HighPoint 4460 User Manual

0 (0)

RocketRAID 4460

PCI-Express 2.0 SAS/SATA

Hardware RAID Controller

User’s Guide

Revision: 1.0

Date: July 2009

HighPoint Technologies, Inc.

1

Copyright

Copyright © 2009 HighPoint Technologies, Inc. This document contains materials protected by International Copyright Laws. All rights reserved. No part of this manual may be reproduced, transmitted or transcribed in any form and for any purpose without the express written permission of HighPoint Technologies, Inc.

Trademarks

Companies and products mentioned in this manual are for identification purpose only. Product names or brand names appearing in this manual may or may not be registered trademarks or copyrights of their respective owners. Backup your important data before using HighPoint’s products and use at your own risk. In no event shall HighPoint be liable for any loss of profits, or for direct, indirect, special, incidental or consequential damages arising from any defect or error in HighPoint’s products or manuals. Information in this manual is subject to change without notice and does not represent a commitment on the part of HighPoint.

Notice

Reasonable effort has been made to ensure that the information in this manual is accurate. HighPoint assumes no liability for technical inaccuracies, typographical, or other errors contained herein.

2

Table of Contents

Table of Contents

AboutThisGuide..................................................................................................

6

Congratulations

 

Specifications and Features.....................................................................................................

8

HARDWARE -- DESCRIPTION AND INSTALLA-

TION

1 - RocketRAID Adapter layout ..................................................................................

11

2 - Installing the RocketRAID HostAdapter......................................................................

13

3

-VerifyingInstallation..........................................................................................................

14

4

-BatteryBackup....................................................................................................................

15

ROCKETRAID BIOS UTILITY

 

1 - BIOS Setting Overview ..........................................................................................

16

2

-CreatingRAIDArrays........................................................................................................

20

3

-DeletingArrays...................................................................................................................

25

4 - Monitoring the Host Adapter, Arrays and Devices ...............................................

26

5

- MaintainingArrays............................................................................................................

29

6 - Additional Functions and Settings..................................................................................

35

3

Table of Contents

 

HIGHPOINT RAID MANAGEMENTAND DE-

 

VICE DRIVER CD

 

1 - Creating a Driver Diskette.................................................................................................

38

2 - Device Driver Installation.................................................................................................

39

3 - HighPoint RAID Management Utilities (HRM).............................................................

45

CUSTOMER SUPPORT

 

Troubleshooting Checklist ...................................................................................................

56

CONTACTUS......................................................................................................

57

4

Congratulations

HighPoint Technologies, Inc.

HighPoint Technologies, long recognized as a leader in mass storage technologies specializes in the design and manufacturer of HBA (Host Bus Adapters) and HighPoint RAID IP (Intellectual Property). HighPoint provides a broad range of scalable hardware HBA’s that meet the storage requirements from Enterprise to SMB (Small Medium Sized Business) to PC enthusiast.

The HighPoint RAID IP includes TerabyteArchitecture™ for (Performance, Protection and Prevention).

TerabyteStream™ - leverages the built-in Intel Xscale XOR Engine to deliver unprecedented RAID 5 and 6 performances.

TerabyteGuard™ - prevents data lose and increases data reliability with advanced hard drive inspection features utilizing bad sector repair and remapping.

TerabyteSaver™ - optimizes data protection with a battery backup and with write journaling thus preventing data loss.

5

Congratulations

About This Guide

The RocketRAID 4460 SAS Host Adapter’s User’s Guide provides information about the functions and capabilities of the host adapter, and instructions for installing, configuring and maintaining RAID arrays hosted by the adapter.

The RocketRAID 4460 Host Adapter

The HighPoint RocketRAID 4460 is the world’s fastest hybrid RAID controller utilizing Intel IOP348 processor.The RocketRAID 4460 is the latest product in storage technology, leveraging the storage performance in SAS and supporting the fastest available throughput while supporting enterprise level features such as Native Command Queuing (NCQ),staggered drive spin-up and SAF-TE (I2C) enclosure management support.

PCI-Express 2.0

HighPoint RocketRAID 4460 PCI Express 2.0 SAS/SATA RAID solution double the bandwidth of the existing PCI Express bus enabling the fastest throughput and enhances system performance. PCI-Express 2.0 provides 4GB/s of throughput which doubles that of PCI-Express 1.0 at 2GB/s.

Intel 81348 I/O Processor and SDRAM

The RocketRAID 4460 RAID Controller has an integrated hardware I/O processor for RAID 6 parity calculations. With the new I/O processor the system CPU is free to perform other important tasks. There is also 1GB DDR2 533 that allows for upgrading up to 4GB of memory,with DIMM socket, support ECC protection on the RocketRAID 4460 RAID Controller for improved performance.

Comprehensive OS Support

HighPoint offers the broadest range of support for all major operating systems to ensure OS and hardware server compatibility. Drivers are available for all major operating systems, including Windows , Linux, Mac OS X and FreeBSD. GPL Licensed Linux drivers into main Linux kernel help customers easily install and configure the RocketRAID 4460.

