HID FlexSmart 6092, FlexSmart 6091, FlexSmart 6090, FlexSmart 609 Installation Manual

Page 1
9292 Jeronimo Road Irvine, CA 92618-1905
HID® FlexSmart™
609X Series Euro Readers
INSTALLATION GUIDE
© 2007 HID Global Corporation. All rights reserved.
Document Number 6090A-901
Document Version A.1
Page 2
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, A.1
Contents
1 Overview .......................................................................................................................... 3
2 Mounting.......................................................................................................................... 4
3 Wiring............................................................................................................................... 6
Wiegand Output Timing ............................................................................................................. 8
ABA Track 2 Magnetic Stripe Output Timing ........................................................................... 8
Regulatory................................................................................................................................... 8
Models ......................................................................................................................................... 9
Contact ........................................................................................................................................ 9
Page 2 of 9 March 12, 2007
© 2007 HID Global Corporation. All rights reserved.
Page 3
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, Rev A.1
1 Overview
1.1 Introduction
The HID® FlexSmart™ 609X series are RFID card readers based on MIFARE® smartcard technology. They are encapsulated units designed to attach to a single-gang electrical box, suitable for both indoor and outdoor use. Data is output in either Wiegand or ABA track 2 (magstripe) formats, and is application dependent. Electrical connection is made via a 6-way detachable screw terminal block.
Note: The format and function of the reader depends on the configuration loaded from a configuration card.
1.2 Parts Included
First, unpack the contents and become familiar with the components.
The following items will be included with FlexSmart readers:
1. Installation Guide
2. MIFARE reader module
3. Fixing accessories
1.3 Specifications
Supply Voltage
Supply Current
Input
Output formats
Operating Frequency
Data Transmission
Authentication
Operating Temperature
Non-Operating Temperature
Operating Humidity
Finish
Dimensions
Weight
9VDC to 16VDC (12VDC typical)
20 mA typical, 75mA peak
2 lines available
Typical use: 1 line LED control, and 1 line buzzer control
Application dependent
Wiegand/ABA track 2
Application dependent
13.56MHz, 106k Baud
Contactless
ISO/IEC DIS 9792-2
-4°F (-20°C) to 131°F (55°C)
-40°F (-40°C) to 158°F (70°C)
5% to 95% condensing
Black
3.39” x 3.39” x 1.18” (86 x 86 x 30 mm)
9 oz (250g)
March 12, 2007 Page 3 of 9
© 2007 HID Global Corporation. All rights reserved.
Page 4
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, A.1
2 Mounting
Figure 2-1 – Overall Dimensions
Page 4 of 9 March 12, 2007
© 2007 HID Global Corporation. All rights reserved.
Figure 2-2 – Back Plate Dimensions
Page 5
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, Rev A.1
Figure 2-3 – Attaching Backplate
March 12, 2007 Page 5 of 9
© 2007 HID Global Corporation. All rights reserved.
Figure 2-4 Install Reader
Page 6
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, A.1
Figure 2-5 – Fascia Label
3 Wiring
3.1 Cable Types and Maximum Lengths
The 609x series readers require a minimum supply voltage of 9.0 VDC at the reader. Voltage drops, caused by the cable resistance, can be compensated by increasing the power supply voltage, provided the maximum supply voltage (16.0 VDC) is not exceeded at the reader.
CAUTION: THE READER SUPPLY VOLTAGE MUST NOT EXCEED 16.0 VDC.
CAUTION: DO NOT USE CABLES WITH GAUGES SMALLER THAN 24 AWG:
The following are recommended cable types and maximum cable lengths for a cable connecting the power supply to the reader.
Maximum Cable Length Cable Type
200’ (61 m) 24 AWG (0.51mm), overall foil shield, Belden 9533 series or equivalent.
300’ (91 m) 22 AWG (0.64mm), overall foil shield, Alpha Wire 5192C series or equivalent.
500’ (152 m) 18 AWG (1.02mm), overall foil shield, Alpha Wire 5382C series or equivalent.
Page 6 of 9 March 12, 2007
© 2007 HID Global Corporation. All rights reserved.
Page 7
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, Rev A.1
System data line terminations may affect the cable required. Contact your system manufacturer for exact requirements. Installation should be in accordance with National Electric Code ANSI/NFPA 70.
Note: The cable should have a minimum of four conductors (two for power and two for output data). If the reader’s input control lines are required, then the cable will need to have extra one or two conductors depending on the inputs required.
3.2 Connections
There is a 6-way connector with detachable terminal block at the rear of the unit. Wire this connector according
Pins 5 and 6, (LED and buzzer control inputs) may be left unconnected if they will not be used.
The cable shield/drain should not be connected to anything at the reader end.
3.3 Grounding
At the controller end of the cable the shield/drain should be connected directly to an earth ground. An earth ground can be established by driving a copper clad ground rod into the earth. If a direct connection to a ground rod is not possible, connect the shield/drain to an earth grounded cold water metal pipe or steel frame (building beam) that connects to earth. Make certain that the DC resistance between your established earth ground and the system ground is 50 ohms or less. Do not connect to a copper fire sprinkler system because this may have non-conductive couplings.
Pin Reader Wiring
Pin 6 Beeper control input
Pin 5 LED control input
Pin 4 Wiegand data ‘1’/Data
Pin 3 Wiegand data ‘0’/Strobe
Pin 2 Power supply 0V (ground)
Pin 1 Power supply +VE
Figure 3-1 Wiring Connections
Note: The shield/drain should be connected at the power supply.
Connection of the shield/drain to an earth ground will provide greater ESD protection of the reader.
March 12, 2007 Page 7 of 9
© 2007 HID Global Corporation. All rights reserved.
Page 8
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, A.1
Wiegand Output Timing
ABA Track 2 Magnetic Stripe Output Timing
Regulatory
FCC
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
UL
This Proximity Reader is intended to be powered from a limited power source output of a previously certified power supply. This Reader is intended to be used with UL 294 Listed Control Equipment.
Page 8 of 9 March 12, 2007
© 2007 HID Global Corporation. All rights reserved.
Page 9
FlexSmart™ 609X Series Euro Readers Installation Guide – 6090A-901, Rev A.1
Models
6090 HID Format MIFARE Euro Reader
6091 Custom MIFARE Euro Reader
6092 Custom DESFire Euro Reader
Contact
Americas
HID Corporation (California, USA)
support: tech@hidcorp.com main: (949) 598-1600 support: 1-800-237-7769 fax number: (949) 598-1690
Europe, Middle East and Africa
HID Corporation, Ltd. (Haverhill, UK)
support: eusupport@hidcorp.com main: +44 (0) 1440 714 850 support: +44 (0) 1440 711 822 fax number: +44 (0) 1440 714 840
Asia-Pacific
HID Asia Pacific Ltd. (Hong Kong)
support: asiasupport@hidcorp.com main: (852) 3160 9800 support: (852) 3160 9802 fax number: (852) 3160 4809
March 12, 2007 Page 9 of 9
© 2007 HID Global Corporation. All rights reserved.