HID iCLASS SE, multiCLASS SE, R10E, RP10E, R15E Installation Manual

...
Page 1
INSTALLATION GUIDE
iCLASS SE® / multiCLASS SE®
R10E, RP10E, R15E, RP15E, R40E, RP40E, RK40E, RPK40E R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
Parts
1 – iCLASS SE/multiCLASSS SE Reader 1 – Installation Guide 2 – #6-32 x .375” Phillips machine screws 3 – #6-32 x .375” spanner security screw 2 – 7-pin Terminal connectors 1 – 10-pin Terminal connector
Recommended
• Cable, 5-9 conductor (Wiegand or Clock-and-Data), 4 conductor Twisted Pair Over-All Shield and UL approved, Belden3107A or equivalent (OSDP)
• Linear DC power supply
• Metal or plastic junction box
• Security tool (for anti-tamper screw) HID 04-0001-03
• Drill with various bits for mounting hardware
• Mounting hardware
• Reader spacer when mounting on or near metal or metal junction boxes ­see How to Order Guide
• IP65 Mounting gasket, recommended for outdoor installation
• Back box
PLT-01579 A.4
Specification
MAX AVG
3
1
PEAK
200mA
220mA
OPERATING
TEMPERATURE
4
-30° to 150° F
(-35° to 65° C)
5
CABLE LENGTH
Communication Lines
Wiegand = 500 ft - 22 AWG (152 m)
300 ft - 24 AWG 91 m)
RS-485 = Max bus length
4000 ft - 24 AWG (1,219 m) Max length between nodes:
1640 ft - 24 AWG (500m)
UL Reference Number Deciphering x
Reader Colors: K = Black
1
x
Wiring: N = Pigtail
2
Communications: N = No Module
x
3
FCC-ID: JQ6-ICLASSBTM IC-ID: 2236B-ICLASSBTM
6
REGULATORY
REF NUMBER
R10Ex
1x2x3
RP10Ex
1x2x3
1x2x3
RP15Ex
1x2x3
3
RP40Ex
1x2x3
RK40Ex
1x2x3
RPK40Ex
1x2x3
T = Terminal 5 = 5 meter Pigtail
R = RS-485 (OSDP) L = Indala Prox B = Bluetooth
PRODUCT
7
R10
7
RP10
R15 910N 60mA 95 mA R15Ex
7
RP15
7
R40
7
RP40
RK40 921N
7
RPK40
1 Communication protocols other than Wiegand or Clock & Data
(for control panels), as well as credential interfaces over BLE (not applicable for 9xxL models), require an additional
hardware module which increases current by 40mA. 2 Standby AVG - RMS current draw without a card in the RF field. 3 Maximum AVG - RMS current draw during continuous card reads.
Not evaluated by UL.
BASE PART
NUMBER
900N
900P 75mA 100mA
900L 110mA 135mA
910P 75mA 100mA
910L 110mA 135mA
920N 65mA 95mA R40Ex1x2x
920P 85mA 100mA
920L 120mA 145mA
921P 95mA 105mA
921L 130mA 155mA
INPUT
VOLTAGE (VDC)
5 - 16VDC
5.5 - 16VDC
CURRENT
STANDBY
2
AVG
60mA 95mA
85mA 100mA
4 Peak - highest instantaneous current draw during RF communication. 5 When configured for Bluetooth Operating Range is -13° to 150° F
(-25° to 65° C)
6 Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC 500 ft (152 m) 22 AWG @ 6.5 - 16VDC
7 Mobile Enabled Products, see specifications below.
BTSmart Specifications
OPERATING TEMPERATURE FREQUENCY FCC & IC IDS
-15° to 150° F (-25° to 65° C) 2.4 - 2.480 GHz
The final product, containing the modular transmitter must be labeled with its own FCC ID and IC ID. If the FCC & IC ID is not visible, when the module is installed inside another device, then the final assembly label must contain the FCC and IC ID numbers with a statement such as follows: “Contains Transmitter Module with FCC ID JQ6-ICLASSBTM and IC ID 2236B-ICLASSBTM”.
