HID pivClass Installation Guide

GOVERNMENT SOLUTIONS for Physical Access
R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H, RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
pivCLASS®
Reader
Installation Guide
PLT-01134 A.2
pivCLASS R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H, RK40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
PLT-01134 A.2
Parts List
1 - Reader and base plate assembly 1 - Installation guide 2 - Terminal connector - terminal readers only
RKCL40, RPKCL40, RKCLB40, and RPKCLB40
4 - M3.5 mm x 12 mm phillips machine screw 4 - #6-32 x .375” phillips self-tapping machine screw 4 - #6 x 1.5” phillips sheet metal screw 3 - #6-32 x .4375” spanner security screw, anti-tamper (Black) 3 - #6-32 x .4375 phillips security screw (Black) 1 - Mounting Gasket
R10, RP10, R15, RP15, R30, RP30, R40, RK40, RP40, and RPK40
2 - M3.5 mm x 12 mm phillips machine screw 3 - #6-32 x .375” phillips self-tapping machine screw 2 - #6 x 1.5” phillips sheet metal screw 1 - #6-32 x .375” spanner security screw, anti-tamper 1 - Mounting gasket - (Optional)
Recommended
• Cable, 6 conductor, 22 or 24 AWG [65 mm or 51 mm] (Belden 3108A or equivalent) - RS-485 + power
• Cable, 6 to 9 conductor, 22 or 24 AWG [65 mm or 51 mm] (Alpha 1296C or equivalent) - Wiegand + power
• DC power supply
• Metal or plastic double-gang junction box - RPKCL40 / RPKCL40 /
RKCLB40 / RPKCLB40
• Metal or plastic single-gang junction box - R10 / RP10 / R15 / RP15 / R30 / RP30 / R40 / RP40 / RK40 / RPK40
• Reader spacer when using metal junction boxes - see HID HTOG.
• Security tool (for spanner security screw, anti-tamper) HID 04-0001-03
Specifications
pivCLASS Protocol
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
R10-H 900NHR
RP10-H 900PHR 75mA RP10Ex1x2x
R15-H 910NHR 60mA R15Ex1x2x
RP15-H 910PHR 75mA RP15Ex1x2x
R30-H 930PHR 65mA
RP30-H 930PHR 85mA RP30Ex1x2x
R40-H 920NHR 65mA R40Ex1x2x
RP40-H 920PHR 85mA RP40Ex1x2x
RK40-H 921NHR 85mA
RPK40-H 921PHR 95mA RPK40Ex1x2x
RKCL40-P 923NPR
RPKCL40-P 923PPR RPKCL40Ex1x2x
RKCLB40-P 924NPR
RPKCLB40-P 924PPR RPKCLB40Ex1x2x
1
 StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
2
Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
3
Peak - highest instantaneous current draw during RF communication.
12VDC
Standby
Wiegand and OSDP Protocol
PRODUCT BASE PART NUMBER INPUT VOLTAGE (VDC)
R10-H 900N
RP10-H 900P 75mA RP10Ex1x2x
R15-H 910N 60mA R15Ex1x2x
RP15-H 910P 75mA RP15Ex1x2x
R30-H 930N 65mA
RP30-H 930P 85mA RP30Ex1x2x
R40-H 920N 65mA R40Ex1x2x
RP40-H 920P 85mA RP40Ex1x2x
RK40-H 921N 85mA
RPK40-H 921P 95mA RPK40Ex1x2x
RKCL40-P 923N
RPKCL40-P 923P RPKCL40Ex1x2x
RKCLB40-P 924N
RPKCLB40-P 924P RPKCLB40Ex1x2x
1
Communication protocols other than Wiegand or Clock & Data require an additional hardware module which increases current by 30 mA.
5-16VDC
12VDC for RS-485
12VDC
2
StandbyAVG-RMScurrentdrawwithoutacardintheRFeld.
3
Maximum AVG - RMS current draw during continuous PIV card reads. Not evaluated by UL.
4
Peak - highest instantaneous current draw during RF communication.
5
Wiegand Cable Lengths:
100 ft (30.5 m) 22 AWG @ 5 - 6.4VDC
500 ft (152 m) 22 AWG @ 6.5 - 16VDC
Standby
CURRENT
Maximum
1
AVG
60mA
150mA 185mA 250mA
165mA 215mA 275mA
AVG
100mA
110mA
125mA 220mA
CURRENT
Maximum
2
AVG
60mA
150mA 185mA 250mA
165mA 215mA 275mA
AVG
100mA
110mA
125mA 220mA
PEAK
2
200mA
1
PEAK
3
200mA
OPERATING TEMPERATURE CABLE LENGTH UL REF NUMBER
3
-30° to 150° F (-35° to 65° C)
-4° to 149° F
(-20° to 65° C)
RS-485 = 500 ft - 22 AWG (152 m) 300 ft - 24 AWG (91 m)
UL Reference Number Deciphering
x1 Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module, R = RS-485
OPERATING TEMPERATURE CABLE LENGTH
4
Communication Lines
Wiegand = 500 ft - 22 AWG
-30° to 150° F (-35° to 65° C)
-4° to 149° F
(-20° to 65° C)
(152 m) 300 ft - 24 AWG (91 m) RS-485 = 4000 ft - 24 AWG (1,219 m)
Wiegand and RS-485
500 ft - 22 AWG (152 m) 300 ft - 24 AWG (91 m)
5
UL REF NUMBER
UL Reference Number Deciphering
x1 Reader Colors: K = Black, G = Gray
x2 Wiring: N = Pigtail, T = Terminal
x3 Communications: N = No Module,
R = RS-485 (OSDP)
R10Ex1x2x
R30Ex1x2x
RK40Ex1x2x
RKCL40Ex1x2x
RKCLB40Ex1x2x
R10Ex1x2x
R30Ex1x2x
RK40Ex1x2x
RKCL40Ex1x2x
RKCLB40Ex1x2x
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
INSTALLATION GUIDE2
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
PLT-01134 A.2
Mounting
R10-H, RP10-H, R15-H, RP15-H, R30-H, RP30-H, R40-H, RP40-H,
RPK40-H, RKCL40-P, RPKCL40-P, RKCLB40-P, RPKCLB40-P
pivCLASS
1
Attach Backplate and Mounting Gasket to Junction Box.
Contactless Models
Mounting holes for US single-gang electrical boxes.
Install gasket for RK40 and RPK40 models.
Junction box not included.
Contact Models
Mounting holes for US double-gang electrical boxes.
Reverse Conguration Flipping the backplate allows for placing the Contact reader on left and the Keypad reader on right.
© 2012 - 2014 HID Global Corporation/ASSA ABLOY AB. All rights reserved.
INSTALLATION GUIDE 3
Loading...
+ 5 hidden pages