HighPoint 4310 User Manual

Page 1
RocketRAID 43xx
SAS/SATAII Host Adapter
User’s Guide
Revision: 1.0 Date: February 2009 HighPoint T echnologies, Inc.
1
Page 2
Copyright
T rademarks
Companies and products mentioned in this manual are for identification purpose only. Product names or brand names appearing in this manual may or may not be registered trademarks or copyrights of their respective owners. Backup your important data before using HighPoint’s products and use at your own risk. In no event shall HighPoint be liable for any loss of profits, or for direct, indirect, special, incidental or consequential damages arising from any defect or error in HighPoint’s products or manuals. Information in this manual is subject to change without notice and does not represent a commitment on the part of HighPoint.
Notice
Reasonable effort has been made to ensure that the information in this manual is accurate. HighPoint assumes no liability for technical inaccuracies, typographical, or other errors contained herein.
2
Page 3
Table of Contents
Table of Contents
HIGHPOINT TECHNOLOGIES, INC.....................................5
CONGRATULATIONS
1 - Specifications and Features .....................................................................................6
2 - Kit Contents .............................................................................................................8
HARDWARE -- DESCRIPTION AND INST ALLA­TION
1 - RocketRAID Adapter layout....................................................................................9
2 - Installing the RocketRAID Host Adapter..............................................................15
3 - Verifying Installation ..............................................................................................17
4 - Battery Backup....................................................................................................... 17
ROCKETRAID BIOS UTILITY
1 - BIOS Setting Overview .......................................................................................... 18
2 - Creating RAID Arrays............................................................................................ 22
3 - Deleting Arrays ......................................................................................................27
4 - Monitoring the Host Adapter, Arrays and Devices ...............................................28
5 - Maintaining Arrays ................................................................................................31
6 - Additional Functions and Settings ........................................................................ 36
3
Page 4
Table of Contents
HIGHPOINT RAID MANAGEMENT AND DE­VICE DRIVER CD
1 - Creating a Driver Diskette ......................................................................................39
2 - Device Driver Installation ......................................................................................40
3 - HighPoint RAID Management Utilities (HRM) ......................................................46
CUSTOMER SUPPOR T
Troubleshooting Checklist .........................................................................................57
CONTACT US ......................................................................................................58
4
Page 5
Table of Contents
HighPoint T echnologies, Inc.
HighPoint Technologies, long recognized as a leader in mass storage technologies specializes in the design and manufacturer of HBA (Host Bus Adapters) and HighPoint RAID IP (Intellectual Property). HighPoint provides a broad range of scalable hardware HBA’ s that meet the storage requirements from Enterprise to SMB (Small Medium Sized Business) to PC enthusiast.
The HighPoint RAID IP includes TerabyteArchitecture™ for (Performance, Protec- tion and Prevention).
TerabyteStream™ - leverages the built-in Intel Xscale XOR Engine to deliver unprec­edented RAID 5 and 6 performances.
TerabyteGuard™ - prevents data lose and increases data reliability with advanced hard drive inspection features utilizing bad sector repair and remapping.
TerabyteSaver™ - optimizes data protection with a battery backup and with write journaling thus preventing data loss.
5
Page 6
Congratulations
Congratulations
You have purchased one of the highest performing and SAS/SATA hardware RAID
controllers available. The RocketRAID 4300 series offers the performance and data
protection features for homogeneous storage environments. The RocketRAID 4300
series meets the bandwidth requirements for high performance applications like video
capture and editing, CAD/CAM and digital graphics.
Remember to visit the HighPoint websites at
http://www.hptmac.com. There you can find information on all of HighPoint’s prod-
ucts with FAQ’s, online manuals, BIOS and driver updates.
http://www.highpoint-tech.com and
1 - Specifications and Features
Host Adapter Architecture
TerabyteStream™ for Blazing Performance
TerabyteSaver™ and TerabyteGuard™ for Data Protection and Reliability
Intel IOP 81348 (1.2GHz)
Intel IOP 81348 (800MHz)(RocketRAID RR4310/4311)
PCI -Express x8 (compatible with x16 slot)
256 MB(RocketRAID 4320/4310/4311) / 512MB(RocketRAID 4322/4321) of
DDR II memory with ECC protection
RocketRAID 431x directly support up to 4 SAS/SATAII drives
RocketRAID 432x directly support up to 8 SAS/SATAII drives
Multi adapter support up to 4 adapters
Intel RAID 6 (P+Q) for large capacity RAID arrays
NVRAM for write journaling
Battery Backup Unit (BBU) Optional
RoHS compliant
6
Page 7
Congratulations
Advanced RAID Features
Supports RAID 0,1,3,5,6,10,50 and JBOD
Multiple RAID array support
Multiple logical drive support