This Installation Guide is for informational purposes only. HID makes no warranties, expressed or implied, in this summary. Company, product names and data used in sample output are fictitious. Specifications are subject to change without notice. © 2014 - 2016 HID Global Corporation/ASSA ABLOY AB. All rights reserved. HID, the HID logo, and iCLASS SE are trademarks or registered trademarks of HID Global in the U.S. and/or other countries. All other trademarks, service marks, and product or service names are trademarks or registered trademarks of their respective owners.
hidglobal.com An ASSA ABLOY Group brand
Page 1
Page 2
INSTALLATION GUIDE
R10E, RP10E, R15E, RP15E, R40E, RP40E, RK40E, RPK40E, R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
iCLASS SE/multiCLASS SE PLT-01579 A.4
1 Mounting
2 Wiring
DRAIN (BARE)
+VDC (RED)
HOLD (BLU)
BEEP (YEL)
GRN (ORG)
RED (BRN)
GND (BLK)
DATA0/DATA (GRN)
GPIO1 (RED/GRN)
DATA1/CLK(WHT)
OC/TMPR (VIO)
GPIO4 (GRAY)
GPIO3 (PINK)
GPIO2 (TAN)
Junction box not included
Gasket optional
18 in
(0.46 m)
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
BEEP
+VDC
DRAIN
HOLD
GPI01
GRN
GPI02
GND
OC/TMPR DATA1/CLK DATA0/DATA
RED
GPI03 GPI04
DRAIN
HOLD
+VDC
BEEP
GRN
GND
RED
P1
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04
P2
3 Install Reader to Backplate
4 Power & Testing
Turn on power Test card
PIGTAIL*** TERMINAL DESCRIPTION
Yellow P1-1 Beeper Input
Orange P1-2 LED Input (GRN)
Black P1-3 Ground (RTN)
Red P1-4 +VDC
Drain P1-5 Unused
Brown P1-6 LED Input (RED)
Blue P1-7 Hold Input
Red/Green P2-7 GPI01/OSDP (RS485-FDX/HDX-A)
Tan P2-6 GPI02/OSDP (RS485-FDX-HDX-B)
Violet P2-5 *Open Collector Output/Tamper
White P2-4 **Wiegand Data 1 / Clock
Green P2-3 **Wiegand Data 0 / Data
Pink P2-2 GPI03 (RS485-FDX-Z)
Note: Previous iCLASS readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When upgrading to an iCLASS SE reader, ensure proper connections as defined below.
Note: It’s possible to reuse existing Wiegand wiring for OSDP, however, using simple s usually not meeting the RS485 twisted pair recommendations.
Note: For OSDP cable lengths greater than 200ft. (61M) or EMF interference, install 120 +/- 2 resistor across RS-485 termination ends.
tranded cable typical of Wiegand access control readers is
Note: Wiring the reader incorrectly may permanently damage the reader.
Note: With a keypad reader, operating as 26 bit emulation; upon power up
you have 5 seconds to enter the facility code followed by #. If unsuccessful, the reader LED displays solid Red. Power-cycle the reader and retry entering the facility code.
The facility code needs to be manually entered as 3 digits (i.e. if facility code is 10 enter 0-1-0-#). Note: SE readers only use facility codes between 1-255, and there is no default facility code. Once the facility code has been entered, the LED will display Violet and then to a final Red. Then power­cycle the reader. Note: When using a keypad, if there are 2 short beeps after entering your PIN, the reader does not have a facility code configured yet. In this event, an Admin will need to be power-cycle the reader and enter the facility code before the reader will accept your PIN.
Gray P2-1 GPI04 (RS485-FDX-Y)
* Tamper Output. When activated, output syncs to ground (default). ** Dependent upon reader configuration. See HTOG Wiegand and Clock-and-Data
configurations for more information. *** For 5 meter pigtail readers, PN: 9xxxxxLEKxxxxx follow the wiring diagram on the reader.
Optional Features
Open Collector Output - Controls an external device (5 VDC) operating in Host Mode only. Sink – 40mA / Source – 1mA.
Optical Tamper – A configuration card is necessary to activate the Optical Tamper. Once activated, and when the mounting plate is removed, the Optical Tamper is activated. Contact HID Technical Support for Optical Tamper options.
Configuration Cards – With the use of configuration cards, the reader can be modified to meet the specific requirements of an installation. Configuration options include; audio visual, CSN outputs and keypad outputs (keypad models only). Contact HID Technical Support for all reader configuration options.
Hold Input – when asserted, this line either buffers a card or disables a card read until released, as configured.
hidglobal.com An ASSA ABLOY Group brand