage Properties
Physical
View Additional Controller properties Update BIOS/Firmware View disk properties Adjust selected disk behaviors
Logical
Manage and create RAID arrays
Setting
Adjust WebGUI controls settings
The Window is the default screen you see upon entering the BIOS. The Top panel shows all the physical drives detected, and the bottom panel shows all arrays created.

Appendix B: Navigating the HighPointWebGUI

The HighPointWebGUI management utility allows you to do several key things:
View general system overview (see pg. 66) Update firmware and BIOS (see pg. 67) Create and remove arrays (see pg. 70) Change enclosure settings (see pg. 78) Troubleshoot faulty drives (see pg. 81) Monitor disk health (see pg. 82)
64
Page 65
Event
Show WebGUI Event Log
SHI (Storage Health Inspector)
View and schedule S.M.A.R.T monitoring
Recover
Revert to previously created arrays
Logout
Logout of WebGUI
Help
Additional WebGUI documentation Online Web Support

How to Login HighPointWebGUI

You can reach the HighPointWebGUI log in page either by:
Double clicking on the HighPointRAIDManagement icon created on your desktop Opening your preferred web browser and typing http://localhost:7402in the
address bar.
The default username and password to login is
Username: RAID
Password: hpt
Username and Password are Case-Sensitive (Username is not changeable)
65
Page 66

Appendix B-1: Global Tab

The WebGUI Global view provides an overview of what each HighPoint controller card connected to your computer detects. It is also the first page you see when logging in.
Host Bus Adapter Properties Storage Properties
On the top left of the page is a drop down menu that allows you to select which controller you want to manage (if you have multiple HighPoint controllers connected).
HBA Properties
HostAdaptermodel: the model name of the controller. EnclosureCount: number of external enclosures detected. Physicaldrives: number of drives seen by the controller. LegacyDisks: number of Legacy disks connected. Legacy disks are physical drives
that have previous partitions stored on them.
Storage Properties
Totalcapacity: the combined capacity of each physical disk connected to controller. Configuredcapacity: the amount of space used for creating arrays. FreeCapacity: total amount of space unused.
66
Page 67

Appendix B-2: Physical Tab

The physical tab shows general and extended information about the controller you are using. Information about the firmware, BIOS, and operating temperatures are all located here. This information is useful for identifying what RAID controller model you have and to make sure you have the most updated version available.
The physical tab contains the following information:
Controller Information Extended Information Update Firmware Physical Devices Information
Controller Information: Lists the controller model name, BIOS version, and vendor.
Model Name: RocketRAID4522 SAS Controller BIOS Version: v1.12 (as of 5/5/2015) Vendor: HighPoint Technologies, Inc.
Extended Information: Gives you additional information concerning the HBA (Host Bus Adapter) in the enclosure
67
Page 68
IOP Model: IOP chip model number CPU Temperature: Displays computer temperature in Celcius (°C). Board Temperature: Displays the board temperature in Celcius (°C). SDRAM Size: SDRAM size of the HighPoint controller card Battery Installed: Battery Backup Unit information Firmware Version: Firmware version of the HBA SAS address: the SAS address
Update Firmware: Allows you to update the controller BIOS and firmware through the WebGUI.
The following properties are part of the PhysicalDevicesInformation box under the physical tab.
68
Page 69
Read Ahead
Enabling disk read ahead will speed up read operations by pre-fetching data and loading it into RAM.
Write Cache
Enabling write cache will speed up write operations.
NCQ (Native Command Queuing)
A setting that allows SATA disks to queue up and reorder I/O commands for maximum efficiency.
Identify LED
The Disk tray LED lights on the front panel can be toggled ON or OFF.
Rescan
Clicking rescan will immediately signal the controller to scan for any changes in the connection. Clicking this button will also stop any alarm if currently ringing.
Model – Model number of the physical drive Capacity – Total capacity of the physical drive Revision – HDD device firmware revision number ReadAhead* - (Enable/Disable) Disk read ahead Location – Device location (example: 1/2 states controller 1, slot 2) WriteCache* – (Enable/Disable) the disk write cache MaxFree – space on disk that is not configured in an array Status – (Normal, disabled, critical) status of the disk NCQ* – (Enable/Disable) Native Command Queuing (SATA disks only) SerialNumber – serial number of the physical disk IdentifyLED* – On/Off – toggle the IDENTIFY (RED) on the front panel Unplug – Safely ejects selected disk. Other methods of disk removal will trigger
alarm if enabled
* Disk properties that can be adjusted.
69
Page 70

