INSTALLATION GUIDE
HID Signo™ Reader
13.56 MHz / 125 kHz / 2.4 GHz Contactless and Keypad Readers |
|
SRD Models: 20, 20K, 40, 40K |
PLT-03703, Rev. A.2 |
www.hidglobal.com/PLT-03704
Scan the QR code or visit the link to see the multi-language electronic version of this document.
Lisez le code QR ou suivez le lien pour consulter la version française de ce document.
Escanee el código QR o visite el vínculo para consultar la versión en Español de este documento.
Scannen Sie den QR-Code oder öffnen Sie den Link für die deutsche Version dieses Dokuments.
Supplied parts
Faça a leitura do código QR ou acesse o link da versão em português deste documento.
Scansiona il codice QR o visita il link della versione Italiana di questo documento.
Отсканируйте QR-код или пройдите по ссылке, чтобы получить версию этого документа на русском языке.
QR
QR
QR .
HID Signo Reader (1) |
Flat head/countersunk M3.5 x 12mm machine |
|
Installation Guide (1) |
|
screws (2) – for Metric (EU etc) junction box |
Flat head/countersunk 0.138-20 x 1.5" self– |
|
installation |
tapping screws (2) – for installing the reader |
Flat head/countersunk 0.138-32 x 0.375" |
|
directly to a wall (no junction box) |
|
security screw (1) – alternative anti-tamper |
Flat head/countersunk 0.138-32 x 0.375" |
|
screw for attaching the reader to the |
machine screws (3) – for Imperial (US) |
|
mounting plate |
junction box installation (2) and attaching |
5-pin terminal connectors, terminal strip |
|
the reader to the mounting plate (1) |
|
models only (2) |
Recommended parts (not supplied) |
||
Cable, 5-10 conductor (Wiegand or |
Drill with various bits for mounting hardware |
|
Clock and-Data), 4 conductor Twisted Pair |
|
Mounting hardware |
Over-All Shield and UL approved, Belden |
Reader spacer when mounting on or near |
|
3107A or equivalent (OSDP) |
|
metal or metal junction boxes. Refer to the |
Certified LPS DC power supply |
|
Reader and Credentials How to Order Guide |
Metal or plastic junction box |
|
(PLT-02630) for available options and part |
Security tool HID 04-0001-03 (for |
|
numbers) |
anti tamper screw) |
|
Junction box |
© 2019 – 2020 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID Brick logo, the Chain Design, HID Signo, HID Reader Manager, iCLASS, and HID Mobile Access are trademarks or registered trademarks of HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other countries and may not be used without permission. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
Optional features
Tamper – Enabled by default and activated when the mounting plate is removed. The tamper is normally closed and changes to open circuit between Tamper 1 and Tamper 2 control lines. Tamper 1 and Tamper 2 control lines are interchangeable. Either of these lines can be connected with the reader ground line to reduce the number of cable cores required in the reader cable. Tamper 1 and Tamper 2 are rated 0–12VDC at 100mA.
Hold Input – When asserted, this line either buffers a card (default) or disables a card read until released, as configured.
1 Mount the mounting plate
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
CAUTION: Install the reader on a flat, stable surface. Failure to do so may compromise
the IP rating and/or tamper feature. If mounting on
or near metal, a spacer is recommended for optimal read performance. Refer to the
Readers and Credentials How to Order Guide (PLT-02630) for available options and part numbers.
CAUTION: Use the supplied screws to ensure correct fitting and to avoid damaging the reader or mounting plate. HID is not responsible for damage due to use of unapproved mounting hardware.
For Imperial (US):
Use supplied flat head/ countersunk 0.138 32 x 0.375" screws.
For Metric (EU etc):
Use supplied flat head/ countersunk M3.5 x 12mm screws.