BIOS booting support
BIOS PnP and BBS (BIOS boot specification)support
Write through and write back cache
Online Array roaming
Online capacity expansion (OCE) and Online RAID level migration (ORLM)
Quick and Background initialization for instant RAID configuration
Automatic RAID rebuild
64bit LBA support greater than 2TB per volume
S.M.A.R.T monitoring hard drive status for reliability
Staggered Drive Spinup
(MAID) spin down drives in array when idle
ATA pass-through mode support
Firmware update while running the Operating System
Array Monitors, Alerts and Indicators
SMTP for email notification
Hardware Monitor function(RocketRAID 432x)
Alarm / Buzzer alerts for drive failure
SAF-TE (I2C) and SGPIO enclosure management (RocketRAID432x/4310)
SAF-TE(I2C) enclosure management (RocketRAID 4311)
SNMP for remote management(RocketRAID 432x)
Ethernet port for (OBM) Out of Band Management (RocketRAID 432x)
NTP (Network Time Protocol)(RocketRAID 432x)
Intelli-VRM. (Intelligent V irtual RAID Management)
SHI – Storage Health Inspector (S.M.A.R.T. and disk maintenance)
HighPoint RAID Management (HRM)
Hot key (ctrl-h) boot-up RAID manager via BIOS
Web browser-base RAID management software
Command Line Interface (CLI)
API library for customizing AP
7
Page 8
Congratulations
Operating System Support
Windows XP, 2003, Vista, 2008 (32 and 64-bit versions)
Linux (Fedora Core, Red Hat Enterprise / CentOS, SuSE, Debian, Ubuntu)
Mac OS X 10.4.x and above FreeBSD
Freebsd
GPL licensed driver into Linux Kernel 2.6.25
Physical Specifications
Size: (163.0mm x 68.0mm) 6.42”L x 2.68” W (RocektRAID 4322) Size: (167.0mm x 68.0mm) 6.57”L x 2.68” W WEMI : FCC Part 15 Class B and CE
Thermal and Atmospheric Characteristics:
W ork Temperature Range: +5 C ~+ 55 C Relative Humidity Range: 5% ~ 60% non condensing Storage T emperature: -20C ~ +80 C MTBF: 920,585 Hours
Electrical Characteristics:
2 - Kit Contents
RocketRAID Host Adapter
User’s Guide
HighPoint RAID Management and Device Driver CD
Internal Mini-SAS to Mini-SAS cables (RocektRAID 4310/4320/4321)
8
Page 9
Hardware – Description and Installation
Hardware - Description and Installation
1-RocketRAIDAdapter layout
1.1 – RocketRAID 431x/4321 Adapter layout
(illustration shows the RocketRAID 4321)
Port1- This is provided for theRocketRAID 4310/4321. This represent the RocketRAID 4310/4321’ s a Internal Mini-SAS port. Port2 -This is provided for theRocketRAID 4311/4321. This represent the RocketRAID 4311/4321’ s a External Mini-SAS port. Each port can directly support up to 4 SAS/SATA hard disks.
A1,F1
A1 is Disk Activity LED’s; F1 is Disk Failure LED’ s.These connectors are provided for RocketRAID 4310/4321’s Internal Mini-SAS port.
9
Page 10
Hardware – Description and Installation
Pin - SAS/SATA channel/port stable:
J1
This connector supports SAF-TE interface (I2C).
J2
LCD connector for LCD Panel and Push Button Pins defined as follow:
10
Page 11
Hardware – Description and Installation
J3 (BBU connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
J4 - Ethernet Port (RocketRAID 4321)
Ethernet port for Out of Bound Management, support Net Time Protocol.
Cable – Internal Mini-SAS to Mini-SAS
The RocketRAID 4310/4321 includes 1 Internal Mini-SAS to Mini-SAS cables.
11
Page 12
1.2 – RocketRAID 4320 Adapter layout
Port1- Port2 - These represent the RocketRAID 4320’ s 2 Internal Mini-SAS ports.
Each port can directly support up to 4 SAS/SATA hard disks.
J9,J10,J11,J12
J9,J10 are Disk Activity LED’ s; J1 1,J12 are Disk Failure LED’ s.
Pin - SAS/SATA channel/port stable:
12
Page 13
Hardware – Description and Installation
J16
This connector supports SAF-TE interface (I2C).
Pin definitions: Pin 1: SCL; Pin 2: GND; Pin 3: SDA.
J14 (BBU connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
Ethernet Port
Ethernet port for Out of Bound Management, support Net Time Protocol.
Cable – Internal Mini-SAS to Mini-SAS
The RocketRAID 4320 includes 2 Internal Mini-SAS to Mini-SAS cables.
13
Page 14
Hardware – Description and Installation
1.3 – RocketRAID 4322 Adapter layout
Port1, Port2
These represent the RocketRAID ’s 2 External Mini-SAS ports. Each port can directly support up to 4 SAS/SATA hard drives.
J3 (Battery connector)
Connector for HPTBBU-03 (HighPoint Battery Backup Unit 03,optional part,sold separately—see “Battery Backup” for details).
BEEP1 – Speaker
Alarm (speaker): the speaker emits an audible alarm in the case of disk/array failure.
J4 (HighPoint Ethernet Board connector)
Connector for HighPoint Ethernet Board ( see “Installing the HighPoint Ethernet Board” for details)
14
Page 15
Hardware – Description and Installation
2 – Installing the RocketRAID Host Adapter
2.1 – Installing the RocketRAID 431x/4320/4321 Host Adapter
Note: Make sure the system is powered-off before installing the RocketRAID 431x/ 4320 /4321host adapter.
1. Open the system chassis and locate an unused PCI-E x8 or x16 slot.
2. Remove the PCI slot cover.
3. Gently insert the RocketRAID 431x/4320/4321 into the PCI-E slot, and secure the bracket to the system chassis.
4. After installing the adapter, attach the Mini-SAS cables to the RocketRAID 4310/ 4320/4321’s Mini-SAS port, and the chassis backplane. Each Mini-SAS cable supports up to 4 hard disk drives. Consult the chassis’s manual for proper installation procedures.
(illustration shows the RocketRAID 4320)
5. Close and secure the system chassis.
15
Page 16
Hardware – Description and Installation
2.2 – Installing the RocketRAID 4322 Host Adapter
Note: Make sure the system is powered-off before installing the RocketRAID 4322 host adapter.
1. Installing the HighPoint Ethernet Board – the following illustration shows the
HighPoint Ethernet Board.