Appendix B-3: Logical Tab

The Logical tab is where you are edit, delete, and maintain your RAID configurations, as well as, adding drives to your spare pool. The logical tab has the following settings:
Create Array Spare Pool Logical Device Rescan Beeper Mute
An array is a collection of physical disks that will be seen as one virtual drive by your Operating System (OS). The RocketRAID4522 controller is capable of creating the following array types:
70
Page 71
Array Type:
JBOD – Just a Bunch of Disks RAID0 - Striping RAID 1 - Mirroring RAID 5 – Rotating Parity bit RAID 1/0 – Striping of Mirrored Drives RAID 5/0 – Striping of Distributed Parity RAID6 – Double Parity Bit
71
Page 72
Each RAID level has its pros and cons based on the application you use it for (Note: Refer to RAID level Quick Reference)
ArrayName: the name that will be displayed in Logical Device Information (Default:
RAID_<level>_<array number>)
Initialization Method:
Keep Old Data: Opts to keep all the data on each drive untouched. Best for users
that already have HighPoint RAID data on the selected drives.
Quick Init: Grants immediate access to the array volume. This option will delete
previous user data, but will not build parity. Recommended for testing purposes only or when new disks are used. Not recommended for RAID 5, RAID 50, and RAID 6.
Foreground: The array initialization process will be set at high priority. During this
time array will be non-accessible, but initialization completion time will be shorter.
Background: The array initialization process will have a lower priority. During this
time array will be accessible, but initialization completion time will be longer.
Note 1: Initialization takes a significant amount of time (approximately 2 hours per 1 TB).
Cache Policy (Default: Write Back)
Write Back – Any data written to the array will be stored as cache, resulting in better I/O
performance at the risk of data failures due to power outages. Data will be stored as cache before it is physically written to the disk; when a power outage occurs, any data in the cache will be lost.
Write Through – Data written to an array is directly written onto the disk, meaning lower write performance for higher data availability. Without cache acting as a buffer, write performance will be noticeably slower but data loss due to power outages or other failures is significantly minimized.
Block Size (default: 64K)
[16K, 32K, 64K, 128K, 256K, 512K, 1024K are the supported block sizes]
This option allows you to specify the block size (also known as “stripe size”) for specific array types (RAID 0, 1, 5, 6, 10, and 50). Adjusting the block size allows you to tailor the array performance towards specific application. Consider the sizes of disk I/O data you are dealing with; as a general rule larger disk I/O may benefit from smaller block sizes, and smaller disk I/O may benefit from larger block sizes. A block size of 64 KB is recommended since it gives balanced performance for most applications.
72
Page 73
Capacity (Default: Maximum)
The total amount of space you want the RAID array to take up. When creating RAID levels, disk capacities are limited by the smallest disk.
Example Capacity calculation:
A RAID 5 organizes data in the manner shown below. All parity data will become unusable for the user and not included in the total disk capacity.
Disk 1
Disk 2
Disk 3
Disk 4
Data 1
Data 2
Data 3
Parity
Data 4
Data 5
Parity
Data 6
Data 7
Parity
Data 8
Data 9
Parity
Data 10
Data 11
Data 12
Therefore, RAID 5 capacity will be [SMALLEST DISK CAPACITY] * (number of disks – 1).
Sector Size (Default: 512B)
This option is irrelevant for Windows XP 64 and later. Current OS already support larger volumes, and introduce a partitioning method known as GPT (GUID partition table). This option, also known as VSS (Variable Sector Size) allows you to specify the sector size of the array, for use with older Windows Operating Systems.
DV Mode
This mode is specifically designed for video applications. The default firmware cache policy provides balanced performance for standard applications such as workstations, file servers, and web servers. But for DV mode, a special cache firmware is implemented specifically for large sequential writing (large I/O requests such as video files). Enabling DV mode will maintain the performance and consistency of transferring and processing video files.