2 Wire the reader
Pigtail versions |
Terminal strip versions |
|||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
18"
(0.46m)
|
|
|
|
|
|
|
|
|
|
PIGTAIL |
TERMINAL |
DESCRIPTION |
|
|
|
|
|
|
|
Red |
1 |
+VDC |
|
|
|
|
|
|
|
Black |
2 |
Ground (RTN) |
|
|
|
|
|
|
|
White |
3 |
Wiegand Data 1 / Clock / RS485-A* |
|
|
|
|
|
|
|
Green |
4 |
Wiegand Data 0 / Data / RS485-B* |
|
|
|
|
|
|
|
Orange |
5 |
LED Input (GRN) |
|
|
|
|
|
|
|
Yellow |
6 |
Beeper Input |
|
|
|
|
|
|
|
Blue |
7 |
Hold Input / LED Input (BLUE)* |
|
|
|
|
|
|
|
Brown |
8 |
LED Input (RED) |
|
|
|
|
|
|
|
Violet/White |
9 |
Tamper 2 (RLY2) |
|
|
|
|
|
|
|
Violet |
10 |
Tamper 1 (RLY1) |
|
|
|
|
|
|
|
Bare |
— |
Drain (pigtail models only) |
|
|
|
|
|
|
|
*Dependent upon reader configuration.
Note: Wiring the reader incorrectly may permanently damage the reader.
Note: Previous iCLASS® readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When upgrading to a HID Signo reader, ensure proper connections as defined above.
Note: Data 0 and Data 1 wires for Wiegand may be reused for OSDP. However, standard Wiegand cable may not meet RS485 twisted pair recommendations.
Note: For OSDP cable lengths greater than 200 ft (61 m) or EMF interference, install 120Ω +/- 2Ω resistor across RS-485 termination ends.
Note: For keypad configuration, with the keypad reader operating as 26 bit emulation, enter the facility code followed by # within five seconds of power-up. The facility code must be entered as three digits (i.e., for a facility code of 10 enter 0-1-0-#). If unsuccessful, the reader LED displays solid red. Power cycle the reader and retry entering the facility code.
HID Signo readers use facility codes between 1-255, and no default is set. Once a facility code is entered, the reader LED displays violet, then solid red. Then, power-cycle the reader. If there are two short beeps after entering a PIN, the reader facility code is not configured. In this case, power-cycle the reader and retry entering the facility code.
3 Secure the reader to the mounting plate
1
1. Hook the top of the reader on the top of the mounting plate.
2. Align the bottom of the reader with the bottom of the mounting plate.
3. Secure the reader to the mounting plate using the supplied 0.138-32 x 0.375" screw.
Security/anti-tamper screw:
0.138-32 x 0.375" screw (supplied).
Non-security/standard screw:
0.138-32 x 0.375" screws (supplied).