6

Congratulations

HighPointRAIDManagement

HighPoint RAID Management software offers a user friendly interface to create, manage and maintain your storage solutions. Email notification and remote are some of the advance features that the RAID Management software has to offer.

Onboard Cache and Optional Battery Backup for optimal performance and added

security

1GB DDR2 533,with DIMM socket, support ECC protection on board of the RocketRAID 4460 for improved performance, and provides additional security in the case of critical system failure, when used in conjunction with the optional battery back up unit.

7

Congratulations

Congratulations

You have purchased one of the highest performing and SAS/SATA hardware RAID controllers available. The RocketRAID 4460 offers the performance and data protection features for homogeneous storage environments. The RocketRAID 4460 meets the bandwidth requirements for high performance applications like video capture and editing, CAD/CAM and digital graphics.

Remember to visit the HighPoint websites at http://www.highpoint-tech.com and http://www.hptmac.com. There you can find information on all of HighPoint’s products with FAQ’s, online manuals, BIOS and driver updates.

1 - Specifications and Features

Host Adapter Architecture

TerabyteStream™ for Blazing Performance

IntelIOP81348(1.2GHz)

PCI -Express gen2 x8

One DIMM Socket with default 1GB of DDR2-533 SDRAM with ECC protection, upgrade to 4GB

Out of Band Management (Independent RAID Module

10M/100M Ethernet Port for out band management

Automatic detect 24 internal ports or 20 internal & 4 external ports

Multi adapter support up to 4 adapters

Support Security MCU

NVRAM for write journaling

Battery Backup Unit (BBU) Optional

RoHS compliant

Advance RAID Features

Support RAID 0, 1, 3, 5, 6,10, 50 and JBOD

Multiple RAID support

Multiple Logical Drive Support

BIOS booting support

8

Congratulations

BIOS Booting (INT13) to RAID array for better redunancy

Write through and write back cache

Online array roaming

Online capacity expansion (OCE) and Online RAID level migration (ORLM)

Quick and Background initialization for instant RAID configuration

Automatic drive insertion / removal detection and rebuild

64bit LBA support greater than 2TB per volume

S.M.A.R.T monitoring hard drive status for reliability

Staggered Spinup with user selection in BIOS

Array Monitors, Alerts and Indicators

SMTP for email notification

Hardware Monitor function

Alarm / Buzzer alerts for drive failure

SAF-TE (I2C) and SGPIO enclosure management SES-2 enclosure management

SNMP for remote management

NTP (Network Time Protocol)

Hardware Monitor to monitor the voltage, temperature and fan speed

RAID Management

Online capacity expansion (OCE) and Online RAID level migration (ORLM)

Online array roaming

Multiple Logical Drive Support

Quick and Background initialization for instant RAID access

API library for customizing AP

Command Line Interface (CLI)

Web browser-base RAID management software

Disk scrubbing to prevent degraded RAID arrays

SHI – Storage Health Inspector (S.M.A.R.T. and disk maintenance)

Operating System Support

Windows (2000, XP, 2003,2008,Vista and Windows 7 capable)

Linux

VMWare ESX Server

FreeBSD

Mac OS X

9

Congratulations

PHYSICAL SPECIFICATIONS

Size:(265mmx111 mm)10.44”Lx4.38”W

WEMI : FCC Part 15 Class B and CE

Thermal and Atmospheric Characteristics:

Work Temperature Range : +5 C ~ + 55 C

Relative Humidity Range : 5% ~ 60% non condensing

Storage Temperature : -20 C~ +80 C

MTBF: 920,585 Hours

Electrical Characteristics:

PCI-E

3.3V

12V

 

 

 

Power

6W max

40W max

 

 

 

10

Hardware – Description and Installation

Hardware - Description and Installation

1-RocketRAID Adapter layout

Port1 to Port6

These represent RocketRAID 4460’s 6 Internal Mini-SAS ports. Each port can direct connect up to 4 hard drives.

Port7

This represents RocketRAID 4460’s additional External Mini-SAS port. With the automatic port selection funtion, Port7 can be used when Port1 has no disks attached during power up,this port can direct connect up to 4 hard drives.

Note : Only Port1(/Port7) and Port2 support SAS expander.

U12

The connector represents one DDR2-533 DIMM socket that allows for upgrading up to 4GB of memory. By default,it supports 1GB of ECC DDR533 SDRAM memory.

A1-A6, F1-F6

A1-A6 are Disk Activity LED’s; F1-F6 are Disk Faliture LED’s.

11

Hardware – Description and Installation

J1

This jumper supports SAF-TE interface(I2C).

J2

LCD connector for LCD Panel and Push Button

J3 (BBU connector)

Connector for battery backup unit (optional part).

12

Hardware – Description and Installation

BEEP1 – Speaker

Alarm (speaker): the speaker emits and audible alarm in the case of disk/array failure.

Ethernet Port

Ethernet port(J4) for Out of Bound Manegement, support Net Time Protocol.

Cable – Internal Mini-SAS to Mini-SAS

The integrated RocketRAID 4460 includes 6 Internal Mini-SAS to Mini-SAS cables.