U1 is the RJ45 connector. J1 is connector for connecting the HighPoint Ethernet Board to the RocketRAID Host Adapter. If you want to use the Ethernet functions, connect the HighPoint Ethernet Board to the RocketRAID Host Adapter via connec­tors J4 through J1, and secure the two boards to the bracket. If you do not want to use the Ethernet function, secure the RocketRAID Host Adapter to the bracket.
1. Open the system chassis and locate an unused PCI-Express x8.
2. Remove the PCI slot cover.
3. Gently insert the RocketRAID 4322 into the PCI-Express slot, and secure the bracket to the system chassis.
4. Close and secure the system chassis
16
Page 17
Hardware – Description and Installation
3 - Verifying Installation
Once the RocketRAID host adapter and hard drives have been installed into the
.
chassis, boot-up the system to verify that the hardware is properly recognized.
1. Power on the system. If the system detects the presence of the adapter, the
RocketRAID BIOS Utility will be displayed during bootup.
2. Press Ctrl+H to access the RocketRAID adapter’s BIOS Utility. The BIOS Utility will display information about hard disks attached to the adapter.
Make sure all attached disks are detected by this utility. If any of the hard disks are not detected, power down the system and check the power and cable connections
4 - Battery Backup
A battery backup option is available as an optional add-on component. The battery provides additional data security in case of a critical system failure. Data normally lost during a major system fault, such as a power outage or CPU failure, which was in transit at the time of the failure (stored in the card’s onboard cache), will remain viable for up to 72 hours. The battery unit can be attached to the card using the BBU CONN. Attach the BBU to the RocketRAID 431x/432x, using the cable included with the BBU unit:
(illustration shows the RocketRAID 4322)
17
Page 18
RocketRAID BIOS Utility
RocketRAID BIOS Utility
The RocketRAID 431x/432x card will display it’s BIOS screen during the system’s boot process. Press Control + H when prompted, to access the BIOS settings Menu.
Now, RocketRAID 432x will be used for illustrating ,you will know how to do BIOS Utility of RocketRAID controllers .RocketRAID 431x are similar to RocketRAID 432x, except for channel number ,Ethernet port and Hardware Monitor function.
1 - BIOS Settings Overview
The RocketRAID 432x BIOS utility is an interface that provides management com­mands and controller related settings.
Using the BIOS Utility
The following keys utilized by the RocketRAID 432x BIOS utility:
F10 – press F10 to highlight the tool bar Menu. Arrow keys – use these to move between different menu items Enter – Open the selected toolbar command/execute the selected command. Esc – move back to the previous menu, cancel the selected operation. Tab – Switch between Disk and Array menus, move to next Menu item. Space Bar – select an item (when selecting Block Size for a RAID configuration, for
example).
18
Page 19
RocketRAID BIOS Utility
BIOS Menu Shortcuts
The BIOS interface can also be navigated using key stroke combinations (Alt +” X”). When viewing the interface, letters highlighted in “red” represent the “X” values: “S” – System “D” – Disk “A” – Array “C” – Controller “W” – Window “H” – Help “X” - Exit
Logging In
The BIOS Utility has two interface modes: User and Supervisor The User mode can only view information about the RocketRAID card, disks and
arrays. The Supervisor mode is used to create/delete arrays, and configure RocketRAID related settings. Supervisor mode requires a password – this is the same password that you will need in order to use the Web Management interface. Press F10 – this should bring you to the “System” toolbar command. Press Enter.
T o log on as a User, use the arrow keys to highlight “User mode”, and press Enter. T o log on as Supervisor, select “Supervisor Mode”:, and press Enter .
19
Page 20
RocketRAID BIOS Utility
You will be asked to enter the Supervisor password. The default password is “hpt”.
BIOS Commands
System
User/Supervisor modes – interface modes Change password - for Supervisor mode Exit the utility – quit and exit the RocketRAID BIOS utility
Disk
Information – displays information about the select hard disks Initialize – initialize the selected disks (required in order to use new hard disks for
creating RAID arrays, disk replacement, or configuring spare disks.
Toggle Spare – configure spare disks. Unplug – remove the selected disks (hot-swap) Turn on write cache – enable write cache for the selected disks T urn off write cache – disable write cache for the selected disks Rescan – prompts the RocketRAID card to scan for new hard disks.
20
Page 21
RocketRAID BIOS Utility
Array
Information – displays information about the selected RAID array Create – Create a RAID array using the selected disks Delete – Delete the selected RAID array Unplug – Remove the selected RAID array (safe removal of disk members of the target
array - hot-swap)
Verify – Verify the selected array (checks for parity errors) Start T ask – End Task – Stop/Pause current task
Controller
Information – V iew information about the RocketRAID host adapter Eventlog – View event log entries Setting – View and configure host adapter settings Network – V iew and configure host adapter network configuration
Window
Maximize – enlarge the selected Window Restore – restore Windows sizes to default setting
1.Disk – toggle/select the Disk Window
2.Array – toggle/select the Array Window Refresh – updates on screen information
Help
About – BIOS utility/Company information
21
Page 22
RocketRAID BIOS Utility
2 - Creating RAID Arrays
Initializing Disks:
Before creating a RAID array, the disks must be initialized. Disk initialization writes necessary RAID configuration information to the hard disks.
1. From the Disk window, highlight the target disks using the arrow keys, then select using Enter. A numeral will be displayed before each selected disk.
2 . Once all target disks have been selected, select Disk from the tool bar, then
highlight Initialize and press Enter.
3. The utility will display a warning, and ask you to press Y (yes) to initialize, or N (no) to cancel. Once initialized, these disks can be used to create RAID arrays.
Warning: Initialization will destroy all pre- existing data on the selected hard disks. Only initialize disks that do not contain critical data. Disks only need to be initialized once.