2 |
3 |
|
4 Power and test the reader
Power the reader. The reader will |
Test the reader with a credential. The reader |
beep and the LED will flash. |
will beep and the LED will flash. |
hidglobal.com |
An ASSA ABLOY Group brand |
Specifications
|
20 |
|
20K |
|
40 |
|
40K |
INPUT VOLTAGE (V DC) |
|
|
12V DC |
|
|
||
CURRENT |
|
|
|
|
|
|
|
STANDBY AVG1 |
60 mA |
|
65 mA |
|
65 mA |
|
70 mA |
|
|
|
|||||
MAX AVG2 |
70 mA |
|
75 mA |
|
75 mA |
|
80 mA |
PEAK3 |
250 mA |
|
250 mA |
|
250 mA |
|
250 mA |
OPERATING |
|
|
-30° F to 150° F (-35° C to 66° C) |
|
|
||
TEMPERATURE |
|
|
|
|
|||
|
|
|
|
|
|
|
|
CABLE LENGTH |
|
|
Communication Lines |
|
|
||
|
|
|
Wiegand = 500 ft - 18 AWG (152 m) |
|
|
||
|
|
|
300 ft - 20 AWG (91 m) |
|
|
||
|
RS-485 = Max bus length: 4,000 ft - 24 AWG (1,219 m) |
||||||
|
Max length between nodes: 1,640 ft - 24 AWG (500m) |
||||||
|
|
|
|
|
|
|
|
REGULATORY REF |
20 |
|
20K |
|
40 |
|
40K |
NUMBER |
|
|
|
||||
|
|
|
|
|
|
|
|
FREQUENCY |
|
BLE: 2.4–2.480 GHz, HF: 13.56 MHz, LF: 125 kHz |
|||||
|
|
|
|
|
|
|
|
FCC IDS |
JQ6-SIGNO20 |
|
JQ6-SIGNO20K |
|
JQ6-SIGNO40 |
|
JQ6-SIGNO40K |
IC IDS |
2236B-SIGNO20 |
2236B-SIGNO20K |
|
2236B-SIGNO40 |
|
2236B-SIGNO40K |
1 Standby AVG - RMS current draw without a card in the RF field.
2 Maximum AVG - RMS current draw during continuous card reads. Not evaluated by UL. 3 Peak - highest instantaneous current draw during RF communication.
Regulatory UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment. Suitable for outdoor use.
Only Wiegand, OSDP, and Bluetooth communications have been evaluated by UL.
HID Signo readers are compatible with HID Mobile Access® version 3.0.0 and later using mobile devices with BLE version 4.2 and later listed at: https://www.hidglobal.com/mobile-access-compatible-devices.
Install in accordance with NFPA70 (NEC) Local Codes, and authorities having jurisdiction. Follow all National and Local Codes.
UL 294 Performance Levels
|
ACCESS |
|
|
|
|
|
|
CONTROL |
DESTRUCTIVE |
ENDURANCE |
STAND-BY |
|
|
MODEL # |
LINE |
ATTACK |
CONDITIONS |
|||
LEVEL |
POWER LEVEL |
|||||
|
SECURITY |
LEVEL |
|
|
|
|
|
LEVEL |
|
|
|
|
|
20 / 20K / 40 / 40K |
Level I |
Level I |
Level IV |
Level I |
|
FCC
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Any changes or modifications to this device not explicitly approved by the manufacturer could void your authority to operate this equipment.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Canada Radio Certification
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
CE Marking
HID Global hereby declares that these proximity readers are in compliance with the essential requirements and other relevant provisions of Directive 2014/53/EU.
Por el presente, HID Global declara que estos lectores de proximidad cumplen con los requisitos esenciales y otras disposiciones relevantes de la Directiva 2014/53/EU.
HID Global déclare par la présente que ces lecteurs à proximité sont conformes aux exigences essentielles et aux autres stipulations pertinentes de la Directive 2014/53/EU.
A HID Global, por meio deste, declara que estes leitores de proximidade estão em conformidade com as exigências essenciais e outras condições da diretiva 2014/53/EU.
HID Global bestätigt hiermit, dass die Leser die wesentlichen Anforderungen und anderen relevanten Bestimmungen der Richtlinie 2014/53/EU erfüllen.
HID Global dichiara che i lettori di prossimità sono conformi ai requisiti essenziali e ad altre misure rilevanti come previsto dalla Direttiva europea 2014/53/EU.
Download copies of the Radio Equipment Directive Declaration of Conformity (DoC) at: http://www.hidglobal.com/certifications
Taiwan
According to “Administrative Regulations on Low Power Radio Waves Radiated Devices” Without permission granted by the NCC, any company, enterprise, or user is not allowed to change frequency, enhance transmitting power or alter original characteristic as well as performance to a approved low power radio-frequency devices. The low power radio-frequency devices shall
not influence aircraft security and interfere legal communications; If found, the user shall cease operating immediately until no interference is achieved. The said legal communications means radio communications is operated in compliance with the Telecommunications Act. The low power radio-frequency devices must be susceptible with the interference from legal communications or ISM radio wave radiated devices.