2 - Installing the RocketRAID 4460 Host Adapter

Note: Make sure the system is powered-off before installing the RocketRAID 4460 host adapter.Be sure of the cache memory module is present and seated firmly in the DIMM socket (DDR2-533) for RocketRAID 4460.

1.

Check/Upgrade Memory Module before installing the RocketRAID 4460 Host

 

Adapter.The RocketRAID 4460 controller include one DIMM socket with

 

default 1GB of ECC DDR2533 SDRAM. User can upgrade to 2GB or 4GB

 

DDR2 module.

 

 

 

 

 

 

Below table show the specification of supported DDR2 module.

 

 

 

 

 

 

 

 

 

 

 

Density

SPEED

DDR DIMM module Type

Chip data width

 

Number of RANK

 

 

 

 

 

 

 

 

 

 

1GB, 2GB, 4GB

533Mhz capable

DDR2, 240Pin, ECC, Unbuffered or Registered

X8 or X16

 

1 or 2

 

 

 

 

 

 

 

 

 

2.

Open the system chassis and locate an unused PCI-E x8.

 

 

3.

Remove the PCI slot cover.

 

 

 

 

4.

Gently insert the RocketRAID 4460 into the PCI-E slot, and secure the bracket to

 

the system chassis.

 

 

 

 

 

5.

After installing the adapter, attach the Mini-SAS connectors to the RocketRAID

 

4460’s Mini-SAS port,and to chassis backplane. Each Mini-SAS cable supports

 

up to 4 hard disk drives. Consult the chassis’s manual for proper installation

 

procedures.

 

 

 

 

 

 

 

 

 

 

 

13

 

Hardware – Description and Installation

6.Close and secure the system chassis.

3 - Verifying Installation

Once the RocketRAID 4460 host adapter and hard disks have been installed into the chassis, boot-up the system to verify that the hardware is properly recognized.

1.Power on the system. If the system detects the presence of the adapter, the RocketRAID 4460 BIOS Utility will be displayed during bootup.

2.Press Ctrl+H to access the RocketRAID 4460 BIOS Utility.

The BIOS Utility will display information about hard disks attached to the adapter. Make sure all attached disks are detected by this utility. If any of the hard disks are not detected, power down the system and check the cable connections to both the card, and enclosure.

14

Hardware – Description and Installation

4 - Battery Backup

A battery backup option will be available as an optional add-on component. The battery provides additional data security in case of a critical system failure.

Data normally lost during a major system fault, such as a power outage or CPU failure, which was in transit at the time of the failure (stored in the card’s onboard cache), will remain viable for up to 72 hours.

The battery unit can be attached to the card using the BBU CONN.

Attach the BBU into J3 of RocketRAID 4460 using the cable included with the BBU unit:

15

RocketRAID BIOS Utility

RocketRAID BIOS Utility

The RocketRAID 4460 card will display it’s BIOS screen during the system’s boot process.

Press Control + H when prompted, to access the BIOS settings Menu.

1 - BIOS Settings Overview

The RocketRAID 4460 BIOS utility is an interface that provides management commands and controller related settings.

Using the BIOS Utility

The following keys utilized by the RocketRAID 4460 BIOS utility:

F10 – press F10 to highlight the tool bar Menu.

Arrow keys – use these to move between different menu items

Enter – Open the selected toolbar command/execute the selected command.

Esc – move back to the previous menu, cancel the selected operation.

Tab – Switch between Disk and Array menus, move to next Menu item.

Space Bar – select an item (when selecting Block Size for a RAID configuration, for

example).

16

RocketRAID BIOS Utility

BIOS Menu Shortcuts

The BIOS interface can also be navigated using key stroke combinations (Alt +” X”). When viewing the interface, letters highlighted in “red” represent the “X” values: “S” – System

“D” – Disk

“A” – Array

“C” – Controller

“W” – Window

“H” – Help

“X” - Exit

Logging In

The BIOS Utility has two interface modes: User and Supervisor

The User mode can only view information about the RocketRAID card, disks and arrays.

The Supervisor mode is used to create/delete arrays, and configure RocketRAID related settings. Supervisor mode requires a password – this is the same password that you will need in order to use the Web Management interface.

Press F10 – this should bring you to the “System” toolbar command. Press Enter.

To log on as a User, use the arrow keys to highlight “User mode”, and press Enter. To log on as Supervisor, select “Supervisor Mode”:, and press Enter.

17

HighPoint 4460 User Manual

RocketRAID BIOS Utility

You will be asked to enter the Supervisor password.

The default password is “hpt”.

BIOS Commands

System

User/Supervisor modes – interface modes

Change password - for Supervisor mode

Exit the utility – quit and exit the RocketRAID BIOS utility

Disk

Information – displays information about the select hard disks

Initialize – initialize the selected disks (required in order to use new hard disks for creating RAID arrays, disk replacement, or configuring spare disks.

Toggle Spare – configure spare disks.

Unplug – remove the selected disks (hot-swap)

Turn on write cache – enable write cache for the selected disks

Turn off write cache – disable write cache for the selected disks

Rescan – prompts the RocketRAID card to scan for new hard disks.