Parts List
1 - Reader and base plate assembly
1 - Installation guide
2 - Terminal connector - terminal readers only
RKCL40, RPKCL40, RKCLB40, and RPKCLB40
4 - M3.5 mm x 12 mm phillips machine screw
4 - #6-32 x .375” phillips self-tapping machine screw
4 - #6 x 1.5” phillips sheet metal screw
3 - #6-32 x .4375” spanner security screw, anti-tamper (Black)
3 - #6-32 x .4375 phillips security screw (Black)
1 - Mounting Gasket
R10, RP10, R15, RP15, R30, RP30, R40, RK40, RP40, and RPK40
2 - M3.5 mm x 12 mm phillips machine screw
3 - #6-32 x .375” phillips self-tapping machine screw
2 - #6 x 1.5” phillips sheet metal screw
1 - #6-32 x .375” spanner security screw, anti-tamper
1 - Mounting gasket - (Optional)
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm]
(Belden 3108A or equivalent) - RS-485 + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm]
(Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box - RPKCL40 / RPKCL40 /
RKCLB40 / RPKCLB40
• Metal or plastic single-gang junction box - R10 / RP10 / R15 / RP15 / R30 /
RP30 / R40 / RP40 / RK40 / RPK40
• Reader spacer when using metal junction boxes - see HID HTOG.
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
pivCLASS Protocol
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
R10-H 900NHR
RP10-H 900PHR 75mA RP10Ex 1x2x
R15-H 910NHR 60mA R15Ex 1x2x
RP15-H 910PHR 75mA RP15Ex 1x2x
R30-H 930PHR 65mA
RP30-H 930PHR 85mA RP30Ex 1x2x
R40-H 920NHR 65mA R40Ex 1x2x
RP40-H 920PHR 85mA RP40Ex 1x2x
RK40-H 921NHR 85mA
RPK40-H 921PHR 95mA RPK40Ex 1x2x
RKCL40-P 923NPR
RPKCL40-P 923PPR RPKCL40Ex 1x2x
RKCLB40-P 924NPR
RPKCLB40-P 924PPR RPKCLB40Ex 1x2x
1
StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
2
Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.
12VDC
Standby
Wiegand and OSDP Protocol
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
R10-H 900N
RP10-H 900P 75mA RP10Ex 1x2x
R15-H 910N 60mA R15Ex 1x2x
RP15-H 910P 75mA RP15Ex 1x2x
R30-H 930N 65mA
RP30-H 930P 85mA RP30Ex 1x2x
R40-H 920N 65mA R40Ex 1x2x
RP40-H 920P 85mA RP40Ex 1x2x
RK40-H 921N 85mA
RPK40-H 921P 95mA RPK40Ex 1x2x
RKCL40-P 923N
RPKCL40-P 923P RPKCL40Ex 1x2x
RKCLB40-P 924N
RPKCLB40-P 924P RPKCLB40Ex 1x2x
1
Communication protocols other than Wiegand or Clock
& Data require an additional hardware module which
increases current by 30 mA.
5-16VDC
12VDC for RS-485
12VDC
2
StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
3
Maximum AVG - RMS current draw during continuous PIV card reads. Not
evaluated by UL.
4
Peak - highest instantaneous current draw during RF communication.
5
Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
Standby
CURRENT
Maximum
1
AVG
60mA
150mA 185mA 250mA
165mA 215mA 275mA
AVG
100mA
110mA
125mA 220mA
CURRENT
Maximum
2
AVG
60mA
150mA 185mA 250mA
165mA 215mA 275mA
AVG
100mA
110mA
125mA 220mA
PEAK
2
200mA
1
PEAK
3
200mA
OPERATING TEMPERATURE CABLE LENGTH UL REF NUMBER
3
-30° to 150° F
(-35° to 65° C)
-4° to 149° F
(-20° to 65° C)
RS-485 = 500 ft - 22 AWG
(152 m)
300 ft - 24 AWG
(91 m)
UL Reference Number Deciphering
x1 Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module, R = RS-485
OPERATING TEMPERATURE CABLE LENGTH
4
Communication Lines
Wiegand = 500 ft - 22 AWG
-30° to 150° F
(-35° to 65° C)
-4° to 149° F
(-20° to 65° C)
(152 m)
300 ft - 24 AWG
(91 m)
RS-485 = 4000 ft - 24 AWG
(1,219 m)
Wiegand and RS-485
500 ft - 22 AWG (152 m)
300 ft - 24 AWG (91 m)
5
UL REF NUMBER
UL Reference Number Deciphering
x1 Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module,
R = RS-485 (OSDP)
R10Ex 1x2x
R30Ex 1x2x
RK40Ex 1x2x
RKCL40Ex 1x2x
RKCLB40Ex 1x2x
R10Ex 1x2x
R30Ex 1x2x
RK40Ex 1x2x
RKCL40Ex 1x2x
RKCLB40Ex 1x2x
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
INSTALLATION GUIDE2
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
Mounting
R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
pivCLASS
1
Attach Backplate and Mounting Gasket to Junction Box.
