Install Manual – 6005-910 Rev C
TM
ProxPoint
 Installation Manual 
_____________________________________________________________________________________________________ 
HID Global 15370 Barranca Parkway,  Irvine, CA 92618-1905  USA TEL: 949.732.2000 ● 800.237.7769 FAX: 949.732.2120 
Web page - www.hidglobal.com - ProxPoint Installation Manual 6005-910 Rev C.1                Page 1 of 2            

PARTS LIST (Included)  Quantity
- ProxPoint™ Reader with snap-on 
cover and 18” cable 
1 
- #4-24 x 1” self-tapping flathead screw  2 
- Installation manual  1 
PARTS LIST (Not-Included)  Quantity
- Wire splice  9 
- DC Power supply 5.1 VDC or 12 VDC  1 
Mounting Instructions 
• Determine an appropriate mounting location. The reader 
may be mounted to any surface, including metal. 
• Drill two (2) 5/64-inch (2mm) holes approximately 1 inch 
deep for mounting the reader. 
• Drill a 5/8-inch (16mm) hole for the cable. 
• Remove the snap-on cover from the reader and secure 
the reader to the mounting surface. 
• Route the cable from the reader and/or power supply to 
the host. A linear type power supply is recommended. 
Check all electrical codes for proper cable installation. 
• Test the operation of the reader. After completion of the 
test, replace the snap-on cover. 
• For proper regulatory compliance, the drain wire should 
be disconnected at the power supply end of the cable. 
• Changes or modifications not expressly approved by the 
party responsible for compliance could void the user’s 
authority to operate the equipment. 
• The Reader is intended to be powered from a limited 
power source output of a previously certified power 
supply. 
• In cold climates (-20°F), when operating the Reader from 
a 5V power supply, limit the cable distance to 200ft. For 
longer cable distances, 12V is required.
Connecting the Reader to the Host 
Connect the reader to the host according to the wiring 
table below and the host installation guide. 
Wiegand  Clock & Data  Wire Color 
+DC +DC Red 
Ground Ground Black 
--- Card Present Violet 
Data0 Data Green 
Data1 Clock White 
Shield Ground  Shield Ground  Drain 
Green LED  Green LED  Orange 
Red LED  Red LED  Brown 
Beeper Beeper Yellow 
Hold  Hold  Blue 
Testing and Operation 
• When power is applied to the reader the LED will 
flash green three (3) times while the beeper beeps 
simultaneously. The LED will then turn red. This 
indicates that the microcontroller is operating 
properly. 
• Present an ID card to the reader. The LED will 
momentarily turn green while the beeper beeps 
once, indicating that the card was read 
successfully. 
Important Product Specifications 
Power requirements (linear supply) 
Operating Voltage Range      5.1 – 16.0 VDC 
Peak Current                80 Ma 
Average Current 5V or 12V     20 Ma 
Maximum cable distance       500 ft (153 m) 
To host 
Maximum cable distance       200 ft (61 m) 
To host @5V 
FCC Compliance Statement: This device complies 
with part 15 of the FCC rules. Operation is subject to 
the following two conditions: (1) this device may not 
cause harmful interference, and (2) this device must 
accept any interference received, including 
interference that may cause undesired operation. 