Warning: Initialization will destroy all pre- existing data on the selected hard disks. Only initialize disks that do not contain critical data. Disks only need to be initialized once.
Disks do not have to be re-initialized after an array is deleted, or before creating a new array.
22
Page 23
RocketRAID BIOS Utility
Creating Arrays:
From the Disk window, highlight the target disks using the arrow keys, then select using Enter. A numeral will be displayed before each selected disk. To de-select a disk, highlight the target disk, and press Enter once more.
Once all target disks have been selected, select Array from the tool bar, then highlight Create and press Enter.
This will open the RAID creation Menu.
23
Page 24
RocketRAID BIOS Utility
1. Array Type: First, use the Tab or arrow keys to highlight the desired RAID level, and press the Spacebar to select the Array Type. The RocketRAID 432x host adapters support RAID 0, 1, 3, 5, 6, 10, 50 and JBOD.
2. Cache Policy: Specify the Cache Policy of the array.
a. None: No cache policy set b. Write-back – utilizes disk cache. Default setting, optimal for
performance.
c. Write-through – data is written directly to disk. More secure than
Write-back, but will perform slower .
3. Init Method – For redundant arrays (RAID 0,1, 3, 5, 6, 10 and 50) specify the RAID Initialization method.
a . Quick init – use this option if you want to quickly create an array
for testing purposes. This will clear all previous data, and will not build parity. Do not use this method if data integrity is priority.
b. Foreground – this will instruct the host adapter BIOS utility to start
the initialization process immediately after creating the array. This option is recommended for data security.
c. Background – this will instruct the host adapter to initialize the
array in the background, after the operating system has booted. Consider this option if you need to install an operating system to the array – this allows the array to be used immediately.
24
Page 25
RocketRAID BIOS Utility
4. Name: Use the Tab or arrow keys and highlight Name. This feature allows you to name an array for reference. This is an optional setting. Press Enter to use the default name, or type in the desired name, and press Enter.
5. Capacity (GB): The adapter will display the full available capacity by default. If you want to specify the size of the array, type in the desired capacity (in Gigabytes), and press Enter. Specifying the capacity allows you to create multiple arrays using the same set of disks. Any free disk space can be used to create additional arrays, or used as a Spare disk (if the available capacity meets the requirement – see 5 - Maintaining Arrays – Spar e Disks, for more information).
6. Block Size – This option allows you to specify the block size (also known as “stripe size”) for specific array types (RAID 0, 1,3, 5, 6, 10 and 50). You can specify block sizes ranging from 16(KB) to 1024(KB). This allows you to tailor the array for specific applications. A balanced block size of 64 (in KB) is recom­mended for most applications.
7. Create / Cancel – Use Tab or arrow keys to highlight the Create or Cancel options, and press Enter. Selecting Cancel will stop the creation process. Selecting Create will create an array based on your selections, and open the Sector Size window.
25
Page 26
RocketRAID BIOS Utility
8. Sector Size – Also known as VSS (Variable Sector Size), this option allows you to
specify the sector size of the array, for use With Windows operating systems. Older, 32-bit versions of Windows do not support volumes over 2TB in size, unless the sector size is altered. This option is not needed for Windows XP 64, Win2003 (SP1), W indows 2008, or Windows Vista. These operating systems support larger volumes, and introduce a partitioning method known as GPT (GUID Partition table). Use GPT when creating arrays over 2TB in size. For Windows 2000, or 32-bit versions of XP, refer to the following chart:
512B – Default sector size (supports up to 2TB). Use this setting for Windows OS that support GPT.
1K – Supports arrays up to 4TB 2K – Supports arrays up to 8TB 4K – Supports arrays up to 16TB
Highlight the appropriate Sector Size, and press Enter to create the array.
26
Page 27
RocketRAID BIOS Utility
3 – Deleting Arrays
From the Array window, highlight the target array and press Enter. Highlight Array from the toolbar.
Select Delete and press Enter. The utility will display a warning message. Press Y (yes) to delete the array, or select N (no) to cancel.
Warning: all data stored on the array will be lost – do not delete if the array contains critical data.
27
Page 28
RocketRAID BIOS Utility
4 – Monitoring the Host Adapter, Arrays and Devices
The BIOS Settings Utility allows the Administrator to check the status of the RocketRAID host adapter, and any devices (hard disks), and arrays hosted by the adapter.
Disk/Array Status
To check the status of any disk or array, use Tab to select the Disk or Array Windows, highlight the target disk/array and press enter.
Array Information – this will display the array’s Name, RAID type, Block size, Sector size, member hard disks, and status.
Disk Information – this will display the disk Model Number, serial number, firmware revision, capacity , and various disk related settings (NCQ, TCQ, Read Ahead, Write Cache, and Staggered Drive spinup mode).
Alternately, highlight the target disk/array , then highlight either Disk or Array from the tool bar, select Information, and press Enter.
28
Page 29
RocketRAID BIOS Utility
Controller Information
Highlight Controller from the toolbar, select Information, and press Enter.
Array Information – this will display the array’s Name, RAID type, Block size, Sector
size, member hard disks, and status.
This option will display information about the host adapter’s model (Product ID), PCI­E bus location, IO Processor model, memory, firmware revision, serial number, and the status of the BBU (battery backup unit).
Event Log
The RocketRAID host adapter automatically generates Event Log entries during the case of routine administration (creating arrays), or in the case of a critical error (disk or array failure).
Highlight Controller from the toolbar, select Event Log, and press Enter.
29
Page 30
RocketRAID BIOS Utility
Use this option to view Event Log information, including Errors (disk or array failure), Warnings (problems such as disk sector or Smart issues) and Information (such as the creation or deletion of arrays).