There are several factors concerning DV mode to take note:
DV mode only available for RAID 0, 5, and 6 Only 1 RAID array you created can enable DV mode
DV mode only works when array status is normal
73
Page 74
Margin
[5% - 25%]
When DV mode is enabled, you have the option to set the margin. This percentage represents the amount of space the designated cache will hold before flushing the data onto the drive. Increasing the margin % will result in more stable performance, but decrease the maximum write performance.
Alternatively, you can change the margin anytime in Logical > Maintenance for DV enabled array.
Logical Device Information
Logical device tab is the default page upon clicking the Logical tab of the WebGUI. This page contains information about your RAID arrays and individual disks your system detects.
Logical Device Information
Arrays you create and the properties associated with them will appear here.
Maintenance
Once an array has been created, click maintenance for options to manage your array.
Array Information
Clicking on the maintenance button will show you the Array information box. Different array statuses (Normal, critical, disabled) will have different maintenance options.
74
Page 75
Normal Status
A Normal Status Array has the following options:
Delete – deletes the selected RAID array Unplug – powers off the selected RAID array Verify – verifies the integrity of the RAID array Change Cache Policy – Toggles between Write through and Write back cache Change Margin – Adjust margin when DV mode is enabled Rename – renames the RAID array OCE/ORLM – Online Capacity Expansion / Online RAID Level Migration
Critical Status
75
Page 76
A critical status array has all the normal status options except the following:
The Array can no longer be renamed Add disk replaces the verify disk option
Once array status changes to critical, the faulty disk will be taken offline and you can either:
Reinsert the same disk Insert new disk
Reinserting the same disk should trigger rebuilding status, since data on the disk would be recognized.
If you insert a new disk, clicking add disk will give you the option to select that disk and add it to the array.
Disabled Status
A disabled status array means that your RAID level does not have enough disks to function.
Your data will be inaccessible. Rebuilding will not trigger, since RAID does not have enough parity data to rebuild
upon.
Your options in Maintenance are:
Delete – will delete the array Unplug – will take array offline, making it safe to remove Recover – will attempt to recover the array using the list from the recover tab
76
Page 77
Physical Device Information
Location – which controller and port the drive is located in Model – model number of the drive connected Capacity – total capacity of the drive Max Free – total capacity that is not configured
Rescan
Clicking rescan will force drivers to report array status. For any disk(s) you hot plug into the device, do not click rescan until all physical drives are detected and appear under Logical Device Information.
Beeper Mute
The controller emits a beeping sound whenever an
Array falls into critical status Array falls into disabled status You unplug a disk Your disk fails due to bad sectors SMART sensors anticipate drive failure
77
Page 78
If device is currently beeping, clicking Beeper Mute will mute the sound immediately.
Enable auto rebuild (default: Enabled)
When a physical drive fails, the controller will take the drive offline. Once you re­insert or replace the disk, the controller will not automatically rebuild the array unless this option is enabled.
Enable continue rebuilding on error (default: Enabled)
When enabled, the rebuilding process will ignore bad disk sectors and continue rebuilding until completion. When rebuild is finished, the data may be accessible but data inconsistency due to ignored bad sectors may cause problems in the future. If this option is enabled, HighPoint recommends user to check the event log for bad sectors.
Note: This button does not permanently mute the alarm. To permanently mute the alarm go to Setting>Enable audible alarm>Disabled.