Korean KCC |
|
||
|
|
|
20, 20K, 40, 40K |
|
|
|
|
|
|
|
RFID:13.56 MHz |
|
|
|
RFID:13.56 MHz |
|
|
|
RFID: 10m 47.544mv |
|
|
|
DC 12.0V |
|
|
|
A1D |
|
|
|
X-tal |
|
|
|
RFID: ASK, NFC: GFSK |
Russia
Дата изготовления указана на маркировке оборудования
Представитель в Российской Федерации
Название |
ООО «Дофин» |
Адрес |
140573, РФ, Московская обл., Озерский район, с. Бояркино |
Контактное лицо |
Л.Н. Голубова |
Телефон |
+7 495 223 6008 |
local.declarant@gmail.com |
Japan MIC
“ ” ( AC- )RFID
Israel
השימוש במכשיר הינו על בסיס ״משני״ ופטור מרשיון הפעלה אלחוטי.
רק ״בפעולת בזק״ לשימוש עצמי של הלקוח בלבד, הלקוח פטור מרשיון הפעלה אלחוטי. אסור להחליף את האנטנה המקורית של המכשיר, ולא לעשות בו כל שינוי טכני אחר.
Brazil
Compliance Statement
Este produto está homologado pela ANATEL, de acordo com os procedimentos regulamentados pela Resolução 242/2000, e atende aos requisitos técnicos aplicados. Para maiores informações, consulte o site da ANATEL - www.anatel.gov.br
This product is homologated at ANATEL according to procedure regulated by Resolution 242/2000, and it complies with the applicable technical requirements. For more information, consult ANATEL website - www.anatel.gov.br
RF Warning Statement
Per Article 6 of Resolution 506, equipment of restricted radiation must carry the following statement in a visible location:
Este equipamento opera em caráter secundário, isto é, não tem direito a proteção contra interferência prejudicial, mesmo de estações do mesmo tipo, e não pode causar interferência a sistemas operando em caráter primário.
This equipment operates in secondary character, meaning it does not have the right of protection against harmful interference, even against those the same character, and it cannot cause any interference to systems operating in the primary character.
Singapore |
Australia and New Zealand |
|
|
Complies with |
|
IMDA Standards |
|
DB106440 |
E4662 |
|
|
Powering
Trusted Identities
PLT-03703, Rev. A.2
Americas & Corporate |
Asia Pacific |
|
|
|
|
Europe, Middle East & Africa |
Brazil |
|||||||
611 Center Ridge Drive |
19/F 625 King's Road |
|
|
|
|
Phoenix Road |
Condomínio Business Center |
|||||||
Austin, TX 78758 |
North Point, Island East |
|
|
|
|
Haverhill, Suffolk CB9 7AE |
Av. Ermano Marchetti, 1435 |
|||||||
USA |
|
Hong Kong |
|
|
|
|
|
United Kingdom |
Galpão A2 - CEP 05038-001 |
|||||
Support: |
866-607-7339 |
Support: |
852-3160-9833 |
|
|
|
|
Support: |
44 (0) 1440 711 822 |
Lapa - São Paulo / SP |
||||
Fax: |
949-732-2120 |
Fax: |
852-3160-4809 |
|
|
|
|
Fax: |
44 (0) 1440 714 840 |
Brazil |
||||
|
|
|
|
|
|
|
|
Phone: +55 11 5514-7100 |
||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
15 |
|
|
|
Equipment |
|
|
General Signaling |
|
||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
E4662 |
|
|
|
|
8T2 9 |
|
|
Equipment |
|
||
hidglobal.com |
|
|
|
|
|
ACC Control READER |
|
|
|
|
|
CIDF18000157 |
||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
|
|
|
|
|
|
|
|
|||||
|
|
An ASSA ABLOY Group brand |
||||||||||||
|
|
|