You can filter displayed events by using Tab to highlight the Information, Warning, and Error options towards the top of the window. Enable or disable these filter options using the Spacebar.
Use the Clear option to delete all Event Log entries. Use the Prev and Next option to scroll through log entries. Select Cancel (or press Esc) to exit the window.
30
Page 31
RocketRAID BIOS Utility
5 – Maintaining Arrays
The BIOS Settings Utility provides several RAID and device related maintenance functions, including device and controller settings, Network Configuration settings (for managing the host adapter, remotely), and rebuilding broken/degraded RAID arrays.
Network Settings
This option allows the Administrator to configure Network Settings for use with the RocketRAID host adapter’s Out-of-Band (OOB), and In-Band (IB) Management functions.
Highlight Controller from the toolbar, select Network, and press Enter.
This option will display information about the host adapter’s network settings. By default, these settings are configured automatically, based on information provided by the local network. To manually configure these settings, use the Tab or arrow keys and highlight Use automatic config, and press the Spacebar. Type in the appropriate network settings, highlight OK, and press Enter.
31
Page 32
RocketRAID BIOS Utility
Controller Settings
Highlight Controller from the toolbar, select Settings and press Enter.
Use the tab and arrow keys to select each item, and the Spacebar to enable/disable the target option.
Enable Audible Alarm – enables/disables card’s alarm (beeper)
Enable Staggered drive spinup – enable/disable staggered drive spin-up. Dis-
abled by default. If enabled, the host adapter will spin disks in sequence (one disk, every “x#” of seconds – enter the desired value). Some hard disks do not support this setting – consult the hard disk’s documentation for more information.
Spin down idle disk – If enabled, the host adapter will power down idle (inactive)
disks/arrays based on the allotted time. Specify the value (in minutes)
Rebuild Priority – This option is provided for redundant arrays. This setting
determines the priority of rebuilding arrays in regards to other system tasks.
Provide INT13 support – enable or disable INT13 (the host adapter’s boot
function). Disabling this setting may resolve motherboard BIOS related issues in cases where the card cannot be loaded into memory properly (option ROM/out of memory errors).
32
Page 33
RocketRAID BIOS Utility
Use Single BCV Entry – also related to motherboard BIOS settings (troubleshooting)
Stop on Error – Enabled by default. If disabled, the host adapter BIOS menu will bypass array or device errors when booting the system.
NCQ – enable/disable NCQ (native command queuing)
Device Settings
These options allow the administrator to enable or disable hard disk cache related settings.
From the Disk W indow, highlight the target disk and press Enter. Highlight Disk from the toolbar:
Turn on Write cache – enables the use of the hard disk cache. This is the recom­mended setting
Turn off write cache – disable the use of the hard disk cache. Use this setting for troubleshooting hard disks, or for testing purposes. Disabling disk cache will lower performance
33
Page 34
RocketRAID BIOS Utility
Spare Disks
Spare Disks are used to automatically rebuild Redundant RAID arrays in the case of disk failure. As with creating RAID arrays, disks must be initialized before they can be used as spares. To set a hard disk to act as a Spare Disk, switch to the Disk window, use the arrow keys to select the target disk from the list of initialized disks, and press Enter.
Highlight Disk from the toolbar, then select Toggle Spar e, and press Enter.
T o remove a spare, follow the same procedure. From the Disk window, select the target Spare disk and press Enter. Highlight Disk from the toolbar, select Toggle Spare and press Enter.
34
Page 35
RocketRAID BIOS Utility
Generally, single disks are designated to act as spares (disks that are not configured into RAID arrays).
However, in some instances, disks that are members of RAID arrays may also be assigned to act as a spare disk. If the disks in question are part of a RAID array that did not utilize the full available capacity at the time of creation, these disks may be used as spares. For example: a RAID 0 array was created between two 200GB hard disks, but only 200GB of space (out of a grand total of 400GB), was assigned to that array. In this example, 200GB of disk space remains unallocated. This unallocated space allows these disks to be set as spares for a separate redundant array that meets the capacity requirement (200GB or less).
V erifying Arrays
Routine RAID verification is essential for maintaining the integrity of data stored on redundant RAID arrays. The RocketRAID BIOS utility allows you to manually verify RAID arrays.
From the Array window, highlight the target array and press Enter. Highlight Array from the toolbar, select Verify, and press Enter.
Progress will be displayed towards the lower right-hand corner of the screen (percent complete).
T o stop or pause the verification process, select Stop Task from the same menu. To continue the verification process, select Start T ask .
35
Page 36
RocketRAID BIOS Utility
6 – Additional Functions and Settings
Set Boot
Highlight the target array from the Array window and press Enter. Highlight Array from the toolbar:
Note: Use this option to set an array to act as the boot device. The selected array will act as the boot “disk”, if the motherboard’s BIOS instructs the card to act as the system’s boot device.
Hot-Swap
The BIOS utility provides several options that allow the administrator to add or remove disks and arrays, without powering down the system.
Adding/removing Disks
T o prepare a disk for removal, first highlight the tar get disk using the Disk window and press Enter. Highlight Disk from the toolbar, select Unplug, and press Enter.
36
Page 37
RocketRAID BIOS Utility
T o add a disk, install the hard disk, then highlight Disk from the toolbar, select Rescan, and press Enter.
Note: After installing the disk into the hot-swap capable drive bay, wait several seconds to allow the disk to fully power on, before using the Rescan command.
Adding/removing Arrays
T o prepare a RAID array for removal, highlight the tar get array using the Array window and press Enter. Highlight Array from the toolbar, select Unplug, and press Enter.
The interface will notify you when the disk can be removed.