Appendix B-4: Setting Tab

System Settings
78
Page 79
Enable audible alarm (default: Enabled)
When a physical disk fails, the controller will emit an audible sound signaling failure. This option mutes the alarm.
Set Spindown Idle Disk (minutes) (default: Disabled)
When set, physical drives will spindown a certain amount of time after disk activity ceases. Only 10, 20, 30, 60, 120, 180, 240 minutes setting are available.
Restrict to localhost access (default: Enabled)
Remote access to the controller will be restricted when enabled, other users in your network will be unable to remotely log in to the WebGUI.
Rebuild Priority (default: Medium)
You can specify the amount of system resources you want to dedicate to rebuilding the array. There are 5 levels of priority [Lowest, Low, Medium, High, Highest]
Port Number (default: 7402)
The default port that the HighPoint WebGUI listens on is 7402. You may change it to any open port.
Password Setting
Changing your WebGUI password
Under Password Setting type your new password and confirm it, then click submit.
Email Setting
You can set the controller to send an email out to recipients of your choosing when certain events (refer to Event Tab) trigger.
79
Page 80

Appendix B-5: Recover Tab

Previously created arrays will be stored under this tab. Recovering an array from here will attempt to recover a ‘disabled’ array and make it ‘normal’.
The Recover List will list all your previous and current created arrays. Each entry will list the following properties:
Array name RAID level Array Capacity Time created ( YYYY/MM/DD, HH/MM/SS, 24 hr clock format) Location of physical drives Model of physical drives
Important: When recovering an array it is important to note the location and model of each physical drive because you can only recover using those exact positions and drive model.
How to Backup your Recover List
The recover list is a record of your previously created arrays containing the model and location information of your physical drives. Recovering from the list could help bring a disabled array back to normal status for emergency data retrieval.
To backup your recover list:
1. Log in to WebGUI
2. Click Recover Tab
3. Click Backup to File
Note: The file will be saved as hptrec.rec
80
Page 81
How to Reload your Backup Recover List
Icon
Name
Definition
Information
Includes general administrative tasks:
Create/delete arrays Configuring spares Rebuilding arrays Configuring event
notifications
Configuring
maintenance
Warning
Alerts issued by the Host Adapter:
High temperatures Sector errors Communication
In the case that you cleared the recover list or it does not appear for any reason, you can recover it if you saved the list beforehand.
To reload your recover list
1. Log in to WebGUI
2. Click Recover Tab
3. Under Update Recover List click Browse.
4. Locate your previously saved hptrec.rec file and select it
Note: loading a back up recover list will completely replace the current recover list.
5. Click Submit

Appendix B-6: Event Tab

In the event tab, you can see log entries associated with the HighPoint device. The event log provides useful information when troubleshooting your set up.
In the event tab, there are four options available:
Download – Save the log file on your computer Clear – Clears all log entries
Prev – View previous log page Next – View next log page
Table 3. Event Log Icon Guide
81
Page 82
errors
Verification errors
Error
Hardware related problems
Hard disk failure Broken errors Memory failure
The event view is a basic error logging tool built into the HighPointWebGUI.

Appendix B-7: SHI (Storage Health Inspector)

S.M.A.R.T Attributes HDD Temperature Threshold Storage Health Inspector Scheduling
The SHI outputs information collected using SMART (Self-Monitoring Analysis and Reporting Technology) Hard Drive Technology. The data provided on this tab helps you to anticipate any disk failures based on a variety of monitored hard disk properties.
82
Page 83