Contactless Models
Mounting holes for US single-gang
electrical boxes.
Install gasket for RK40 and RPK40
models.
Junction box not included.
Contact Models
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
Mounting holes for US double-gang
electrical boxes.
Reverse Conguration Flipping the
backplate allows for placing the Contact
reader on left and the Keypad reader on right.
INSTALLATION GUIDE 3
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Wiring
2
BEEP (YEL)
GRN LED (ORN)
GND (BLK)
+VDC (RED)
DRAIN (BARE)
RED LED (BRN)
HOLD (BLU)
GPIO1(RED/GRN)
GPIO2 (TAN)
OC/TMPR (VIO)
DATA1 (WHT)
DATA2 (GRN)
GPIO3 (PINK)
GPIO4 (GRAY)
18 in
(0.46 m)
Beeper
GRN LED
GND
+VDC
DRAIN
RED
HOLD
GPIO1
GP102
OC/TMPR
DATA1/CLK
DATA2/DATA
GPIO3
GPIO4
DRAIN
HOLD
RED
DATA2/DATA
GPIO3
GPIO4
GRN LED
Beeper
+VDC
GND
P1
GPIO1
GP102
OC/TMPR
DATA1/CLK
ELECTROSTATIC SENSITIVE DEVICES
P2
Note: Previous iCLASS readers had
PLT-01134 A.2
ATTENTION
Observe precautions for handling
reversed RS-485 wiring ( P2-7 &
P2-6 - A & B). When upgrading to
a pivCLASS reader, ensure proper
connectionsasdenedbelow.
Terminal Reader Pigtail Reader
(Module position varies)
(Terminal block and module
position varies)
Pigtail Terminal Description Pigtail Terminal Description
Yellow P1-1 Beeper Input Red / Green P2-7
Orange P1-2 LED Input (GRN) Tan P2-6
Black P1-3 Ground (RTN) Violet P2-5
Red P1-4 +VDC White P2-4
Drain P1-5 Unused Green P2-3
Brown P1-6 LED Input (RED) Pink P2-2
Blue P1-7 Hold Input Gray P2-1
Notes
1
RS-485 applicable for pivCLASS readers.
2
Tamper Output - When activated, output synchronizes to ground (default).
3
Dependentuponreaderconguration.SeetheHTOGforWiegandandClock-in-Datacongurations.
GPIO1 (RS232-T / RS485-FDX/HDX-A) See Note 1
GPIO2 (RS232-R / RS485-FDX/HDX-B) See Note 1
Open Collector Output / Tamper See Note 2
Wiegand Data 1 / Clock See Note 3
Wiegand Data 0 / Data See Note 3
GPIO3 (RS485-FDX-Z) See Note 1
GPIO4 (RS485-FDX-Y) See Note 1
INSTALLATION GUIDE4
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
3
R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Attach to Backplate
Contactless Models
pivCLASS
Attach Reader
a
Contact Models
a
Install Security Screw
b
b
Default: Slide Reader Assembly
towards the right to lock.
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
c
Reversed Conguration: Slide Reader
Assembly to the left to lock.
Contact Technical Support for wiring the
reverseconguration.
INSTALLATION GUIDE 5
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
Power & Testing
4
Contactless Models
Turn on power
Test card
PLT-01134 A.2
Contact Models
Turn on power
Test card
INSTALLATION GUIDE6
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
pivCLASS
Intentionally Blank
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE 7
UL
Connect only to a Listed Access Control / Burglary power-limited power supply. These readers are intended to be used with listed (UL294) control equipment.
RKCLB40-P and RPKCLB40-P readers are suitable for indoor use. R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P and
RPKCL40-P are suitable for outdoor use.
Evaluated for use over Wiegand and RS-485 communications.
Evaluated for use with the M2000 pivCLASS Authentication Module as well as Standard Wiegand and OSDP panels.
FCC Certification
CAUTION: Any changes or modications to this device not explicitly approved by manufacturer could void your authority to operate this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
HID Global
North America: +1 949 732 2000
Toll Free: 1 800 237 7769
Europe, Middle East, Africa: +49 6123 791 0
Asia Pacific: +852 3160 9800
Latin America: +52 477 779 1492
Equipment
8T29
ACC Control READER
General Signaling
Equipment
HID, HID Global and pivCLASS are the trademarks or registered trademarks of HID
Global Corporation, or its licensors, in the U.S. and other countries.
PLT-01334 A.1
Patent Pending
Check reader label for current regulatory approvals.
support.hidglobal.com
hidglobal.com