T o add an array, install all of the RAID hard disks, then highlight Window from the toolbar. Select Refresh, and press Enter.
Note: After installing the hard disks into the hot-swap capable drive bays, wait several seconds to allow the disks to fully power on, before using the Rescan command.
37
Page 38
RocketRAID BIOS Utility
Window Menu
The W indow menu provides several view options.
Maximize – enlarge viewing area of the selected window (Disk or Array)
Minimize – reduce the viewing area of the selected window)
Disk – selects the Disk window
Array – selects the Array window
Refresh – scans for any hardware changes (used when adding arrays or disks to
the card)
38
Page 39
HighPoint RAID Management and Device Driver CD
HighPoint RAID Management and Device Driver CD
Each retail box includes a copy of the HighPoint Products Software CD. This CD can be used to generate driver diskettes, and install the HighPoint RAID
Management Utility Suite for a variety of operating systems.
1 - Creating a driver diskette
Windows 2000, 2003 and several distributions of Linux and FreeBSD require driver diskettes when installing the operating system directly to a disk or array hosted by the Rocket RAID host adapter.
To create a driver floppy diskette:
1. Insert the CD into the system’s CD/DVD drive. The program should start automatically.
2 . Insert a blank floppy diskette into the system’s floppy drive.
3. Click on “Create Driver Diskette”.
4 . Click on the “Please Select a Product” drop-down button, and select the appro-
priate host adapter model from the list.
5. Click on the “Please Select the Diskette you want to create” drop-down button, and select the desired operating system from the list.
6 . Click on the “OK” button to create the driver diskette.
39
Page 40
HighPoint RAID Management and Device Driver CD
2 - Device Driver Installation
We recommend visiting the RocketRAID download page for the latest W indows Device Driver updates:
you can access below website:
http://www.highpoint-tech.cn/China/biosc.htm
Then, RocketRAID controllers are represented,you can press relevant Link to access Product Driver.
Drivers are posted in .zip archive format. Most W indows operating systems will recognize this archive format, natively. Double click the driver download to view and extract their contents. Drivers can be extracted and/or copied to various media.
40
Page 41
HighPoint RAID Management and Device Driver CD
Windows Driver Installation (Win2000, XP, Win 2003)
Before installing the RocketRAID 432x host adapter’s device driver, make sure the host adapter and all required hard disks have been installed into the system’s chassis/ disk enclosure. If you are working with a supplied driver, or driver download, you will want to extract the contents directly to a directory of your choice (or device). You will need to browse to this location, in order to load the driver (see step 2, below).
Installing the RocketRAID 431x/432x driver for an existing Windows system.
After the operating system has booted, Windows will automatically detect the RocketRAID 431x/432x host adapter, and request that a device driver be installed. To install the device driver, follow the steps outlined below:
1. When the “Found New Hardware Wizard” window appears, select “Install from a list or specific location (Advanced)”, and click Next to continue.
2. Click on the “Include this location in the search” option, and select the system’ s floppy drive (generally Disk A). Next, insert the Driver Installation diskette into the system’s floppy drive, or select Browse, and browse to the location of the driver. If you are using the RocketRAID 431x/432x software CD, the drivers
are located in RR3xxx_4xxx – Windows –Driver– Windows (then select the appropriate folder).
3 . Windows may display a warning message that states the driver has “not been
signed”. Select “Continue Anyway”, then click Finish when prompted. When
windows asks to reboot the system, choose No.
4. emove the Driver Installation diskette from the floppy drive, then Shut down and restart the computer.
41
Page 42
HighPoint RAID Management and Device Driver CD
Installation V erification
After the driver has been installed, and the system has been restarted:
1. Click the Start button, then right-click the “My Computer” icon. Select the Properties item from the pop up menu.
2. In the popup window, click the “Hardware” tab then click Device Manager button.
3. Double click the “SCSI and RAID controllers” entry. If the RocketRAID 431x/ 432x device entry is not displayed, or there are “?” or “!” marks displayed near the RocketRAID 431x/432x entry, the driver has not been installed properly. Delete the entries and reinstall the driver.
Installing the RocketRAID driver during a fresh Windows installation
1. After booting from the W indows CD or DVD-ROM, when the Windows Setup blue screen appears, look towards the bottom of the screen. Windows will prompt you to press the F6 key if you want to install a third party SCSI or RAID driver. Press the F6 key at this time.
2 . The setup procedure will continue, and will later instruct you to press the “S”
key to specify additional adapters. Press the “S” key as instructed.
3. Next, the setup program will prompt for the insertion of the driver diskette. Please insert the driver diskette, and then press ENTER to continue.
4. The next window will display several driver options. Please select the driver for the corresponding operating system, and press ENTER to continue.
42
Page 43
HighPoint RAID Management and Device Driver CD
Windows V ista/2008 Driver Installation
Installing the driver during a fresh Windows Vista/2008 installation
1. Boot from Windows V ista DVD.
2. When the screen “where do you want to install Windows” appears, click “Load driver” and browse for the driver location. W indows Vista will accept install drivers from various sources: floppy diskette, USB flash disk or CD. If you are
using the RocketRAID 431x/432x software CD, the drivers are located in RR3xxx_4xxx – Windows-Driver – VistaWin2008 – 32 (or 64, if you are running a 64-bit version of the operating system).
3. Select the RocketRAID 431x/432x controller driver, and click “Next”.
4. The driver is now installed – you can now commence with the standard OS installation procedures.
Installing the driver for an existing Windows Vista/2008 system
1. Intall the RocketRAID 431x/432x host adapter into the PC, then boot up Windows.
2 . Windows should automatically detect the card, and display the “Found New
Hardware” wizard pop-up window. Select “Locate and install driver software”. When Windows asks: “W indows needs your permission to continue”, select “continue”.