Appendix C:WebGUI Icon Guide

Critical – missing disk
A disk is missing from the array bringing it to ‘critical’ status. The array is
still accessible but another disk failure could result in data loss.
Verifying
The array is currently running a disk integrity check.
Rebuilding
The array is currently rebuilding meaning you replaced a failed disk or added a new disk to a ‘critical’ state array.
Critical – rebuild required
The array has all disks, but one disk requires rebuilding.
Disabled
The icon represents a disabled array, meaning more than one disk failed and the array is no longer accessible
Initializing
The array is initializing. The two types of initialization is Foreground and Background. (See Initialization)
Uninitialized
The array initialization process has been interrupted, and the process is incomplete.
Not Initialized
Disk is not initialized yet, and needs to be initialized before use
OCE/ORLM
Array is performing a OCE/ORLM operation
OCE/ORLM has stopped
The array expansion process has been stopped.
Legacy
An existing file system has been detected on the disk. These disk are classified as legacy drives.
Spare
The device is a spare drive, it will automatically replace any failed drive part of an array.
Normal
The array status is normal
83
Page 84
Initializing
The array is initializing, either foreground or background initialization
Initialization Stopped
The initialization has been stopped. Current status is uninitialized.
Critical – Inconsistency
Data in the array is inconsistent and needs to be rebuilt.
Critical – missing disk
A disk has been removed or experienced failure, and user needs to reinsert disk or add a new disk.
Rebuilding
The array is currently rebuilding.
Verifying
The array is performing a data consistency check. Array status will show ‘verifying’.
Disabled
The array does not have enough disks to maintain the RAID level. A disabled array is not accessible.
OCE/ORLM
Array is expanding its capacity or migrating to a different raid level. Status will display ‘Expanding/Migrating’
OCE/ORLM stopped
The ‘Expansion/Migrating’ process has been stopped. The status will display ‘Need Expanding/Migrating’
Critical – OCE/ORLM
A disk member is lost during the OCE/ORLM process.
Critical – OCE/ORLM - rebuild
The expanding/migrating array requires a rebuild.
84
Page 85
Appendix D: RAID Level Reference Guide1
Type
Description
Min.
disks
Usable
space
Advantage
Disadvantage
Application
JBOD
Just a bunch of
disk
1
100%
Each drive can be accessed as a single volume
No fault tolerance - failure of one drive results in complete data loss
Backup
RAID
0
Disk Striping
2
100%
Offers the highest performance
No fault tolerance – failure of one drive in the array results in complete data lose
Temporary file, performance driven application.
RAID
1
Disk Mirroring
2
50%
Provides convenient low­cost data redundancy for smaller systems and servers
Useable storage space is 50% of total available capacity. Can handle 1 disk failure.
Operating system, backup, and transaction database.
RAID
10
Disk Mirroring
followed by
stripe
4
50%
High read performance and medium write performance with data protection for up to 2­drive failures
Useable storage capacity equals total capacity of all drives in the array minus two
Fast database and application servers which need performance and data protection
RAID
5
Disk Striping
with Rotating
parity
3
67-94%
High read performance, and medium write performance with data protection with a single drive failure
Not recommended for database applications that require frequent/heavy write sessions. Can handle 1 disk failure.
Data archives, and ideal for application that require data protection
RAID
6
Disk Striping
with dual
rotating parity
4
50-88%
High read performance, and medium write performance with data protection in case of up to two drives failure
Not recommended for applications that require frequent/heavy write sessions.
Data archives and ideal for application that requires data protection
1
Refer to the RAID controller product specifications for supported RAID levels.
85
Page 86

Help

Online Help redirects you to additional documentation concerning the HighPoint
WebGUI. Register Product takes you to HighPoint’s web support. On this page you can create a new customer profile where you can register your product or post an online support ticket.

HighPoint List of Recommended Hard Drives

HighPoint maintains a list of tested hard drives suitable for RAID applications. Since not every hard drive in the market can be tested, this list is meant to be a general guideline for selecting hard drives operating in a RAID environment. Regular, desktop grade drives are highly not recommended for RAID use.
http://highpoint­tech.com/PDF/Compatibility_List/RocketRAID_600_2700_3600_and_4500_Series_RAID _HBA_Hard_Drive_Compatiblity_List.pdf

Contacting Technical Support

Frequent asked questions can be found on the online knowledge base:
http://www.highpoint-tech.com/websupport/kbn.php
For any help and support, submit a support ticket online at http://www.highpoint-
tech.com/websupport/ .
You may also call us during our regular business hours: Monday – Friday (Excluding Holidays), 9 AM to 6 PM (PST) Phone: (408) 240-6108
86