3 . Select “I don’t have disc, show me other options” and then select “Browse my
computer for driver software”.
4. Specify the location of the driver and click “Next. If you are using the
RocketRAID 431x/432x software CD, the drivers are located in RR3xxx_4xxx – Windows-Driver – VistaWin2008 – 32 (or 64, if you are running a 64-bit version of the operating system).
5 . When asked: “Would you like to install this driver software?” select “Install”.
6. Reboot the system when prompted. The RocketRAID 431x/432x will be available for use after Windows reboots.
43
Page 44
HighPoint RAID Management and Device Driver CD
Installation V erification
After the driver has been installed, and the system has been restarted:
1. Click the Start button, then right-click My Computer icon. Select the Properties item from the popup menu.
2 . In the popup window, select Hardware tab and then click Device Manager
button.
3. Double click the “Storage Controllers” entry. If the RocketRAID 431x/432x device entry is not displayed, or there are “?” or “!” marks displayed near the RocketRAID 431x/432x entry, the driver has not been installed properly. Delete the entries and reinstall the driver.
44
Page 45
HighPoint RAID Management and Device Driver CD
Linux and FreeBSD Device Driver installation
The RocketRAID 431x/432x host adapter is fully GPL compliant, and is natively support by Linux kernel 2.6.25x. Linux distributions that utilize this kernel (and all later releases) will automatically recognize the host adapter, and do not require driver installation.
In addition, binary and source driver updates are routinely posted for a variety of older Linux operating systems including past versions of Red Hat Enterprise, CentOS, OpenSuSE, and Fedora Core.
Drivers are also available for several FreeBSD revisions, and are available from the same support page:
you can access below website:
http://www.highpoint-tech.com/USA/bios.htm
Then,RocketRAID controllers are represented,you can press relevant Link to access Product Driver.
Several driver sets are included with the RocketRAID 431x/432x Software CD. Each binary driver and source package includes an installation guide (.pdf format).
45
Page 46
HighPoint RAID Management and Device Driver CD
Linux Driver sets:
RR3xxx_4xxx/Linux directory.
FreeBSD Driver sets:
RR3xxx_4xxx/FreeBSD directory.
3 - HighPoint RAID Management Utilities (HRM)
The HighPoint RAID Management Utility Suite, also known as “HRM”, includes several user interface options. The latest version of the Web Management utility user manual, is available from our website.
Windows Operating Systems – Installing the Web-based Manage­ment Utility
Click on “Install RAID Management Software”.
Select the desired software from the drop down menu, and click on the “OK” button.
46
Page 47
HighPoint RAID Management and Device Driver CD
Red Hat Enterprise/CentOS, Fedora Core, Open SuSE – Installing the W eb-based Management utility
Linux operating systems that support .rpm packages, allow you to double-click the HighPoint Web RAID Management .rpm file to start the installation process.
1. Copy the W eb RAID Management package from the RocketRAID 431x/432x Software CD, to the desktop of the Linux operating system. The .rpm file is located in HighPoint RAID Management Software – RR3xxx_4xxx - Linux – W ebGui-Linux.tbz.
2. Extract the .tbz file to the desktop, and browse to the appropriate .rpm file (there are 32 and 64-bit options).
3 . Double click the .rpm file – this should open the operating systems’ software
installer. Enter the Administrative password when prompted and proceed with installation.
4. The package can also be installed manually, using a terminal. Lon in as “root”, open a terminal, and browse to the location of the .rpm file. Run the following command:
5. # rpm -i hptsvr-https-1.4-8.i386.rpm (or hptsvr-https-1.4-8.x86_64.rpm)
Note: The i386 rpm package can also work on 64-bit systems if you have 32-bit runtime libraries installed. If you use the x86_64 rpm package, please make sure the controller driver has 64-bit ioctl support.
47
Page 48
HighPoint RAID Management and Device Driver CD
Debian/Ubuntu Linux Distributions – Installing the W eb-based Management Utility
For Debian/Ubuntu Linux distributions, you can use alien to convert the rpm pack­ages to a .deb package, then use “dpkg -i” command to install each package. Some script files may be lost during the conversion process from rpm to .deb, so you may need to make manual corrections.
The following files will be installed/configured:
/usr/bin/hptsvr - service program /etc/hptcfg - service config file /etc/rc.d/init.d/hptdaemon - service control script /usr/share/hpt/webguiroot - data files
If there is no /etc/hptcfg present, you can add it manually using by using the “echo” command on the driver file name to /etc/hptcfg.
For example: # echo hptiop.ko >/etc/hptcfg
Uninstalling the Utility
Open a terminal, and use the following command: # rpm -e hptsvr-https
Linux Distributions – Command Line Interface (CLI)
Command Line interface versions of the RocketRAID management utilities are available for Linux and FreeBSD operating systems.
These packages are posted on the HighPoint Technologies, Inc. website, under the BIOS & Driver downloads page for the RocketRAID 431x/432x.
48
Page 49
HighPoint RAID Management and Device Driver CD
Mac OS X Driver and Web-based RAID Management Utility
The driver and software packages for the RocketRAID 431x/432x includes both the device driver for OS X, and a copy of the Web RAID Management utility.
Please check http://www.hptmac.com for the latest software/driver packages. Driver updates are posted on the card’s product page, under the “Download Center” section. The latest package is posted towards the right-hand side of the page, under “Mac Driver”. On the left-hand side of the page, there is a section devoted to user documentation. The latest versions of the Product, and Web-based RAID Manage­ment Manuals are posted here.
49
Page 50
HighPoint RAID Management and Device Driver CD
Mac OS X Driver and RAID Management Installation
The driver and software packages for the RocketRAID 431x/432x includes both the device driver for OS X, and a copy of the Web RAID Management utility. Copy the Mac driver and software package from the Software CD, to the Mac Desktop. Open the .dmg file, and double click “rr3xxx_4xxx” to begin installation.
Click “Continue” to proceed with installation
50
Page 51
Select the installation destination:
Click “Continue”
HighPoint RAID Management and Device Driver CD
Click “Restart” – after OS X reboots, the card will be recognized by the system. Config­ure arrays using the Web RAID Management interface. User guides for the Web inter­face are available from http://www.hptmac.com. Check the product page for the RocketRAID 431x/432x, and click on the “Download Center” link. If the users have more requirements to boot from the Host Adapter,please performing below step.
51
Page 52
HighPoint RAID Management and Device Driver CD
Configure the cards to support booting OS X, fo Mac Pro systems Updating the Rocket RAID Firmware – EFI
For RocketRAID 35xx and 4xxx host adapters
1) Log into RAID Management Utility (W eb GUI). Open a web browser (such as Safari or Firefox) and enter the following URL: http://localhost:7402
2) Once connected click on the Access URL – this will open the log in screen.
3) Type in the User name and Password, then click “OK”. The default Username is
RAID, while the default Password is hpt.
4) After successfully logging in, the Web GUI will display the Manage – Array screen. Select Manage – Device from the menu, and scroll to the bottom of this page and locate the Update Firmware function.
5) Click on the Browse button, and browse to the location of the EFI firmware update. The EFI firmware is the second file included with Driver and Firmware download (see step 3).
52
Page 53
HighPoint RAID Management and Device Driver CD
6) Select the firmware update (.blf file) and click the Submit button. The interface will
notify you when the update is complete. Exit the Web GUI and reboot OS X.
Cloning the boot volume to a RAID Array
1) After flashing the EFI firmware update, download Carbon Copy Cloner. Carbon
Copy Cloner is a free disk imaging utility that can be used to duplicate the system’s current boot volume, to a disk or RAID array attached to the RocketRAID card. http://
www.bombich.com/software/ccc.html
2) Clone OS disk to disk on RAID array
53
Page 54
HighPoint RAID Management and Device Driver CD
3) Start Carbon Copy Cloner. For the Source disk, select the current Mac OS X boot drive. For the Target disk, select a disk or array attached to the RocketRAID host adapter.
54
Page 55
HighPoint RAID Management and Device Driver CD
4) Once the Source and Target disks have been selected, click Clone to start the
duplication process. The utility will display a progress bar and notify you when the copy procedure is complete.
Change the boot volume
1) After cloning the boot volume, open the System Preferences window and selectStartup Disk”.
55
Page 56
HighPoint RAID Management and Device Driver CD
2) Set the RAID array or disk attached to the RocketRAID card as the startup disk, and click “Restart”.
3) You can also select the boot volume using the Alt key, after powering up the Mac system. This command will display available boot volumes.
56
Page 57
Customer Support
Customer Support
If you encounter any problems while utilizing the RocketRAID host adapter, or have any questions about this or any other HighPoint product, feel free to contact our Customer Support Department.
Troubleshooting Checklist
Before contacting our Customer Support department:
Make sure the latest BIOS, driver and HighPoint RAID Management soft-
ware has beein installed for the host adapter. The latest updates are available from our website.
Prepare a list of the computer system’s hardware and software (motherboard,
CPU, memory, other PCI-E devices/host adapters, operating system, applications)
Contact Information
E-mail address: support@highpoint-tech.com Phone: 408-240-6119
9:00AM-5:00PM, Pacific Standard Time
57
Page 58
Customer Support
Contact Us
HighPoint Corporate Headquarter USA
Address 1161 Cadillac Ct. Milpitas, CA, 95035
Website: http://www.highpoint-tech.com Phone: 1-408-942-5800 (9 am ~ 6 pm PST, M-F) Fax: 1-408-942-5801 E-mail: sales@highpoint-tech.com Support: support@highpoint-tech.com Support Phone: 1-408-240-6108 (9 am ~ 5 pm PST, M-F)
HighPoint Taiwan
5F., No.3, Swei Lane , Jhongjheng Rd. Sindian City, T aipei County 231, T aiwan (R.O.C.)
Website: http://www.highpoint-tech.com/Taiwan/indextw.htm Phone: + 886-2-2218-3435 (9 am ~ 6 pm) Fax: + 886-2-2218-3436 E-mail:sales@highpoint-tech.com Support: support@highpoint-tech.com
HighPoint China
4th Floor Kehaifulin Building, N0. 12 Zhong Guan Cun South Rd. Haidian District Beijing, China 100081
Website: http://www.highpoint-tech.cn/ Phone: + 86-10-6213-0920 (9 am ~ 6 pm) Fax: + 86-10-6897-5074 E-mail: sales@microaurora.com.cn Support: support@microaurora.com.cn
58
Page 59
Customer Support
FCC Part 15 Class B Radio Frequency Interference statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interfer­ence to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interfer­ence to radio or television reception, which can be determined by turning the equip­ment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help. Modifications not expressly approved by the manufacturer could void the user’s
authority to operate the equipment under FCC rules. This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
European Union Compliance Statement
This Information Technologies Equipment has been tested and found to comply with the following European directives:
European Standard EN55022 (1998) Class B European Standard EN55024 (1998)
59
Page 60
Customer Support
Thank Y ou
Thank you for purchasing the RocketRAID 431x/432x SAS/SATAII RAID Host adapter. We appreciate your support, and welcome any questions, comments or product suggestions you may have.
60